• Title/Summary/Keyword: unit module

Search Result 834, Processing Time 0.021 seconds

A Study on Implementation of Emotional Speech Synthesis System using Variable Prosody Model (가변 운율 모델링을 이용한 고음질 감정 음성합성기 구현에 관한 연구)

  • Min, So-Yeon;Na, Deok-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.8
    • /
    • pp.3992-3998
    • /
    • 2013
  • This paper is related to the method of adding a emotional speech corpus to a high-quality large corpus based speech synthesizer, and generating various synthesized speech. We made the emotional speech corpus as a form which can be used in waveform concatenated speech synthesizer, and have implemented the speech synthesizer that can be generated various synthesized speech through the same synthetic unit selection process of normal speech synthesizer. We used a markup language for emotional input text. Emotional speech is generated when the input text is matched as much as the length of intonation phrase in emotional speech corpus, but in the other case normal speech is generated. The BIs(Break Index) of emotional speech is more irregular than normal speech. Therefore, it becomes difficult to use the BIs generated in a synthesizer as it is. In order to solve this problem we applied the Variable Break[3] modeling. We used the Japanese speech synthesizer for experiment. As a result we obtained the natural emotional synthesized speech using the break prediction module for normal speech synthesize.

Design and Stability Analysis of MAP Network Management Module (MAP 네트워크 관리 모듈의 설계와 안정성 해석)

  • 김정호
    • Journal of the Korean Professional Engineers Association
    • /
    • v.28 no.3
    • /
    • pp.121-134
    • /
    • 1995
  • To operate the automatic devices of manufacturing process more effectively and to solve the needs of the resource sharing, network technology is applied to the unit con-trol devices located In common manufacturing zone and operated by connecting them. The network management system, which controls and supervises the network resources in the communication network, is the function that is necessarily required in this net-work. For the stability in this network, this paper measures the variation of data packet length and node number and analyzes the variated value of the token rotation time and waiting time for the network operation. On the evalution of the performance, the data packet length varies from 10 bytes to 100 bytes in the operation of the group manage-ment network, the variation of the token rotation time and waiting time is less than 10 msec. When the variation of the data packet lenhth is less than 50 bytes, differences in token rotation time or waiting time is unnoticable. Since the waiting time in this case is less than 10 msec, response time Is fast enough.

  • PDF

Development a High-Efficiency Induction Heating Heater using a 5[kW] Class Full-Bridge High Frequency Resonant Inverter (5[kW]급 풀-브릿지 고주파 공진형 인버터를 이용한 고효율 유도가열 히터 개발)

  • Kwon Hyuk-Min;Shin Dae-Cheul
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.481-487
    • /
    • 2005
  • Proposed induction-heated system is innovative system which applied special high-frequency power circuit technique for thermal converse technique and IH(Induction-Heating) magnetic induction heating generated from induction-heated metallic package that is for distillation unit. In this occurs not burning, so that the working environment can be improved. This electromagnetic induction heating technique is used high frequency inverter, By using high frequency inverter high frequency alternative current in the range of [kHz] can be made with conventional alternative current. In this contribution IGBT module is used for high frequency inverter. This paper proposes new fluid heating method. Which is operated as follows. Working coil, which is wrapped outside of pipeline, makes the eddy current. Inside of heating vessel in isolated pipeline the specially designed stainless metallic package is inserted, which can be heated by eddy current losses. And then In this paper are discussed action analysis and characteristics analysis of 5[kW] class full-bridge resonant inverter system and resonant metallic package. In addition, by using this system, how high-efficiency heater is developed and application of system are also discussed.

The Analysis of View and Daylights for the Design of Public Housing Complexes Using a Residential Environment Analysis System Integrated into a CAD System (주거환경분석시스템의 CAD 시스템 통합을 통한 공동주택단지설계 시 일조 및 조망분석에 관한 연구)

  • Park, Soo-Hoon;Ryu, Jeong-Won
    • Korean Journal of Computational Design and Engineering
    • /
    • v.12 no.2
    • /
    • pp.137-145
    • /
    • 2007
  • This paper concerns about residential environment analysis program implementation for design and analysis on public housing complexes such that view and daylight analysis processes are automated and integrated into existing design routine to achieve better design efficiency. Considering the architectural design trends this paper chooses ArchiCAD as a platform for a CAD system, which contains the concepts such as integrated object-oriented CAD, virtual building and BIM. Residential environment analysis system consists of three components. The first component is the 3D modeling part defining 3D form information for external geographic contour models, site models and interior/exterior of apartment buildings. The second is the parametric library part handling the design parameters for view and daylight analysis. The last is the user interface for the input/output and integration of data for the environment analysis. Daylight analysis shows rendered images as well as results of daylight reports and grades per time and performs the calculations for floor shadow. It separates the site-only analysis from the analysis of site and exterior environmental parameters. View analysis considers horizontal and vertical view angles to produce view image from each unit and uses the bitmap analysis method to determine opening ratio, scenery ratio and void ratio. We could expect better performance and precision from this residential environment analysis system than the existing 2D drawing based view and daylight analysis methods and overcome the existing one-way flow of design information from 3D form to analysis reports so that site design modifications are automatically reflected on analysis results. Each part is developed in a module so that further integration and extension into other related estimation and construction management systems are made possible.

A Study on F. L. Wright's Interpretation of the Space and the Method of the Composition in his architectural works (Frank Lloyd Wright의 건축작품에 나타난 라이트의 공간 해석과 구성방법에 관한 연구(硏究))

  • Oh, Zhang-Huan;Lee, Kang-Up
    • Journal of architectural history
    • /
    • v.7 no.4 s.17
    • /
    • pp.29-47
    • /
    • 1998
  • The aim of this study is to understand the original methods of architectural composition in F. L. Wright's works, For this purpose, the principal thoughts based on his organic architecture was examined over all others, and the results of this study are as follows. 1. F. L. Wright knew Taoist Philosophy, especially Lao-tzu's thought about space based on traditional oriental arts included traditional japanese arts by his superior intuition. this is similar to Froebel Thought in the principal theory, that is, his own unique field of abstract architectural education with three-dimensional geometry learned through Froebel Gifts. 2. Space is reality ; such Lao-tzu's thought, reversed the sense of values, influenced F. L. Wright's way to accomplish his own continuous space. that is to say, he attempted taking precedence of spatial organization by the unit of three-dimensional module made the substance, Froebel Blocks (3, 4, 5, 6 Gifts) into non-substance, and trying to do the methods of continuous liberal composition in architecture. which is his original accomplishment, namely his mentioned 'democratic' because of judging the space and the mold of architecture as individualities. 3. F. L. Wright treated the space as a positive entity, so that he created his own architecture organically combined with spaces and forms. : This was the result that he comprehended both formative, physical worth in West and spatial, non-physical worth in East as equivalence. It is understood that F. L. Wright's works combined with East and West are the significance of his architecture and the progress of true internationalities and modernization in modern architecture. 4. From the analyses of his works, we knew the fact that F. L. Wright's architecture, especially in the spatial organization were performed by the reasonable methods with geometric system of Froebel Gifts. In the observation of our fundamental way of thinking on his architecture, this study shows the necessity to let us get out of preconceptions and conclusions that the organic architecture is mysterious and difficult, but to systematize and put his organic methods to practical use.

  • PDF

A Study on Optimal Design of 100 V Class Super-junction Trench MOSFET (비균일 100V 급 초접합 트랜치 MOSFET 최적화 설계 연구)

  • Lho, Young Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.109-114
    • /
    • 2013
  • Power MOSFET (metal-oxide semiconductor field-effect transistor) are widely used in power electronics applications, such as BLDC (Brushless Direct Current) motor and power module, etc. For the conventional power MOSFET device structure, there exists a tradeoff relationship between specific on-state resistance and breakdown voltage. In order to overcome the tradeoff relationship, a non-uniform super-junction (SJ) trench MOSFET (TMOSFET) structure for an optimal design is proposed in this paper. It is required that the specific on-resistance of non-uniform SJ TMOSFET is less than that of uniform SJ TMOSFET under the same breakdown voltage. The idea with a linearly graded doping profile is proposed to achieve a much better electric field distribution in the drift region. The structure modelling of a unit cell, the characteristic analyses for doping density, and potential distribution are simulated by using of the SILVACO TCAD 2D device simulator, Atlas. As a result, the non-uniform SJ TMOSFET shows the better performance than the uniform SJ TMOSFET in the specific on-resistance at the class of 100V.

Annual Energy Performance Evaluation of Zero Energy House Using Metering Data (실측데이터를 이용한 에너지제로주택의 연간 에너지성능평가)

  • Lim, Hee-Won;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.113-119
    • /
    • 2016
  • Purpose: In this study, we evaluate the annual energy performance of the detached house which was designed with the aim of zero energy. Method: The experimental house which was constructed in Gonju Chungnam in 2013, is the single family detached house of light weight wood frame with $100m^2$ of heating area. Thermal transmittance of roof (by ISO 10211) and building external walls are designed as $0.10W/m^2K$ and $0.14W/m^2$ respectively and low-e coating vacuum window glazing with PVC frame was installed. Also grid connected PV system and natural-circulation solar water heater was applied and 6kWp capacity of photovoltaic module was installed in pitched roof and $5m^2$ of solar collector in vertical wall facing the south. We analyzed the 2014 annual data of the detached house in which residents were actually living, measured though web-based remote monitoring system. Result: First, as a result, total annual energy consumption and energy production (PV generation and solar hot water) are 7,919kWh and 7,689kWh respectively and the rate of energy independence is 97.1% which is almost close to the zero energy. Second, plug load and hot water of energy consumption by category showed the highest numbers each with 33% and 31%, with following space heating 24%, electric cooker 8%, lighting 3% in order. Hot water supply is relatively higher than space heating because high insulation makes it decreased.

Door-Lock System to Detect and Transmit in Real Time according to External Shock Sensitivity (외부 충격 감도에 따른 실시간으로 탐지하고 전송하는 Door-Lock 시스템)

  • Jeon, Byung-Jin;Han, Kun-Hee;Shin, Seung-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.7
    • /
    • pp.9-16
    • /
    • 2018
  • The purpose of this study is to prevent the malicious user from breaking the door-lock due to physical impact. If it matches the analog displacement value set in the door-lock system, it protects the body and property by transmitting damage information in real time to the manager smart phone. The research suggests a system that transmits damage information in real time to registered users when door-lock is damaged by physical impact. Then compare the impact information sensed by the door lock with the data of the sensitivity control unit. In the web server of the proposed system, after impact information transmitted from Door-Lock is stored in the DB, if the impact information is larger than the shock detection transmission reference value stored in the DB, it is transmitted to the administrator in real time by SMS module so that illegal access information.

A study on the design and cooling of the heat sink with hybrid structure of conductive polymer composite and metal (열전도성 고분자 복합소재/금속 소재 하이브리드 구조의 방열기구 설계 및 방열특성에 관한 연구)

  • Yoo, Yeong-Eun;Kim, Duck Jong;Yoon, Jae Sung;Park, Si-Hwan
    • Design & Manufacturing
    • /
    • v.10 no.3
    • /
    • pp.14-19
    • /
    • 2016
  • Thermally or electrically conductive filler reinforced polymer composites are extensively being developed as the demand for light weight material increases rapidly in industiral applications need good conductivity such as heat sink of the electronics or light. Carbon or ceramic materials like graphite, carbon nanotube or boron nitride are typical conductive fillers with good thermal or electical conductivity. Using these conductive fillers, the polymer composites in the market show wide range of thermal conductivity from approximately 1 W/mK to 20 W/mK, which is quite enhanced considering the thermal conductivity lower than 0.5 W/mK for most polymeric materials. The practical use of these composites, however, is yet limited to specific applications because most composites are still not conductive enough or too difficult to process, too brittle, too expensive for higher conductivity. For practical use of conductive composite, the thermal conductivity required depending on the heat releasing mode are studied first for simplified unit cooling geometry to propose thermal conductivities of the composites for reasonable cooling performance comparing with the metal heat sink as a reference. Also, as a practical design for heat sink based on polymer composite, composite and metal sheet hybrid structures are investigated for LED lamp heat sink and audio amplication module housing to find that this hybrid structure can be a good solution considering all of the cooling performance, manufacturing, mechanical performance, cost and weight.

Filtration Performance in MSBR (Membrane-Coupled Sequencing Batch Reactor) using a Membrane for Both Filtration and Aeration (막결합형 연속회분식 생물반응조에서 여과 및 공기공급용으로 분리막을 사용할 때 공기공급이 막여과 성능에 미치는 영향)

  • Ryu, Kwan-Young;Park, Pyung-Kyu;Lee, Chung-Hak
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.337-346
    • /
    • 2005
  • An MSBR using a membrane for not only filtration but also aeration (MA-MSBR) was designed to reduce membrane fouling and to enhance water quality, and compared with an MSBR using a membrane for only filtration (BA-MSBR). COD removal efficiency of the MA-MSBR was similar to that of the BA-MSBR, but membrane performance of the MA-MSBR was better than that of the BA-MSBR. The MA-MSBR had more small particles in mixed liquor, so the specific cake resistance of flocs in the MA-MSBR was higher than that in the BA-MSBR. However, in the aerobic reaction step of the MA-MSBR, air went through membrane pores and out of the membrane surface, so cake layers on the membrane surface and a portion of organics adsorbed on membrane pores could be removed periodically. Therefore, cake resistance, $R_c$, and fouling resistance by adsorption and blocking, $R_f$, for the MA-MSBR increased more slowly than those for the BA-MSBR. Additionally, in order to compare the energy efficiency for two MSBRs, oxygen transfer efficiency and power to supply air into the reactor by a membrane module and a bubble stone diffuser were measured using deionized water. From these measurements, the transferred oxygen amount per unit energy was calculated, resulting that of MA-MSBR was slightly higher than that of BA-MSBR.