• 제목/요약/키워드: upper limit

검색결과 894건 처리시간 0.021초

주거 및 사무환경 챔버에서의 생활소음에 대한 감성적 평가 (Perceptual Evaluation of Noise Sources in a Chamber for Residential and Working Environment)

  • 전진용;김경호;정정호;류종관;조문재
    • 한국소음진동공학회논문집
    • /
    • 제12권6호
    • /
    • pp.437-444
    • /
    • 2002
  • This paper is to provide the basic way of a acoustical evaluation and efficient control noise by investigating the limits of perceptual loudness of living environment and by finding out any correlation between Physical characteristics of noise and psychoacoustic parameters. The limits of perceptual loudness were selected by the subjects in a chamber for residential and working environment. And the noise sources were analyzed to find out whether there is any correlation with Zwicker parameters and ACF factors. In this study especially, to set up the domestic evaluation grade about floor impact noise. we'd like to suggest the loudness Perception research result as fundamental resource for setting up the evaluation grade through the result that is based on annoyance. In the result of this research, upper limit of heavy-weight impact noise was L-60, and lower limit of it was L-50. On the other hand, upper limit of light-weight impact noise was L-70, and lower limit of it was L-55. It seemed that the loudness of noise from vacuum cleaner noise does not affect its perceived noisiness. Noises implicated In human such as floor walking noise and talking sound, are the most irritating noise in office environment.

노말테트라데칸의 연소특성치 측정에 의한 위험성 평가 (The Evaluation of Hazard by Measurement of Combustible Characteristics of n-Tetradecane)

  • 하동명
    • 한국안전학회지
    • /
    • 제27권5호
    • /
    • pp.70-76
    • /
    • 2012
  • For the safe handling of n-tetradecane, the lower flash points and the upper flash point, fire point, AITs (auto-ignition temperatures) by ignition delay time were experimented. Also lower and upper explosion limits by using measured the lower and upper flash points for n-tetradecane were calculated. The lower flash points of n-tetradecane by using closed-cup tester were measured $104^{\circ}C$ and $112^{\circ}C$. The lower flash points and fire point of n-tetradecane by using open cup tester were measured $113^{\circ}C$ and $115^{\circ}C$, respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-tetradecane. The experimental AIT of n-tridecane was $207^{\circ}C$. The calculated lower and upper explosion limit by using measured lower $104^{\circ}C$ and upper flash point $140^{\circ}C$ for n-tetradecane were 0.63 Vol.% and 3.18 Vol%.

노말펜타데칸의 화재 및 폭발 특성치의 측정 (The Measurement of Fire and Explosion Properties of n-Pentadecane)

  • 하동명
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.53-57
    • /
    • 2013
  • For the safe handling of n-pentadecane, the lower flash points and the upper flash point, fire point, AITs(auto-ignition temperatures) by ignition delay time were experimented. Also lower and upper explosion limits by using measured the lower and upper flash points for n-pentadecane were calculated. The lower flash points of n-pentadecane by using closed-cup tester were measured $118^{\circ}C$ and $122^{\circ}C$. The lower flash points and fire point of n-pentadecane by using open cup tester were measured $126^{\circ}C$ and $127^{\circ}C$, respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-pentadecane. The experimental AIT of n-pentadecane was $195^{\circ}C$. The calculated lower and upper explosion limit by using measured lower $118^{\circ}C$ and upper flash point $174^{\circ}C$ for n-pentadecane were 0.54 Vol.% and 6.40 Vol.%.

노말헥사데칸의 화재 및 폭발 특성치의 측정 (The Measurement of Fire and Explosion Properties of n-Hexadecane)

  • 하동명
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.39-45
    • /
    • 2014
  • For the safe handling of n-hexadecane, the lower flash points and the upper flash point, fire point, AITs(auto-ignition temperatures) by ignition delay time were experimented. Also lower and upper explosion limits by using measured the lower and upper flash points for n-hexadecane were calculated. The lower flash points of n-hexadecane by using the Setaflash and the Pensky-Martens closed testers were measured $128^{\circ}C$ and $126^{\circ}C$, respectively. The lower flash points of the Tag and the Cleveland open cup testers were measured $136^{\circ}C$ and $132^{\circ}C$, respectively. The fire points of the Tag and the Cleveland open cup testers were measured $144^{\circ}C$. respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-hexadecane. The experimental AIT of n-hexadecane was $200^{\circ}C$. The calculated lower and upper explosion limit by using measured lower $128^{\circ}C$ and upper flash point $180^{\circ}C$ for n-hexadecane were 0.42 Vol.% and 4.70 Vol.%.

Scaled SONOSFET를 이용한 NAND형 Flash EEPROM (The NAND Type Flash EEPROM Using the Scaled SONOSFET)

  • 김주연;권준오;김병철;서광열
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.145-150
    • /
    • 1998
  • 8$\times$8 bit scaled SONOSFET NAND type flash EEPROM that shows better characteristics on cell density and endurance than NOR type have been designed and its electrical characteristics are verified with computer aided simulation. For the simulation, the spice model parameter was extracted from the sealed down SONOSFET that was fabricated by $1.5mutextrm{m}$ topological design rule. To improve the endurance of the device, the EEPROM design to have modified Fowler-Nordheim tunneling through the whole channel area in Write/Erase operation. As a result, it operates Write/Erase operation at low current, and has been proven Its good endurance. The NAND type flash EEPROM, which has upper limit of V$_{th}$, has the upper limit of V$_{th}$ as 4.5V. It is better than that of floating gate as 4V. And a EEPROM using the SONOSFET without scaling (65$\AA$-l65$\AA$-35$\AA$), was also designed and its characteristics have been compared. It has more possibliity of error from the V$_{th}$ upper limit as 4V, and takes more time for Read operation due to low current. As a consequence, it is proven that scaled down SONOSFET is more pertinent than existing floating gate or SONOSFET without scaling for the NAND type flash EEPROM.EPROM.

  • PDF

편심하중을 받는 줄기초의 지지력 산정에 관한 연구 (A Study on Determination of Bearing Capacity of Eccentrically Loaded Strip Footing)

  • 권오균;정층기;김태수;김명모
    • 대한토목학회논문집
    • /
    • 제13권5호
    • /
    • pp.245-254
    • /
    • 1993
  • 본 연구에서는 탄소봉을 이장한 모형실험, 극한해석 상계법, 그리고 극한평형법을 이용한 Meyerhof 방법을 통하여 편심량이 줄기초에 미치는 영향을 연구하였다. 극한해석 상계법에 적용된 파괴메카니즘은 모형실험에서 구하여 사용하였다. 세가지 방법에 의한 결과들을 분석한 결과, 모형실험과 극한해석 상계법에 의한 결과는 편심량에 상관없이 잘 일치하지만, Meyerhof 방법은 지지력을 보수적으로 평가하고, 편심량의 증가에 따른 지지력의 감소효과도 과소평가한다. 아울러 기초너비, 근입깊이, 바닥면의 마찰 등을 변화시켜 각 요소들이 지지력에 미치는 효과를 연구하였다.

  • PDF

수질오염총량관리를 위한 환경기초시설 배출수질의 통계적 평가방법 개선 : 선형보간법의 백분위수방법 (Implementation of the Calculation Method for 95% Upper Limit of Effluent Water Quality of Sewage Treatment Plant for Total Maximum Daily Loads : Percentile Ranking Method)

  • 박재홍;김동우;오승영;류덕희;정동일
    • 한국물환경학회지
    • /
    • 제24권6호
    • /
    • pp.676-681
    • /
    • 2008
  • The evaluation of the effluent water quality of sewage treatment plant is one of the most important factor in calculating total maximum daily loads (TMDLs). Current method to calculate 95% upper limit of effluent water quality of sewage treatment plant assuming normal distribution of data needs to be implemented in case of non-normal distribution. We have investigated the applicability of percentile ranking method as a non-parametric statistical analysis in case of non-normal distribution of data.

Degassing 조건이 Ni-Cr 합금의 도재결합력에 미치는 영향 (EFFECT OF DEGASSING CONDITION ON CERAMIC BOND STRENGTH OF Ni-Cr ALLOYS)

  • 이은화;전영찬;정창모;임장섭
    • 대한치과보철학회지
    • /
    • 제38권4호
    • /
    • pp.461-471
    • /
    • 2000
  • This study evaluated the effect of degassing on the ceramic bond strength of two Ni-Cr alloys under varying holding time at the upper limit temperature and atmospheric conditions. Metal specimens were divided into 5 groups for each alloy according to degassing conditions prior to porcelain application no degassing, degassing under vacuum without hold, degassing under vacuum with hold for 5 min. and 10 min. respectively at the upper limit temperature and degassing in air. Total number of metal ceramic specimens was eighty and each group had eight specimens. The ceramic bond strength was measured by four-point flexural test using Instron and the fractured surface was examined under SEM. The results obtained were as follows. 1. Degassing in air improved the ceramic bond strength of Ni-Cr alloys. 2. In degassing under vacuum, hold at the upper limit temperature was advantageous to the ceramic bonding of Ni-Cr alloys. 3. After ceramic metal bond test, metal surfaces were partially covered with the thin porcelain layer, and the cohesive failures in porcelain were predominant in groups showing higher ceramic bond strength.

  • PDF

Performance limit of digital vibrometer using self-mixing type LDV

  • Shinohara, Shigenobu;Hara, Katsuhiko;Toyoshima, Morio;Ikeda, Hiroaki;Yoshida, Hirofumi;Sumi, Masao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.170-173
    • /
    • 1995
  • Recently, we proposed a compact digital vibrometer using a self-mixing laser Doppler velocimeter (SM-LDV). In this paper, we theoretically obtained formulas giving lower and upper limit of measurable velocity. In the prototype digital vibrometer, the theoretical value was 6.7mm/s and 162.8mm/s, respectively, which agreed well with the measured value. The upper limit of measurable displacement amplitude was 12OO.mu.m at 10Hz, and 250.mu.m at 100Hz. Furthermore, the measurement accuracy the displacement amplitude was within -3% and average error -1.3%, when the shape of the sawtooth contained in the Doppler beat signal is clear and sharp. The measurement accuracy is found to depend on a degree of sawtooth asymmetry (DSA).

  • PDF

Discretization technique for stability analysis of complex slopes

  • Hou, Chaoqun;Zhang, Tingting;Sun, Zhibin;Dias, Daniel;Li, Jianfei
    • Geomechanics and Engineering
    • /
    • 제17권3호
    • /
    • pp.227-236
    • /
    • 2019
  • In practice, the natural slopes are frequently with soils of spatial properties and irregular features. The traditional limit analysis method meets an inherent difficulty to deal with the stability problem for such slopes due to the normal condition in the associated flow rule. To overcome the problem, a novel technique based on the upper bound limit analysis, which is called the discretization technique, is employed for the stability evaluation of complex slopes. In this paper, the discretization mechanism for complex slopes was presented, and the safety factors of several examples were calculated. The good agreement between the discretization-based and previous results shows the accuracy of the proposed mechanism, proving that it can be an alternative and reliable approach for complex slope stability analysis.