• Title/Summary/Keyword: vacuum chamber

Search Result 648, Processing Time 0.023 seconds

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • Analytical Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.

A study on Applicability of VacCAD Simulator

  • Kim, Hyung-Taek;Kim, Kang-Won
    • International journal of advanced smart convergence
    • /
    • v.8 no.4
    • /
    • pp.200-206
    • /
    • 2019
  • In this study, we compared the VacCAD and VacSim(Multi), commercial vacuum simulators, to verify the advantages of VacCAD's efficiency. It was emphasized on immediacy and simplicity of simulation modelling, and characteristics of the pump combinations, pumping down curves, and vacuum materials. First, usability of simulation mechanism was estimated through the modeling schematics and obtained simulation results of each employed simulator were compared to evaluate the applicability in practice. Simulation reliability of each simulator was also probed by comparing the pumping characteristics of commercially available high vacuum systems. In addition, the degree of tolerances on VacCAD was also investigated through pumping down analysis considering outgassing effect due to chamber material variations. The higher effectiveness and expediency of VacCAD than VacSim(Multi) has been presented, and it was expected that the utilization of VacCAD in vacuum applications to be increased.

A Study on the Precool Characteristics of Agricultural Products Using the Water-driven Ejector (수구동 액체이젝터를 이용한 농산물의 예냉특성에 관한 연구)

  • 박영승;이정혜;김호영;김경근
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.45-49
    • /
    • 2001
  • To maintain the freshness of produce, because of stand away between produced and consumer, we need refrigeration system that can supply to consumer at cold chain as soon as gathering. General refrigeration system consist of refrigeration chamber or low temperature store. But the vacuum technology can rapidly refrigeration without refrigerator. This precool system possible to get low precooled temperature, suitable for the fishes, the meat, the vegetables, the fruit etc. Especially get advantage that quality maintain through rapid refrigeration of ferment directly generate heat. Vacuum precool system's principle is that water saturated temperature reduce according to pressure is get to vacuum area, so product temperature reduce as water evaporation at product. In vacuum suction, unit, on early experiment period run the rotary type vacuum pump at purpose pressure, then maintain pressure by water-diven ejector. As the results, cabbage took about 60 minutes to reach from $23.2^{\circ}C$ to $4.5^{\circ}C$at 5mgHg abs.

  • PDF

The Vacuum In-Line Sealing Process for High Efficiency PDP (고효율 PDP 제작을 위한 진공 인라인 실장 공정)

  • Kwon, Sang-Jik;Jang, ChAn-Kyu
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.3 s.12
    • /
    • pp.23-27
    • /
    • 2005
  • The effects of the base vacuum level on a plasma display panel (PDP) produced by the vacuum in-line sealing technology were investigated. The main equipment of the vacuum in-line sealing process consists of the sealing chamber, pumping systems for evacuating, mass flow controller for introducing the plasma gases, and other measuring systems. During the sealing process, the impurity gases were fully evacuated and the panel was prevented from the adsorption of impurity gases. As a result, the brightness increased as the impurity gas density decreased, so we found that the vacuum in-line sealing process was more efficient technology an the conventional sealing process.

  • PDF

Flow Control in the Vacuum-Ejector System (진공 이젝터 시스템의 유동 컨트롤)

  • Lijo, Vincent;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.321-325
    • /
    • 2010
  • Supersonic ejectors are simple mechanical components, which generally perform mixing and/or recompression of two fluid streams. Ejectors have found many applications in engineering. In aerospace engineering, they are used for altitude testing of a propulsion system by reducing the pressure of a test chamber. It is composed of three major sections: a vacuum test chamber, a propulsive nozzle, and a supersonic exhaust diffuser. This paper aims at the improvement of ejector-diffuser performance by focusing attention on reducing exhaust back flow into the test chamber, since alteration of the backflow or recirculation pattern appears as one of the potential means of significantly improving low supersonic ejector-diffuser performance. The simplest backflow-reduction device was an orifice plate at the duct inlet, which would pass the jet and entrained fluid but impede the movement of fluid upstream along the wall. Results clearly showed that the performance of ejector-diffuser system was improved for certain a range of system pressure ratios, whereas the orifice plate was detrimental to the ejector performance for higher pressure ratios. It is also found that there is no change in the performance of diffuser with orifice at its inlet, in terms of its pressure recovery. Hence an appropriately sized orifice system should produce considerable improvement in the ejector-diffuser performance in the intended range of pressure ratios.

  • PDF

A Study on Acustic absorption Efficiency of Vacuum cleaner by Kind of Acustic absorbent (흡음재의 종류에 따른 진공청소기의 흡음성능 특성 연구)

  • Kim, J.H.;Cho, T.J.;Jeong, J.W.;Choi, M.J.;Lee, S.G.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.687-692
    • /
    • 2007
  • Vacuum cleaner, one of those household articles, have easily used in our life. Recently vacuum cleaner tends to be compact and portably with high suction power and low noise. As increasing this suction power, the vibration and noise of vacuum cleaner become important problem. To reduce noise efficiently, it is important to identify the noise and the vibration. This pater is to characterize the noise and vibration of a vacuum cleaner.

  • PDF

Development of Turbo Molecular Pump Vacuum Facility for High Altitude Space Environment Test (고고도 우주환경모사용 터보분자펌프 진공설비 구축)

  • Huh, Hwan-Il;Kim, Min-Jae;Kim, Sung-Su
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.827-829
    • /
    • 2011
  • Vacuum facility is required for high altitude space environment test to develop satellites or space launch vehicles. We, at Chungnam, National University, developed turbo molecular pump vacuum test facility up to $1.0{\times}10-6$ torr to simulate 200 km altitude environment. In this paper, we present some preliminary vacuum performance test results.

  • PDF

Arc Ion Plating Deposition System의 Bias 종류에 따른 TiN 박막의 특성평가

  • Kim, Wang-Ryeol;Park, Min-Seok;Kim, Dae-Yeong;Kim, Hyeon-Seung;Gwon, Min-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.208-208
    • /
    • 2012
  • 최근 환경문제가 많이 제기되면서 친환경적 운송수단인 자전거 개발과 관련하여 다양한 기술개발이 이루어지고 있다. 그 중 고부가가치의 서스펜션 포크의 프레임에 고기능성 표면처리로 Arc ion plating deposition system (AIPDS)을 이용하여 부식, 내마모 특성이 뛰어난 TiN 박막을 증착시켰다. AIPDS는 기존의 arc system과 달리 다원계 소재 코팅 공정조건 확립을 위하여 chamber wall에 2개의 rectangular type sputter source를 장착하고 소재의 pre-treatment 용 linear type ion source를 설치하였다. 장비의 Chamber 중앙에는 pipe형 arc cathode를 설치하였으며, 그 주위를 anode 역할을 하는 copper 코일로 감아 이는 발생한 arc를 target인 cathode 축을 중심으로 방향성을 가지고 회전하여 진행 할 수 있도록 유도 하였다. 이 시스템에서 증착된 TiN 박막은 bias 전압 변화에 따른 박막의 구조 및 물성을 평가하였다. XRD 장비를 통하여 TiN 박막의 상분석을 진행하였고, 마모테스터, 원자현미경, 마이크로 비커스 경도기 등을 이용하여 기계적 특성을 평가하였다.

  • PDF

A Study of Simplified Test Rig for High Altitude Simulation (고고도 모사용 소형시험장치 연구)

  • Lee Ji-Hyung;Oh Jong-Yun;Park Ik-Soo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.4 s.19
    • /
    • pp.133-137
    • /
    • 2004
  • A simplified test rig to simulate high-altitude environments was designed by analyzing the AEDC (Arnolds Engineering Development Center) report regarding simulated altitude testing. The test rig consists of a vacuum chamber, a supersonic nozzle connected to a cold-gas supplier and a diffuser. The preliminary tests were conducted to validate the AEDC design concepts. The test results showed that sub-atmospheric pressure(1.0psia) environments were realized inside the vacuum chamber and the design concepts were confirmed.

Improvement of the Field Emission Stability of Carbon Nanotube Paste Emitter by Post-treatments

  • Choi, Young-Chul;Jeong, Mun-Seok
    • Carbon letters
    • /
    • v.10 no.3
    • /
    • pp.234-238
    • /
    • 2009
  • The field emitters were fabricated by screen-printing of carbon nanotube paste, and their emission stabilities were evaluated. It was found that the emission stability measured in a sealed device is much higher than that measured in a vacuum chamber in spite of similar pressure. This was because oxygen gas was scarcely remained in the sealed device, while the gas is continuously supplied into the vacuum chamber during the stability measurement. It was found that the plasma treatment etched the protruded CNTs, resulting in the uniform height of CNT tips. As a result, the stability was increased remarkably. It was also found that the stability of CNT paste emitter was improved by electrical aging and that the optimum condition for the aging was varied with the size of emitter.