• Title/Summary/Keyword: vacuum chamber

Search Result 648, Processing Time 0.028 seconds

Gas desorption species and quantity from the hot cathode ionization gauges (열음극 전리 진공게이지의 기체이탈 특성)

  • ;;;I. Arakawa
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.4
    • /
    • pp.201-206
    • /
    • 2003
  • A residual gas analyzer was used to study the outgassing behavior of stainless steel 304 chamber as a function of bake-out temperature up to $235 ^{\circ}C$ and to identify the gas species evolved during turn on and degassing of the three different types of hot cathode ionization gauges. It was found that $H_2O$, CO, and $H_2O$ were the dominent outgassing species in the vacuum chamber during bake-out but finally $H_2$ and CO(mass 28) persisted at room temperature. Dominant outgassing species were also $H_2$ and $H_2O$ while fuming on the ionizations and then $H_2$,$H_2O$ and CO were found to be the main species degassed gauges. It was appeared that the outgassing species and quantity were not agreed to the three different types of hot cathode ionization gauges.

Basic Study for Distillation of Rocket Grade Hydrogen Peroxide (추진제 급 과산화수소 증류를 위한 기초 연구)

  • Chung, Seung-Mi;An, Sung-Yong;Kwon, Se-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.67-70
    • /
    • 2009
  • Because many research using rocket grade peroxide is studied, distillation method for domestic production of rocket grade hydrogen peroxide is required. Distillation methods are very various and divided by feeding method, distillation time, distillation pressure, and so on. Among these, vacuum distillation is a suitable method for hydrogen peroxide. This method can reduce thermal decomposition and reaction with impurities. Distillation condition is determined by Raoult's law. Low vacuum level and vacuum level control are appeared as important problems of the experiment equipment, which are solved by using less leakage vacuum chamber and metering valve.

  • PDF

Vacuum Packaging and Operating Properties of Micro-Tunneling Sensors

  • Park, H.W.;Lee, D.J.;Son, Y. B.;Park, J.H.;Oh, M. H.;Ju, B. K.
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2000.04a
    • /
    • pp.110-110
    • /
    • 2000
  • Cantilever-shaped lateral field emitters were fabricated and their electrical characteristics were tested. As shown in Fig.1, poly-silicon cantilevers were fabricated by the surface micromachining and they were used to the vacuum magnetic field sensors. The tunneling devices were vacuum sealed with the tubeless packaging method, as shown in Fig.2 and Fig.3. The soda-lime glasses were used for better encapsulation, so the sputtered silicon and the glass layers on the soda-lime glasses were bonded together at 1x10$^{-6}$ Torr. The getter was activated after the vacuum sealing fur the stable emissions. The devices were tested outside of the vacuum chamber. Through vacuum packaging, the tunneling sensors can be utilized. Fig.4 shows that the sensor operates with the switching of the magnetic field. When the magnetic field was applied to the device, the anode currents were varied by the Lorentz force. The difference of anode currents can be varied with the strength of the applied magnetic field.

  • PDF

Design and Evaluation of a Rotation Table using Air Bearings for Electron Beam Mastering (전자빔 마스터링을 위한 공기베어링 응용 고진공 회전테이블의 설계 및 진공특성 평가)

  • Khim, Gyung-Ho;Song, Chang-Kyu;Park, Chun-Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.12
    • /
    • pp.132-138
    • /
    • 2008
  • Recently, mastering processes for high density optical disc such as Blu-ray disc rely on electron beams, which are operable in only vacuum. In the mastering process, one of the most important tasks is to design precision stages for providing precise positioning of the works with respect to the source in a high vacuum environment. In this paper, we have developed a precision rotation table usable in the electron beam mastering. The rotation table adopted air bearings for a high positioning repeatability and velocity stability. The air leakage from the air bearings has been minimized by employing the differential exhaust scheme using three steps of air drain. The design parameters such as diameters of exhaust lines, seal lengths, and pumping speeds were decided according to the optimization method using genetic algorithm. The performance on the vacuum level of the rotation table was evaluated experimentally and theoretically. The results indicate that a vacuum level of $10^{-4}$ Pa is achieved with operation of air bearings in a vacuum chamber, which is sufficient for the electron beam mastering.

Vacuum Sealing Technology of the Flat Panel Display by using the Frit Glass Heatable in Vacuum (진공에서 소성 가능한 프릿을 이용한 평판디스플레이 진공실장기술)

  • Kwon, Sang Jik;Yoo, In Sang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.3
    • /
    • pp.181-185
    • /
    • 2016
  • One of the important issues for fabricating the microelectronic display devices such as FED, PDP, and VFD is to obtain a high vacuum level inside the panel. In addition, sustaining the initial high vacuum level permanently is also very important. In the conventional packing technology using a tabulation method, it is not possible to obtain a satisfiable vacuum level for a proper operation. In case of FED, the poor vacuum level results in the increase of operating voltage for electron emission from field emitter tips and an arcing problem, resultantly shortening a life time. Furthermore, the reduction of a sealing process time in the PDP production is very important in respect of commercial product. The most probable method for obtaining the initial high vacuum level inside the space with such a miniature and complex geometry is a vacuum in-line sealing which seals two glass plates within a high vacuum chamber. The critical solution for the vacuum sealing is to develop a frit glass to avoid the bubbling or crack problems during the sealing process at high temperature of about $400^{\circ}C$ under the vacuum environment. In this study, the suitable frit power was developed using a mixture of vitreous and crystalline type frit powders, and a vacuum sealed CNT FED with 2 inch diagonal size was fabricated and successfully operated.

Electron beam welding for Ultra High Vacuum Alminum Chamber (전자빔에 의한 초고진공 알루미늄챔버 용접)

  • 최만호;길계환;최우천
    • Journal of Welding and Joining
    • /
    • v.13 no.1
    • /
    • pp.73-77
    • /
    • 1995
  • 이 글에서는 챔버의 용접에 대해서 기술하였다. 전자빔용접에 의하여 누설률이 1*$10^{-10}$ torr.1/sec 이하로 목표값을 만족하기 때문에 초고진공에 적합한 용접법이다. 챔버는 용접부에 trench 구조를 가져야 진공용접을 하는데 보다 효과적이다. 이것은 지금까지 전자빔 용접에서 시험되지 않은 것이기 때문에 향후 보다 많은 연구가 있으리라고 본다.

  • PDF

Emission Characteristics of 0.7' Monochrome MOSFET-Controlled Field Emission Display in a High Vacuum Chamber

  • Lee, Jong-Duk;Oh, Chang-Woo;Kim, Il-Hwan;Park, Jae-Woo;Park, Byung-Gook
    • Journal of Information Display
    • /
    • v.2 no.3
    • /
    • pp.66-71
    • /
    • 2001
  • MCFEDs (MOSFET-Contoolled Field Emission Displays) were fabricated to evaluate the validity of MCFEA for display application. The electrical properties of FEAs (Field Emitter Arrays), HVMOSFETs (High-Voltage MOSFETs), and MCFEAs (MOSFET-Controlled Field Emitter Arrays) were measured. The extraction gate voltage of the FEAs to obtain the anode current of 10 nA/tip was around 71 V. The breakdown voltages of the HVMOSFETs were above 81 V for all the samples. The I-V characteristics of the MCFEAs showed that the emission currents of the FEAs were well controlled depending on the control gate voltages of the HVMOSFETs. To avoid the harmful effects during the packaging process, the performance of the MCFEDs was evaluated in a high vacuum chamber. The emission images of the MCFEDs were controlled through very-through operation. From the comparison with a conventional FED, it was proven that the poor uniformity of FED could be improved through the integration with HVMOSFET.

  • PDF