• 제목/요약/키워드: university image

검색결과 25,681건 처리시간 0.064초

타이타늄 임플랜트 시편 내부에 설치한 자석의 자성강도에 따른 골형성 변화 (THE CHANGE OF BONE FORMATION ACCORDING TO MAGNETIC INTENSITY OF MAGNET PLACID INTO TITANIUM IMPLANT SPECIMENS)

  • 황윤태;이성복;최대균;최부병
    • 대한치과보철학회지
    • /
    • 제43권2호
    • /
    • pp.232-247
    • /
    • 2005
  • Purpose. The purposes of this investigation were to discover the possibility of clinical application in the areas of dental implants and bone grafts by investigating the bone formation histologically around specimen which was depending on the intensity of magnetic field of neodymium magnet inside of the specimens. Material and method. 1. Measurement of magnetic intensity - placed the magnet inside of the specimen, and measured the intensity of magnetic field around the 1st thread and 3rd thread of specimen 20 times by using a Gaussmeter(Kanetec Co., Japan). 2. Surgical Procedure - Male rabbit was anesthetised by constant amount of Ketamine (0.25ml/kg) and Rompun (0.25ml/kg). After incising the flat part of tibia, and planted the specimens of titanium implant, control group was stitched without magnet, while experimental groups were placed a magnedisc 500(Aichi Steel Co., Japan) or magnedisc 800(Aichi Steel Co., Japan) into it, fixed by pattern resin and stitched. 3. Management after the surgery - In order to prevent it from the infection of bacteria and for antiinflammation, Gentamycin and Ketopro were injected during 1 week from operation day, and dressed with potadine. 4. Preparation of histomorphometric analysis - At 2, 4 and 8 weeks after the surgery, the animals were sacrificed by excessed Ketamine, and then, specimens were obtained including the operated part and some parts of tibia, and fixed it to 10% of PBS buffer solution. After embedding specimens in Technovit 1200 and B.P solution, made a H-E stain. Samples width was 75$\mu$m . In histological findings through the optical microscope and using Kappa image base program(Olympus Co. Japan), the bone contact ratio and bone area ratio of each parts of specimens were measured and analyzed. 5. Statistical analysis - Statistical analysis was accomplished with Mann Whitney U-test. Results and conclusion. 1. In histomorphometric findings, increased new bone formation was shown in both control & experimental groups through the experiment performed for 2, 4 & 8 weeks. After 4 weeks, more osteoblasts and osteoclasts with significant bone remodeling were shown in experimental groups. 2. In histomorphometric analysis, the bone contact ratios were 38.5% for experimental group 1, 29.5% for experimental group 2 and 11.9% for control group. Experimental groups were higher than control group(p<0.05) (Fig. 6, Table IV). The bone area ratios were 60.9% for experimental group 2, 46.4% for experimental group 1 and 36.0% for control group. There was no significantly statistical difference between experimental groups and control group(p<0.05) (Fig. 8, Table VII) 3. In comparision of the bone contact ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group at the 1st thread (p<0.05) and experimental group 1 (1.8mT) was higher than control group at the 3rd thread(p<0.05) (Fig. 7, Table V, VI). 4. In comparision of the bone area ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group and experimental group 1 (4.0mT) at the 1st thread(p<0.1) and experimental group 2(4.4mT) was higher than experimental group 1 (1.8mT) at the 3rd thread(p<0.1) (Fig. 9, Table IX, X). Experiment group 2 was largest, followed by experiment group l and control group at the 3rd thread of implant. There was a significant difference at the 1st thread of control group & experiment group 2, and at 1st thread & 3rd thread of experiment group 1 & 2, and not at control group experiment group 1.(p<0.1)

순차 연관 규칙을 이용한 개인화된 전시 부스 추천 방법 (Personalized Exhibition Booth Recommendation Methodology Using Sequential Association Rule)

  • 문현실;정민규;김재경;김혜경
    • 지능정보연구
    • /
    • 제16권4호
    • /
    • pp.195-211
    • /
    • 2010
  • 전시회는 전시업체가 새로운 상품이나 서비스를 관람객에게 알리기 위해 개최되는 것으로 효과적인 마케팅 수단으로 중요한 역할을 수행한다. 전시회를 방문하는 다양한 관람객의 니즈를 충족시키기 위하여 다양한 유비쿼터스 기술이 전시회에 응용되고 있지만 관람객이 사전에 요청한 정보만을 제공함으로 개별 관람객의 선호가 반영되지 않아 관람객의 니즈를 충족시키기에는 한계가 있다. 이러한 한계를 해결하기 위한 방법으로 개인의 선호에 부합하는 부스를 추천하는 추천 시스템의 이용이 가능하다. 추천시스템은 전시 환경에서 관람객의 선호를 추론하여 선호에 부합하는 방문 부스를 추천하여 관람객의 니즈를 충족시킬 수 있다. 그러나 추천 시스템 중 가장 성공적으로 평가 받는 기존의 협업 필터링은 관람객의 부스 방문 순서에 나타나는 선호를 반영하지 않아 동적으로 변화하는 선호를 가지는 관람객으로 구성된 전시 환경의 추천 시스템으로는 적합하지 않다. 따라서 본 연구에서는 관람객의 방문 순서를 고려하는 기법 중 순차 연관 규칙을 이용하여 관람객의 선호에 부합하는 부스를 추천하는 방법론을 제안하였다. 본 연구에서 제안한 방법론의 성과 측정을 위해 실제 전시회에서 획득한 데이터를 사용하여 기존의 협업 필터링과 비교한 결과 전체적으로 추천의 성과가 향상되어 향후 전시 환경에서의 부스 추천시스템에 적용하여 관람객의 니즈를 충족시킬 것으로 기대된다.

금속선 강화에 따른 열 가압 도재의 파절저항 (The fracture resistance of heat pressed ceramics with wire reinforcement)

  • 조득원;동진근;오상천;김유리
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.191-198
    • /
    • 2009
  • 연구목적: 본 연구는 높은 심미성을 나타내지만 낮은 파절 강도로 인하여 구치부에서의 사용이 제한되고 있는 전부도재 고정성 국소의치의 파절강도를 증가시키기 위한 방법으로, 취성 재료인 도재에 인장강도가 높은 금속선을 삽입하고 물리적, 기계적 성질을 알아보고자 하였다. 연구 재료 및 방법: lithium disilicate(ingot No.200 : IPS Empress 2, Ivoclar Vivadent, Lichtenstein)와 0.41 mm 직경의 Ni-Cr 금속선(Alfa Aesar, Johnson Matthey Company, USA)을 사용하여, 금속선의 수와 배열을 달리한 4개의 실험군 시편을 제작하였다. 모든 시편은 폭 4 mm, 두께 2 mm, 길이 15 mm의 직육면체로 제작하였다. 실험군 1, 2, 3은 각각 한 가닥, 두 가닥, 세 가닥의 금속선을 도재 시편의 장축을 따라 배열하였으며, 실험군 4는 세 가닥의 금속선을 도재 시편의 장축에, 다섯 가닥의 금속선을 도재 시편의 횡축에 배열하였다. 대조군에는 금속선을 삽입하지 않았으며, 대조군 및 각각의 실험군의 시편은 각 군당 12개로 하였다. 결과: 만능 시험기(Z020, Zwick, Germany)를 이용하여 파절시점까지 하중을 가한 후, 굴곡계수, 굴곡강도, 파절시점까지의 변형률, 파괴인성을 측정하였다. 파절된 시편의 도재와 금속선의 계면을 횡절단 및 연마하여 주사전자현미경(JSM-6360, JEOL, Japan)으로 100배상에서 관찰하였다. 결과는 다음과 같다. 1. 도재에 금속선을 삽입한 결과, 금속선을 삽입하지 않은 대조군에 비해 통계적 유의성 있는 굴곡계수 및 굴곡강도의 변화는 관찰할 수 없었으나, 변형률의 유의성 있는 증가(P<.001)를 관찰할 수 있었다. 2. 금속선을 삽입한 시편의 파절 양상은 하중점 부위에서 도재만 파절되는 양상을 나타내었다. 3. 금속선을 삽입한 도재의 파절된 시편을 횡절단 및 종절단하여 100 배상에서 주사전자현미경으로 촬영한 결과, 하중 시 도재의 파절 원인이 될 수 있는 도재 내부의 기포는 관찰되지 않았으며, 도재와 금속선 사이의 gap도 관찰되지 않았다. 결론: 금속선 삽입의 결과, 취성 재료인 도재의 통계적으로 유의성 있는 변형률의 증가를 관찰할 수 있었다. 그러나 구치부에서 금속선 강화 도재의 사용을 위해서는 굴곡계수 및 굴곡강도의 향상이 필요하다. 이를 위해서는 추가적 연구가 필요하다.

경사지게 식립된 임플랜트 모형에서 지대주를 인상용 코핑으로 이용한 새로운 인상법의 정확성 비교 연구 (Comparative accuracy of new implant impression technique using abutments as impression copings with an angulated implant model)

  • 이혁재;김창회;임영준;김명주
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.201-208
    • /
    • 2008
  • 연구목적: 시멘트 유지형 지대주를 인상용 코핑으로 이용하고 레진이나 금속 구조물에 접착하여 스플린팅하는 새로운 인상법을 시도하였다. 연구의 목적은 첫 번째, 3개의 임플랜트가 $15^{\circ}$ 경사지게 식립된 모형에서 closed tray 인상법과 레진 스플린팅한 open tray 인상법의 정확성을 비교하는 것이고 두 번째, 새로운 인상법의 정확성을 앞의 두 가지 인상법과 비교하는 것이다. 연구 재료 및 방법: 3개의 임플랜트 아날로그가 선상으로 배열되고 가운데 아날로그는 모형에 수직이고 양쪽 끝 아날로그는 이것에 앞뒤로 $15^{\circ}$ 경사지게 배열된 주모형과 주모형에 잘 적합되는 기준구조물을 제작하였다. closed tray 인상법, 레진 스플린팅한 open tray 인상법, 지대주-레진구조물 접착 인상법, 지대주-금속구조물 접착 인상법, 각 10개씩 40번의 인상을 채득하여 복제모형을 제작하였다. 이미지 처리할 수 있는 광학 현미경을 이용하여 기준구조물과 복제모형내의 아날로그와의 수직간격을 측정하여 인상의 정확성을 평가하였다. 통계처리는 one-way ANOVA와 사후 검정으로 Tukey test를 5% 유의수준으로 시행하였다. 결과: closed tray 인상법;74.3 (${\pm}33.4$)${\mu}m$의 간격은 레진 스플린팅한 open tray 인상법과 다른 두 가지 새로운 인상법보다 간격의 크기가 통계적 유의성 있게 컸다(P<.05). 지대주-금속구조물 접착 인상법;42.5 (${\pm}11.9$)${\mu}m$은 다른 인상법들 보다 간격의 크기가 통계적 유의성 있게 작았다(P<.05). 지대주-레진구조물 접착 인상법;51.0 (${\pm}14.1$)${\mu}m$은 레진 스플린팅한 open tray 인상법50.3 (${\pm}16.9$)${\mu}m$과 통계적 유의성 있는 차이를 보이지 않았다(P>.05). 결론: 이 연구의 한계 내에서, 레진 스플린팅한 open tray 인상법은 closed tray 인상법보다 우수한 정확성을 나타내었고, 지대주를 금속구조물에 접착하는 새로운 인상법의 정확성은 레진 스플린팅한 open tray 인상법보다 우수하였다.

골격성 III급 부정교합자의 Nasal Airway 형태에 관한 3차원적 분석 연구 (The Three Dimensional Analysis on Nasal Airway Morphology in Class III Malocclusion)

  • 김문환;이진우;차경석;정동화
    • 구강회복응용과학지
    • /
    • 제24권4호
    • /
    • pp.389-403
    • /
    • 2008
  • 서양인에 비해 한국인에서 호발 하는 III급 부정교합은 함몰된 중안모와 더불어 돌출된 하순과 하악골로 인해 기능적, 심미적, 심리적 문제를 야기하게 된다. 이러한 인종적 특성에 따른 발생 빈도의 차이에 따라 기존의 연구들은 주로 nasal airway 폐쇄와 II급 부정교합과의 관계에 대한 것이 대부분이었다. 또한 이러한 연구들은 자료 채득이 용이한 반면 2차원적 한계를 가지고 있는 측모 두부방사선 계측사진을 이용한 연구가 대부분이었다. 이에 본 연구는 III급 부정교합자와 정상교합자의 nasal airway의 형태를 3차원 전산화 단층촬영을 통해 얻어진 입체 영상으로 재구성한 모델을 이용하여 비교해 보고자 시행되었다. 연구 대상으로서 실험군으로 골격성 III급 부정교합으로 진단되어 악교정 수술을 위한 술 전 교정치료를 받기로 예정된 총 16명(남성 7명,여성 9명)과 대조군으로 임상적으로 정상적인 교합관계를 보이며 교정치료와 보철치료의 경험이 없는 정상 교합자 13명(남성 7명,여성 6명)을 선정 하였다. 두개골의 전산화 단층촬영(Computed Tomograph / CT)을 시행한 후 얻은 영상정보를 이용하여 nasal airway와 두개골의 3차원 입체영상을 제작하였다. 이러한 입체영상을 가지고 nasal airway의 절대적, 상대적 부피, 단면적의 비교를 시행하였으며 결과는 다음과 같았다. 1. 두 군 사이에 절대적 상기도 부피 비교에 있어서 실험군의 구인두 크기가 대조군에 비해 크게 나타났으며, 나머지 항목에서는 두 군 사이에 유의한 차이가 나타나지 않았다. 2. 두 군 사이에 상대적 상기도 부피 비교에 있어서 실험군의 구인두 부피가 대조군에 비해 크게 나타났으며, 나머지 항목에서는 두 군 사이에 유의한 차이는 나타나지 않았다. 3. 두 군 사이에 구인두 폭경변화 양상은 유사하게 나타나 하방으로 갈수록 점점 감소하다 다시 증가하는 양상을 보였으며 모든 부위에서 대조군에 비해 실험군의 평균 폭경이 크게 나타났다. 4. 측면에서의 상기도 평균 기도 만곡도를 나타내는 그래프 상에 있어서 두 군 사이에 유사한 양상이 나타났다.

합곡(合谷)$(LI_4)$에 행(行)한 염전보사(捻轉補瀉) 침자극(鍼刺戟)이 적외선(赤外線) 체열(體熱) 촬영(撮影)을 이용(利用)한 수양명대장경(手陽明大腸經)의 오수혈(五輸穴)과 영향(迎香)($(LI_{20})$)영역(領域)의 온도변화(溫度變化)에 미치는 영향(影響) (The Effects on the Thermal Changes of Five-Shu-Points(五輸穴) and Yonghyang$(LI_{20}$,迎香) of the Large Intestine Meridian with the Rotated Acupuncture-Bu-Xie(捻轉補瀉) on the Hapkok$(LI_4$,合谷), Using the D.I.T.I.)

  • 송범용;김경식;손인철
    • Korean Journal of Acupuncture
    • /
    • 제17권1호
    • /
    • pp.47-65
    • /
    • 2000
  • The meridian, the meridian point and the Acupuncture-Bu-Xie(鍼灸補瀉) of oriental medicine are very important in the Department of Acupuncture and Moxibustion. Until now it has been confused at the practical use, and it showed up many transformation to the ages and many scholars. And then, I made a study of effects on the thermal changes of Sangyang($LI_1$,商陽), Igan($LI_2$,二間), Samgan($LI_3$,三間), Hapkok($LI_4$,合谷), Yanggye($LI_5$,陽谿), Kokchi($LI_{11}$,曲池), Yonghyang($LI_{20}$,迎香) following acupuncture on the Hapkok with the Rotated Acupuncture-Bu-Xie(捻轉補瀉) stimulation. This study researched into clinical statistics for 140 men who are in good health, and they are studying oriental medicine at Woosuk university in Korea. This study was covered a period of 3 months form June, 1999 to August, 1999. The objective was divided into seven groups, those are the control group(CON, N=20), the acupuncture stimulation group with non-rotation on Hapkok of left hand(A-I, N=20), the acupuncture stimulation group with non-rotation on non-meridian point(NA) of left hand(A-II, N=20), the acupuncture stimulation group with Bu-rotation(捻轉補法) on Hapkok of left hand(B-I, N=20), the acupuncture stimulation group with Bu-rotation on non-meridian point(NA) of left hand(B-II, N=20), the acupuncture stimulation group with Xie-rotation(捻轉瀉法) on Hapkok of left hand(C-I, N=20), and the acupuncture stimulation group with Xie-rotation on non-meridian point of left hand(C-II, N=20). The first, I took a picture for 140 men with the Digital infrared thermal image(D.I.T.I.). After 10 minutes, I took a second picture for each group following experimental methods, those were followed acupuncture on the Hapkok and the non-meridian point with the retentive and Rotated Acupuncture-Bu-Xie stimulation. The results are summarized as follows : 1. The thermal changes of the area which is a meridian point in the Large Intestine Meridian of the acupuncture stimulation group on Hapkok different from the control groups with significantly change. 2.The thermal changes of the area which is a meridian point in the Large Intestine Meridian of acupuncture stimulation groups on non-meridian point was not significantly different from the control group. 3. The thermal changes of the area which is a meridian point in the Large Intestine Meridian of the acupuncture stimulation group with Bu-rotation on Hapkok different from the control group with significant increase. 4. The thermal changes of the area which is a meridian point in the Large Intestine Meridian of acupuncture stimulation group with Bu-rotation on non-meridian point was not significantly different from the control group. 5. The thermal changes of the area which is a meridian point in the Large Intestine Meridian of the acupuncture stimulation group with Xie-rotation on Hapkok different from the control group with significant decrease and increase following the decreasing or increasing temperature class, and the increasing temperature class of the acupuncture stimulation group with Xie-rotation on Hapkok significantly different from the acupuncture stimulation group with Bu-rotation on Hapkok. 6. The thermal changes of the area which is a meridian point in the Large Intestine Meridian of acupuncture stimulation group with Xie-rotation on non-meridian point was not significantly different from the control group. As a conclusion, I could think that the acupuncture stimulation with Bu-rotation or Xie-rotation on Hapkok affected the thermal change of the area which is a meridian point in the Large Intestine Meridian. And then I could relate these results with the existence of the meridian and meridian point, and with the Rotated Acupuncture-Bu-Xie theory of oriental medicine.

  • PDF

엔진구동형 NiTi 파일의 근관성형효과 비교 (A COMPARISON OF THE SHAPING ABILITY OF FOUR ROTARY NICKEL-TITANIUM FILES IN SIMULATED ROOT CANALS)

  • 김보혜;최경규;박상혁;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제35권2호
    • /
    • pp.88-95
    • /
    • 2010
  • 이 연구의 목적은 4가지 엔진구동형 NiTi 기구의 근관성형력을 비교하는 것이다. 32개의 투명레진모형을 사용하여 파일의 단면도가 S자 형태이고 "single length"방법으로 근관성형을 시행하는 Mtwo와 crown-down 방법으로 근관성형을 하는 Profile, ProTaper Universal 및 K3로 근관성형을 하였다 (n = 8). 모든 근관은 한사람의 술자가 근단공 크기가 #30이 될 때까지 성형하였다. 기구 사용 전과 후 근관 모양을 디지털 영상을 기록하였고, 컴퓨터 영상 분석 프로그램(Expression Scanner와 Adobe Photoshop CS)으로 평가하였다. 다음과 같은 결론을 얻었다. 근첨으로부터 1, 2, 3, 4, 5, 6, 7 mm 떨어진 부위의 내측과 외측으로 삭제된 레진 양을 측정하였고, 자료는 SPSS법으로 비교 분석하였다. 1. 근관형성 시간은 Mtwo가 84.50초로 가장 짧았으며, 총 작업시간은 K3가 269.37초로 가장 길었다(p < 0.05). 2. 기구의 변형과 파절은 모든 구동형 NiTi 파일에서 발생하지 않았다. 3. 근관 내측 폭경의 변화는 Profile이 1, 2 mm 부위를 제외한 다른 부위에서 가장 적었으며, ProTaper Universal은 모든 부위에서 가장 많았다(p < 0.05). 4. 근관 외측 폭경의 변화는 Mtwo이 1 mm 부위를 제외한 모든 부위에서 가장 적었으며, Profile은 3, 4 mm 부위에서 가장 많았다(p < 0.05). ProTaper Universal와 K3는 1, 2, 6, 7 mm 부위에서 가장 많았다(p < 0.05). 5. 근관중심변위율(centering ratio)은 Profile이 1, 4, 5, 6 mm 부위에서 가장 적었다(p < 0.05). 이상의 결과, 구동성 NiTi 파일을 이용한 만곡 근관의 근관형성은 치경부는 ProTaper와 같은 삭제력이 높은 파일을 사용하는 것이 근관 입구를 효과적으로 넓히고 더 나은 taper를 형성하며, 근단부는 Profile과 같은 근관 중심 변위가 적은 파일을 사용하는 것이 근관형성 시간을 단축하고 근단부의 근관 변형(transportation)을 줄일 수 있다고 판단된다.

CT 검사 시 스캔 범위 내 상지 유무에 따른 영상의 질 평가(LUNG MAN 포함) (Evaluation of Image Quality According to Presence or Absence of Upper limbs in Scan Field of View During CT Examinations (Including LUNG MAN))

  • 장위잉;정하오양;정강교;조유진;조평곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.567-573
    • /
    • 2017
  • 본 연구의 목적은 흉 복부 다중검출기전산화단층촬영(multi-detector computed tomography; MDCT)에서 상지를 머리 위로 위치 잡이 할 수 없는 경우 흉 복부에서 거리에 따른 인공유무를 평가하고자 하였다. 128-채널 MDCT로 흉 복부 CT를 위한 인체대상과 흉부 팬텀을 현재 임상에서 검사하고 있는 조건(120 kVp, 110 mAs, standard algorithm)으로 검사하였다. 인체 검사 시 한번은 팔을 머리 쪽으로 올리고 검사하고, 팔을 내린 후 동일한 조건으로 한 번 더 검사하였다. 흉부 팬텀 실험은 환자와 동일한 조건으로 검사를 하고, 상지팬텀을 흉 복부에서 일정한 거리(0, 3, 7 cm)를 두고 검사하였다. 목적하는 부위에 관심영역을 설정하여 CT 값, 노이즈, 신호 대 잡음비, 대조도 대 잡음비를 측정하여 평가하였다. 인체를 대상으로 획득한 영상에서 노이즈는 팔을 올렸을 때와 비교하여 팔을 내렸을 때 지방, 갈비뼈, 근육 모두에서 증가하였다(0.79, 47.8, 27%). 팬텀 영상에서도 상지를 아래로 내렸을 경우 근육, 폐 실질에서 노이즈가 증가하였다(31.2, 9.4%). 또한 상지의 위치가 흉 복부에서 멀어질수록(0, 3, 7 cm) 노이즈가 감소하였다. 근육에서 노이즈는 상지가 흉부와 붙어있을 경우(0 cm)를 기준으로 3 cm, 7cm 떨어졌을 때 5, 25.12% 감소하였고, 폐실질에서 5.6, 15.35% 감소하였다. 흉 복부 CT 촬영 시 갠트리 내 검사 이외의 부위(상지 등)가 위치할 경우 흉 복부로부터 약 3 cm 이상 거리를 유지시킨 후 검사를 진행하면 발생할 수 있는 인공음영을 최소화시킬 수 있을 것으로 사료된다.

가우시안 군집분석을 이용한 천리안 위성의 대기운동벡터 표적추적 알고리듬 개발 및 분석 (Development and Analysis of COMS AMV Target Tracking Algorithm using Gaussian Cluster Analysis)

  • 오유림;김재환;박형민;백강현
    • 대한원격탐사학회지
    • /
    • 제31권6호
    • /
    • pp.531-548
    • /
    • 2015
  • 위성영상을 이용하여 산출된 대기운동벡터(AMV)와 라디오존데 바람 관측 자료를 이용한 검증결과는 산출된 AMV가 지속적으로 관측 자료에 비해서 풍속이 약하게 나타나는 Slow Speed Bias(SSB)를 보여 주었다. 이러한 SSB는 표적추적, 표적선정, 그리고 고도할당 단계의 오차에 의해 야기될 수 있으며, 이 중 고도할당 단계의 오차는 SSB를 발생시키는 주된 요인으로 여겨진다. 그러나 최근 연구에서는 고도할당 단계의 개선만으로는 SSB 문제를 해결하는데 한계가 있음을 밝혔다. 그러므로 본 연구에서는 새로운 표적추적 알고리듬을 개발하여 SSB를 감소시킴으로서 기상청 현업 AMV 알고리듬의 성능을 개선하고자 하였다. 표적추적 단계의 오차는 표적 내에 다양한 시 공간 규모의 바람이 포함되어 벡터가 과도하게 평균된 움직임으로 계산되거나, 구름이 추적 시간동안 형태를 유지하지 못하고 변형되는 경우에 발생한다. 이러한 문제를 해결하기 위해 개발된 표적추적 알고리듬에서는 가우시안 군집분석(GMM)을 이용하여 변형이 적고 추적에 용이한 저온 군집을 표적으로 재선정하고, 이미지를 변형시켜 군집의 움직임을 보다 쉽게 추적할 수 있게 하였다. 또한 표적을 추적하기 위한 방법으로 거리제곱합 방법을 사용하였다. 개발된 알고리듬과 기존 COMS 알고리듬을 천리안 위성의 적외채널 영상에 적용하여 AMV를 산출하였으며, 이를 라디오존데 관측 자료와 비교 검증해 보았다. 제안된 알고리듬으로 산출된 AMV는 기존 알고리듬으로 산출된 AMV보다 평균 풍속이 $2.7ms^{-1}$증가함에 따라 SSB가 평균 29%까지 감소하는 개선된 결과를 보여주었다. 그러나 개발된 알고리듬으로 산출된 AMV는 중 하층의 정확도가 감소하였고, 기존 알고리듬에 비해 산출되는 AMV 벡터수가 약 40%까지 감소함을 보였다. 이에 따라 중 하층의 정확도 개선과 기존의 알고리듬과 비교하여 산출되는 벡터 개수가 감소하는 문제를 보완하기 위한 연구가 필요할 것으로 판단된다.

토끼 관절 연골세포의 증식과 글리코스아미노글리칸 합성에 대한 808-nm 다이오드 레이저의 효능 평가 (In Vitro Effect of 808-nm Diode Laser on Proliferation and Glycosaminoglycan Synthesis of Rabbit Articular Chondrocytes)

  • ;황야원;최석화;김근형
    • 한국임상수의학회지
    • /
    • 제32권4호
    • /
    • pp.295-300
    • /
    • 2015
  • 본 연구의 목적은 알지네이트 비드에서 배양한 토끼의 관절 연골세포의 증식과 황산화 글리코스아미노글리칸 합성에 대한 808-nm InGaAs 다이오드 레이저의 효과를 확인하는 것이다. 이전의 연구들에서 서로 다른 종류의 세포에서 레이저의 양성 또는 음성 자극 효과가 알려졌다. 알지네이트 비드 내의 토끼 연골세포에 1.0W 세기의 808-nm InGaAs 다이오드 레이저가 $31J/cm^2$ (1 그룹), $62J/cm^2$ (2 그룹)의 에너지 밀도로 상응하는 그룹에 10초, 20초 동안 24, 48, 72, 96시간째에 각각 조사되었다. 대조군은 처리하지 않았다. 1차 레이저 조사 1주, 2주 후에 MTT 분석이 실시되었다. 황산화 글리코스아미노글리칸 합성은 DMMB 분석을 통해 평가되었다. 조직학적 평가를 위한 세포의 분포와 세포 주변의 황산화 글리코스아미노글리칸 침착은 알시안 블루 염색을 통해 평가되었다. MTT 분석을 통해 알지네이트 비드에서 세포 증식에는 양성 자극 효과가 없음을 알 수 있었다. DMMB 분석을 통해서 2 그룹의 2주차 연골세포에서 황산화 글리코스아미노글리칸 생성이 특이적으로 증가했음을 알 수 있었다. 알시안 블루 염색상에서도 2 그룹 연골세포에서 양성 염색상이 특이적으로 많은 비율을 차지함을 알 수 있었다. 본 연구를 통해 1.0 W 세기의 808-nm InGaAs 다이오드 레이저가 연골세포 증식에 영향이 없으나 알지네이트 비드에서 세포 분비 활동을 자극하여 황산화 글리코스아미노글리칸 침착을 증가시킬 수 있음을 확인하였다.