Browse > Article

Implementation of the Calculation Method for 95% Upper Limit of Effluent Water Quality of Sewage Treatment Plant for Total Maximum Daily Loads : Percentile Ranking Method  

Park, Jae Hong (Watershed Management Research Division, National Institute of Environmental Research)
Kim, Dong Woo (Watershed Management Research Division, National Institute of Environmental Research)
Oh, Seung-Young (Watershed Management Research Division, National Institute of Environmental Research)
Rhew, Doug Hee (Water Pollution Cap System Division, National Institute of Environmental Research)
Jung, Dong Il (Environmental Cap System Research Department, National Institute of Environmental Research)
Publication Information
Abstract
The evaluation of the effluent water quality of sewage treatment plant is one of the most important factor in calculating total maximum daily loads (TMDLs). Current method to calculate 95% upper limit of effluent water quality of sewage treatment plant assuming normal distribution of data needs to be implemented in case of non-normal distribution. We have investigated the applicability of percentile ranking method as a non-parametric statistical analysis in case of non-normal distribution of data.
Keywords
95th upper limit; Non-normal distribution; Non-parametric methods; Percentile ranking method; Reference discharge water quality;
Citations & Related Records
연도 인용수 순위
  • Reference
1 환경부(2002b). 낙동강수계 물관리 및 주민지원등에 관한 법률
2 Australian Government (2008). Guidelines for Managing Risks in Recreational Water
3 Hunter, P. R. (2002). Does calculation of the 95th percentile of microbiological results offer any advantage over percentage exceedence in determining compliance with bathing water quality standards? Letters in Applied Microbiology, 34, pp. 283-286   DOI   ScienceOn
4 환경부(2002a). 금강수계 물관리 및 주민지원등에 관한 법률
5 US EPA (1991). Technical Support Document For Water Quality-based Toxics Control
6 Bedient, P. B. and Huber, W. C. (1998). Hydrology and Floodplain Analysis, Addison-Wesley Publishing Company, Reading, Massachusetts, 650
7 Standing Committee of Analysts (2002). The Microbiology of Drinking Water - Part 3 - Practices and procedures for laboratories, Methods for the Examination of Waters and Associated Materials. Environment Agency
8 Standing Committee of Analysts (2007). The Microbiology of Drinking Water - Part 7 -Methods for the enumeration of heterotrophic bacteria, Methods for the Examination of Waters and Associated Materials. Environment Agency
9 US EPA (2007). TMDL for OAK CREEK (WBID 3192C)
10 환경부(2002c). 영산강.섬진강수계 물관리 및 주민지원등에 관한 법률
11 SPSS (1999). SPSS 10.0 for Windows and SmartViewer, Chicago
12 Berthouex, P. M. and Brown, L. C. (1996). Statistics for Environmental Engineers, Lewis Publishers
13 환경부(2006). 환경부훈령 685호
14 US EPA (2006). TMDL for BESSEY CREEK (WBID 3211)
15 환경부(2004). 수질오염총량관리 업무편람