• 제목/요약/키워드: vertical cracks

검색결과 155건 처리시간 0.022초

5층열장벽 피막의 고온 물성에 관한연구 (A Syudy on the High Temprerties of the 5Layer Functionally Gradient Thermal Barrier Coating)

  • 한주철;정철;송요승;윤종구;노병호;이구현
    • 한국표면공학회지
    • /
    • 제31권1호
    • /
    • pp.12-23
    • /
    • 1998
  • The Thermal Barrier Coating(TBC) has been used to improve the heat barrier and tribological properties of the aircraft engine and the automobile engine in high temperature. Especially, the high temperature tribological propertied of the cylinder haed and the piston crown of diesel engine was emphasized. Therefore, the purpose of this work was to evaluate the microstructure, tribological propeer in high tempearmal shock resistance and bonding strength of five layer functionally gradient TBC for the applications. The five layerwere composed with 100% ceramic insulating later, 75(ceramic):25 (metal) layer, 50:50 layer, 25:75 layer and 100% metal bonding layer to redude the thermal stress. the YSL and MSL poweders were the insulation ceramics powers. The NiCrAly, Inconel625 and SUS powders were the bonding and mixingg powders for plasma spray process. According to the result of high temperature wear test, the wera resistance of YSZ/NiCrAlY siytem was most out standing at 600 and $800^{\circ}C$. At $400^{\circ}C$, the wear resistance of YSZ/Inconel system was better than others. Wear volume at other temperature because of the low temperature degration of zirconia. The thermal shock mechanism of 5 later is the vertical crack gegration in insulating layer. this means that the initial cracks were generated in the top layer, and then developed into the composite layers during thermal shock test. Finally, these cracks werereached to the interface of coating and substrate and also, these vertioal cracks join with the horizontal cracks of the each layers. The bonding strength of YSZ/NiCrAlY and YSZ/Inconel 5 layer system is better than other 5layer systems. The theramal shock resistance of thermal barrier coating s with 5 layer system is better than that of 3 layers and 2 layers.

  • PDF

보신각종(普信閣鐘)의 비파괴조사(非破壞調査) (Nondestructive Analysis on the bell of Boshin-gak)

  • 권혁남;유혜선
    • 박물관보존과학
    • /
    • 제6권
    • /
    • pp.3-10
    • /
    • 2005
  • 국립중앙박물관의 이전에 따른 보물 제2호 보신각종 이전을 준비하는 과정에서 사전조사를 통해 종의 안전성을 점검하기 위해 60Co에 의한 γ-선 투과조사를 실시하여 현재 존재하고 있는 내부균열 및 주조결함 등을 조사하였다. 또한 엑스선형광분석법을 이용하여 종의 재질조사를 실시하였다. 그 결과 가로방향으로 65.2%, 세로방향으로 62.5%에 해당하는 균열이 존재하고 있는 것을 확인하였으며 그 깊이는 5cm 내외인 것으로 조사되었다. 또한 성분분석 결과 구리가 89~92%, 주석이 7.5~10.5%이고 불순물로 보이는 납은 0.1~0.3%이며 철, 망간 등은 0.1% 미만으로 매우 적은 양이 함유되어 있다.

3층 Cu/Al/Cu 클래드재의 열처리온도에 따른 변형 및 파단거동 (Effect of Heat Treatment on the Deformation and Fracture Behaviors of 3-ply Cu/Al/Cu Clad Metal)

  • 김인규;하종수;홍순익
    • 대한금속재료학회지
    • /
    • 제50권12호
    • /
    • pp.939-948
    • /
    • 2012
  • A 3-ply clad metal consisting of aluminum and copper was fabricated by roll bonding process and the microstructures and mechanical properties of the roll-bonded and post-roll-bonding heat treated Cu/Al/Cu clad metal were investigated. A brittle interfacial reaction layer formed at the Cu/Al interfaces at and above $400^{\circ}C$. The thickness of the reaction layer increased from $12{\mu}m$ at $400^{\circ}C$ to $28{\mu}m$ at $500^{\circ}C$. The stress-strain curves demonstrated that the strength decreased and the ductility increased with heat treatment up to $400^{\circ}C$. The clad metal heat treated at $300^{\circ}C$ with no indication of a reaction layer exhibited an excellent combination of the strength and ductility and no delamination of layers up to final fracture in the tensile testing. Above $400^{\circ}C$, the ductility decreased rasxpidly with little change of strength, reflecting the brittle nature of the intermetallic interlayers. In Cu/Al/Cu clad heat treated above $400^{\circ}C$, periodic parallel cracks perpendicular to the stress axis were observed at the interfacial reaction layer. In-situ optical microscopic observation revealed that cracks were formed in the Cu layer due to the strain concentration in the vicinity of horizontal cracks in the intermetallic layer, promoting the premature fracture of Cu layer. Vertical cracks parallel to the stress axis were also formed at 15% strain at $500^{\circ}C$, leading to the delamination of the Cu and Al layers.

Experimental investigation into brick masonry arches' (vault and rib cover) behavior reinforced by FRP strips under vertical load

  • Takbash, Majid Reza;Morshedi, Abbas Ali Akbarzadeh;Sabet, Seyyed Ali
    • Structural Engineering and Mechanics
    • /
    • 제67권5호
    • /
    • pp.481-492
    • /
    • 2018
  • The current experimental study is the reinforcement of the simple curvature vault masonry structures. In this study, we discuss complex structure include vault and rib cover with two radii and actual dimensions under a vertical load. The unreinforced structure data were compared with analysis data. The analysis data are in good agreement with experimental data. In the first experiment, a structure without reinforcement is tested and according to the test results, the second structure was reinforced using the carbon polymer fibers and the same test is done to see the effects of reinforcement. Based on the test results of the first structure, the first cracks are created in the vault. Moreover, the reinforcement with carbon fibers will increase the loading capacity of the structure around 35%.

37층 초고층주상복합건물 SRC기둥의 기둥축소량 현장계측 및 보정법 (Field Measurement and Compensation Method of Column Shortening for SRC Columns in 37-story Residential Building)

  • 송화철;도근영;조훈희
    • 한국건축시공학회지
    • /
    • 제5권4호
    • /
    • pp.145-152
    • /
    • 2005
  • Long-term axial shortening of the vertical elements of tail buildings results in differential movements between two elements and may lead to the additional moments of connection beam and slab elements, and other secondary effects, such as cracks of partitions or curtain walls. Accurate prediction of time-dependent column shortening is essential for tall buildings from both strength and serviceability aspects. The compensation method is different from reinforced concrete and SRC(Steel Reinforced Concrete) members. The SRC columns are usually compensated according to total differential shortening between two vertical elements. In this study, column shortenings of 37-story W building under construction are predicted and compensated. The SRC column shortenings are compared with the actual column shortening by field measurement and the column shortenings are reanalysed and recompensated.

집중하중을 받는 철근콘크리트 깊은 보의 전단거동에 대한 실험적 연구 (An Experimental Study on the Shear Behavior of Reinforced Concrete Deep Beams Subject to Concentrated Loads)

  • 송우석;이진섭;양창현;김상식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.273-278
    • /
    • 1994
  • The shear behavior of simply supported reinforced concrete deep beams subject to concentrated loads has been scrutinized experimentally to verify the influence of the structural parameters such as shear span ratio, and the horizontal and vertical web reinforcements. A total of 27 specimens has been tested at the laboratory. In the tests all specimens have failed in shear causing inclined cracks from the load application points to the supports. The load bearing capacities have changed significantly depending on the shear span ratio. The effects of the vertical and horizontal reinforcements on the shear strength and crack initiation and propagation have been carefully checked and analyzed.

  • PDF

지중 RC 도시지하철고 구조물의 내진설계 (A Seismic Design of RC Underground Subway Structure)

  • 정제평;임동원;이성로;김우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.357-362
    • /
    • 2000
  • This Paper presents dynamic analysis of underground R/C Subway Structure, subjected to seismic actions. Earthquakes brought serious damage to RC subway Structure. Foe studying the collapse mechanism of underground RC Subway, seismic of a subway station is simulated in using FEM program ASP2000 of two-dimension based on the path dependent RC elastic model, soil foundation and interfacial models. The shear failure of intermediate vertical columns is founds to be the major cause of the structural collapse. According to FEM simulation of the failure mechanism, it is considered that the RC column would lose axial load carrying capacity after the occurrence of the localized diagonal shear cracks , and sudden failure of the outer frame would be followed. Specially, the shear stress in the middle slab reaches maximum shear capacity. So, the Structure would fail in the middle slab as a result of erasing the vertical ground motion computation.

  • PDF

철근콘크리트와 강을 합성한 복합 단면보의 구조거동평가 (Structure Behavior Evaluation of Beams composited with Steel and Reinforced Concrete)

  • 김인석;김학수
    • 한국강구조학회 논문집
    • /
    • 제20권5호
    • /
    • pp.665-673
    • /
    • 2008
  • 최근 장대 건설 구조물에 사용이 증가되고 있는 합성형 구조물에서 나타나고 있는 예기치 못한 일부 균열 현상의 구조적 원인을 분석하기 위하여, 강재복부의 수직보강재, stud 및 dowel bar의 유무, 전단철근의 간격과 콘크리트 강도 등을 실험변수로 하여 4점 재하 휨시험을 통해 강재와 철근콘크리트간의 구조적 합성거동 효과를 분석 하였다. 실험결과, 수직보강재는 강재의 국부좌굴 방지와 파괴시 강재와 콘크리트의 부착파괴를 방지하여 구조적 합성거동에 따른 단면내력(파괴하중)의 증진에 효과적인 것으로 나타났으나, 추가적으로 설치한 stud 및 dowel bar, 콘크리트의 강도와 전단철근량 등은 합성보의 휨거동에 큰 영향을 주지 않는 것으로 나타났다.

Theoretical Consideration of Nondestructive Testing by use of Vertical Magnetization and Magneto-Optical Sensor

  • Lee, Jinyi;Tetsuo Shoji;Dowon Seo
    • Journal of Mechanical Science and Technology
    • /
    • 제18권4호
    • /
    • pp.640-648
    • /
    • 2004
  • This paper describes a new magnetization method for non-destructive testing with magneto-optical sensor (denoted as MO sensor) which have the following characteristic : high observation sensitivity, independence of the crack orientation, and precise imaging of a complex crack geometry such as multiple cracks. When a magnetic field is applied normally to the surface of a specimen which is significantly larger than its defects, approximately the same magnetic charge per unit area occurs on the surface of the specimen. If there is a crack in the specimen, magnetic charge per unit area has the same value at the bottom of the crack. The distribution of the vertical component of the magnetic flux density, B$\_$Z/, is almost uniform over the no-crack area (denoted as B$\_$Z,BASE/), while the magnetic flux density is smaller in the surroundings of the crack(denoted as B$\_$Z,CRACK/) If B$\_$Z, BASE/ is a bit larger than the saturated magnetic flux density of the MO sensor (B$\_$s/) , then small magnetic domains occur over the crack area and a large domain over the non-crack area because B$\_$Z,CRACK/ is smaller than B$\_$s/.

자전거 프레임의 소재 및 종류에 따른 피로특성 (Fatigue Characteristics of Bicycle Frames Depending on Types and Materials)

  • 권경배;정성균
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.8-12
    • /
    • 2017
  • Bicycles are very popular sporting goods in these days. Thus, the durability of bicycles is very important for the safety of bicyclists. It is well known that a bicycle frame is a major component which is essential to the safety and performance of a complete bicycle. In this study, the durability of bicycle frames were experimentally investigated under the fatigue load. Eighty bicycle frames with different types and materials were prepared and tested according to EN standards. Three kinds of fatigue loads, that is, pedalling, vertical and horizontal fatigue load, which occur constantly during riding a bicycle, were applied to the bicycle frames. The experimental results show that the horizontal fatigue load was the severest mode to pass EN standard. The pass ratio of horizontal fatigue load test was 45.2%, while the pass ratio of vertical fatigue load test was 100%. Most of cracks were found at the right side of bottom bracket shell and at the intersection area between head tube and down tube. It seems that the experimental results can be applied to improve the safety and performance of a bicycle frame.