• Title/Summary/Keyword: vacuum tube

Search Result 236, Processing Time 0.029 seconds

Study of oxidation behavior and tensile properties of candidate superalloys in the air ingress simulation scenario

  • Bin Du;Haoxiang Li;Wei Zheng;Xuedong He;Tao Ma;Huaqiang Yin
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.71-79
    • /
    • 2023
  • Air ingress incidents are major safety accidents in very-high-temperature reactors (VHTRs). Air containing a high volume fraction of oxygen may cause severe oxidation of core components at the VHTR, especially for the significantly thin alloy tube wall in the intermediate heat exchanger (IHE). The research objects of this study are Inconel 617 and Incoloy 800H, two candidate alloys for IHE in VHTR. The air ingress accident scenario is simulated with high-temperature air flow at 950 ℃. A continuous oxide scale was formed on the surfaces of both the alloys after the experiment. Because the oxide scale of Inconel 617 has a loose structure, whereas that of Incoloy 800H is denser, Inconel 617 exhibited significantly more severe internal oxidation than Incoloy 800H. Further, Inconel 617 showed a significant decrease in ultimate tensile strength and plasticity after aging for 200 h, whereas Incoloy 800H maintained its tensile properties satisfactorily. Through control experiment under vacuum, we preliminarily concluded that serious internal oxidation is the primary reason for the decline in the tensile properties of Inconel 617.

Study on the Improvement for Measuring Procedures of Volumetric Pressure Plate Extractor (체적압력판추출기의 측정법 개선에 관한 연구)

  • Yoo, Kun-Sun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.4C
    • /
    • pp.185-191
    • /
    • 2010
  • Volumetric pressure plate extractor (VPPE) can be used for measurement of the soil-water characteristic curve in the laboratory using the axis-translation technique. The volume of extracted water from the soil specimen in VPPE can be measured continuously during the test without stoppage of air pressure for the measurements. However, the water volume measurement in VPPE using an air trap, a ballast tube, a burette, and a vacuum device so as to maintain a constant pore-water pressure in the soil specimen, is quite complicated and tedious. In order to improve the measuring problems of VPPE, a modified volumetric pressure plate extractor (MVPPE) was developed and tested on residual soil specimens. In addition, the modified apparatus can measure the volume of the extracted water using both Method A and Method B of ASTM D 6836-02 depending on the range of matric suction. Measuring principles and the improvements of MVPPE and typical results obtained from the tests are discussed in the paper.

Exact Solutions of Plasma Diffusion in a Fine Tube Positive Column Discharge (세관 양광주 방전에서 플라즈마 확산의 완전 해)

  • Jin, D.J.;Jeong, J.M.;Kim, J.H.;Hwang, H.C.;Chung, J.Y.;Cho, Y.H.;Lim, H.K.;Koo, J.H.;Choi, E.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.1
    • /
    • pp.36-44
    • /
    • 2010
  • The ambipolar diffusion equation has been solved in a fine-tube lamp of a few mm in diameter. In the diffusion of radial direction, the plasma diffuses and vanishes away at the glass wall by recombination with the characteristic time of plasma loss is given by $\tau_r\;=\;(r_0/2.4)^2/D_a$. With the radius $r_0{\sim}1\;mm$ and the ambipolar diffusion coefficient $D_a{\sim}0.01\;m^2/s$, the vanishing time is calculated $\tau_r{\sim}10\;{\mu}s$ which corresponds to the least value of frequency 30 kHz for the sustaining the plasma in the operation of high voltage AC-power. In the diffusion of longitudinal z-direction, a high density plasma generated at the area of a high voltage electrode, diffuses into the positive column with the characteristic time $\tau_z{\sim}0.1\;s$. The plasma diffusion velocity at the boundary of high density plasma is $u_D{\sim}10^2\;m/s$ at the time $t{\sim}10^{-6}$ s and the diffusion velocity becomes slow as $u_D{\sim}1\;m/s$ at $t{\sim}10^{-3}\;s$. Therefore, for the long lamp of 1 m, it takes about several seconds for the high density plasma at the area of electrode to diffuse through the whole positive column space.

Temperature Analysis for the Point-Cell Source in the Vapor Deposition Process

  • Park, Jong-Wook;Kim, Sung-Cho;Hun Jung
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.9
    • /
    • pp.1680-1688
    • /
    • 2004
  • The information indicating device plays an important part in the information times. Recently, the classical CRT (Cathod Ray Tube) display is getting transferred to the LCD (Liquid Crystal Display) one which is a kind of the FPDs (Flat Panel Displays). The OLED (Organic Light Emitting Diodes) display of the FPDs has many advantages for the low power consumption, the luminescence in itself, the light weight, the thin thickness, the wide view angle, the fast response and so on as compared with the LCD one. The OLED has lately attracted considerable attention as the next generation device for the information indicators. And also it has already been applied for the outside panel of a mobile phone, and its demand will be gradually increased in the various fields. It is manufactured by the vapor deposition method in the vacuum state, and the uniformity of thin film on the substrate depends on the temperature distribution in the point-cell source. This paper describes the basic concepts that are obtained to design the point-cell source using the computational temperature analysis. The grids are generated using the module of AUTOHEXA in the ICEM CFD program and the temperature distributions are numerically obtained using the STAR-CD program. The temperature profiles are calculated for four cases, i.e., the charge rate for the source in the crucible, the ratio of diameter to height of the crucible, the ratio of interval to height of the heating bands, and the geometry modification for the basic crucible. As a result, the blowout phenomenon can be shown when the charge rate for the source increases. The temperature variation in the radial direction is decreased as the ratio of diameter to height is decreased and it is suggested that the thin film thickness can be uniformed. In case of using one heating band, the blowout can be shown as the higher temperature distribution in the center part of the source, and the clogging can appear in the top end of the crucible in the lower temperature. The phenomena of both the blowout and the clogging in the modified crucible with the nozzle-diffuser can be prevented because the temperature in the upper part of the crucible is higher than that of other parts and the temperature variation in the radial direction becomes small.

Relationship Between Microstructure and Electrical Resistivity of Sb-InSb-and Sn-Bi Eutectic Alloys (Sb-InSb및 Sn-Bi공정합금의 미세조직과 전기비저항)

  • Seok, Myeong-Jin;Choe, Gil-Hyeon;Lee, Dong-Cheol;Mun, In-Hyeong
    • Korean Journal of Materials Research
    • /
    • v.4 no.1
    • /
    • pp.97-106
    • /
    • 1994
  • The dependence of the electrical resistivity on the eutectic composition and growth rates was investigated in the unidirectionally solidified Sb-InSb and Sn-Bi eutectic alloy systems, which were generally classified into the groups of f-f and nf-f eutectic system. Sb-InSb alloys containing 26-34wt.% In and Sn-Bi alloys containing 53-65wt.%Bi were prepared in vacuum sealed in a silica tube, and then these were unidirectionally solidified. Electrical resistivity of the specimens prepared by cutting the crystal section in parallel with the transverse direction and by cutting in longitudinal direction was measured. As the growth rate increased, the Sb-InSb and Sn-Bi eutectic alloys showed that the resistivity of longitudinal to the growth direction was increased but that of transverse to the growth direction was decreased. In the case of Sb-InSb eutectic alloy, increas~ng the phase boundary area and decreasing the fiber directionallity caused to increase the $p \; \parallel$ , while increasing the phase boundary area increased the $p \; \\perp$ As expected, the eutectic microstructure could be analysed well in terms of electrical resistivity.

  • PDF

Measurement of Electron Temperature and Number Density and Their Effects on Reactive Species Formation in a DC Underwater Capillary Discharge

  • Ahmed, Muhammad Waqar;Rahman, Md. Shahinur;Choi, Sooseok;Shaislamov, Ulugbek;Yang, Jong-Keun;Suresh, Rai;Lee, Heon-Ju
    • Applied Science and Convergence Technology
    • /
    • v.26 no.5
    • /
    • pp.118-128
    • /
    • 2017
  • The scope of this work is to determine and compare the effect of electron temperature ($T_e$) and number density ($N_e$) on the yield rate and concentration of reactive chemical species ($^{\bullet}OH$, $H_2O_2$ and $O_3$) in an argon, air and oxygen injected negative DC (0-4 kV) capillary discharge with water flow(0.1 L/min). The discharge was created between tungsten pin-to pin electrodes (${\Phi}=0.5mm$) separated by a variable distance (1-2 mm) in a quartz capillary tube (2 mm inner diameter, 4 mm outer diameter), with various gas injection rates (100-800 sccm). Optical emission spectroscopy (OES) of the hydrogen Balmer lines was carried out to investigate the line shapes and intensities as functions of the discharge parameters such as the type of gas, gas injection rate and inter electrode gap distances. The intensity ratio method was used to calculate $T_e$ and Stark broadening of Balmer ${\beta}$ lines was adopted to determine $N_e$. The effects of $T_e$ and $N_e$ on the reactive chemical species formation were evaluated and presented. The enhancement in yield rate of reactive chemical species was revealed at the higher electron temperature, higher gas injection rates, higher discharge power and larger inter-electrode gap. The discharge with oxygen injection was the most effective one for increasing the reactive chemical species concentration. The formation of reactive chemical species was shown more directly related to $T_e$ than $N_e$ in a flowing water gas injected negative DC capillary discharge.

Modeling Study on a Circulatory Hollow-Fiber Membrane Absorber for $CO_{2}$ Separation (이산화탄소 분리를 위한 순환식 중공사 막흡수기에 관한 모델링 연구)

  • Chun, Myung-Suk;Lee, Kew-Ho
    • Membrane Journal
    • /
    • v.5 no.1
    • /
    • pp.35-43
    • /
    • 1995
  • For several years lots of attempts have been made to establish the liquid membrane-based techniques for separations of gas mixtures especially containing carbon dioxide. A more effective system to separate $CO_{2}$ from flue gases, a circulatory hollow-fiber membrane absorber(HFMA) consisting of absorption and desorption modules with vacuum mode, has been considered in this study. Gas-liquid mass transfer has been modeled on a membrane module with non-wetted hollow-fibers in the laminar flow regime. The influence of an absorbent flow rate on the separation performance of the circulatory HFMA can be predicted quantitatively by obtaining the $CO_{2}$ concentration profile in a tube side. The system of $CO_{2}/N_{2}$ binary gas mixture has been studied using pure water as an(inert) absorbent. As the absorbent flow rate is increased, the permeation flux(i.e., defined as permeation rate/membrane contact area) also increases. The enhanced selectivity compared to the previous results, on the other hand, shows the decreasing behavior. It has been found obviously that the permeation flux depends on the variations of pressure in gas phase of desorption module. From an accurate comparison with the results of conventional flat sheet membrane module, the advantageous permeability of this circulatory HFMA can be clearly ascertained as expected. Our efforts to the theoretical model will provide the basic analysis on the circulatory HFMA technique for a better design and process.

  • PDF

Development of the Small Scale Testbed for Running Dynamic Characteristics Analysis of the Capsule Train (캡슐트레인 주행 동특성 분석을 위한 축소 시험장치의 개발)

  • Lee, Jin-Ho;You, Won-Hee;Lee, Kwansup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.643-651
    • /
    • 2020
  • A capsule train runs inside a sub-vacuum tube and can reach very high speed due to the low air resistance. A capsule train uses a superconducting electrodynamic suspension (SC-EDS) method for levitation, which allows for a large levitation gap and does not require gap control. However, SC-EDS has inherent characteristics such as the large gap variation and a small damping effect in the levitation force, which can degrade the running stability and ride comfort. To overcome this, a stability improvement device should be designed and applied based on dynamic analysis. In this study, a 1/10 small-scale testbed was developed to replicate the dynamic characteristics of a capsule train and investigate the performance of stability improvement devices. The testbed is composed of a 6-degree-of-freedom Stewart platform for the realization of bogie motion, a secondary suspension with a running stabilization device, and a carbody. Based on the dynamic similarity law proposed by Jaschinski, the small-scale testbed was manufactured, and a bogie motion algorithm was applied with the consideration of guideway irregularity and levitation stiffness. The experimental results from the testbed were compared with simulation results to investigate the performance of the testbed.

Characteristics of Fe-6.5wt%Si Core Material by Chemical Vapor Deposition Method (화학기상증착에 의한 Fe-6.5wt%Si철심재료의 특성평가)

  • Yun, Jae-Sik;Kim, Byeong-Il;Park, Hyeong-Ho;Bae, In-Seong;Lee, Sang-Baek
    • Korean Journal of Materials Research
    • /
    • v.11 no.6
    • /
    • pp.512-518
    • /
    • 2001
  • It has been well known that 6.5wt% Si steel sheets have excellent magnetic properties such as low core loss. high maximum permeability and low magnetostriction. In this work, we studied a method for producing 6.5wt% Si steel sheets using a chemical vapor deposition (CVD) method. The following is the procedure adopted in this work to produce 6.5wt% Si steel sheets; SiCl$_4$ gas is applied onto a low content-Si steel sheet placed in a tube furnace. Silicon atoms resulted from the decomposition of SiCl$_4$ are permeated through the surface of the steel sheet. Finally, by the diffusion process maintaining it under a high temperature the silicon atoms diffuse uniformly into the sheet. Through this process, 6.5wt% Si steel sheets can be obtained. The manufactured Fe-6.5wt% Si steel sheet with a thickness of 0.5mm exhibited a high frequency core loss (W$_{2}$1k/) of 8.92 W/kg. Its permeability increased from 37,100 to 53,300 at 1 tesular(T). The mechanical properties of the manufactured steel sheets were also estimated and the result showed that the workability was significantly improved by annealing in vacuum at 773k. Increased plastic deformation was also observed prior to fracture and the amount of grain boundary rupture was reduced.

  • PDF

Detecting Potassium Imbalance: Whole Blood vs. Serum (전혈과 혈청에서의 칼륨 이상소견 검사의 차이)

  • Cho, Young-Duck;Choi, Sung-Hyuk;Yoon, Young-Hoon;Park, Sang-Min;Kim, Jung-Youn;Lim, Chae-Seung
    • The Korean Journal of Blood Transfusion
    • /
    • v.23 no.2
    • /
    • pp.162-168
    • /
    • 2012
  • Background: Potassium, the most common cation in the intracellular space, plays a critical role in our physiology. Potassium imbalance may cause life-threatening problems, ranging from general weakness to cardiac arrest due to ventricular fibrillation. For emergency physicians, detection of such derangement within a short period of time is of critical importance. In this study, we wanted to determine whether analysis of whole blood samples can be used as a screening tool for potassium imbalance by comparative analysis of whole blood and serum samples. Methods: Two samples were drawn from 227 patients. The whole blood sample was taken from the radial artery and contained in a commercially available arterial blood collection syringe with a lithium-heparin coating. The serum sample was contained in a commercially available vacuum bottle in a non-additive silicone coated tube and transported to the laboratory. The study population was divided into three groups, patients with normal whole blood potassium, patients with decreased whole blood potassium, and patients with elevated whole blood potassium. Potassium levels for each group were coupled with serum potassium levels and compared. Results: No significant difference in potassium values was observed between whole blood and serum samples (P<0.05). Strong associations were observed among the three groups (normal range, hypokalemia, and hyperkalemia group). Compared to the normal group (r=0.851), the hyperkalemia group showed a stronger association between variables (r=0.897), and the hypokalemia group showed a weaker association (r=0.760). Their correlation coefficients were highly significant (P<0.05). Conclusion: Our study illustrates that point-of-care testing using whole blood with whole blood can be a reliable screening tool when treating patients with suspicious potassium abnormality, especially in hyperkalemia patients.