• 제목/요약/키워드: utility-connected

검색결과 198건 처리시간 0.025초

High-Frequency Flyback Transformer Linked PWM Power Conditioner with An Active Switched Capacitor Snubber

  • Mun, Sang-Pil;Kim, Soo-Wook;Joo, Seok-Min;Park, Young-Jun
    • 조명전기설비학회논문지
    • /
    • 제22권7호
    • /
    • pp.7-15
    • /
    • 2008
  • A single active capacitor snubber-assisted soft-switching sinewave pulse modulation utility-interactive power conditioner with a three-winding flyback high frequency transformer link and a bidirectional active power switch in its secondary side has been proposed. With the aid of the switched-capacitor quasi-resonant snubber cell, the high frequency switching devices in the primary side of the proposed DC-to-AC sinewave power inverter can be turned-off with ZVS commutation. In addition to this, the proposed power conditioner in the DCM can effectively take the advantages of ZCS turn-on commutation. Its output port is connected directly to the utility AC power source grid. At the end, the prototype of the proposed HF-UPC is built and tested in experiment. Its power conversion conditioning and processing circuit with a high frequency flyback transformer link is verified and the output sinewave current is qualified in accordance with the power quality guidelines of the utility AC interactive power systems.

Utility-Connected Solar Power Conditioner Using Edge-Resonant Soft Switching Duty Cycle Sinewave Modulated Inverter Link

  • Ogura, Koki;Chandhaket, Srawouth;Nakaoka, Mutsuo;Terai, Haruo;Sumiyoshi, Shinichiro;Kitaizumi, Takeshi;Omori, Hideki
    • Journal of Power Electronics
    • /
    • 제2권3호
    • /
    • pp.181-188
    • /
    • 2002
  • The utility interfaced sinewave modulation Inverter for the solar photovoltaic power conditioner with a high frequency transformer is presented for residential applications. As compared with the conventional full-bridge hard switching slnewave PWM inverter with a high frequency link, the simplest single-ended edge-resonant soft switching sinewave inverter with a sinewave duty cycle pulse control scheme is implemented, resulting in size and weight reduction, low cost and high efficiency This paper presents a prototype system of the sinewave zero voltage soft switching sinewave inverter for solar power conditioner, along with its operating principle and unique features. In addition to these, this paper discusses a control implementation to deliver high quality output current. Major design of each component and the power loss analysis under actual power processing is also discussed and evaluated from an experimental point of view A newly developed utility-connected sinewave power conditioning circuit which achieves 92.5% efficiency under 4kW output is demonstrated.

계통연계형 인버터의 LCL필터 최적 설계기법 (Optimized LCL filter Design Method of Utility Interactive Inverter)

  • 정상혁;최세완
    • 전력전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.103-109
    • /
    • 2013
  • The conventional LCL filter design method of the utility interactive inverter considers only harmonics attenuation of the current injected to the grid. However, in case of utility-interactive inverter with critical load the voltage quality of the critical load should also be considered for LCL filter design. Also, considering cost and volume of LCL filters. it is important to have minimum values of inductance and capacitance as far as the harmonic standards are satisfied. In this paper a LCL filter design method is proposed to satisfy not only the harmonic standards of the grid current during the grid-connected mode but the voltage quality of the critical load during grid-connected mode and stand-alone mode. With the proposed method optimized values of LCL filters could be obtained by applying weighting factor to voltage ripple across the critical load, inductor volume, amount of reactive current and system bandwidth.

행원풍력단지와 연계된 성산변전소 모선의 전기품질 분석 (Power Quality Analysis of Sungsan Substation Bus Connected to Hangwon Wind Farm)

  • 안재현;고성민;나경윤;김세호;김호찬;김영환;최병천
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.146-148
    • /
    • 2005
  • The number of wind generation installations are growing substantially in Jeju, Korea. Many of these installations are significant in size and directly connected to the distribution system. In these distributed applications, it is not uncommon for the turbines to be connected near the end of a long rural distribution feeder from which end-users are served. Therefore, utility grid interconnection standards for interconnecting non-utility distributed generation systems are essential to both power system company and generation company. In this paper, it is investigated the power quality of Sungsan substation bus connected to Hangwon wind power generation farm.

  • PDF

Remote Monitoring of Abrupt Overflowing in Common Utility Duct Using Reflective Side-Polished Optical Fiber Submersion Sensor

  • Lee, Cherl-Hee;Kim, Cheol;Kang, Shin-Won;Song, Jae-Won
    • Journal of the Optical Society of Korea
    • /
    • 제12권3호
    • /
    • pp.166-169
    • /
    • 2008
  • The submersion monitoring system based on a reflective side-polished optical fiber submersion sensor with an optical fiber mirror was shown to be an effective alarm system with remote monitoringwhen the drainage capacity of a common utility duct is exceeded due to heavy rainfall. The proposed sensor was connected to an existing installed optical fiber network at a height of 250mm in a common utility duct, and then tested under sample materials(distilled water, river water, sea water, foul water, muddy water, petroleum, edible oil) at a distance of 1km from the sensor for remote sensing. In experiments, the proposed real-time sensor system reduced maintenance cost and improved monitoring efficiency by using a reflection-type side-polished optical fiber submersion sensor efficient for remote monitoring of a common utility duct.

Reduction of Input Current Harmonics for Three Phase PWM Converter Systems under a Distorted Utility Voltage

  • Park, Nae-Chun;Mok, Hyung-Soo;Kim, Sang-Hoon
    • Journal of Power Electronics
    • /
    • 제10권4호
    • /
    • pp.428-433
    • /
    • 2010
  • This paper proposes a harmonics reduction technique for the input currents of three phase PWM converters. The quality of the phase angle information on the utility voltage connected to the PWM converters affects their control performance. Under a distorted utility voltage, the extracted phase angle based on the synchronous reference frame PLL method is distorted. This causes large harmonics in the input currents of a PWM converter. In this paper, a harmonics reduction method that makes the input currents in the PWM converter sinusoidal even under distorted utility conditions is proposed. By the proposed method, without additional hardware, the THD (Total Harmonic Distortion) of the input currents can be readily limited to below 5% which is the harmonic current requirements of IEEE std. 519. Its validity is verified by simulations and experimental results.

How do multilevel privacy controls affect utility-privacy trade-offs when used in mobile applications?

  • Kim, Seung-Hyun;Ko, In-Young
    • ETRI Journal
    • /
    • 제40권6호
    • /
    • pp.813-823
    • /
    • 2018
  • In existing mobile computing environments, users need to choose between their privacy and the services that they can receive from an application. However, existing mobile platforms do not allow users to perform such trade-offs in a fine-grained manner. In this study, we investigate whether users can effectively make utility-privacy trade-offs when they are provided with a multilevel privacy control method that allows them to recognize the different quality of service that they will receive from an application by limiting the disclosure of their private information in multiple levels. We designed a research model to observe users' utility-privacy trade-offs in accordance with the privacy control methods and other factors such as the trustworthiness of an application, quality level of private information, and users' privacy preferences. We conducted a user survey with 516 participants and found that, compared with the existing binary privacy controls, both the service utility and the privacy protection levels were significantly increased when the users used the multilevel privacy control method.

고도 정보 연계 사회의 구축을 위한 SPB(Seamlessness-Privacy-Benefit) 패러다임 (SPB(Seamlessness-Privacy-Benefit) Paradigm for Construction of Highly-Connected Information Society)

  • 이경전;전정호
    • 한국IT서비스학회지
    • /
    • 제11권2호
    • /
    • pp.131-146
    • /
    • 2012
  • The purpose of this research is two-fold : (1) we propose the paradigm to construct a connected information society according to a judgment where a coming information society will evolve into highly-connected information society having "seamlessness" as a keyword, and (2) we draw guidelines to construct infrastructures and establish systems and business models of highly-connected information society based on suggested paradigm. To achieve this, this research conducts the followings. First, we suggest reasons why a coming information society can be appropriate to be considered as highly-connected information society by examining two perspectives on the coming information society. Second, we explain the definition and characteristics of highly-connected information society and propose the SPB paradigm. Third, we analyze the utility of SPB paradigm by evaluating practices. Finally, we suggest four strategies to construct highly-connected information society based on advanced research findings and future research directions.

PV용 계통연계형 인버터의 새로운 Topology 고찰 (Inquiry of New Topology for Grid-connected Photovoltaic Inverter)

  • 정영석;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.248-251
    • /
    • 1999
  • Recently, according to developing industry and life style, power consumption have been increased year after year. Currently these much power demand from power consumer is weakening the allowable power reverse margin in summer. As on of the remedies about this problem, the small scale grid-connected photovoltaic system is considered for auxiliary power source. Generally, grid-connected inverter have a isolation transformer for electrical isolation from utility. This paper propose transformerless system topology an inquiry the validity using simulation.

  • PDF

직렬접속형 다이오드 정류기 시스템의 전류주입에 의한 고조파 저감 (Drawing Sinusoidal Input Currents of Series-Connected Diode Rectifiers by A Current Injection Technique)

  • 최세완;오준용;원충연;김영석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.346-349
    • /
    • 1999
  • This paper proposes a new series-connected diode rectifier which draws sinusoidal input currents. The proposed rectifier system is configured by adding an auxiliary circuit to the conventional 12-pulse series-connected diode rectifier and employing a current injection technique. A low kVA (0.02Po (PU) ) active current source injects a triangular current results in near sinusoidal input current from the utility with less than 1% THD. The resulting system is suitable for high voltage and high power applications. Experimental results is provided from a 220VA rectifier system.

  • PDF