• Title/Summary/Keyword: ventilating

Search Result 226, Processing Time 0.033 seconds

The Effects of the Curing Methods on the Stalk Curing Period in Burley Tobacco (버어리종 건조방법이 대말림기간에 미치는 영향)

  • 배성국;한철수
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.16 no.2
    • /
    • pp.139-143
    • /
    • 1994
  • This study was carried out to control the stalk curing period in Burley Tobacco, for its period was longer than 40 days. The 5 methods were treated to shorten the stalk curing period. The curing period was shortened for 1~3 days by the harvesting methods and the amount of predehydration, but it was shortened for 8 days by the hanging methods(sloping and horizontal curing)and the hanging density(90 plants/3.3m2) without the decrease of quality. In the ventilating condition of the curing house, the curing period could be controlled for 5 dyes with the quality like the conventional cured leaves by closing the curing house from the late curing stage. But when the curing house was not ventilated earlier, however the curing period was shortened but its quality was decreased.

  • PDF

Linear Digital Decentralized Control System for Smart Space (스마트 스페이스 구축을 위한 선형 디지털 분산 제어 시스템 개발)

  • Kim Do Wan;Joo Young Hoon;Park Jin Bae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.1
    • /
    • pp.36-41
    • /
    • 2005
  • The smart space is composed of the wire and/or wireless network, multi-sensor-based environment, and many various controllers. For the smart space, this paper presents a new design method of multirate digital decentralized controller using the digital redesign technique. In specific, the proposed method is based on the delta-operator and the multirate sampling and takes the form of the LMIs. To shows the feasibility of the suggested method, the computer simulations for HVAC system are provided.

A NUMERICAL STUDY OF THE VENTILATION AND FIRE SIMULATION IN A ROAD TUNNEL (도로터널 환기/제연 시스템 시뮬레이션)

  • Park, Jong-Tack;Won, Chan-Shik;Hur, Nahm-Keon;Cha, Cheol-Hyun
    • Journal of computational fluids engineering
    • /
    • v.11 no.4 s.35
    • /
    • pp.20-25
    • /
    • 2006
  • In the present study, flow characteristics inside a road tunnel are simulated for the ventilation flows due to jet fan system and flows induces by the traffic. Traffic ventilation is numerically simulated by multiple reference frame. From the results of steady state simulation of tunnel ventilation, it is found that the proper ventilation is achieved by the designed jet fan system along with ventilating flow induced by the traffic. A transient simulation is also performed for the case of vehicle fire in the tunnel reversing the direction of rotation of some fans. The results suggest that the heat and smoke can be controlled by the proper changing of fan operation mode. The present results can be used to design proper ventilation system and effective smoke control system as well.

A Study on Pressure Variation of the Passenger Cabin of Conventional Train for Speed-up (기존선 속도향상을 위한 객실내 압력변동에 관한 연구)

  • 남성원;한기흥
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.521-526
    • /
    • 2000
  • Experimental study is conducted to clarify pressure variation of the passenger cabin of conventional train. These pressure variation may give rise to the ear-discomfort. Generally ear-discomfort has been considered as a problem related to high speed train. Because there is also a good progress to speed-up for conventional line, this isn't only a phenomena related to high speed train any longer. In this study, tile pressure variation of interior, gangway and exterior of saemaeul passenger car is measured using the atmospheric pressure sensors in Honam line. From the results of experiment, the pressure variation per second almost close in upon the limitation in the case of Noryong tunnel. Therefore, to accomplish speed-up for conventional train, it may be necessary to study a serial ventilating and the airtightness of carbody.

  • PDF

Numerical Analysis on HVAC Characteristics of Mugunghwa Passenger Car (무궁화 객차 HVAC 열유동 특성 해석)

  • 남성원
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.514-520
    • /
    • 2000
  • Numerical simulation is conducted to clarify the heat transfer and fluid flow characteristics of HVAC(Heating, Ventilating and Air-Conditioning) for Mugunghwa passenger car. The HVAC system is installed under the floor of carbody. This new HVAC system has a lot of merits in respect of the center of gravity of carbody, flow induced noise and reduction of condensation water etc. The standard k-epsilon turbulent model and SIMPLEC algorithm based on finite volume method are used to solve the physical HVAC model. To assure convergence, QUICK scheme for momentum equation and the first order upwind scheme for turbulent equations are used. From the results of simulation, the temperature and velocity magnitude are also distributed uniformly in the interior of car.

  • PDF

The Measurement of the Indoor Air Quality in Subway (전동차의 실내 공기청정도 측정 평가)

  • So, Jin-Sub;Yoo, Seong-Yeon;Yun, Cha-Jung;Kim, Wan-Jong;Kang, Sung-Hae;Park, Duk-Sin;Cho, Young-Min;Kwon, Soon-Bark;Park, Eun-Young
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1325-1329
    • /
    • 2007
  • Indoor air quality is an important determinant of human health and comfort. However, the complexity of pollution sources and the multitude of parties responsible for creating indoor exposures makes the improvement of air quality difficult. The HVAC(Heating, Ventilating and Air-Conditioning) system is important facility to provide comfortable environment passenger service. The Ministry of Environment is established "Indoor Air Quality Management guidelines in Public Facilities"in December 2006. Hereupon, the train and the subway are included. In this research air quality in the Subway compartment has been measured. As a result, the concentrations of PM10 and $CO_2$ were reached to 93% and 61% of the regulation values, respectively. Thus, the indoor air qualities of subway have been proved that they satisfy the recommended guidelines by the Ministry of Environment.

  • PDF

Efficiency of Photoplasma of HVAC System for Train (철도차량 HVAC시스템의 광플라즈마 성능평가)

  • Han, Hwan-Su;Jeon, Seung-Gie;Park, Tae-Young;Kim, Bong-Sang;Park, Duck-Shin;Kwon, Soon-Bark
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1293-1296
    • /
    • 2007
  • An amenity requirement of the passenger using public traffic is rising continuously, and also The Ministry of Environment established "Indoor air quality management guidelines in public facilities(Dec. 2006)". To satisfy such requirement, the photoplasma device to decrease VOCs(Volatile Organic Compounds) and suspended bacillus is applied to the underframe mounted HVAC(Heating, Ventilating and Air-Conditioning) system for train. Air purifying method of photoplasma device is optical and chemical reaction that UV-light(wavelength less than 280nm) react with catalyst material(TiO2). To analyze the efficiency of photoplasma in this study, we measured the requirement time for toluene to decease down to 0.3ppm after contaminating the passenger cabin for train to toluene 1ppm.

  • PDF

A Model-Based Fault Detection and Diagnosis Methodology for Cooling Tower

  • Ahn, Byung-Cheon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.3
    • /
    • pp.63-71
    • /
    • 2001
  • This paper presents a model-based method for detecting and diagnosing some faults in the cooling tower of healing, ventilating, and air-conditioning systems. A simple model for the cooling tower is employed. Faults in cooling tower operation are detected through the deviations in the values of system characteristic parameters such as the heat transfer coefficient-area product, the tower approach, the tower effectiveness, and fan power. Three distinct faults are considered: cooling tower inlet water temperature sensor fault, cooling tower pump fault, and cooling tower fan fault. As a result, most values of the system characteristics parameter variations due to a fault are much higher or lower than the values without faults. This allows the faults in a cooling tower to be detected easily using above methods. The diagnostic rules for the faults were also developed through investigating the changes in the different parameter due to each faults.

  • PDF

A study on the malodor exhaust in a water closet system (악취 배출 양변기 시스템에 관한 고찰)

  • Kim, Jong-Ho;Suh, Kee-Won;Son, Jong-Won
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.471-477
    • /
    • 2009
  • This study investigated automatic malodor exhaust ventilating methods in a water closet system. Even though these days advanced equipment has been applied into the toilet in a building or house, the odor due to the evacuating the bowels should be carefully removed to maintain clean and pleasant toilet. Therefore, this study thoroughly considered the main causes of the malodor problems and suggested the best applicable methods to the closet system.

  • PDF

Methods of Reducing Noise Levels of the Cross-flow Fans of the Air-conditioners (에어컨 실내기 직교류 홴의 저소음화 방안)

  • Koo, Hyoung-Mo;Choi, Weon-Seok;Lee, Jin-Kyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1416-1422
    • /
    • 2000
  • The cross-flow fans have been widely used to constitute the air moving systems in many air-ventilating and air-conditioning devices. The cross-flow fan system has many design parameters which have crucial influence on the performance and the noise characteristics of the devices. As a result, there are many difficulties in the design stage of the devices and the general design guide has not been sufficiently established yet. This study presents the experimental results of the parametric investigation of some chosen design parameters, which are the shape of the stabilizer, the profile of the scroll casing, and the diffusion angle of the flow exit. The results are expressed as the fan performance and the specific sound pressure level characteristic. These parts have been found to have crucial effects on the system performance/noise characteristics and should be considered with care in the design stage.

  • PDF