Analysis of the Switch Installation Criteria by Increasing Operating Capacity in Distribution Line (배전선로 운전용량 상향에 따른 개폐기 설치 기준 분석)

  • Jo, Nam-Hun;Ha, Bok-Nam;Lee, Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.6
    • /
    • pp.290-295
    • /
    • 2002
  • The present assignment in installing the number of switches for distribution line was made on the basis of a normal feeder capacity 7,000kVA in KEPCO(Korea Electric Power Corporation), Korea. But the normal capacity is revised to 10000kVA in 1998. Even increasing limit of the operating capacity of the distribution lines enables us to give some benefit for the operation flexibility and investment cost of the distribution system. It is disadvantageous in the viewpoint of supply reliability. In distribution systems, switches are equipped to improve the reliability of distribution systems by minimizing the outage section due to fault and maintenance. Utility generally improves the reliability by minimizing the length of outage section, which is caused by fault and maintenance, through switch equipment on distribution system. In order to cope with the changes such as operation capacity, it is necessary to study whether the present criteria is reasonable or not, also to confirm whether the present criteria of installing switches in line is improved or not. In this study, we proposes the number of switch per feeder on the basis of present operation capacity in distribution system.

A Study on the Protection Wire Type Decision of Catenary System in the 350km/h High Speed Line (350km/h급 고속전차선로 보호선의 선종결정 기법에 관한 연구)

  • Lee, Hack-Pyo;Seo, Ki-Bum;Park, Jae-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1818-1823
    • /
    • 2015
  • In this paper, we analyzed the optimal configuration of protection wire that have been installed in the electric railway power supply system. Protection wires are to suppress the ground potential rise when the short circuit fault between contact wire-rail(C-F), and protect the electronics equipments(signalling and communication) that are facility the wayside. The role of protection wires must be feed back quickly the fault current to the substation when a short circuit fault occurs. In this paper, we proposed that only one line to install the protection wire. Comparing how to newly proposed and existing system, most of the performance is similar. The reason is that most of the current flowing in the protection wire near the location where the fault occurred. There is no problem even if in one line for human safe and the low impedance of the return circuit in dimension to ensure the safety of the facility during the fault. To ensure safety during an fault occurs, it is sufficient even by one line. But, In the protection wire of facilities planning it is necessary to design taking into account the potential utility.

LOAD SHEDDING SIMULATION FOR MAINTAINING FREQUENCY STABILITY-GAS SEPARATION PLANT CASE (주파수 안정도 유지를 위한 부하차단 시뮬레이션-가스분리플랜트 사례)

  • Kim, Bong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.72_73
    • /
    • 2009
  • The industrial power system has the radial plant distribution system and domestic generators to supply the essential loads. When the system is isolated from the utility tie line, the system frequency drops resulting in the trip of generators. The load shedding scheme shall be properly designed to secure the essential load. In this paper two kinds of load shedding schemes, those are, the Fast Act Load Shedding(FALS) and Under Frequency Load Shedding(UFLS) are simulated and compared taking an example of petrochemical gas separation plant.

  • PDF

반도체 제조라인의 냉수 시스템 효율성 증대에 관한 연구

  • 김기운;김광선;곽승기;박만호
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2004.05a
    • /
    • pp.253-258
    • /
    • 2004
  • 21C 정보화시대를 맞이하여 반도체 산업이 급속하게 발전함에 따라 컴퓨터를 활용한 효율성이 높은 유틸리티 관리 시스템(New Utility Management System) 기술이 중요시되는 추세이다. 본 연구에서는 유틸리티 관리시스템의 한 부분인 냉수 시스템에 대해 정상상태 유동해석을 통하여 각 구성 요소에서의 유량 및 압력, 온도를 제공할 수 있는 컴퓨터해석시스템을 구현하였다. 효율성 증대를 위해 펌프 위치에 따른 시스템 변화를 파악하여 시스템에 영향을 크게 미칠 수 있는 펌프 즉, 가동하면 효율적인 펌프를 결정하였으며 최적의 리턴라인(Return Line) 위치를 설계하였다. 이 결과는 운전 및 관리의 효율성 증대와 에너지 절감을 위하여 매우 유익한 활용이 가능하다.

  • PDF

Mixed-Model Sequencing Using Genetic Algorithms with Multiple Evaluation Criteria (다목적 유전 알고리듬을 이용한 혼합모델 조립라인의 최적 생산순서계획)

  • Kim, Yearn-Min;Kim, Young-Jin
    • IE interfaces
    • /
    • v.13 no.2
    • /
    • pp.204-210
    • /
    • 2000
  • This paper deals with the problem of mixed-model sequencing on an assembly line. In this sequencing problem we want to minimize the risk of the conveyor stoppage and the total utility work. This paper applies genetic algorithm to solve the mixed-model sequencing problem which is formulated as an integer programming. The solution we get from this algorithm is compared with the solution of Tsai(1995)'s.

  • PDF

Measurement of Channel Impedance Characteristics for Indoor Power Line Communications (옥내 전력선 통신 채널 임피던스 특성 측정)

  • Heo Yoon-Seok;Kim Chul;Hong Bong-Hwa;Lee Dae-Young;Jun Kye-Suk
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.11
    • /
    • pp.79-86
    • /
    • 2005
  • This paper describe a method for measuring line impedance as a function of frequency for an energized powerline in normal operation. A small sinusoidal signal of a powerline communication utility frequency $30khz\~1Mhz$ band is continuously injected into the line, and a implemented impedance analyzer calculates the indoor powerline channel impedance from the measured magnitude and phase of resulting voltage and current. The impedance measurement is executed over a range of frequencies to produce a wideband impedance versus frequency characteristic. Implemented impedance analyzer can analysis powerline communication environments measuring line impedance due to load caused in indoor. And measured analysis information through the database can use to evaluate performance of modem and to decide test environment standard.

Voltage and Transient State Analysis of Distribution Line connected to Wind Power Generation (풍력발전이 연계된 배전선로 전압 및 과도상태 해석)

  • Kim, Se-Ho;Na, Kyoung-Yoon;Kim, Gun-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.2
    • /
    • pp.61-67
    • /
    • 2006
  • The use of the wind energy resource is a rapidly growing area world-wide. The number of installed units is continuously increasing, and therefore, it is important to respect and to deal with the impact of wind power generation system. From the view of an electric grid utility, there is a major problem with the impact of the wind system on the voltage of the electric grid, to which a turbine is connected. In this paper, it is investigated the voltage impact and transient state analysis on distribution line, with which wind power generation system is connected. Connections of wind power system usually occur to voltage drop due to reactive power absorption and sometime result in higher than nominal voltage.

Stator Flux Vector Control Of Induction Motor using Parameter Estimation (파라메터 추정을 통한 유도전동기의 고정자 자속 기준 벡터 제어)

  • Hahm, Nyun-Kun;Jun, Kee-Young;Kim, Sung-Nam;Lee, Seung-Hwan;Lee, Hoon-Goo;Han, Kyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2123-2125
    • /
    • 1997
  • In the induction motor control, the rotator flux estimation methods are used in the implement vector control of the induction motor instead of the potentical-meter or tacho-meter, a system is very sensitive in noise. In this paper, the parameters that do not affect the stablity of the system were applied in Off-Line tuning methods. In case of the rotator resistor that is sensitive. On-Line tuning methods applied in the steady state. We ascertained that the utility of a theory applied in stator flux orientation vector control through the simulation.

  • PDF

An Interactive Multi-objective Decision Making Technique for Sequencing Mixed Model Assembly Lines Based on Evolution Programs (진화프로그램에 기반을 둔 혼합모델 조립라인의 투입순서를 위한 대화형 다목적 의사결정 기법)

  • Kim, Yeo-Keun;Lee, Soo-Yeon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.25 no.3
    • /
    • pp.310-320
    • /
    • 1999
  • A mixed model assembly line (MMAL) is a special type of production line where a variety of product models similar in product characteristics are assembled. Determining the model sequence is an important problem for the efficient use of MMALs. This paper considers interactive multiobjective decision making problems for MMAL sequencing. Evolution program is employed as an underlying framework. In this study, a way of approximating the linear utility function is first studied. To improve its search efficiency to the solution space preferred by a decision maker, some modifications of a standard evolution program are made: operating several subpopulations instead of a single population and merging two or more subpopulations to a single subpopulation, and using a Pareto pool. Extensive computational experiments are carried out to verify the performance of the proposed approach. The computational results show that our approach is promising in solution quality.

  • PDF

Study on the Development of Condition Monitoring Technology for Turbine Lubricating Systems in Power Plants (발전용 터빈 윤활계통 기계시스템의 상태진단기술 개발연구)

  • 신규식;김재평;남창현;백수곤;권오관;안효석;윤의성;손동구
    • Tribology and Lubricants
    • /
    • v.10 no.4
    • /
    • pp.51-58
    • /
    • 1994
  • Condition monitoring technology has recently been received much attention in the light of its significance on the maintenance of complex machineries such as turbines in power plants. Currently, turbines in power plants are maintained by scheduled overhaul based on the manufacturer's recommendations and the utility's experience. Although this preventive maintenance is known to be very effective, operators have less access to identify failure of elements when it happens between overhaul period. Therefore, in this study, a development of a on-line condition monitoring system through wear debris analysis of lubricating oils is aimed with a view to detecting abnormal wear behaviour of bearings and other wet-components at an early stage, allowing better outage scheduling and minimizing forced outages. For field application purposes, the on-line system developed was installed on the turbine of the No.4 unit at Ulsan Power Plant and its performance has been evaluated on site.