• Title/Summary/Keyword: validity-reliability

Search Result 3,265, Processing Time 0.031 seconds

Reliability and Validity of the Clinical Judgment Rubric on Simulation Practice with a Post-operative Rehabilitation Case (수술 후 재활 사례에 적용한 임상 판단력 평가도구의 신뢰도 및 타당도)

  • Oh, Hye Kyung
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.18 no.2
    • /
    • pp.145-152
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the reliability and validity of the clinical judgement rubric on simulation practice with a post-operative rehabilitation case. Methods: Methodological study design was used to evaluate the reliability and validity of the clinical judgement rubric on simulation practice. The participants were 35 students in a college of nursing. Results: There were showed reliability and validity of the clinical judgement rubric on simulation practice with a post-operative rehabilitation case. In terms of internal consistency, the Cronbach's ${\alpha}$ for all columns was .821. Factor analysis showed that planning, intervention and evaluation domains with Eigen values of 69.87% were bound, unlike the original tool where four factors including noticing, interpretation, responding and reflecting domains were bound. Convergent validity was established by the correlation between the total clinical judgement score and critical thinking disposition before and after simulation practice. Discriminative validity was established by the correlation between the total clinical judgement score and simulation effectiveness score. Conclusion: The findings of this study suggested that clinical judgement rubric on simulation practice is reliable. Repeated studies are needed to objectively evaluate the clinical judgement rubric of simulation practice for applying various clinical situations.

Validity and Reliability of the Korean Version of the Families' Importance in Nursing Care-Pediatric Nurses' Attitudes Instrument

  • Oh, Jina;Kim, Yae Young;Yoo, So Yeon;Cho, Haeryun
    • Child Health Nursing Research
    • /
    • v.24 no.3
    • /
    • pp.274-286
    • /
    • 2018
  • Purpose: This study aimed to test the validity and reliability of the Korean version of the Families' Importance in Nursing Care-Nurses' Attitudes (FINC-NA) instrument developed by Saveman et al. Methods: The 222 pediatric nurses' data were collected from 13 hospitals in South Korea and were analyzed using descriptive statistics, exploratory factor analysis, the Pearson correlation coefficient, and the Cronbach's ${\alpha}$ in SPSS software. The AMOS program was used to conduct confirmatory factor analysis of construct validity. Results: Of the 26 initial items, 24 were ultimately selected after evaluating content validity, construct validity, and reliability. The following 6 factors were included in the Korean version of the Families' Importance in Nursing Care-Pediatric Nurses' Attitudes (KFINC-PNA): family as a 'conversational partner', 'participant in care', 'supporter for the nurse', 'burden', 'recipient of empowerment', and 'its own resource'. Conclusion: The KFINC-PNA was partially modified to explain differences in language and culture, but its validity and reliability were verified. Pediatric nurses' attitudes can be assessed using the KFINC-PNA, and adjustments to the care of hospitalized children and their families can be made based on these items. We recommend developing and verifying intervention methods that will improve family-centered care for hospitalized children and their families.

Validity and Reliability of a Service Orientation Scale for Health Care Organization (의료기관의 서비스지향성 측정도구의 신뢰도와 타당도 평가)

  • Lee, Myung Ha;Park, Sook Kyoung;Lee, Ok Joo
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.20 no.4
    • /
    • pp.362-372
    • /
    • 2014
  • Purpose: The purpose of this research was to develop and test the validity and reliability of the Service Orientation Scale for Health Care Organization. Methods: The Service Orientation Scale for Health Care Organization, $SERV^*OR$, was developed through forward-backward translation methods. Internal consistency and reliability, construct and criterion validity were calculated using SPSS Statistics WIN 17.0. Survey data were collected from 283 clinical nurses in a general hospital in J province. Results: The Service Orientation Scale for Health Care Organization showed reliable internal consistency with Cronbach's ${\alpha}$'s for the total scale ranging from .85~.91. Factor loading of the 30 items on four sub-scales ranged from .67~.83. The sub scales were named service leadership, service system, customer focus, and service control. Item convergent and discriminant validity were also established for the Service Orientation Scale for Health Care Organization. Criterion validity showed a significant correlation with customer orientation. Conclusion: The findings of the study demonstrate that the Service Orientation Scale for Health Care Organization has satisfactory construct and criterion validity, and reliability and can be used to measure service orientation.

Validity and Reliability of the Turkish Version of the COVID Stress Scale

  • Demirgoz Bal, Meltem;Dissiz, Melike;Bayri Bingol, Fadime
    • Journal of Korean Academy of Nursing
    • /
    • v.51 no.5
    • /
    • pp.525-536
    • /
    • 2021
  • Purpose: The aim of this study was to assess the Turkish adaptation of the COVID Stress Scale (CSS) on the basis of determining the stress caused by the coronavirus disease (COVID-19) pandemic, and to test its validity and reliability. Methods: The English CSS was translated into Turkish using forward and backward translation. Data were collected online from 360 participants. Construct validity was evaluated using confirmatory factor analysis, exploratory factor analysis, and content validity. Pearson product-moment correlation, Cronbach's alpha reliability coefficient, and test-retest methods were used to evaluate reliability. Results: The Turkish version of the CSS has 36 items consistent with the original scale and has five factors: COVID danger and contamination, socioeconomic consequences of COVID, COVID xenophobia, traumatic stress due to COVID, and compulsive checking for COVID. The construct validity of the Turkish version of the CSS was verified by the adjusted goodness of fit index > .85, and comparative fit index > .95. The content validity index of each item was 91%. The corrected item-total correlations of the scale ranged from .51 to .89. Internal consistency was reliable, with a Cronbach's α of .93. Conclusion: The Turkish version of the CSS is valid and reliable. It can be used as a measurement tool for the assessment of COVID-related stress.

Assessing Reliability and Validity of an Instrument for Measuring Resilience Safety Culture in Sociotechnical Systems

  • Shirali, Gholamabbas;Shekari, Mohammad;Angali, Kambiz Ahmadi
    • Safety and Health at Work
    • /
    • v.9 no.3
    • /
    • pp.296-307
    • /
    • 2018
  • Background: Safety culture, acting as the oil necessary in an efficient safety management system, has its own weaknesses in the current conceptualization and utilization in practice. As a new approach, resilience safety culture (RSC) has been proposed to reduce these weaknesses and improve safety culture; however, it requires a valid and reliable instrument to be measured. This study aimed at evaluating the reliability and validity of such an instrument in measuring the RSC in sociotechnical systems. Methods: The researchers designed an instrument based on resilience engineering principles and safety culture as the first instrument to measure the RSC. The RSC instrument was distributed among 354 staff members from 12 units of an anonymous petrochemical plant through hand delivery. Content validity, confirmatory, and exploratory factor analysis were used to examine the construct validity, and Cronbach alpha and test-retest were employed to examine the reliability of the instrument. Results: The results of the content validity index and content validity ratio were calculated as 0.97 and 0.83, respectively. The explanatory factor analysis showed 14 factors with 68.29% total variance and 0.88 Kaiser-Meyer-Olkin index. The results were also confirmed with confirmatory factor analysis (relative Chi-square = 2453.49, Root Mean Square Error of Approximation = 0.04). The reliability of the RSC instrument, as measured by internal consistency, was found to be satisfactory (Cronbach ${\alpha}=0.94$). The results of test-retest reliability was r = 0.85, p < 0.001. Conclusion: The results of the study suggest that the measure shows acceptable validity and reliability.

Reliability and Validity of Measurement Using Smart Phone-Based Goniometer on Pelvic Tilting Angle in Standing and Sitting Position

  • Ha, Sung-Min;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.1
    • /
    • pp.35-39
    • /
    • 2019
  • Purpose: The purpose of this study was to assess the intra-rater and inter-rater reliability and validity of pelvic tilting angle measurements using a smart phone-based inclinometer (Clino) compared to a palpation meter (PALM) in the standing and sitting position. This study used an interchangeable method with Clino to measure the pelvic tilting angle in the standing and sitting positions. Methods: Twenty healthy subjects were recruited. Measurements of the pelvic tilting angle in the standing and sitting positions were obtained by two examiners using the Clino and PALM. A resting session was conducted 10 minutes later to assess the intra and inter rater reliability. To assess validity of the measurement using Clino, a PALM was used as the gold standard. The intra-class correlation coefficient (ICC) was used to determine the intra and inter rater reliability of Clino and a PALM. To assess the validity, the Pearson correlation coefficients were used for two measurement techniques to measure the pelvic tilting angle in the standing and sitting positions. The statistical significance was set to ${\alpha}=0.05$. Results: Measurements of the pelvic tilt had high inter-rater reliability in the standing (ICC=0.82) and sitting (ICC=0.88) positions using Clino and intra-rater reliability in the standing (ICC=0.87) and sitting (ICC=0.91) positions using Clino. Measurements of the pelvic tilt had high validity by a comparison of PALM and Clino in the standing (r=0.83) and sitting (r=0.89) positions (p<0.05). Conclusion: The use of Clino can be recommended as a tool to replace the PALM and measure the pelvic tilt angle in the standing and sitting positions while maintaining the clinical reliability and validity.

A Study on the Validity and Test-retest Reliability of the Measurement of the Head Tilt Angle of the Smart Phone Application 'KPIMT Torticollis Protractor'

  • Seong Hyeok Song;Ji Su Park;Ki Yeon Song;Ki Hyun Baek;Seung Hak Yoo;Ju Sang Kim
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.6
    • /
    • pp.177-184
    • /
    • 2023
  • Purpose: The purpose of this study was to compare the concurrent validity and test-retest reliability of 'KPIMT Torticollis Protractor', a smart phone and I-pad application for convenient range of motion measurement, and 'Image J', an analysis software with high reliability and validity, according to head tilt and active cervical rotation angle. This was done to determine the clinical utility of 'KPIMT Torticollis Protractor'. Methods: Head tilt and active cervical spine rotation angles of 40 children with congenital muscular torticollis were measured using Image J and KPIMT Torticollis Protractor, respectively. The level of concurrent validity and inter-rater and intra-rater reliability between the two measurement methods were analyzed. Results: For forty participants, the concurrent validity between Image J and KPIMT Torticollis Protractor showed very high validity with ICC of ICC 0.977 (0.995-0.999), 0.994 (0.994-0.998), CVME% 0.71-0.72%, SEM% 0.31-0.34%, MDC% 0.86-0.94%. The test-retest intra-rater reliability showed very high reliability ICC 0.911 (0.911-0.966), CVME% 0.71%, SEM% 0.34-0.36%, MDC% 0.81-0.94%. The test-retest inter-rater showed very high reliability ICC 0.936 (0.933-0.957), CVME% 0.70%, SEM% 0.34-0.35%, MDC% 0.81-0.83%. Conclusion: The KPIMT Torticollis Protractor, a smart phone and IPD application, is a highly reliable and valid device for angle measurement in children with congenital myotonia and can be easily used in clinical practice.

The Reliability and Validity of the Passive Lumbar Extension Test and the Prone Instability Test (수동적 요추 신전 검사와 엎드린 상태에서 요추 불안정성 검사의 신뢰도와 타당도)

  • Sa, Jae-Min;Kim, Sun-Yeop
    • Physical Therapy Korea
    • /
    • v.18 no.3
    • /
    • pp.85-93
    • /
    • 2011
  • The purpose of this study was to establish the reliability and validity of the passive lumbar extension (PLE) test and prone instability test (PIT). Thirty-three subjects (14 males, 19 females) with lower back pain enrolled in the study and the subjects were divided into 2 groups (positive and negative instability groups) on the basis of radiographies of flexion and extension. Reliability was determined by the kappa coefficient and validity was examined using calculated sensitivity, specificity, and the likelihood ratio. The results showed that the reliability of the PLE test was higher than the PIT (intra-rater reliability: k=.86 and k=.81, interrater reliability: k=.65 and k=.62) and the validity of the PLE test was also higher than the PIT (sensitivity: 91% and 62%, specificity: 95% and 85% positive likelihood ratio: 20.00 and 4.10, negative likelihood ratio: .10 and .45). In conclusion, we think that the PLE test was a more reliable and valid method for lumbar instability than the PIT.

The Validity and Reliability of a Korean Version of the Summary of Diabetes Self-Care Activities Questionnaire for Older Patients with Type 2 Diabetes (제2형 당뇨노인을 대상으로 한 당뇨 자가 관리 측정도구(The Summary of Diabetes Self-Care Activities Questionnaire, SDSCA) 한국어 버전의 타당도와 신뢰도 검증)

  • Chang, Sun-Ju;Song, Mi-Soon
    • Korean Journal of Adult Nursing
    • /
    • v.21 no.2
    • /
    • pp.235-244
    • /
    • 2009
  • Purpose: This research was carried out to evaluate the validity and reliability of the Korean version of the Summary of Diabetes Self-Care Activities Questionnaire (SDSCA) for Korean older adults with type 2 diabetes. Methods: Translation and back-translation were performed to develop the Korean version of the SDSCA. Then the Korean version SDSCA was applied to a sample of 112 older adults who had participated in diabetes self management education in Seoul. The internal consistency and the test-retest reliability were examined to test the reliability. Factor analysis was used to examine the construct validity. Results: The internal consistency measured with Cronbach's alpha was .77 and the total test-retest reliability was .68 with items ranging from .21 to 1.00. As the result of the factor analysis, six factors -foot care, diet, exercise, blood sugar test, medication, and smoking- were revealed as the original instrument subcategories. These six factors explained 81.17% of total variance. Conclusion: The reliability and validity of the Korean version SDSCA Questionnaire was supported for use in older patients with type 2 diabetes in Korea.

  • PDF

Validity and Reliability of the Korean Version of the Observable Indicators of Nursing Home Care Quality Evaluation Instrument (한국형 노인요양시설 질 관찰평가도구의 타당도와 신뢰도 분석)

  • Lee, Ji-A
    • Journal of Korean Academy of Nursing
    • /
    • v.38 no.3
    • /
    • pp.474-482
    • /
    • 2008
  • Purpose: The purposes of this study were; 1) to test the validity and reliability of the Korean version of Rantz's Observable Indicators of Nursing Home Care Quality Instrument (ONHQ) and 2) to evaluate the quality of Korean nursing homes. Methods: The study employed a three-phase methodological research design. 1) The original instrument of Rantz's. ONHQ was translated into Korean and modified by Korean nursing home experts. 2) A pilot study using the modified instrument was done in 20 nursing homes to examine inter-rater reliability. 3) The validity and reliability were tested.in 98 nursing homes. Results: Seven factors were extracted through factor analysis: 'communication', 'care delivery', 'grooming', 'odor, 'environment-basics', 'environment-access', and 'environment-homelike'. These factors explained 86.07% of the total variance. Cronbach's alpha coefficient of the 30 items was .97 indicating a high internal consistency of the instrument. Inter-rater reliability according to Kappa was .82. The average score of nursing home quality was 112.07 indicating an average range of quality level. Conclusion: The Korean version of the ONHQ was identified as a tool with a high degree of validity and reliability. This tool can be effectively used to assess the quality of nursing homes by professions as well as family members.