• 제목/요약/키워드: uninterruptible power supply (UPS)

검색결과 174건 처리시간 0.073초

비상전원 기능을 갖는 하이브리드 ESS를 위한 PCS 제어전략 (A PCS Control Strategy for Hybrid ESS with Function of Emergency Power Supply)

  • 김상진;권민호;최세완;백석민;김미성
    • 전력전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.302-311
    • /
    • 2016
  • This paper proposes a hybrid ESS that integrates an energy storage system (ESS) with an uninterruptible power supply (UPS). The hybrid ESS has a demand management and emergency power supply function while increasing the battery utilization of the UPS, which has just been used in a power failure. In addition to the critical load, the proposed system augments the capacity of emergency generation using an additional load, which has voltage and frequency-dependent characteristics to the grid side. The control algorithm of the AC-DC converter and bidirectional DC-DC converter is proposed for demand management and emergency power supply. Furthermore, seamless and autonomous transfer methods to alleviate the transient during mode transfer are proposed. To validate the proposed control scheme, experimental results from a 5 kW prototype are provided.

다중-레퍼런스/다중-출력 FXLMS 알고리즘에 의한 UPS 팬 소음저감 특성해석 (Characteristin Analysis of UPS Fan Noise Reduction by Multiple-Referedce/Multiple-Output FXLMS Algorithm)

  • 이승요;조준석;최규하
    • 전력전자학회논문지
    • /
    • 제4권6호
    • /
    • pp.589-600
    • /
    • 1999
  • 사무실에서 사용되는 소용량 무정전진원 장치(UPS : Uninterruptible Power Supply)는 대부분의 소음이 냉각팬을 통하여 발생되고 있는데, 이와 같이 장치의 여러 방향으로 방사되는 소음의 능동적 소음제어를 위해서는 FXLMS(Filtered-x LMS) 알고리즘에 기초를 둔 다중채널 방식의 FXLMS(multiple-channel FXLMS) 알고리즘의 사용이 적당하다. 본 논문에서는 사무실에서 주로 사용되는 소용량 UPS의 소음 발생 특성을 분석하고 다중채널 방식 MRMO(Multiple-Reference/Multiple-Output) FXLMS 알고리즘을 적용하여 방사상으로 전파되는 UPS의 소음을 저감시키기 위한 능동 소음 제어를 수행하고 이의 소음저감 특성을 고찰한다.

  • PDF

UPS를 내장한 컴퓨터용 SMPS (The SMPS with a Bulit-in UPS for Computer)

  • 이성룡;전칠환;이수원;고성훈;권혁대
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권8호
    • /
    • pp.495-499
    • /
    • 2004
  • UPS(Uninterruptible Power Supply) have been used to improve power source quality as well as to protect critical loads such as computer, industrial system, medical equipment, etc, by providing clean and uninterrupted power under power supply disturbance or interruptions. But UPS is bulky because batteries. So, a UPS size issue has received the attention in the power electronics industry. This paper proposed an implementation of the computer power supply with a bulit-in UPS controlled by the one-chip microprocessor to minimize UPS size. The experimental results verified the proposed SMPS with a bulit-in UPS for computer.

교통신호제어기용 무정전전원장치 용량기준 연구 (A Study on Standardization of UPS (Uninterruptible Power Supply) for Traffic Signal Controller)

  • 고광용;이철기;김민성;허낙원;정준하
    • 한국ITS학회 논문지
    • /
    • 제11권5호
    • /
    • pp.1-6
    • /
    • 2012
  • 현대의 도시교차로는 과거와 달리 날로 이용량과 시설규모가 증가하여 대형화하고 있다. 이에 따라 지역적 정전이나 광역적 정전사태가 발생하는 경우 교통상황은 걷잡을 수 없는 혼잡상황에 직면하게 된다. 최근에는 전력수요예측 오류로 인한 대규모 도시정전사태가 발생한 사례가 있으며, 이로 인한 교통 혼잡해소에 많은 시간과 비용이 소모된 바 있다. 이에 정부와 경찰청에서는 교통신호시스템의 비상대응력을 고도화하기 위해 무정전전원장치(UPS: Uninterruptible Power Supply)의 도입을 추진 중에 있다. 본 연구에서는 교통신호기의 제어 용량을 고려하여 최소 2시간 지속가능한 전원보상용량을 산정하고, 산정 용량을 기준으로 개발된 규격은 시제품 실험을 통하여 전원보상 요구 성능을 검증하였다. 실험결과 개발된 규격은 충분히 요구 성능을 만족하였으며 중요교차로 등 대형교차로에서 운영 가능한 것으로 나타났다.

무정전전원장치 병렬운전을 위한 인버터의 출력 위상 동기화 방법 (Output Phase Synchronization Method of Inverter for Parallel Operation of Uninterruptible Power System)

  • 김희주;박종면;오세형
    • 전력전자학회논문지
    • /
    • 제25권3호
    • /
    • pp.235-241
    • /
    • 2020
  • In this paper, we propose the bus/bypass synchronization phase lock loop (B-Sync PLL) method using each phase voltage controller of a parallel UPS inverter. The B-Sync PLL included in each phase voltage control system of parallel UPS inverters has the transient response and the phase synchronization error at grid normal or blackout. The validity of this method is verified by simulation and experiment. As a result, the parallel UPS inverters using the proposed method confirmed that the output phase was continuously synchronized when a grid blackout, improving the transient response characteristics for stable load power supply and equal load sharing.

UPS의 이해

  • 이승태
    • 제품안전
    • /
    • 통권91호
    • /
    • pp.64-65
    • /
    • 2001
  • UPS(Uninterruptible Power Supply)는 우리말로는 무정전전원장치(無停電電源裝置)라고 하는데, 정전(停電 : Stoppage of Electric Current)과 같은 전원장애(電源障碍)가 발생한 경우 UPS에 접속되어 잇는 기기에 지속적으로 전원을 공급하는 장치를 말한다. UPS방식에는 상시 인버터방식, 상시 상용방식, 라인 인터랙티브방식의 세가지가 있다.

  • PDF

공동주택용 하이브리드 무정전전원장치 (Hybrid Uninterruptible Power Supply for Apartment Housing)

  • 임승범;이원일;김명수;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.530-531
    • /
    • 2015
  • 본 논문에서는 공동주택용 하이브리드 무정전전원장치(UPS: Uninterruptible Power Supply)를 제안한다. 제안한 하이브리드 UPS는 기존의 UPS 시스템에 DC/DC 컨버터를 추가하여 태양광 패널과 연결 가능하여 기존의 태양광 PCS(Power Conditioning Supply)의 기능을 할 수 있다. 또한 정류기를 양방향으로 동작시켜 피크 부하시나 전력 부족시 전력을 전원단으로 회생시킬 수 있어 기존의 ESS(Energy Storage System) PCS 기능도 할 수 있다.

  • PDF

스위칭 소자에 의한 UPS의 특징 (The characteristic of UPS by Switching Element)

  • 강용철;차인수;이경섭;박해암;이우선
    • 한국통신학회:학술대회논문집
    • /
    • 한국통신학회 1991년도 추계종합학술발표회논문집
    • /
    • pp.220-224
    • /
    • 1991
  • Uninterruptible Power Supply(UPS) Systems are widely used in a varietyof fields as highly reliable power sources. This paper describes the operation and performance of an UPS using sinusoidal Pulse Width Modulation (PWM)techniques. A newly developed UPS adopted switching element -power TR, power MOSFET, IGBT- is introduced. Experimental results showed that sinusoidal PWM techniques have good features for UPS systems.

상용2회선 수전방식을 적용한 무정전 수변전설비 구축방안 검토·제안연구 (Construction of Uninterruptible Power System by Reliable Incoming Dual-Power Line)

  • 최진성;이상중
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.64-70
    • /
    • 2010
  • High capacity UPS and emergency generators are commonly employed at facilities where power interruption is not allowed. Nowadays, combinations of existing commercial incoming power and an emergency generator or combination of multiple generators and CTTS(Closed Transition Transfer Switch) is adopted sometimes for more reliable power supply. In this paper, application of CTTS and STS(Static Transfer Switch) to dual-power line is suggested for highly reliable uninterruptible power. By realizing such a system, construction of incoming power facilities, installation of emergency generator and large capacity UPS can be omitted, through which saving of the installation space and corresponding capital investment can be expected.

IGBT를 이용한 다기능 무정전전원 공급장치 (UPS)개발 (DEVELOPMENT OF MULTI-FUNCTIONAL UNINTERRUPTIBLE POWER SUPPLY USING INSULATED GATE BIPOLAR TRANSISTORS)

  • 김동욱;신현주;김연풍;백병산;류승표;민병권;최상덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.573-575
    • /
    • 1994
  • Resent research activities and technical trends for UPS(UNINTERRUPTIBLE POWER SUPPLY) are reviewed. There are increasing demands for UPS to get mote useful performance. This needs are high-efficiency, high-confidency, high-quality, low-cost. self-diagnosis. maintenance-free, and a wide variety of options. These can be satisfied with high-technology and optimal system coordination. In this paper. according to these demands. a newly developed UPS and a wide variety of options are introduced. Also. the data related are presented.

  • PDF