The Technology Applied 3 Liter House, Super Energy Saving Building

3L House의 설계, 시공 및 평가

  • 박선효 (대림산업(주) 기술연구소) ;
  • 박용승 (대림산업(주) 기술연구소) ;
  • 원종서 (대림산업(주) 기술연구소)
  • Published : 2006.06.21

Abstract

This research is on the design and introducing of integrated thermal performance of super energy saying building, called 3 Liter house which can be sustained with 3 liter oil(kerosene) per $yr.m^2$. 3 liter houses(Passive houses) offer extended living comfort with only 15 to 20% of the space heating demand of conventional new building. To achieve this purpose, the efficiency of building components is improved, such as walls, windows or ventilation system and the construction technology is improved, such as the prevention of thermal bridge and the air tightness. The fuel cell is used as alternative energy. Energy consumption of 3L house is 2.08 [liter/$yr.m^2$] in monitoring result of $2006/2/1{\sim}2/7$ and ACH50 is 0.67 in result of Blow Door Test, therefore 3L House is well- insulated and well- airtighted house.

Keywords