• 제목/요약/키워드: up-sampling

검색결과 842건 처리시간 0.028초

Sampling Study on Environmental Observations: Precipitation, Soil Moisture and Land Cover Information

  • 유철상
    • 한국환경과학회지
    • /
    • 제5권2호
    • /
    • pp.103-112
    • /
    • 1996
  • Observational date is integral in our understanding of present climate, its natural variability and any cnange roue to anturopogenic effects. This study incorporates a brief overview of sampling requirements using data from the first ISLSCP Field Experiment (FIFE) in 1987, which was a multi-disciplinary field experiment over a 15km grid in Konza Prairie, USA. Sampling strategies were designed for precipitation and soil moisture measurements and also detecting land cover type. It was concludes that up to 8 raingages would be needed for valuable precipitation measurements covering the whole FIFE catchment, but only one soil moisture station. Results show that as new gages or station are added to the catchment then the sampling error is reduced, but the Improvement in error performance is less as the number of gages or stations increases. Sampling from remoteiy sensed instruments shows different results. It can be seen that the sampling error at 1arger resolution sizes are small due to competing error contribution from both commission and omission error.

  • PDF

A Case study of an optimal design with structured sampling and simulation

  • Park, Hongjoon;Youngcook Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.46.4-46
    • /
    • 2002
  • This study was motivated how it might be possible to validate structured sampling with orthogonal array for optimal design of a pin. The Taguchi method by orthogonal array, one of the structured sampling methods, has much advantage that is row cost and time saving for experiments. But this method has been applied in limited areas especially for mechanical problems. In this study, we experimented whether the structured sampling is useful for applying optimal design of mechanical elements. For the experiment, we first set up a mechanical problem which was related to determining optimal parameters associated a pin's crack occurred inside a hole. We, then, calculated combination of...

  • PDF

Audio Sampling Rate Conversion Block의 설계 (Design of Audio Sampling Rate Conversion Block)

  • 정혜진;심윤정;이승준
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.827-830
    • /
    • 2003
  • This paper proposes an area-efficient FIR filter architecture for sampling rate conversion of hi-fi audio data. Sampling rate conversion(SRC) block converts audio data sampled at 96KHz down to 48KHz sampled data and vice versa. 63-tap FIR filter coefficients have been synthesized that gives 100dB stop band attenuation and 5.2KHz transition bandwidth. Time-shared filter architecture requires only one multiplier and accumulator for 63-tap filter operation. This results in huge hardware saving of up to 10~19 times smaller compared with traditional FIR structure.

  • PDF

연약 점성토의 시료채취방법에 따른 시료교란도의 영향에 관한 연구 (A Study on the Disturbance Effects with Sampling Methods of Soft Clay)

  • 박춘식;장정욱;김종환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.577-584
    • /
    • 2002
  • We have employed two methods to remove slime at the end of the sampler in clay layers. The first method is a sampling process that harnesses low pressure to clean up the ground around the sampler tip. The second method, in consideration of a disturbed layer, involves a technique of inserting the sampler 50 cm deep into the ground before cleaning up the verge of the sampler by using high pressure. Physical and mechanical properties of these two methods have been compared and analyzed to investigate how different sampling methods affect degree of disturbance. The first method shows little disturbance since the unconfined compression test results in quite greater E$\_$50//q$\_$u/ in the first method than in the second method. On the other hand, the consolidation test results in a slightly greater compression index in the second method than in the first method, when their indexes are compared in the same depth. This suggests that the second method demonstrates less disturbance than the first method does. It is assumed that the second method may reduce disturbance slightly, However, we suspect that choosing any of the two methods would not obtain a considerable difference in sampling.

  • PDF

백색광 주사 간섭계의 측정 속도 개선을 위한 서브 샘플링 기법 연구 (Sub-sampling Technique to Improve the Measurement Speed of White Light Scanning Interferometry)

  • 천인범;주기남
    • 한국정밀공학회지
    • /
    • 제31권11호
    • /
    • pp.999-1006
    • /
    • 2014
  • In this investigation, we explain the sub-sampling technique of white light scanning interferometry (WLSI) to improve the measurement speed. In addition to the previous work using Fourier domain analysis, several methods to extract the height from the correlogram of WLSI are described with the sub-sampling technique. Especially, Fourier-inverse Fourier transformation method adopting sub-sampling technique is proposed and the phase compensation technique is verified with simulation and experiments. The main advantage of sub-sampling is to speed up the measurements of WLSI but the precision such as repeatability is slightly poor. In case of measuring the sample which has high height step or difference, the proposed technique can be widely used to reduce the measurement time.

Chorionic villus sampling

  • Shim, Soon-Sup
    • Journal of Genetic Medicine
    • /
    • 제11권2호
    • /
    • pp.43-48
    • /
    • 2014
  • Chorionic villus sampling has gained importance as a tool for early cytogenetic diagnosis with a shift toward first trimester screening. First trimester screening using nuchal translucency and biomarkers is effective for screening. Chorionic villus sampling generally is performed at 10-12 weeks by either the transcervical or transabdominal approach. There are two methods of analysis; the direct method and the culture method. While the direct method may prevent maternal cell contamination, the culture method may be more representative of the true fetal karyotype. There is a concern for mosaicism which occurs in approximately 1% of cases, and mosaic results require genetic counseling and follow-up amniocentesis or fetal blood sampling. In terms of complications, procedure-related pregnancy loss rates may be the same as those for amniocentesis when undertaken in experienced centers. When the procedure is performed after 9 weeks gestation, the risk of limb reduction is not greater than the risk in the general population. At present, chorionic villus sampling is the gold standard method for early fetal karyotyping; however, we anticipate that improvements in noninvasive prenatal testing methods, such as cell free fetal DNA testing, will reduce the need for invasive procedures in the near future.

Randomized Response Model with Discrete Quantitative Attribute by Three-Stage Cluster Sampling

  • Lee, Gi-Sung;Hong, Ki-Hak
    • Journal of the Korean Data and Information Science Society
    • /
    • 제14권4호
    • /
    • pp.1067-1082
    • /
    • 2003
  • In this paper, we propose a randomized response model with discrete quantitative attribute by three-stage cluster sampling for obtaining discrete quantitative data by using the Liu & Chow model(1976), when the population was made up of sensitive discrete quantitative clusters. We obtain the minimum variance by calculating the optimum number of fsu, ssu, tsu under the some given constant cost. And we obtain the minimum cost under the some given accuracy.

  • PDF

Aerosol Filtration/Sampling Device Based on Irrigated Rotating Wires

  • ;;이규원
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2000년도 추계학술대회 논문집
    • /
    • pp.265-267
    • /
    • 2000
  • The objective of this study is to analyze, design and evaluate a new gas cleanup or sampling system that will remove erosive, corrosive, and fouling contaminants present in an effluent stream as either solid or liquid particles providing a clean gas stream. The gas clean-up or sampling system considered in this study is an irrigated, rotating element device. The device consists of a central disk-like hub from which emanate radially wires or cylindrical elements. (omitted)

  • PDF

비선형 시스템의 디지털 Feedback 선형화 기법 (Digital Feedback Linerization of the Nonlinear System)

  • 이홍기;전홍태;김찬호
    • 전자공학회논문지B
    • /
    • 제31B권6호
    • /
    • pp.33-42
    • /
    • 1994
  • The sampling is inevitable in controlling the nonlinear continuous time system. This paper deals with digital feedback linearization problem which eliminates or reduces the effect of the sampling. Necessary and sufficient condition for reducing the sampling error up to O$(h^5)$ are obtained. Also, the effectiveness of our control scheme in accuracy and robustness is shown by comuter simulations.

  • PDF

스마트미디어를 위한 입체 영상의 깊이맵 화질 향상 및 업샘플링 기술 (Depth Map Enhancement and Up-sampling Techniques of 3D Images for the Smart Media)

  • 정재일;호요성
    • 스마트미디어저널
    • /
    • 제1권3호
    • /
    • pp.22-28
    • /
    • 2012
  • 스마트미디어가 보편화되면서 고화질의 3차원 영상과 깊이맵에 대한 필요성이 대두되고 있지만, 현재 기술로는 완벽한 깊이맵을 직접 획득하는 것이 불가능하다. 스테레오 정합으로 획득된 깊이맵은 모호한 텍스처를 갖는 영역에서 낮은 정확도를 가지며, 깊이 카메라를 통해 직접 깊이맵을 획득한 경우에는 센서 잡음이나 낮은 해상도 등의 문제가 발생하게 된다. 본 논문에서는 이미 획득된 깊이맵의 화질을 향상시키거나 고해상도로 변환하는 기술 동향을 살펴본다. 초기에 개발된 깊이맵만을 이용한 기술부터 대응되는 색상 영상 정보를 함께 이용한 기술을 소개하고, 최근 활발히 연구되고 있는 복합형 카메라를 이용하여 깊이맵 화질을 향상시키는 기술을 자세히 살펴본다.

  • PDF