• Title/Summary/Keyword: v-ray

Search Result 2,499, Processing Time 0.031 seconds

A Study on the Fabrication and Physical Properties of $Ca_2SiO_4$:La Thermoluminescent Phosphors ($Ca_2SiO_4$: La 열형광체 제작과 물리적 특성에 관한 연구)

  • Kim, Choung-Mi;Seo, Mi-Kyong
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.4
    • /
    • pp.5-10
    • /
    • 2010
  • The $Ca_2SiO_4$ phosphors doped by La with 0.1 wt%, 0.3 wt%, 0.5 wt%, and 1.0 wt% concentration were prepared by sintering at $1000^{\circ}C$ for 90 minutes in N2 atmosphere. The phosphors were ground in powdered form and were grouped in $100{\mu}m$ size, then the samples had been exposed to low energy X-ray and UV light. The TL glow curves were measured by heating the phosphors at $10^{\circ}C/s$ rate. There was no significantly meaningful correlation between the TL intensity and the doping level. The intensities of the TL peak measured from X-ray irradiated samples doped with 0.1 wt% were relatively strong. The activation energy and the frequency factor were 0.434 ~ 0.516 eV and 0.5 ~ 0.56, respectively. The intensities of the TL peak measured from UV irradiated samples doped with 0.3 wt% were relatively strong. The activation energy and frequency factor were 0.415 ~ 0.477 eV and 0.5 ~ 0.53, respectively. The TL process were found to be the 2nd order for both X-ray and UV irradiation. The TL intensity was increased linearly with the increase of the radiation dose. In summary, the $Ca_2SiO_4 phosphors developed in this study showed good TL characteristics at low energy X-ray and UV light. We believe they will be used as TLDs in near future for personal and environmental radiation detection dosimetry.

Study on Characteristics of Dose Distribution in Tissue of High Energy Electron Beam for Radiation Therapy (방사선 치료용 고에너지 전자선의 조직 내 선량분포 특성에 관한 연구)

  • Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.175-186
    • /
    • 2002
  • The purpose of this study is directly measure and evaluate about absorbed dose change according to nominal energy and electron cone or medical accelerator on isodose curve, percentage depth dose, contaminated X-ray, inhomogeneous tissue, oblique surface and irradiation on intracavitary that electron beam with high energy distributed in tissue, and it settled standard data of hish energy electron beam treatment, and offer to exactly data for new dote distribution modeling study based on experimental resuls and theory. Electron beam with hish energy of $6{\sim}20$ MeV is used that generated from medical linear accelerator (Clinac 2100C/D, Varian) for the experiment, andwater phantom and Farmer chamber md Markus chamber und for absorbe d dose measurement of electron beam, and standard absorbed dose is calculated by standard measurements of International Atomic Energy Agency(IAEA) TRS 277. Dose analyzer (700i dose distribution analyzer, Wellhofer), film (X-OmatV, Kodak), external cone, intracavitary cone, cork, animal compact bone and air were used for don distribution measurement. As the results of absorbed dose ratio increased while irradiation field was increased, it appeared maximum at some irradiation field size and decreased though irradiation field size was more increased, and it decreased greatly while energy of electron beam was increased, and scattered dose on wall of electron cone was the cause. In percentage depth dose curve of electron beam, Effective depth dose(R80) for nominal energy of 6, 9, 12, 16 and 20 MeV are 1.85, 2.93, 4.07, 5.37 and 6.53 cm respectively, which seems to be one third of electron beam energy (MeV). Contaminated X-ray was generated from interaction between electron beam with high energy and material, and it was about $0.3{\sim}2.3\%$ of maximum dose and increased with increasing energy. Change of depth dose ratio of electron beam was compared with theory by Monte Carlo simulation, and calculation and measured value by Pencil beam model reciprocally, and percentage depth dose and measured value by Pencil beam were agreed almost, however, there were a little lack on build up area and error increased in pendulum and multi treatment since there was no contaminated X-ray part. Percentage depth dose calculated by Monte Carlo simulation appeared to be less from all part except maximum dose area from the curve. The change of percentage depth dose by inhomogeneous tissue, maximum range after penetration the 1 cm bone was moved 1 cm toward to surface then polystyrene phantom. In case of 1 cm and 2 cm cork, it was moved 0.5 cm and 1 cm toward to depth, respectively. In case of air, practical range was extended toward depth without energy loss. Irradiation on intracavitary is using straight and beveled type cones of 2.5, 3.0, 3.5 $cm{\phi}$, and maximum and effective $80\%$ dose depth increases while electron beam energy and size of electron cone increase. In case of contaminated X-ray, as the energy increase, straight type cones were more highly appeared then beveled type. The output factor of intracavitary small field electron cone was $15{\sim}86\%$ of standard external electron cone($15{\times}15cm^2$) and straight type was slightly higher then beveled type.

  • PDF

A Study on the Design of a Beta Ray Sensor for True Random Number Generators (진성난수 생성기를 위한 베타선 센서 설계에 관한 연구)

  • Kim, Young-Hee;Jin, HongZhou;Park, Kyunghwan;Kim, Jongbum;Ha, Pan-Bong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.6
    • /
    • pp.619-628
    • /
    • 2019
  • In this paper, we designed a beta ray sensor for a true random number generator. Instead of biasing the gate of the PMOS feedback transistor to a DC voltage, the current flowing through the PMOS feedback transistor is mirrored through a current bias circuit designed to be insensitive to PVT fluctuations, thereby minimizing fluctuations in the signal voltage of the CSA. In addition, by using the constant current supplied by the BGR (Bandgap Reference) circuit, the signal voltage is charged to the VCOM voltage level, thereby reducing the change in charge time to enable high-speed sensing. The beta ray sensor designed with 0.18㎛ CMOS process shows that the minimum signal voltage and maximum signal voltage of the CSA circuit which are resulted from corner simulation are 205mV and 303mV, respectively. and the minimum and maximum widths of the pulses generated by comparing the output signal through the pulse shaper with the threshold voltage (VTHR) voltage of the comparator, were 0.592㎲ and 1.247㎲, respectively. resulting in high-speed detection of 100kHz. Thus, it is designed to count up to 100 kilo pulses per second.

Evaluation of Image Quality When Using Grid During Child Chest X-Ray Examination (소아 흉부검사 시 격자 사용에 따른 영상 화질 평가)

  • Jeung, Seung-Hun;Han, Beom-Hul;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.371-376
    • /
    • 2017
  • Since in case of children, they are sensitive to the radiation compared to the adult and the potential exposure damage lasts longer, the exposure dose should be managed better than for the adult. Therefore, this study was conducted to observe the change in the chest x-ray image by the use of grid, which eliminates the scattering rays but increases the exposure dose during the child chest x-ray examination. As a research method, SNR, CNR and V. Vuichi were measured at 100 cm and 180 cm with the grid varying the kVp to 70, 90 and 110. In addition, SNR, CNR and V. Vuichi were measured fixing 100 cm and 180cm without grid and varying the dose to 6, 8 and 10 mAs. In the results of measuring them by fixing kVp, SNR, VNR and V. Vuichi were represented high when FID is 100cm. And in the results of meaduring them varying mAs, SNR, VNR and V. Vuichi were represented high when FID is 100cm. Currently in our country, the chest x-ray examination is performed at 180 cm. However, as the image is measured high when FID is 100 cm, in case of child, FID is deemed to be 100 cm.

High-Resolution X-Ray Photoelectron Spectroscopy Study of a Sb2Te3 Thin Film with the Polycrystalline Phase (고해상도 엑스선 광전자 분광법을 이용한 다결정구조의 안티몬-테레니움 박막 연구)

  • Lee, Y.M.;Kim, K.;Shin, H.J.;Jung, M.C.;Qi, Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.6
    • /
    • pp.348-353
    • /
    • 2012
  • We investigated chemical states of a $Sb_2Te_3$ thin film with the polycrystalline phase by using high-resolution x-ray photoelectron spectroscopy with synchrotron radiation. The $Sb_2Te_3$ thin film was formed by sputtering. The rhombohedral phase was confirmed by x-ray diffraction. To remove the surface oxide, we performed $Ne^+$ ion sputtering for 1 hour with the beam energy of 1 kV and post-annealing at $100^{\circ}C$ for 5 min in ultra-high vacuum. We obtained the Te and Sb 4d core-levels spectra with the peaks at the binding energies of 40.4 and 33.0 eV, respectively. The full-width of half maximum of both the Te and Sb $4d_{5/2}$ core-levels is 0.9 eV. The Te and Sb core-levels only show a single chemical state, and we also confirmed the stoichiometry of approximately 2 : 3.

A Charge Pump Circuit in a Phase Locked Loop for a CMOS X-Ray Detector (CMOS X-Ray 검출기를 위한 위상 고정 루프의 전하 펌프 회로)

  • Hwang, Jun-Sub;Lee, Yong-Man;Cheon, Ji-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.5
    • /
    • pp.359-369
    • /
    • 2020
  • In this paper, we proposed a charge pump (CP) circuit that has a wide operating range while reducing the current mismatch for the PLL that generates the main clock of the CMOS X-Ray detector. The operating range and current mismatch of the CP circuit are determined by the characteristics of the current source circuit for the CP circuit. The proposed CP circuit is implemented with a wide operating current mirror bias circuit to secure a wide operating range and a cascode structure with a large output resistance to reduce current mismatch. The proposed wide operating range cascode CP circuit was fabricated as a chip using a 350nm CMOS process, and current matching characteristics were measured using a source measurement unit. At this time, the power supply voltage was 3.3 V and the CP circuit current ICP = 100 ㎂. The operating range of the proposed CP circuit is △VO_Swing=2.7V, and the maximum current mismatch is 5.15 % and the maximum current deviation is 2.64 %. The proposed CP circuit has low current mismatch characteristics and can cope with a wide frequency range, so it can be applied to systems requiring various clock speed.

A Monte Carlo Study of Secondary Electron Production from Gold Nanoparticle in Kilovoltage and Megavoltage X-rays (몬테칼로 기법을 이용한 금 나노입자에서의 2차 전자 발생 평가)

  • Hwang, Chul-Hwan;Kang, Se-Sik;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.153-159
    • /
    • 2016
  • This study investigated relationship between secondary electrons produced from single gold nanoparticle as a result of its interaction with radiation and particle size and incidence energy, provided basic data related to the dose enhancement effect based on gold nanoparticles. Monte Carlo simulation was applied by using MCNPX MC code, 50, 100, 150 kV and 6, 15 MV x-ray energy was used. In a water phantom, single gold nanoparticles that are 30, 50, 70, 90, and 110 nm in diameter were placed and the tally volume was designated at every 10 nm. Difference in electrons produced from gold nanoparticles was normalized based on absence of nanoparticle. When the X ray energy decreased and the diameter of gold particles increased, more electrons were produced. When the energy was lower, in the linear formula related to nanoparticle size and electron production, the gradient was higher. And, in comparison to the MV X-ray, at kV X-ray, significantly more electrons were produced. This study can be used as data to understand the dose enhancement effect based on gold nanoparticles, and further research related to various materials that dose enhancement including gold nanoparticles needs to be conducted.

The microstructure and adhesive characteristics of Ti-Al-V-N films prepared by reactive magnetron sputtering (반응성 마그네트론 스퍼터링법으로 제조한 Ti-Al-V-N 박막의 미세조직 및 부착특성에 관한 연구)

  • Sohn, Yong-Un;Lee, Young-Ki
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.12 no.3
    • /
    • pp.199-205
    • /
    • 1999
  • The quaternary Ti-Al-V-N films have been grown on glass substrates by reactive dc and rf magnetron sputter deposition from a Ti-6Al-4V target in mixed Ar-$N_2$ discharges. The Ti-Al-V-N films were investigated by means of X-ray diffraction(XRD), electron probe microanalysis(EPMA) and scratch tester. Both XRD and EPMA results indicated that the Ti-Al-V-N films were of single B1 NaCl phase having columnar structure with the (111) preferred orientation. Scratch tester results showed that the adhesion strength of Ti-Al-V-N films which treated with substrate heating and vacuum annealing was superior to that of as-deposited film. The good adhesion strength was also achieved in the double-layer structure of Ti-Al-V-N/Ti-Al-V/Glass.

  • PDF

Microstuctures and Themal Stability of Rapidly Solidified Al-Fe-V-Si-(Mn) Alloys (급랭응고한 Al-Fe-V-Si계 합금의 미세조직과 열안정성에 관한 연구)

  • Kim, Seon-Hwa;Park, Won-Wook
    • Applied Microscopy
    • /
    • v.21 no.2
    • /
    • pp.57-66
    • /
    • 1991
  • The main purpose of this paper was to investigate the change of rapidly solidified microstructures and dispersoid behavior according to heat-treatment in the Al-Fe-V-Si-(Mn) alloys. It was found that (111) preferred orientation identified by X-ray diffraction and fine subgrain/large grain were observed in the rapidly solidified Al-Fe-V-Si-(Mn) alloys. Cell boundary of the zone A was composed of the microcrystalline, whereas that of the zone B was amorphous. Decomposition of the Al-Fe-V-Si-(Mn) alloys occurred at about $300^{\circ}C$. These alloys exhibited excellent thermal stability at the elevated temperature. Microstructure of the zone B was more stable than that of the zone A. The spherical dispersoid and 5-fold symmetry phase was also more thermally stable than the amorphous structure of cell boundary.

  • PDF

Aorto-Coronary Bypass Graft - A Case Report - (관상동맥 우회술 치험 1)

  • 이신영
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.384-392
    • /
    • 1987
  • The occlusive coronary artery disease presents a potential threat to a significant population in the United State. According to many case reports, the increasing incidence of coronary artery disease due to atherosclerosis is noted in Korean, recently. We experienced one case of coronary artery disease. He was a 68 year old male who had been suffered from hypertension since 1 5 years ago, and had intermittent conservative treatment at local clinic. He had been afflicted with severe chest pain on exertion, but this symptom was relieved on rest. Pre-operative EKG finding revealed no any other ischemic sign. Significant S-T segment depression was noted at lead II, aVF, V3, V4, and V5, and inverted T wave in V5 and V6 after Master`s test. Simple chest X-ray finding showed emphysematous field, bilaterally. Final pre-operative diagnosis was made by coronary angiogram, which showed almost 90% degree of occlusive lesion in the proximal part of left main coronary artery above the origin LAD artery. He was treated successfully by aorta-coronary saphenous vein graft under extra-corporeal circulation in May, 1987. He has been followed up with uneventful course.

  • PDF