• Title/Summary/Keyword: value gap

Search Result 1,039, Processing Time 0.032 seconds

Discrimination of Korean Domestic and Foreign Soybeans using Near Infrared Reflectance Spectroscopy (근적외선분광광도계(NIRS)를 이용한 국내산 콩과 수입콩의 판별분석)

  • Ahn, Hyung-Gyun;Kim, Yong-Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.57 no.3
    • /
    • pp.296-300
    • /
    • 2012
  • Discrimination of geographic origin of agricultural products is a important issue in Korea because the price difference between Korean domestic and imported cereals is a key among some reasons. NIRS (Near Infrared Reflectance Spectroscopy) has been applied to classify the geographical origin of soybeans. Total 135 samples (Korean domestic 92 and foreign 43) were used to obtain calibration equation through 400~2,500 nm wavelength. The math treatment with 1st derivative and 4 nm gap and the modified partial least squares(MPLS)regression was outstanding for calibration equation. The standard error of calibration and determination coefficient in calibration set(n=115) was 6.65 and 0.98, respectively. And it showed that the extra 20 samples for validation equation were identified their authentication correctly. This study describes that the application of NIRS would be possible for discrimination of geographical origin between Korean domestic and imported soybeans.

Modified Essex-Lopresti Reduction for the Displaced Intra-articular Calcaneal Fractures (전위된 관절 내 종골 골절에 대한 Essex-Lopresti 변형 정복술)

  • Kwak, Kyoung-Duck;Cho, Hyoun-Oh;Lim, Dae-Hwan;Ahn, Sang-Min;Jang, Jae-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.1
    • /
    • pp.109-114
    • /
    • 2003
  • Purpose: The purpose of this study is to evaluate the effectiveness and indications of the modified Essex-Lopresti reduction in calcaneal fractures. Materials and Methods: We reviewed retrospectively 41 cases of displaced intraarticular calcaneal fractures. The fracture was reduced with Essex-Lopresti technique with modification in compression of the lateral wall with the specially designed compression device instead of the operator's hands. We evaluated the results of treatment by AOFAS scale and the radiographic parameters including the Bohler's angle, calcaneal width, calcaneofibular distance and the congruency of the posterior facet. Results: Boler's angle was restored from 11 to 29.6 degrees on average, heel width was reduced to 112% of contralateral value, the calcaneofibular gap was restored up to 87.9% of contralateral side, and the articular surface of the posterior facet was restored less than 2 mm of step off and less than 2 mm of gap. AOFAS scale averaged 87 points. The quality of reduction was best in Sander's type II fractures. Small sized fragments in type III fractures could not be reduced. The results were better when the reductions were performed within 24 hours of injury. Conclusion: The modified Essex-Lopresti reduction was less invasive, easy to perform, and the results of treatment were similar to those of open reduction; it seemed to be a reasonable alternative for the selected intraarticular calcaneal fractures.

  • PDF

Growth of HgCdTe thin film by the hot-wall epitaxy method (Hot-wall epitaxy 방법에 의한 HgCdTe 박막 성장)

  • 최규상;정태수
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.4
    • /
    • pp.406-410
    • /
    • 2000
  • Using the hot-wall epitaxy method, we grew a $Hg_{1-x}Cd_xTe$ (MCT) thin film in-situ after growing (111) CdTe of 9 $mu \textrm{m}$ as a buffer layer. The value of FWHM of double crystal x-ray diffraction rocking curve was 125 arcsec and the surface morphology was clean with a small roughness of 10 nm. From measuring the photocurrent of the grown MCT thin film, the maximum peak wavelength and the cut-off wavelength were 1.1050 $\mu\textrm{m}$ (1.1220 eV) and 1.2632 $\mu\textrm{m}$ (0.9815 eV), respectively. This peak wavelength corresponds to the peak of the band gap due to the intrinsic transition of the photoconductor. Therefore, the MCT thin film could be used as the photoconducting detector sensing a near-IR wavelength band from 1.0 to 1.6 $\mu\textrm{m}$.

  • PDF

A comparative study of gold UCLA-type and CAD/CAM titanium implant abutments

  • Park, Ji-Man;Lee, Jai-Bong;Heo, Seong-Joo;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.46-52
    • /
    • 2014
  • PURPOSE. The aim of this study was to evaluate the interface accuracy of computer-assisted designed and manufactured (CAD/CAM) titanium abutments and implant fixture compared to gold-cast UCLA abutments. MATERIALS AND METHODS. An external connection implant system (Mark III, n=10) and an internal connection implant system (Replace Select, n=10) were used, 5 of each group were connected to milled titanium abutment and the rest were connected to the gold-cast UCLA abutments. The implant fixture and abutment were tightened to torque of 35 Ncm using a digital torque gauge, and initial detorque values were measured 10 minutes after tightening. To mimic the mastication, a cyclic loading was applied at 14 Hz for one million cycles, with the stress amplitude range being within 0 N to 100 N. After the cyclic loading, detorque values were measured again. The fixture-abutment gaps were measured under a microscope and recorded with an accuracy of ${\pm}0.1{\mu}m$ at 50 points. RESULTS. Initial detorque values of milled abutment were significantly higher than those of cast abutment (P<.05). Detorque values after one million dynamic cyclic loadings were not significantly different (P>.05). After cyclic loading, detorque values of cast abutment increased, but those of milled abutment decreased (P<.05). There was no significant difference of gap dimension between the milled abutment group and the cast abutment group after cyclic loading. CONCLUSION. In conclusion, CAD/CAM milled titanium abutment can be fabricated with sufficient accuracy to permit screw joint stability between abutment and fixture comparable to that of the traditional gold cast UCLA abutment.

Effects of cementless fixation of implant prosthesis: A finite element study

  • Lee, Hyeonjong;Park, Soyeon;Kwon, Kung-Rock;Noh, Gunwoo
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.341-349
    • /
    • 2019
  • PURPOSE. A novel retentive type of implant prosthesis that does not require the use of cement or screw holes has been introduced; however, there are few reports examining the biomechanical aspects of this novel implant. This study aimed to evaluate the biomechanical features of cementless fixation (CLF) implant prostheses. MATERIALS AND METHODS. The test groups of three variations of CLF implant prostheses and a control group of conventional cement-retained (CR) prosthesis were designed three-dimensionally for finite element analysis. The test groups were divided according to the abutment shape and the relining strategy on the inner surface of the implant crown as follows; resin-air hole-full (RAF), resin-air hole (RA), and resin-no air hole (RNA). The von Mises stress and principal stress were used to evaluate the stress values and distributions of the implant components. Contact open values were calculated to analyze the gap formation of the contact surfaces at the abutment-resin and abutment-implant interfaces. The micro-strain values were evaluated for the surrounding bone. RESULTS. Values reflecting the maximum stress on the abutment were as follows (in MPa): RAF, 25.6; RA, 23.4; RNA, 20.0; and CR, 15.8. The value of gap formation was measured from 0.88 to 1.19 ㎛ at the abutment-resin interface and 24.4 to 24.7 ㎛ at the abutment-implant interface. The strain distribution was similar in all cases. CONCLUSION. CLF had no disadvantages in terms of the biomechanical features compared with conventional CR implant prosthesis and could be successfully applied for implant prosthesis.

Characteristics of Diamond-like Carbon Thin Films (다이아몬드성 탄소 박막의 특성)

  • Kang, Sung Soo;Lee, Won Jin;Park, Hae Jong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.193-199
    • /
    • 2000
  • The a-C : H films have been grown on the glass substrate by PECVD method, where plasma was generated with a 60 Hz line power source. The growth rate of films is found to be dependent of the partial pressure of $C_2H_2$. This growth rate is a little higher than that in which $CH_4$ instead of $C_2H_2$ is used. The transmittance is also much higher(95%). The optical energy gap of films is in the range of 1.4~1.8eV depending on the partial pressure of $C_2H_2$. However, this energy gap, which is 1.8eV, is found to be independent of the partial pressure of $C_2H_2$ for the thick films above $2000{\AA}$. The carbonization is checked from peak intensities of D ($sp^3$) and G($sp^2$) peaks in Roman spectra. The hydronization and C-H bonding status in films can also be determined from FTIR results. Both the bonding strength of C-H and the ratio of $sp^3$ to $sp^2$ in bonding are found to be slightly dependent of partial pressure of $C_2H_2$. Judging from above results, we can conclude that the best value for partial pressure of $C_2H_2$ in growing process of thick films is about 13.8%.

  • PDF

Analysis of Differences and Changes in Suicide Rate between Regions (지역 간 자살률 차이와 변화분석)

  • Lee, Yong-Jae;Kim, Kyung-mi;Kim, Hyosim
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.1
    • /
    • pp.530-538
    • /
    • 2020
  • Recently, the suicide rate problem in Korea is very serious. Local governments are pushing various policies to lower suicide rates. The purpose of this study is to assess the difference in the suicide rate among regions and to identify the trend of change by concentration index(CI). The major findings are as follows. First, county suicide rate was the highest in the last 20 years and the lowest in the city. The low suicide rate in urban areas continues. Second, suicide rates are increasing in all regions. But the gap between the district and the county was decreasing. The difference in suicide rates between urban and rural areas is decreasing. Third, the suicide rate concentration index was negative for all 20 years. Suicide rates in low-density farming and fishing villages. Fourth, the absolute value of the concentration index has been continuously decreasing for 20 years. The gap between suicide and rural areas is decreasing. Therefore, inter-regional suicide rate is estimated to be leveling up.

An Analysis on the Effect of the Korean Moral Values on Fondness for Game Users: Focusing on the Mediating Effect of Generation (한국의 도덕 가치관이 게이머 호감에 미치는 영향에 대한 분석: 세대의 매개효과를 중심으로)

  • Park, Hyun-Ah;Ryu, Seoung-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.6
    • /
    • pp.294-302
    • /
    • 2018
  • The regulation of the game industry by the Korean government is closely related to the specific regulatory behavior from their parents' generation regarding gaming behavior of their children. This is because there exists a gap in terms of digital culture experience between parents and children. This study examined the differences in how moral values affect the awareness or perceptions of the game users. In the results, the norm conformity was found to have a negative influence on the fondness for game users. Age was also shown to have a negative influence on the fondness for the game users. Based on these findings, we also found the mediating effect of age existed specifically with regard to the relation of norm conformity and the fondness for the game users. The results suggest that the game industry promotion policies of Korea should change their existing targets from focusing on everyone to just the elderly.

Science & Engineering Degrees and Human Resource Element Value Estimation in Technology Jobs : the US Case (기술직에서 이공계학위와 인적자원요소의 가치평가 : 미국사례)

  • Lee, Sae Jae;Lee, Hyun Soo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.4
    • /
    • pp.221-229
    • /
    • 2017
  • In the international businesses human resource elements acquired in different countries might have different values in varied industries due to the different quality of education and experiences in the original countries. Using selection models to evaluate expected values in earnings equation of human resource elements such as education and experiences etc. acquired in sending countries, system equations are expanded to examine also the values of science and engineering degrees in technology jobs with selectivity bias correction. This paper used the US census survey data of 2015 on earnings, academic degrees, occupations etc. The US has long maintained the policy of accepting more STEM workers than any other countries and helped maintaining own technological leadership. Assuming per capita GDP gap between the sending country and the US downgrades immigrant human resource quality, it rarely affects occupational selection but depresses earnings on average by two or more years' worth of education. Immigrant quality index in the sense of GDP gap appears to be a valid tool to assess the expected earnings of the worker with. Engineering degrees increase significantly the probability of selecting not only engineering jobs but also general management jobs, as well as increasing the expected earning additionally over nine years'worth of education. Getting a technology job is additionally worth about four years of education. Economics and business degrees are worth additionally almost six years of education but humanities degrees depress expected earnings. Since years after immigration does not very fast enhance earnings capacity, education level and English language ability might be more useful criteria to expect better future earnings by.

A new manufacturing method of all ceramic restoration using alumina tape and presentation of clinical cases

  • Oh, Nam-Sik;Kim, Eui-Seong;Lee, Keun-Woo;Han, Jung-Suk;Kim, Dae-Joon;Lee, Myung-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.6
    • /
    • pp.800-805
    • /
    • 2000
  • In an effort to facilitate fabrication procedure of all ceramic crowns, a novel preparation method for all ceramic crown using alumina tape was developed. The alumina tape having a uniform thickness was cast by using Doctor blade method. The physical properties of newly introduced alumina tape has biaxial flexure strength of $500\sim600MPa$. The value of toughness is $3.18\sim3,28MPa.m^{1/2}$ which corelates with fracture and the linear shrinkage rate of the alumina tape is 0.44% during core production. The marginal fitness of the alumina tape all-ceramic restoration with $90{!`}$shoulder margin had average marginal discrepancy at $78.3{\S}$ > and average marginal gap at $44.4{\S}$ >. At the marginal preparation of $135{!`}$deep chamfer, the average marginal discrepancy at $82.1{\S}$ > and the average marginal gap at $40.2{\S}$ > had been reported. This fabrication procedure of all ceramic crowns with alumina tapes is easier and less technical sensitive for dental technicians. After restoration with new all ceramic crowns we followed the patients 2 years later, there were no complications as porcelain fractures or periodontal disease. We had good esthetic clinical results with new all ceramic crowns.

  • PDF