• Title/Summary/Keyword: underground development

Search Result 1,084, Processing Time 0.04 seconds

Construction Plan of 3D Cadastral Information System on Underground Space (지하공간 3차원 지적정보시스템 구축 방안 연구)

  • Song, Myungsoo;Lee, Sungho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.6
    • /
    • pp.57-65
    • /
    • 2014
  • Recently, Construction business is changing from on the ground to underground space because of deficit of developing space, creation of green space and of incremental of land compensation expenses. Meanwhile, 3D Topographic, Marine and Cadastral maps need to have Spatial Interrelation. Also, understanding of the information is also needed. Spatial information object registration system is impossible to contact and understanding intelligence mutually because the former one is managed as automatic ID system. Therefore, 3D Object information ID System of underground space is managed based on Object Identifier. Construction of Spatial information integration ID System is required and it will offer Division Code (Ground, Index, Underground) and depth information. We are defined and classified Under Spatial Information in this paper. Moreover, we developed the integration ID System based on UFID for cadastral information Construction. We supposed underground spatial information DB Construction and a developed the way of exploiting 3D cadastral information system through the study. The research result will be the base data of Standard ID system, DB Construction and system Development of National spatial data which is considered together with spatial interrelation.

Development of a Deep Learning-based Fire Extinguisher Object Detection Model in Underground Utility Tunnels (딥러닝 기반 지하 공동구 내 소화기 객체 탐지 모델 개발)

  • Sangmi Park;Changhee Hong;Seunghwa Park;Jaewook Lee;Jeongsoo Kim
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.4
    • /
    • pp.922-929
    • /
    • 2022
  • Purpose: The purpose of this paper is to develop a deep learning model to detect fire extinguishers in images taken from CCTVs in underground utility tunnels. Method: Various fire extinguisher images were collected for detection of fire extinguishers in the running-based underground utility tunnel, and a model applying the One-stage Detector method was developed based on the CNN algorithm. Result: The detection rate of fire extinguishers photographed within 10m through CCTV video in the underground common area is over 96%, showing excellent detection rate. However, it was confirmed that the fire extinguisher object detection rate drops sharply at a distance of 10m or more, in a state where it is difficult to see with the naked eye. Conclusion: This paper develops a model for detecting fire extinguisher objects in underground common areas, and the model shows high performance, and it is judged that it can be used for underground common area digital twin model synchronizing.

The Design of Underground Utilities Management System based on Mobile Augmented Reality Technology (모바일 증강현실 기술을 이용한 지하 사회 기반 시설 관리 시스템 설계)

  • Baek, Jang-Mi;Hong, In-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.1
    • /
    • pp.41-47
    • /
    • 2013
  • A great number of people all over the world are using smart phones. Researchers develop innovative technology of App. It's make rapid progress now that the country's infrastructure is computerized, we expect IT Technological Convergence. In this paper, designs underground utilities management system based on mobile augmented reality technology, and architecture configuration, interface development. Proposal system minimizes overhead of smart devices belonging to engineer's representative using wireless personal area networks. Center Server technology manages transmitted data from engineer's representative, it monitors client data path. And it provies information processing capacity for event generation module. Such event has connotations of instability and uncertainty.

The Development of sub-event Information interface for Integrated management of underground pipelines (통합 서비스를 위한 지하매설관 하부 이벤트 정보전달 인터페이스 개발)

  • Chae, Sookwon;Seo, Jaesoon;Kim, Joonseok
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.1
    • /
    • pp.26-34
    • /
    • 2017
  • In this study, for the integrated information management of underground pipelines, each information management server software must have it's inter-operability. So Many kinds of smart-city integrated platform softwares were surveyed and the best platform software was selected. The interface software modules developed in this study was installed at the test system. Through this test system, when a sub system transfers an event message to the upper integrated server system, the inter-operability test between the upper system and a sub operating system was performed and its operability was resolved.

Characteristics of Structural Behavior of Unplasticized Polyvinyl Chloride (PVC-U) Pipe Buried Underground (지중매설 경질폴리염화비닐관의 구조적 거동)

  • Kim, Sun-Hee;Cheon, Jinuk;Kim, Eung-Ho
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.4
    • /
    • pp.16-23
    • /
    • 2015
  • The industrialization and urbanization forced to increase the density of pipelines such as water supply, sewers, and gas pipelines. The materials used for the existing pipe lines are mostly composed of concretes and steels, but it is true that the development for more durable and efficient materials has been continued performed to produce long lasting pipe lines. Recently, underground pipes serve in diverse applications such as sewer lines, drain lines, water mains, gas lines, telephone and electrical conduits, culverts, oil lines, etc. In this paper, we present the result of investigation pertaining to the structural behavior of unplasticized polyvinyl chloride (PVC-U) flexible pipes buried underground. In the investigation of structural behavior such as a ring deflection, pipe stiffness, 4-point bending test, experimental and analytical studies are conducted. In addition, pipe stiffness is determined by the parallel plate loading tests and the finite element analysis. The difference between test and analysis is about 8% although there are significant variations in the mechanical properties of the pipe material. In addition, it was found by the 4-point bending test there is no problem in the connection between the pipes by coupler.

Database Development Guideline for the Effective Management of Underground Facilities in Seoul (GIS를 이용한 지하매설물의 효율적 관리방안 : 데이터베이스 설계 및 구축방안을 중심으로)

  • 강영옥;조태영
    • Spatial Information Research
    • /
    • v.5 no.1
    • /
    • pp.115-131
    • /
    • 1997
  • Effective management of underground facilities which include water line, sewer line, electric line, telephone line, gas line etc., is very important for people's safety as well as administrative efficiency. The purpose of this study is four-fold: first, investigate management status of utility information of each utility companies, second, develope classification system of underground facilities and use this classification system for guidelines of database construction and for the exchange of database among utility companies, third, construct database using existing utility maps in pilot study area and identify accuracy of the existing maps and suggest strategy of database construction, fourth, suggest strategy of database maintenance and its organizational plan in connection with national plan.

  • PDF

Evolution of sandstone shear strength parameters and its mesoscopic mechanism

  • Shi, Hao;Zhang, Houquan;Song, Lei
    • Geomechanics and Engineering
    • /
    • v.20 no.1
    • /
    • pp.29-41
    • /
    • 2020
  • It is extremely important to obtain rock strength parameters for geological engineering. In this paper, the evolution of sandstone cohesion and internal friction angle with plastic shear strain was obtained by simulating the cyclic loading and unloading tests under different confining pressures using Particle Flow Code software. By which and combined with the micro-crack propagation process, the mesoscopic mechanism of parameter evolution was studied. The results show that with the increase of plastic shear strain, the sandstone cohesion decreases first and then tends to be stable, while the internal friction angle increases first, then decreases, and finally maintains unchanged. The evolution of sandstone shear strength parameters is closely related to the whole process of crack formation, propagation and coalescence. When the internal micro-cracks are less and distributed randomly and dispersedly, and the rock shear strength parameters (cohesion, internal friction angle) are considered to have not been fully mobilized. As the directional development of the internal micro-fractures as well as the gradual formation of macroscopic shear plane, the rock cohesion reduces continuously and the internal friction angle is in the rise stage. As the formation of the macroscopic shear plane, both the rock cohesion and internal friction angle continuously decrease to a certain residual level.

Development of Inspection and Diagnosis System for Safety and Maintenance in Tunnel (터널 유지관리를 위한 안전진단시스템 개발에 관한 연구)

  • Kim, Young-Geun;Baek, Ki-Hyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.3 no.1
    • /
    • pp.37-50
    • /
    • 2001
  • Recently, as tunnel structure is getting old, many deformations and defects have been occurred. As tunnel has the characteristics of underground structure, the estimation of the cause of deformation is very difficult. Then, it is necessary to investigate the state of tunnel lining and to estimate the deformation cause and safety for tunnel. In this study, inspection and diagnosis system for effective maintenance in tunnel was researched. Firstly, non-destructive techniques such as GPR (ground penetrating radar), impact echo test, and infrared thermal techniques were applied to tunnel lining inspection. Tunnel lining analysis system was developed to analyze the stability of tunnel. And, tunnel soundness evaluation system was developed to find the probable causes and indicate the method for repair and reinforcement for tunnel.

  • PDF

The Development of Effective Database Model for Pipe Network Management Monitoring Program (상수도 관망시스템의 유지관리용 모니터링 프로그램을 위한 효율적 D/B 모델의 개발)

  • Kang, Byung-Mo;Lee, Hyun-Dong;Hong, In-Sik
    • Journal of Internet Computing and Services
    • /
    • v.9 no.4
    • /
    • pp.157-166
    • /
    • 2008
  • There has been a renewal of interest in management of underground facility in recent years. As several research have been made on management for underground facility of waterworks pipe. In this paper smart-tag is defined and applied to requiring ubiquitous environment. Also, GPS is essential technology for the implementation of proposed program, which has GPS and RFID mixed business model. And it manages data of underground facility with RFID system effectively and provides the high quality practical effectiveness of entire system through GPS receiving module and network communication on GIS. In conclusion, this paper proposed applications management system with location mixed database. Proposed database and interface skill is tested and evaluated through the simulation.

  • PDF

An Analysis of the Fire Load and Ventilation Factor in Underground Commercial Space (지하상업공간의 환기계수 및 화재하중 분석)

  • Choo Yeun-Hee;Lee Ji-Hee;Hong Won-Hwa
    • Journal of the Korean housing association
    • /
    • v.17 no.2
    • /
    • pp.135-142
    • /
    • 2006
  • The purpose of this study is to obtain the fire safety for underground commercial space with analysing fire loads and ventilation factors. It was adopted the investigation method of field survey with commercial uses for more confidential data. The results of this study can be summarized as follows; 1) The ventilation factor shows $0.04{\sim}0.24m^{1/2}$ and it may develop ventilation-controlled fires which have much fire hazard more than fuel-controlled fires. 2) The highest value of fire load is $158.48kg/m^2$ and appeared in footwear shop which has the value $137.35kg/m^2$ for unfixed combustibles and $21.13kg/m^2$ for fixed combustibles. 3) The average value of burning rates which mean the velocity of fire development and the fire damage range is 0.143. Therefore it is desired to decrease the combustibles of compartment and is needed the method of dispersion arrangement of goods and storage to steel cabinet and so on.