• 제목/요약/키워드: unbonded area

검색결과 14건 처리시간 0.024초

일반 가설앵커의 문제점과 개선방향 (Ground Anchor Testing on Temporary Excavations)

  • 김성규;김낙경;김정렬
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.545-552
    • /
    • 2003
  • For temporary excavation support in a congested urban area, the strand of ground anchor should be removed to get permission of the private land to install anchors. But the strand doesn't need to be removed in the outside city area after use. So the anchor body, tension anchor, is fabricated in-situ. The unbonded length of This anchor has several strands, which wrap only one sheath. When the anchor body is carried into job-site or installed in the bore hole, the sheath is torn easily because it is a very week material. So the grout permeate into the torn sheath. Because of that, the load doesn't transfer to the bond length of ground anchors. It may indicate that load is being transferred along the unbonded length and thus within the potential slip surface assumed for overall stability of the anchored system. The load tests were performed on seven low-pressure grouted anchors installed in weathered soil to verify its problems. Four anchors(Type A) have the unbonded length, which consist of five strands and a week sheath and three anchors(Type B) have strands, which is covered by plastic sheath filled with grease, in the unbonded length. Both anchors are compared with load tests results.

  • PDF

Optimum seismic design of unbonded post-tensioned precast concrete walls using ANN

  • Abdalla, Jamal A.;Saqan, Elias I.;Hawileh, Rami A.
    • Computers and Concrete
    • /
    • 제13권4호
    • /
    • pp.547-567
    • /
    • 2014
  • Precast Seismic Structural Systems (PRESSS) provided an iterative procedure for obtaining optimum design of unbonded post-tensioned coupled precast concrete wall systems. Although PRESSS procedure is effective, however, it is lengthy and laborious. The purpose of this research is to employ Artificial Neural Network (ANN) to predict the optimum design parameters for such wall systems while avoiding the demanding iterative process. The developed ANN model is very accurate in predicting the nondimensional optimum design parameters related to post-tensioning reinforcement area, yield force of shear connectors and ratio of moment resisted by shear connectors to the design moment. The Mean Absolute Percent Error (MAPE) for the test data for these design parameters is around %1 and the correlation coefficient is almost equal to 1.0. The developed ANN model is then used to study the effect of different design parameters on wall behavior. It is observed that the design moment and the concrete strength have the most influence on the wall behavior as compared to other parameters. Several design examples were presented to demonstrate the accuracy and effectiveness of the ANN model.

강선량 및 긴장력에 따른 외부 강선을 가진 PSC 보의 휨거동 실험 (Experiment of Flexural Behavior of Prestressed Concrete Beams with External Tendons according to Tendon Area and Tendon Force)

  • 유성원;양인환;서정인
    • 콘크리트학회논문집
    • /
    • 제21권4호
    • /
    • pp.513-521
    • /
    • 2009
  • 최근 들어 외부 강선을 이용한 프리스트레스트 콘크리트구조물의 건설이 증가하고 있다. 그러나 극한거동 해석시 단면 적합조건을 이용하는 내부 부착 강선과는 다르게 외적 비부착 강선은 부재의 전체거동에 의해서 응력 증 가량이 결정된다. 또한 편향부에서의 미끌림 효과와 강선의 편심 변화 효과 등이 발생하게 된다. 따라서 본 연구는 외 부 강선을 가지는 프리스트레스트 콘크리트(PSC) 보의 거동 특성을 평가하기 위하여 강선량, 긴장력 등을 변수로 하여 정적 휨실험을 수행하여 외부 강선 부재의 휨거동 특성을 얻었다. 실험 결과에 의하면 균열발생 이전의 외부 강선 PSC 부재는 부착 강선 PSC부재와 거동 차이가 크지 않음을 알 수 있었다. 그러나 균열이 발생한 이후의 거동에서는 철근의 항복하중, 극한하중, 강선 응력 등이 외부 강선 부재에서의 값이 부착 강선 부재에 비해서 작게 나타나고 있다. 하중-강 선 변형률 관계에서 보면, 외부 강선 부재들의 경우, 하중 증가에 따른 외부 강선 변형률의 증가량은 초기 긴장력의 크 기 순서와 거의 반대의 순서로 외부 강선의 변형률이 증가한 것으로 나타났으나, 다만 초기 긴장력이 크다할지라도 강 선의 유효응력이 작은 경우의 강선 변형률은 강선의 유효응력이 큰 부재들보다는 다소 작게 증가하고 있는 것으로 나 타났다. 외부 강선 부재의 콘크리트에 발생된 압축 변형률의 크기는 외부 강선의 유효응력 크기 순서와 일치하는 것으 로 나타나, 콘크리트의 압축변형률은 외부 강선의 유효응력에 비례함을 알 수 있다. 실험 결과와 기존의 설계식과 비교 해본 결과, ACI-318에 의한 결과는 긴장력 혹은 유효응력이 차이를 전혀 반영하지 못하고 있고 특히, 그 결과가 실험 결과보다 상당히 작게 나타나, 지나치게 보수적인 것으로 판단된다. 한편 AASHTO 1994는 ACI-318과는 다르게 강선량, 초 기 힘 및 유효응력 등의 변화에 적절하게 영향을 받고 있는 것으로 나타났지만 내부 비부착 강선의 실험 결과를 이용 하여 작성된 이유로 외부 강선 실험 결과보다 지나치게 큰 결과를 유발하고 있는 것으로 평가된다. 이러한 이유로 외 부 강선의 극한응력을 정확하게 예측할 수 있는 새로운 규정이 필요하다.

Numerical assessment of post-tensioned slab-edge column connection systems with and without shear cap

  • Janghorban, Farshad;Hoseini, Abdollah
    • Computers and Concrete
    • /
    • 제22권1호
    • /
    • pp.71-81
    • /
    • 2018
  • Introduction of prestressed concrete slabs based on post-tensioned (PT) method aids in constructing larger spans, more useful floor height, and reduces the total weight of the building. In the present paper, for the first time, simulation of 32 two-way PT slab-edge column connections is performed and verified by some existing experimental results which show good consistency. Finite element method is used to assess the performance of bonded and unbonded slab-column connections and the impact of different parameters on these connections. Parameters such as strand bonding conditions, presence or absence of a shear cap in the area of slab-column connection and the changes of concrete compressive strength are implied in the modeling. The results indicate that the addition of a shear cap increases the flexural capacity, further increases the shear strength and converts the failure mode of connections from shear rigidity to flexural ductility. Besides, the reduction of concrete compressive strength decreases the flexural capacity, further reduces the shear strength of connections and converts the failure mode of connections from flexural ductility to shear rigidity. Comparing the effect of high concrete compressive strengths versus the addition of a shear cap, shows that the latter increases the shear capacity more significantly.

Experimental Cyclic Behavior of Precast Hybrid Beam-Column Connections with Welded Components

  • Girgin, Sadik Can;Misir, Ibrahim Serkan;Kahraman, Serap
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권2호
    • /
    • pp.229-245
    • /
    • 2017
  • Post-earthquake observations revealed that seismic performance of beam-column connections in precast concrete structures affect the overall response extensively. Seismic design of precast reinforced concrete structures requires improved beam-column connections to transfer reversed load effects between structural elements. In Turkey, hybrid beam-column connections with welded components have been applied extensively in precast concrete industry for decades. Beam bottom longitudinal rebars are welded to beam end plates while top longitudinal rebars are placed to designated gaps in joint panels before casting of topping concrete in this type of connections. The paper presents the major findings of an experimental test programme including one monolithic and five precast hybrid half scale specimens representing interior beam-column connections of a moment frame of high ductility level. The required welding area between beam bottom longitudinal rebars and beam-end plates were calculated based on welding coefficients considered as a test parameter. It is observed that the maximum strain developed in the beam bottom flexural reinforcement plays an important role in the overall behavior of the connections. Two additional specimens which include unbonded lengths on the longitudinal rebars to reduce that strain demands were also tested. Strength, stiffness and energy dissipation characteristics of test specimens were investigated with respect to test variables. Seismic performances of test specimens were evaluated by obtaining damage indices.

고장력 인장봉으로 보강된 RC 보의 휨 거동에 관한 실험적 연구(3) (An Experimental Study on Flexural Behavior of RC Beams Strengthened with Hi-Strength Bars(3))

  • 신경재;김윤정;문정호
    • 콘크리트학회논문집
    • /
    • 제19권3호
    • /
    • pp.351-358
    • /
    • 2007
  • 현재 상용되고 있는 강판 보강법이나 탄소섬유 시트 부착 보강법과는 달리, 고장력 인장봉을 이용한 외부 비부착 방식의 보강법은 설치가 간단하고 시공 시간이 짧은 등의 장점이 있다. 또한 외부 비부착 보강법은 콘크리트 표면처리가 필요 없고 에폭시 등의 접착제를 사용하지 않아 환경에 미치는 영향도 적다. 지난 연구에 이어 본 연구에서는 보강된 RC보에 관한 총 9개의 실대형 시험체를 변수별로 제작하여 여러 변수가 실제 구조물에 미치는 영향을 검토하였다. 시험체의 주요 변수는 보강재의 크기와 전단 보강근의 간격, 지지 조건이다. 본 논문에서는 보강된 RC 보의 구조적 거동을 무보강 시험체와 비교하여 기술하였다. 실험 결과 고장력 인장봉으로 보강된 RC보는 무보강 시험체와 비교하여 강도와 휨 성능에서 탁월한 효과를 나타내었으며 전단 보강근이 과소 배근된 시험체에서도 고장력 인장봉에 의한 전단 내력 효과를 보였다.

액체금속로 핵연료봉의 초음파 산란 해석 (Analysis of ultrasonic scattering from nuclear fuel pins of liquid metal reactor)

  • 주영상
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1998년도 학술발표대회 논문집 제17권 2호
    • /
    • pp.247-250
    • /
    • 1998
  • The scattering of plane ultrasonic waves by the nuclear fuel pin of liquid metal reactor in sodium is studied. According to the internal composition in the cladding tube, the fuel pin has three cross sections, i.e. helium gas plenum, sodium-filled section, and fuel insertion section. The scattering spectra for each section of the fuel pin are different. The circumnavigating ultrasonic waves of each section are analyzed by the resonance scattering method. The whispering gallery wave modes are generated in the sodium-filled plenum section and the fuel rod insertion section with a sodium-gap. The circumferential wave modes are propagated in the cladding tube of the helium gas plenum section. The annular gap between the cladding tube and metal uranium pellet rod affects the scattering spectra. The different propagation characteristics can be utilized for the nondestructive method of detecting the unbonded area and measuring the level of the sodium-filled section of the fuel pin.

  • PDF

knee brace가 설치된 구조물의 내진설계 (Seismic Design of Structures with Knee Braces)

  • 김진구;서영일
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.274-281
    • /
    • 2002
  • In this study a analytical model for a structure with buckling-restrained unbonded knee-braces is proposed, and a performance-based seismic design procedure for such a system Is provided. The proposed structure system has advantage of simplifying the structural design procedure in that the hinge-connected main structural members, such as beams and columns, are designed only for gravity loads, and all the lateral seismic load is resisted by the braces. The design procedure is based on the concept of equivalent damping, and is implemented to the capacity spectrum method. Parametric study is performed with design variables such as yield stress and cross-sectional area of knee-braces to find out proper slope of the braces.

  • PDF

고장력 인장봉으로 보강된 RC보의 휨거동에 관한 실험적 연구 (An Experimental Study on the Flexural Behavior of RC Beams Strengthened with Hi-Strength Bars)

  • 김윤정;신경재;문정호;오영석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.193-196
    • /
    • 2006
  • Unlike external bonded plate or carbon fiber, the external unbonded strengthening has some advantages in speed and simplicity of installation. It is not required surface preparations and not affected by environmental conditions. A set of six laboratory tests on RC beams strengthened using the technique are reported, results compared with non-strengthened specimens. The main test parameters are the cross-sectional area of the high-tension bar and the distance of stirrups. Test result show that the beams reinforced are superior to reference specimens, especially for the strength and deformation capacity. Also, it is shown that good efficiencies can be achived in shear strength of the beam.

  • PDF

선형열처리법으로 직접 접합된 Si 기판 및 산화된 Si 기판의 접합 특성 (Bonding Characteristics of Directly Bonded Si wafer and Oxidized Si wafer by using Linear Annealing Method)

  • 이진우;강춘식;송오성;류지호
    • 한국재료학회지
    • /
    • 제10권10호
    • /
    • pp.665-670
    • /
    • 2000
  • 실온에서 직접 접합된 실리콘 기판의 접합강도를 향상기키기 위하여 기존의 고온 로내 열처리법을 대체할 수 있는 선형 열처리법을 개발하였다. 한 개의 열원과 타원형 반사경으로 구성된 선형 열처리법은 접합면의 간격이 열처리 온도의 증가와 더불어 감소하는 특성과 온도 증가와 더불어 접합면에 생성된는 기체상의 밀도가 증가하는 현상을 응용하여 접합면의 기체상을 밀도차이를 이용하여 기판 외부로 방출시키는 방법으로 Si$\mid$$\mid$Si 기판쌍 및 Si$\mid$$\mid$$SiO_2/Si$ 기판쌍의 직접 접합에 적용하여 보았다. IR camera와 HRTEM으로 직접 관찰한 접합면은 실온에서 접합면에 침투한 외부 불순물에 의한 비접합 영역을 제외하고는 자제 생성된 기체상에 의한 비접합 영역은 나타나지 않았고 매우 깨끗한 접합계면을 나타내었다. 접합된 기판쌍을 Crack opening법과 인장시험법을 적용하여 접합 강도를 측정하였다. 접합 강도는 열처리 온도의 증가와 더불어 점차로 증가하였고 두 측정방법 모두 동일한 경향성을 나타내었다.

  • PDF