• Title/Summary/Keyword: utility damage

Search Result 125, Processing Time 0.023 seconds

Antioxidative and Probiotic Properties of Lactobacillus gasseri NLRI-312 Isolated from Korean Infant Feces

  • Kim, H.S.;Jeong, S.G.;Ham, J.S.;Chae, H.S.;Lee, J.M.;Ahn, C.N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.9
    • /
    • pp.1335-1341
    • /
    • 2006
  • We selected a Lactobacillus spp. from Korean healthy infant feces based upon their antioxidant activity. This strain was identified as Lactobacillus gasseri by 16S rDNA sequencing, and named Lactobacillus gasseri NLRI-312. In the present study, we investigate the protective effect of this strain on the $H_2O_2$ induced damage to cellular membrane lipid and DNA in Jurkat cells. To estimate the extent of cellular lipid peroxidation inhibition, MDA (malondialdehyde) was measured, and DNA damage was tested by the comet assay. We also examined probiotic properties including tolerance to acid and bile, antibiotic resistance. From the results obtained, the supplementation of Jurkat cells with NLRI-312 decreased in DNA damage, while no effect was shown on MDA decrease. In probiotic properties, this strain was resistance to both acid and bile, showed considerably higher survival when incubated in pH 2 or 1% bile salts (w/v). We concluded that the NLRI-312 could be used as potential probiotic bacteria, with the effect of reducing DNA damage induced by $H_2O_2$.

Deep Excavation-induced Building and Utility Damage Assessment (도심지 깊은굴착시 주변 건물 및 매설관 손상평가)

  • 유충식
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.85-95
    • /
    • 2002
  • A substantial portion of the cost of deep excavations in urban environments is devoted to prevent ground movements and their effects on adjacent buildings and utilites. Prediction of ground movements and assessment of the risk of damage to adjacent structures has become an essential part of the planning, design, and construction of a deep excavation project in the urban environments. This paper presents damage assessment techniques for buildings and utilities adjacent deep excavation, which can be readily used in practice.

  • PDF

Response to Clothing Utility-Reduction according to Clothing-Wearing Motives (의복 착용 동기에 따른 의복 효용 감소에 대한 방응)

  • 정인희;박상진;권영일
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.7
    • /
    • pp.1332-1340
    • /
    • 2001
  • This study was designed (1) to examine the results of previous qualitative research on clothing-wearing motives by quantitative approach, (2) to explore the concept of clothing utility, utility-reduction and discard, and (3) to investigate the impact of clothing-wearing motives on consumer attitudes and consuming-behaviors. Date were collected by questionnaire from 443 collegiate students between August and September of 2000, and 396 questionnaires were analyzed. 3 groups were identified on the basis of clothing-wearing motives and named by extroversion group, introversion group, and least clothing-congnizing group respectively. This supported the qualitative results in part, especially in the direction of motives. Clothing utility-reduction factors were identified as appearance demage, social-psychological damage, and abandonment-causing damage. The 3 groups were responded on utility-reduction differently, thus clothing-wearing motive variable was determined as useful in fashion marketing.

  • PDF

Seismic Fragility of Underground Utility Tunnels (지하 공동구 시설물의 지진취약도 분석)

  • Lee, Deuk-Bok;Lee, Chang-Soo;Shin, Dea-Sub
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.5
    • /
    • pp.413-419
    • /
    • 2016
  • Damage of infrastructures by an earthquake causes the secondary damage through the world at large more than the damage of the structures themselves. Amomg them, underground utility tunnel structures comes under the special life line: communication, gas, electricity and etc. and it has a need to evaluate its fragility to an earthquake exactly. Therefore, the destruction ability according to peak ground acceleration of earthquakes for the underground utility tunnels is evaluated in this paper. As an input ground motion for evaluating seismic fragilities, real earthquakes and artificial seismic waves which could be generated in the Korean peninsula are used. And as a seismic analysis method, response displacement method and time history analyzing method are used. An limit state which determines whether destruction is based on the bending moment and shear deformation. A method used to deduct seismic fragility curve is method of maximum likelihood and the distribution function is assumed to the log normal distribution. It could evaluate the damage of underground utility tunnels to an earthquake and could be applied as basic data for seismic design of underground utility tunnel structures.

Islanding Detection for PV System Connected to a Utility Grid

  • Han, Seok-Woo;Mok, Hyung-Soo;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.719-723
    • /
    • 1998
  • Prevention of the islanding phenomena is one of the most important issues because it can damage electrical equipment connected to the utility system and endanger human life. It is very difficult to detect an islanding condition of a power distribution line with conventional voltage of frequency relays, while the output power and the load power of utility interactive PV inverter units are in nearly balanced state in both active power and reactive power. This paper describes the protective equipment that prevents the PV system connected to the utility grid from starting islanding. Both predictive ocntrol method and harmonic injection method are used for a current control and islanding detection for operating safety.

  • PDF

Water Allocation by Estimation of Damage Function in a Water-Deficit Situation (피해함수 산정을 통한 물 부족 상황에서의 용수배분 방안)

  • Yi, Choong-Sung;Park, Kyo;Choi, Seung-An;Shim, Myung-Pil
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.5 s.166
    • /
    • pp.431-440
    • /
    • 2006
  • Recently, water conflicts are rapidly increasing and more serious. So, it needs to establish the reasonable water allocation rules and criteria. This study aims at performing inter-sectoral water allocation with a focus on economic effciency and social utility. To allocate water among the sectoral water uses, water shortage damage functions were estimated and then converged to the utility functions. Finally, each sectoral water uses are allocated by applying 'law equimarginal utility' to maximize social utility. Also weighting factor which reflects scale and characteristic of water demand in a region was estimated to perform the inter-regional water allocation. The water allocation rule was applied to the future water-deficit situation in Han-river basin. As a result, domestic water use was allocated more sufficient agricultural and industrial water use. Also, the water shortage occurs severely in the rural area like Gangwon-do because of its low urbanization and industrialization. This study suggests a alternative view of the economic water allocation which have difficulty under water supply mechanism in Korea.

Damage Detection in Beam Structures using Harmony Search Method and Frequency Response (보 구조물의 주파수응답을 이용한 화음탐색법 기반 손상검색)

  • Lee, So-Young;Park, Jae-Hyung;Yi, Jin-Hak;Ryu, Yeon-Sun;Kim, Jeong-Tae
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.139-144
    • /
    • 2008
  • In this study, damage detection method using harmony search method and frequency response is proposed. In order to verify this method, the following approaches are implemented. Firstly, damage detection method using harmony search is developed. To detect damage, objective function that minimize difference with natural frequency and modal strain energy from undamaged and damaged model is used. Secondly, finite element model for beam structure is created. And damage scenario is determined. Lastly, damage detection is performed by proposed method and utility of proposed method is verified.

  • PDF

Theoretical formulation of double scalar damage variables

  • Xue, Xinhua;Zhang, Wohua
    • Computers and Concrete
    • /
    • v.19 no.5
    • /
    • pp.501-507
    • /
    • 2017
  • The predictive utility of a damage model depends heavily on its particular choice of a damage variable, which serves as a macroscopic approximation in describing the underlying micromechanical processes of microdefects. In the case of spatially perfectly randomly distributed microcracks or microvoids in all directions, isotropic damage model is an appropriate choice, and scalar damage variables were widely used for isotropic or one-dimensional phenomenological damage models. The simplicity of a scalar damage representation is indeed very attractive. However, a scalar damage model is of somewhat limited use in practice. In order to entirely characterize the isotropic damage behaviors of damaged materials in multidimensional space, a system theory of isotropic double scalar damage variables, including the expressions of specific damage energy release rate, the coupled constitutive equations corresponding to damage, the conditions of admissibility for two scalar damage effective tensors within the framework of the thermodynamics of irreversible processes, was provided and analyzed in this study. Compared with the former studies, the theoretical formulations of double scalar damage variables in this study are given in the form of matrix, which has many features such as simpleness, directness, convenience and programmable characteristics. It is worth mentioning that the above-mentioned theoretical formulations are only logically reasonable. Owing to the limitations of time, conditions, funds, etc. they should be subject to multifaceted experiments before their innovative significance can be fully verified. The current level of research can be regarded as an exploratory attempt in this field.

An Application of the Water Mist System for Underground Utility Tunnel (지하구 미분무수 소화설비 적용에 관한 연구)

  • 김운형;김종훈;박승민;김태수;민인홍;전동일;김상욱
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.66-76
    • /
    • 2002
  • This paper includes new nozzle design, basic design factors of water mist system that minimize a thermal damage of cable causing business interruption and applying underground utility tunnel. A underground concrete structure (2.5 m(H)$\times$2.5 m(W)$\times$25 m(D)) is constructed in order to test a nozzle performance. Under the designing fire scenario, critical thermal damage of cable sheath ($400^{\circ}c$) reached within a 2 minutes with unsuppressed fire, but type 1 nozzle (SMD 470 $\mu{m}$) and type 2 nozzle (SMD 650 $\mu{m}$) control cable temperature below $400^{\circ}c$. A system performance and fundamental design factors; K factor, flow rate, spray angle, size distribution, nozzle pressure, spray density are analyzed and proposed for system optimization.

Implementation of condition monitoring system in underground utility tunnels using inductive coupler (유도성 커플러를 이용한 지하공동구의 상태감시시스템)

  • Ju, Woo-Jin;Kim, Hyun-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.8
    • /
    • pp.1597-1603
    • /
    • 2017
  • The incidence of fire in underground utility tunnel is lower than other fires, but the damage caused by fire can cause social loss due to social management paralysis as well as economic loss. Hereupon, this paper presents the results of an empirical test on the construction of the underground utility tunnel condition monitoring system using the leakage coaxial cable installed in the underground utility tunnel. For this reason, a verification test was conducted by connecting a inductive coupler 200 Mbps power line communication modem with insertion loss characteristics of $-6{\pm}2dB$ to the installed the leakage coaxial cable installed in the underground utility tunnel. As a result, We confirmed sending/receiving of IP cameras up to 500 m. Therefore, it is judged that it is possible to construct a condition monitoring system for underground utility tunnel by using the leakage coaxial cables installed in the underground utility tunnels without installing additional communication lines for data transmission.