• Title/Summary/Keyword: ventilation house

Search Result 302, Processing Time 0.025 seconds

Development of roll - up ventilation system for pipe- constructed plastic film greenhouse (파이프 비닐온실용 권취식 창개폐기의 개발)

  • 이기명;박규식;김유일;김태홍
    • Journal of Bio-Environment Control
    • /
    • v.4 no.2
    • /
    • pp.232-239
    • /
    • 1995
  • This study was carried out to get required torque data needed to design and develop a roll-up ventilation system in a pipe-constructed plastic film green-house. The results obtained from this study are as follows : 1. The required torques of a roll-up ventilation system in greenhouse are the functions of its length. The torques should multiplied by the conversion coefficients (2.0 in ceiling vent, 1.8 in side vent) in case of application. 2. In constructing pipe-constructed plastic film greenhouse, a shaft pipe is the largest essential element in roll - up shaft weight constitution which have an effect on the required torques. Therefore, the pipe should be light using nonferrous materials like aluminum alloy. 3. A planetary reduction ventilator of differential ring gear type is suitable for a roll-up ventilation system, because it can make high efficient reduction just using the first step shift.

  • PDF

Optimal Design for Airflow Distribution of Total Heat Exchanger in House Using CFD (전열교환기의 세대내 풍량 분배를 위한 CFD를 이용한 최적설계방안)

  • Kim, Jin-Ho S.;Song, Nan-Jung;Lee, Geon-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.701-705
    • /
    • 2009
  • After revision of law of architecture in 2006, all houses which have more 100 households must has ventilation unit for the indoor air quality. Optimal design of the natural and the mechanical ventilation has being considered. In this paper, it is carried out about optimal design for airflow distribution of total heat exchanger in houses using CFD. As the result, first design of ventilation has some problem in porch area. Adding diffusers in porch area and changing diffuser schedule make more efficient ventilation than original design.

  • PDF

The Technology Applied 3 Liter House, Super Energy Saving Building (3L House의 설계, 시공 및 평가)

  • Park, Sun-Hyo;Park, Yong-Seung;Won, Jong-Seo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.814-819
    • /
    • 2006
  • This research is on the design and introducing of integrated thermal performance of super energy saying building, called 3 Liter house which can be sustained with 3 liter oil(kerosene) per $yr.m^2$. 3 liter houses(Passive houses) offer extended living comfort with only 15 to 20% of the space heating demand of conventional new building. To achieve this purpose, the efficiency of building components is improved, such as walls, windows or ventilation system and the construction technology is improved, such as the prevention of thermal bridge and the air tightness. The fuel cell is used as alternative energy. Energy consumption of 3L house is 2.08 [liter/$yr.m^2$] in monitoring result of $2006/2/1{\sim}2/7$ and ACH50 is 0.67 in result of Blow Door Test, therefore 3L House is well- insulated and well- airtighted house.

  • PDF

Effect of the Ventilation Method on the Growth and Quality of Melon (Cucumis melo L.) in Greenhouse of Tunnel Type (터널형 하우스에서 환기방법이 참외의 생육 및 품질에 미치는 영향)

  • 신용습;연일권;도한우;서동환;배수곤;최성국;최부술
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.187-193
    • /
    • 1996
  • This experiment was conducted to investigate the influence of temperature variation by the different ventilation methods on the growth and quality of oriental melon in greenhouse of tunnel type 1. The dropping effect in temperature by ventilation types was best at type 3 and those of type 2, type 1 were in order. 2. The temperature distribution in type 3 was uniformed as air- inflow and air- outflow by wind ventilation were easier than others. Whereas the temperature of type 1 having lateral ventilation hole and type 2 having the zenith ventilation tube and lateral ventilation hole was ascended, because small ventilation area of ventilation tube and hole could not make the gravity and wind ventilation successfully. 3. When compared with air amount of three types ventilated by the temperature difference of outside and inside of tunnel type house, that of type 3 was more than those of type 1 and type 2. 4. Type 3 was better than type 2 and type 1 in lear numbers, leaf area, fruit weight, flesh thickness, malformed fruit rate, and marketable fruit rate. 5. Marketable fruit rate of all treatment at each harvesting stages was rised, as goes to the latter periods.

  • PDF

Analysis of Field Measured Odor Emission Rate in Pig Houses (국내 돈사 악취 방출량 측정 결과 분석)

  • Decano-Valentin, Cristina;Lee, In-bok;Yeo, Uk-hyeon;Jeong, Duek-young;Lee, Sang-yeon;Park, Se-jun;Cho, Jeong-hwa;Lee, Min-hyeong;Jeong, Hyohyeog;Kim, Da-in;Kang, Sol-moe
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.6
    • /
    • pp.55-63
    • /
    • 2022
  • Odors emitted from pig houses have been a constant root of legal issues in pig farming. These gases are among the main causes of health and mental stresses to nearby communities, so policymakers and researchers continuously study to reduce the concentration of odorous gases from pig facilities. A continuous field experiment proved that the concentration of odor emissions inside the pig houses is highly dependent on ventilation rate, breeding details, and animal activities. However, the standard odor emission rate worldwide widely varies due to differences in pig house designs and ventilation requirements. Thus, this study aimed to measure the odor emission rates, considering the actual condition of selected Korean pig houses, through field measurement. The odor measurements were performed at three different pig production facilities without odor abatement technologies. The target experimental pig houses were buildings for weaning, growing, and fattening pigs. Results showed that the actual ventilation rate in target pig houses falls below the standard ventilation requirement of pigs, resulting in high odor concentrations inside the pig houses.

A Study of Measurement on Airtightness and Air-Flow Performance of Apartment Housing Adopting Window Frame-Type Natural Ventilation (자연환기장치가 적용된 공동주택의 기밀 및 공기유동 성능 실측 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Kim, Sun-Dong
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.325-332
    • /
    • 2014
  • The purpose of this study was to measure the airtightness and Air-Flow Performance for 7th house of small apartment houses adopted window frame-type natural ventilation. All window and living room door is provide with window frame-type natural ventilation, and there is provide with manual controller. As the object of measurement, the 6th type small apartment houses with area of $33m^2$ to $51m^2$ was selected. airtightness performance was measured at the front door using Blower door system. We measured ventilation rate per hour on 50Pa pressure different between inside and outside by the 1st to 6th cases. As a result, when the natural ventilation frame was closed, average amounts are shown as the ventilation rate per hour were 2.27ACH (CASE1). and the result is similar to general apartment house (1.65~4.28ACH). When the natural ventilation frame was open, average amounts are shown as the ventilation rate per hour were 5.87ACH (CASE6). In addition, that's a 3.6ACH increased more than CASE1.

Experimental Study on the Combined Effect of Power and Heat according to the Ventilation of Back Side in Roof Integrated PV System (주택 지붕일체형 PV시스템 후면환기에 따른 발전성능 변화 실험연구)

  • Yoon, Jong-Ho;Han, Kyu-Bok;An, Young-Sub
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.169-174
    • /
    • 2007
  • Building integrated photovoltaic(BIPV) system operates as a multi-functional building construction material. They not only produce electricity, but also are building integral components such as facade, roof, window and shading device. As PV modules function like building envelope in BIPV, combined thermal and PV performance should be simultaneously evaluated. This study is to establish basic Information for designing effective BIPV by discovering relations between temperature and generation capability through experiment when the PV module is used as roof material for houses. To do so, we established 3kW full scale mock-up model with real size house and attached an PV array by cutting in half. This is to assess temperature influence depending on whether there is a ventilation on the rear side of PV module or not.

A Study on a Proper Reduction Process of Indoor Air Pollutants In Newly-Constructed Multi-Family Houses (신축공동주택에서의 실내공기 오염물질 방출 저감 프로세스에 관한 연구)

  • Yu Hyung-Ku;Park Jin-Chul;Rhee Eon-Ku
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.468-476
    • /
    • 2005
  • The purpose of this study is to investigate actual air quality in newly-constructed multi-family houses and to improve Indoor Air Quality (IAQ). The field measurement was conducted in four different newly-constructed multi-family house complexes in Seoul and one existing multi-family house complex in Kyong-gi province. The result of the measurement shows that indoor concentrations of Formaldehyde and TVOC in newly-constructed multi-family houses are much higher than the foreign standards. To establish a proper process for reducing indoor air pollutants, various experiments have been conducted; application of natural materials, bake-out practice, closure of all openings without ventilation, and use of mechanical ventilation system. The result indicates that three practices (natural materials, bakeout, mechanical ventilation) can reduce the level of indoor air pollutants almost in half during the experiments. However, each practice has its limitation and is insufficient to satisfy IAQ standards. Therefore, the study proposes a proper reduction process of indoor air pollutants which combines four different practices in time sequence.

Hygrothermal Performance Improvement Plan of Standard Model for Rural Housing and Wooden Housing (농촌주택 및 목조주택 표준모델 구조체의 습·열 환경 성능 개선 방안)

  • Yoo, Dong-Wan;Lee, Tae-Goo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.23 no.4
    • /
    • pp.63-71
    • /
    • 2021
  • The purpose of this study was to investigate whether the standard models for rural housing and wooden housing model have performance for hygrothermal and to propose a way of improvement relevant to hygrothermal performance for those models. All of the models to be analyzed were found to have some parts that were absent of stability in terms of performance for hygrothermal. In the process of analyzing the causes and proposing improvement measures, the following conclusions were derived. Fist, The exterior surface of the structure should be composed of a structure with good moisture permeability, and for the interior surface, a variable vapor retarder paper should be applied in consideration of the reverse condensation phenomenon in summer. Second, in terms of performance for hygrothermal, applications of external insulation plaster finish to the exterior wall or of ventilation method using a rafter vent on the roof should be avoided. Third, a rain screen method with a ventilation layer should be applied to the exterior wall, and a method of constructing ventilation layer separated from the insulation layer with a vapor retarder paper should be applied to the roof. Fourth, the application of insulation materials having capillary action, such as wood fiber insulation board or cellulose insulation board, contributes to more stable performance for hygrothermal.

A Study on the Mechanical Ventilation System of Bathroom in Apartment House (공동주택 화장실의 기계 환기시스템에 관한 연구)

  • 함진식
    • Journal of the Korean housing association
    • /
    • v.12 no.3
    • /
    • pp.141-148
    • /
    • 2001
  • To design mechanical ventilation for bathroom of apartment houses where air supply and exhaust are taken into consideration, mock-ups of ventilation systems, widely used in bathroom of apartment houses with an area of 100$\textrm{m}^2$, were made and installed in a laboratory. These ventilation mock-ups were available for control of air supply and exhaust, and the sizes of supply openings were 40cm${\times}$1cm, 40cm${\times}$3cm, and 40cm${\times}$5cm. They were installed at five positions, spaced 45cm at a height of 5cm from the floor. The exhaust fan was designed for its operating voltage to be set to five steps(100V, 130V, 150V, 180V and 220V) in order to control its air flow rates. When the size and position of each supply opening were changed with the wind velocity of the exhaust fan set to the step 5, the ventilation rates were measured and analyzed by the concentration decay method of tracer gas method, in order to present an efficient mechanical ventilation system. The results of the study revealed that the ventilations rates would increase in the presence of supply openings, compared to the absence of supply openings, and that the larger the size of the supply opening, the more the ventilation rates. Therefore, it was found necessary to take air supply into consideration.

  • PDF