• Title/Summary/Keyword: validity index

Search Result 901, Processing Time 0.025 seconds

The Korean Repeatable Battery for the Assessment of Neuropsychological Status-Update : Psychiatric and Neurosurgery Patient Sample Validity

  • Park, Jong-Ok;Koo, Bon-Hoon;Kim, Ji-Yean;Bai, Dai-Seg;Chang, Mun-Seon;Kim, Oh-Lyong
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.1
    • /
    • pp.125-135
    • /
    • 2021
  • Objective : This study aimed to validate the Korean version of the Repeatable Battery for the Assessment of Neuropsychological Status Update (K-RBANS). Methods : We performed a retrospective analysis of 283 psychiatric and neurosurgery patients. To investigate the convergent validity of the K-RBANS, correlation analyses were performed for other intelligence and neuropsychological test results. Confirmatory factor analysis was used to test a series of alternative plausible models of the K-RBANS. To analyze the various capabilities of the K-RBANS, we compared the area under the receiver operating characteristic (ROC) curves (AUC). Results : Significant correlations were observed, confirming the convergent validity of the K-RBANS among the Total Scale Index (TSI) and indices of the K-RBANS and indices of intelligence (r=0.47-0.81; p<0.001) and other neuropsychological tests at moderate and above significance (r=0.41-0.63; p<0.001). Additionally, the results testing the construct validity of the K-RBANS showed that the second-order factor structure model (model 2, similar to an original factor structure of RBANS), which includes a first-order factor comprising five index scores (immediate memory, visuospatial capacity, language, attention, delayed memory) and one higher-order factor (TSI), was statistically acceptable. The comparative fit index (CFI) (CFI, 0.949) values and the goodness of fit index (GFI) (GFI, 0.942) values higher than 0.90 indicated an excellent fit. The root mean squared error of approximation (RMSEA) (RMSEA, 0.082) was considered an acceptable fit. Additionally, the factor structure of model 2 was found to be better and more valid than the other model in χ2 values (Δχ2=7.69, p<0.05). In the ROC analysis, the AUCs of the TSI and five indices were 0.716-0.837, and the AUC of TSI (AUC, 0.837; 95% confidence interval, 0.760-0.896) was higher than the AUCs of the other indices. The sensitivity and specificity of TSI were 77.66% and 78.12%, respectively. Conclusion : The overall results of this study suggest that the K-RBANS may be used as a valid tool for the brief screening of neuropsychological patients in Korea.

Development and validation of a novel screening instrument to prioritize the orthodontic referral of developing malocclusion in children: The index for interceptive orthodontics referral

  • Saraswathy Devi Sinniah;Annapurny Venkiteswaran;Najiyatu Nazihah Zakaria
    • The korean journal of orthodontics
    • /
    • v.53 no.2
    • /
    • pp.116-124
    • /
    • 2023
  • Objective: The absence of a guideline to refer to developing malocclusions appropriately, may be a contributing factor to the inadequacy of timely interceptive orthodontics provision. This study aimed to develop and validate a new orthodontic grading and referral index to be used by dental frontliners to prioritize the orthodontic referral of developing malocclusion in children based on its severity. Methods: A cross-sectional study involving clinical assessment with 413 schoolchildren aged between 8.1 and 11.9 years was conducted in 2018. All the presenting malocclusion was listed and graded based on a few dental guidelines to produce the draft index. The validity and reliability of the draft index were tested using twenty study models. Face and content validation was carried out using the content validation index and Modified Kappa Statistics. Results: Fourteen dental and occlusal anomalies were identified as components of malocclusion and three grades of referral (monitor, standard, urgent) were included in the final index. The scale-level content validity index average value of 0.86 and 0.87 was obtained for content and face validation, respectively. There was moderate to excellent agreement in the Modified Kappa Statistics for both validations. Excellent inter- and intra-assessor agreement was obtained. The new index displayed valid and reliable scores. Conclusions: The Index for Interceptive Orthodontics Referral was developed and validated for the dental frontliners to identify and prioritize the developing malocclusion in children based on its severity and refer for orthodontic consultation to increase the possibility for interceptive orthodontics.

The comparison of Ergonomic Workload Stress Index (EWSI) among the different workload assessment techniques (작업 스트레스 산정기법들의 비교분석)

  • 정화식;김동묵
    • Korean Management Science Review
    • /
    • v.12 no.1
    • /
    • pp.61-77
    • /
    • 1995
  • The Ergonomic Workload Stress Index (EWSI) was developed to predict the existence and level of the ergonomic workload stress in the workplace. To determine the validity of model, the values of the EWSI and two other similar techniques, Job Severity Index (JSI) and Physical Work Stress Index (PWSI) were evaluated in two actual industrial environments. The results from the validation study provide further substantial evidence that two techniques, JSI and PWSI, which have similar objective considerations, are significantly associated with the value of the EWSI among the employees participating in the experimentation.

  • PDF

A Study on Standardization of Measuring Time for Heart Rate Variability (심박변이도(心搏變移度)의 측정시간(測定時間) 표준화(標準化) 연구(硏究))

  • Kim, Kyu-Tae;Park, Young-Jae;Park, Young-Bae;Oh, Hwan-Sub
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.10 no.2
    • /
    • pp.88-103
    • /
    • 2006
  • Objectives : We performed this study to search the best time for HRV measuring and which index has the validity in a short term measuring. Methods : At first, three examiner measured electrocardiogram(ECG) of 5 people(4 male + 1 female) for 20 minutes in two times. and we devided ten regions (0-5, 5-10, 10-15, 15-20, 0-10, 0-15, 0-20, 5-15, 10-20, 5-20 minutes). After that we finded the HRV index for each regions. To evaluate the validity, we used Gage Repeatability and Reproducibility Study by MINITAB(ver. 13.20). If the '%Study Var' is under 30 and 'Number of Distinct Categories' is over 4, we could tell it has validity(repeatability and reproducibility). Results : 1) The region and HRV index has repeatability and reproducibility, was HF index in 10-15 minutes. The HF index in 15-20 minutes gained 27.41(%Study Var) and 5(Number of Distinct Categories). 2) The HF index in 10-15 minutes has the better reproducibility than repeatability. The value of measurement is under the control. There is consistency among the examiner. The distribution of measurement is not large. There is no interaction between examiner and each people. 3) The HF index in 10-15, 0-10, 0-15, 0-20, 10-20 minutes was not enough to gain the repeatability and reproducibility. But it had some meanings ; %Study Var, Number of Distinct Categories is 32.68, 4 for 10-15 minutes, 34.43, 4 for 0-10 minutes, 34.44, 4 for 0-15 minutes, 33.56, 4 for 0-20 minutes, 32.07, 4 for 10-20 minutes. Conclusions : This study shows the best index of measuring HRV is the HF index in 15-20 minutes. So, from now on we should measure the HRV for 20 minutes and extract the HF index in 15-20 minutes. It must be the standard for HRV measuring.

  • PDF

Guaranteed Stability Margins of the Discrete-Time LQ Optimal Regulator for a Performance Index with Cross-Product Terms

  • Fang, Tae-Hyun;Park, Jae-Weon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.107.4-107
    • /
    • 2001
  • In this paper, the guaranteed stability margins of LQ optimal regulators for a performance index with cross-product terms are suggested in the discrete-time case. An example for the LQ optimal regulator of an inverted pendulum system is given to demonstrate the validity of the suggested stability margins.

  • PDF

Reliability and Validity of the Korean version of autonomy preference index among patients with chronic disease (만성질환자 대상 한국어판 자율성 선호도 도구(K-Autonomy Preference Index)의 신뢰도 및 타당도 검증)

  • Lee, Jihae;An, Bomi
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.8
    • /
    • pp.381-391
    • /
    • 2021
  • The purpose of this study was to validate the Korean version of autonomy preference index (K-API) for chronic patients. Participants were 569 chronic patients. Construct validity and reliability of K-API were examined using exploratory and confirmatory factor analysis, and Cronbach's α test. Original API was translated to Korean, and we conducted contents validity test, and pilot test. The K-API consisted of 10 items divided into two domains: (i) Decision making preference (DMP); (ii) Information seeking preference (ISP). K-API explained 53.4% of autonomy preference; the two-factor structure showed an acceptance fit. Cronbach's α was. 77 for DMP, and. 75 for ISP. Validity and reliability of the K-API were established, and this study provides additional evidence for the usage of the API in Asian region.

Verification of the Reliability and Validity of the Korean Pediatric Patient Classification System and Estimation of Nursing Time Conversion Index (한국형 소아 환자 분류도구의 신뢰도와 타당도 검증 및 간호시간 환산지수 산출 연구)

  • Sim, Mi Young;Park, Ji Sun;Kwon, Mi Kyung;Song, Suk Hee;Kim, Ye Seul;Kang, Min Seo;Lee, Shin Ae;Choi, Eun Seok;Ha, Eun Ju
    • Journal of Korean Clinical Nursing Research
    • /
    • v.28 no.2
    • /
    • pp.185-197
    • /
    • 2022
  • Purpose: This study was performed to verify reliability and validity of the Korean Pediatric Patient Classification System (KPPCS) and estimate nursing time conversion index. Methods: The study was conducted in 9 children's hospital which included various areas and size of bed settings. To verify intraclass correlation reliability and construct validity, staff nurses and nurse managers of 21 wards classified 575 patients according to KPPCS comparing differences by age, days of stay, type of stay and medical department. Direct and indirect nursing time of 575 patients were measured by 284 nursing staffs by stopwatch observation and self reports for 24 hours. Results: KPPCS has 12 categories, 55 nursing activities and 80 criterions. High agreement among nurses (r=.91, p<.001) suggested substantial reliability. Construct validity was verified by comparing differences in age, days of stay, type of stay and medical department (p<.05). The correlation of nursing time and classification score was also statistically significant (r=.59, p<.001). The nursing time conversion index was 10.78 minutes per 1 classification score. The entire patient group were classified to four groups using KPPCS. Conclusion: The findings suggest that KPPCS would be a useful tool for estimating nursing demands related to the complexity of pediatric patients.

Validity and Reliability Tests of Neonatal Patient Classification System Based on Nursing Needs (간호요구 정도에 의한 신생아중환자 분류도구의 타당도 및 신뢰도 검증)

  • Ko, Bum Ja;Yu, Mi;Kang, Jin Sun;Kim, Dong Yeon;Bog, Jeong Hee
    • Journal of Korean Clinical Nursing Research
    • /
    • v.18 no.3
    • /
    • pp.354-367
    • /
    • 2012
  • Purpose: This study was done to verify validity and reliability of a neonatal patient classification system (NeoPCS-1). Methods: An expert group of 8 nurse managers and 40 nurses from 8 Neonatal Intensive Care Units in Korea, verified content validity of the measurement using item level content validity index (I-CVI). The participants were nurses caring for 469 neonates. Data were collected from November 11 to December 14, 2011 and analyzed using descriptive statistics, ANOVA, intraclass correlation coefficient, and K-cluster analysis with PASW 18.0 program. Results: Nursing domains and activities included 8 items with 91 activities. I-CVI was above .80 in all areas. Interrater reliability was significant between two raters (r=.95, p<.001). Classification scores for participants according to patient types and nurses' intuition were significantly higher for the following patients; gestational age (${\leq}29$ weeks), body weight (<1,000 gm), and transfer from hospital. Six groups were classified using cluster analysis method based on nursing needs. Patient classification scores were significantly different for the groups. Conclusion: These results show adequate validity and reliability for the NeoPCS-1 based on nursing needs. Study is needed to refine the measurement and develop index scores to estimate number of nurses needed for adequate neonatal care.

Reliability and Validity of Stroke Impact Scale 3.0 (뇌졸중 영향 척도 3.0의 신뢰도와 타당도)

  • Park, Eun-Young;Choi, Yoo-Im;Kim, Eun-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.293-302
    • /
    • 2019
  • The purpose of this study was to examine the reliability and validity of Stroke Impact Scale 3.0 (SIS 3.0). Here, the SIS 3.0 was completed by 154 stroke patients (mean = 62.7; standard deviation [SD] = 9.43). Construct validity was verified by analyzing the correlation between SIS 3.0 sub-domains, and convergent validity was investigated by analyzing the correlation between the Modified Barthel Index (MBI) and the Mini-Mental State Examination-Korean (K-MMSE) version. The characteristics of each item were analyzed by internal consistency and item discrimination based on the classical item theory. Construct and convergent validity were verified through this study. Although the item i included in the emotion domain showed low item discrimination, all but this item showed high discrimination. Internal consistency was also high in all sub-domains.

Work Ability Index: Psychometric Testing in Aeronautical Industry Workers

  • Maria Eugenia Gonzalez-Dominguez;Elena Fernandez-Garcia;Olga Paloma-Castro;Regina Maria Gonzalez-Lopez;Maria Paz Rivas Perez;Luis Lopez-Molina;Jesus Garcia-Jimenez;Jose Manuel Romero-Sanchez
    • Safety and Health at Work
    • /
    • v.15 no.1
    • /
    • pp.80-86
    • /
    • 2024
  • Background: The Work Ability Index (WAI) is an instrument that measures work ability. The wide dispersion of the WAI internationally has led to its adaptation for use in different countries. This study aimed to evaluate the psychometric properties of the Spanish version of the WAI. Methods: A methodological design was used over an opportunistic sample of 233 workers in the aeronautical industry in Spain. Reliability was evaluated through internal consistency. Factorial validity, known groups, and convergent validity were tested. Results: The Cronbach's alpha and item-total correlation indicated an adequate internal consistency. The confirmatory factor analysis, performed to evaluate the factorial validity, found adequate fit indices for a two-factor solution with a high correlation between the factors. Factor 1, "Subjectively estimated work ability and resources", was composed of 3 subscales and factor 2, "Ill-health-related", of 2 subscales. Subscales 4 and 6 had loading in both factors. Workers under 45 years of age obtained higher significant scores than older ones. Convergent validity was also evidenced since WAI was highly correlated with self-assessment of health status. Conclusions: The Spanish version of the WAI has shown evidence of reliability and validity in this study, supporting its use in individual and collective health surveillance by occupational health professionals. The factorial solution that was found has previously been reported in another international context. However, further research is needed to resolve the discrepancies detected in the role of some subscales between other national and international studies.