• 제목/요약/키워드: value system

검색결과 15,801건 처리시간 0.041초

자동시각검사환경하에서 공정 목표치의 설정 (Determination of Target Value under Automatic Vision Inspection Systems)

  • 서순근;이성재
    • 품질경영학회지
    • /
    • 제29권3호
    • /
    • pp.66-78
    • /
    • 2001
  • This paper deals with problem of determining process target value under automated visual inspection(AVI) system. Three independent error sources - digitizing error, illumination error, and positional error - which have a close relationship with the performance of the AVI system, are considered. Assuming that digitizing error is uniformly or normally distributed and illumination and positional errors are normally distributed, respectively, the distribution function for the error of measured lengths is derived when the length of a product is measured by the AVI system. Then, Optimal target values under two error models of AVI system are obtained by minimizing the total expected cost function which consists of give away, rework and penalty cost. To validate two process setting models, AVI system for drinks filling process is made up and test results are discussed.

  • PDF

무정전전원장치용 단상 전압형 인버터의 출력 LC필터 설계 (Output LC Filter Design of Single Phase Voltage Source Inverter Used for Uninterruptible Power Supply)

  • 민완기;김재식;최재호
    • 전기학회논문지P
    • /
    • 제56권2호
    • /
    • pp.83-89
    • /
    • 2007
  • The LC filter design procedure of the inverter output filter is described. The transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant considering the system controller. By using the closed form of the relation between the filter capacitor value and the system time constant, the capacitor value can be calculated with the given system time constant and vice versa. It is more practical for the implementation of power and control circuit of inverter. And as the effect of the load current to the voltage distortion can be calculated from the closed form, it is possible to analyze the system how much the voltage waveform is distorted in case of the nonlinear load. All the proposed design procedure is verified with the simulation and experimental results.

$RuO_2$계 후막저항체의 미세구조와 전기적성질 (Microstructure and Electrical Properties of $RuO_2$ System Thick Film Resistors)

  • 구본급;김호기
    • 한국세라믹학회지
    • /
    • 제27권3호
    • /
    • pp.337-344
    • /
    • 1990
  • As a function of sintering temperature and time, the electrical properties of ruthenium based thick film resistors were investigated with microstructure. The variatio of resistivity and TCR(temperature coefficient of resistance)trends of sintered speciman at various sintering temperature were different low resistivity paste(Du Pont 1721) from high one(Du Pont 1741). These phenomena are deeply relative to microstructure of sintered film. With increasing the sintering temperature for 1721 system, the electrical sheet resistivity decreased, but again gradually increased above 80$0^{\circ}C$. And TCR trends in 1721 system are all positive. On the other hand the electrical sheet resistivity of 1741 resistor system decreased with sintering temperature. And TCR trends variable according to sintering temperature. TCR of speciman sintered at $700^{\circ}C$ was negative value, and TCR of 80$0^{\circ}C$ sintered speciman coexisted negative and positive value. But in case of speciman sintered at 90$0^{\circ}C$, TCR was positive value. As results of this fact, it was well known that the charge carrier contributied to electrical conduction in 1741 resistor system varied with sintering temperature.

  • PDF

AN INITIAL VALUE METHOD FOR SINGULARLY PERTURBED SYSTEM OF REACTION-DIFFUSION TYPE DELAY DIFFERENTIAL EQUATIONS

  • Subburayan, V.;Ramanujam, N.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제17권4호
    • /
    • pp.221-237
    • /
    • 2013
  • In this paper an asymptotic numerical method named as Initial Value Method (IVM) is suggested to solve the singularly perturbed weakly coupled system of reaction-diffusion type second order ordinary differential equations with negative shift (delay) terms. In this method, the original problem of solving the second order system of equations is reduced to solving eight first order singularly perturbed differential equations without delay and one system of difference equations. These singularly perturbed problems are solved by the second order hybrid finite difference scheme. An error estimate for this method is derived by using supremum norm and it is of almost second order. Numerical results are provided to illustrate the theoretical results.

하이드로릭 마운트가 장착된 지지계의 고유치 해석 (Eigen-Analysis of Engine mount system with Hydraulic Mount)

  • 고강호;김영호
    • 소음진동
    • /
    • 제10권5호
    • /
    • pp.800-805
    • /
    • 2000
  • To determine the modal matrix and modal frequency of engine mount system, we most solve so-called eigen-value problem. However eigen-value problem of engine mount system with hydraulic mount can not be solved by general eigne-analysis algorithm because the properties of hydraulic mount vary with frequency. so in this paper the method for modal analysis of rigid body motions of an engine supported by hydraulic mount is proposed. Natural frequencies and mode shapes of this nonlinear system are obtained by using complex exponential method and Laplace transformation method. In time domain, impulse response functions are calculated by (two-sided) discrete inverse Fourier Transformation of forced frequency response functions achieved by Laplace transformation of the differential equation of motion. Considering the fact that frequency response functions synthesized by modal parameters form proposed method are in good agreement with original FRFs, it is proved that the proposed method is very efficient and useful for the analysis of eigne-value problem of hydraulic engine mount system.

  • PDF

산업용 플랜트 및 상업용 시설물 전력계통의 안정도에 대한 연구 (A STABILITY STUDY FOR INDUSTRIAL PLANTS AND COMMERCIAL FACILITIES)

  • 김기택;윤덕로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 전기설비
    • /
    • pp.19-21
    • /
    • 2005
  • The purpose of power system design is, in a word, to provide a good quality of electric power. The design of reliable industrial and commercial power distribution system is important because of the high costs associated with power outage. Three major factors for realization of the purpose are: (1) To hold system frequency at or very close to a specified nominal value(e.g. 60Hz) by control of frequency-effective power. (2) To maintain the correct value of interchange power between power and local generators. (3) To hold system voltage at or very close to a specified nominal value by control of voltage-reactive power. Within the past decade, numbers of industrial and commercial facilities installed with local generation, large motors or both, are increasing. This means that system stability is of concern to a growing number of industrial plant electrical engineers and consultants.

  • PDF

제어기 성능을 고려한 전압형 인버터의 출력 LC필터 설계 (Output LC Filter Design of Voltage Source Inverter Considering the Performance of Controller)

  • 민완기;김재식;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.206-211
    • /
    • 2005
  • The LC filter design procedure of the inverter output filter is described. The transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant considering the system controller. By using the closed form of the relation between the filter capacitor value and the system time constant, the capacitor value can be calculated with the given system time constant and vice versa. It is more practical for the implementation of power and control circuit of inverter. And as the effect of the load current to the voltage distortion can be calculated from the closed form, it is possible to analyze the system how much the voltage waveform is distorted in case of the nonlinear load. All the proposed design procedure is verified with the simulation and experimental results.

  • PDF

성과관리시스템(EVMS) 도입을 위한 원전 건설사업비 관리체계 세분화 방안에 관한 연구 (A Study on the Cost Hierarchical System of Nuclaer Power Plant Construction Project for Introcusting Earned Vaule Management System)

  • 이상현;김우중
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.230-231
    • /
    • 2019
  • The nuclear power plant construction project is large-scale, has various stakeholders and computer system, and is produced and managed a large amount of information. The domestic nuclear power plant construction project has accumulated data based on many years of experience in the system. It has the competitiveness to suggeest alternatives that meet the requirement of the client in the overseas nuclear power plant project. Earned value management, which integrates schedule and cost, is possible to risk management. It was developed the earned value management system considering the the actual data properties and types of the preceding nuclear power plant construction projects. It will be able to increase the nuclaer power plant export competieiveness. Therefore, it was palned to carry out future stuies so that it be able to complement the measure to integrate cost and schedule in consideration of actual data(quantity of activity, etc.).

  • PDF

진공 및 이산화탄소 삼중유리 시스템의 최적 두께 및 열관류율 분석 (Analysis of the Optimal Thickness and the Heat Transmission for the Triple Glazing System with Vacuum and Carbon Dioxide Gaps)

  • 백상훈
    • 토지주택연구
    • /
    • 제11권3호
    • /
    • pp.61-68
    • /
    • 2020
  • Advanced glazing systems with excellent heat transmission values (Ug-Value) have been developed to reduce the energy consumption and the greenhouse gas emission. This study proposes a triple glazing system consisting of gaps with a vacuum and a carbon dioxide gas layer which is one of greenhouse gases. As a fundamental stage, this study is focused on calculating the optimal glazing thickness and the Ug-Value via a computer simulation, Therm & Window package. As the results, it was presented that the optimal thickness of the proposed triple glazing system is 22.2 mm, and the Ug-Value is 0.273 W/㎡·K. If this glazing system is to be applied to buildings, it could not only reduce building energy consumption but could also contribute to the treatment of carbon dioxide gas which is one of greenhouse gases.

가치산정법에 의한 전력품질비용 산정 및 단일화지수의 개발 (Evaluation of Power Quality Cost Based on Value-Based Methodology and Development of Unified Index)

  • 이범;김경민
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1293-1298
    • /
    • 2011
  • This paper presents an Unified Index which can evaluate a performance of a distribution system based on value-based methodology. Reliability cost and voltage sags cost are calculated for each load point using Reliability Sector Customer Damage Function(SCDF). Aging cost is calculated for each load point using Aging SCDF. Power loss cost and operation cost are calculated for the system. By summation of each cost of load point and system, power quality cost can be obtained. Finally, this paper developed an unified index which can show the performance of a distribution system. Presented method has been applied to a real system, the usefulness of the method has been verified.