• 제목/요약/키워드: ultrasound measurement

검색결과 328건 처리시간 0.022초

이중 반응기 조건 및 비균일계 조건에서의 초음파 에너지 및 화학적 효과 평가 (Estimation of Ultrasonic Energy and Sonochemical Effects in Double-Bath-Type Systems and Heterogeneous Systems)

  • 이현재;손영규
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권5호
    • /
    • pp.40-47
    • /
    • 2017
  • The effects of ultrasound in heterogeneous system were investigated in three kinds of ultrasonic systems including a bath-type system (System #1), a double-bath-type system (System #2), and a double-bath-type system partly filled with glass beads (System #3). The ultrasound energy and its attenuation were quantified using calorimetry and the sound pressure measurement method. The sonochemical effects mainly involved in radical oxidation reactions were quantified using KI dosimetry. It was found that ultrasound energy was significantly attenuated in System #2 and #3 due to the presence of solid materials such as a submerged stainless steel reactor and glass beads. However, in spite of low ultrasound energy status, sonochemical oxidation reactions occurred more violently due to the presence of glass beads in System #3. In addition, calorimetry was more adequate to estimate the total energy status of ultrasound in sonoreactors compared to the sound pressure measurement method.

정상 골격근의 근전도 중앙주파수 및 초음파 영상 밀도 분석 (Analysis of sEMG Median frequency and Ultrasound Image Echodensity of Normal Skeletal Muscle)

  • 정진규;김용남;황태연;이정우;김태열
    • The Journal of Korean Physical Therapy
    • /
    • 제18권1호
    • /
    • pp.83-94
    • /
    • 2006
  • Purpose: This study conducts quantitative evaluation or structural and functional characteristics or normal skeletal muscle with ultrasound image and surface electromyography, and is to provide basic materials for utilizing ultrasound image analysis in physical therapy diagnosis and assessment of skeletal muscle. Methods: Measurement of three stages was conducted with 88 normal adults between their twenties and seventies, correlations and differences using collected data according to age and gender were compared and correlations among measured items were analyzed and then the following conclusions were obtained. Results: Analysis of ultrasound image of normal skeletal muscle showed that density, median frequency had the closest relations with age. In addition, it was found that there were high correlations between density explaining structural characteristics of skeletal muscle and median frequency explaining functional characteristics. Conclusion: Analysis of ultrasound image makes complex evaluation of structure and function of skeletal muscle possible when it is connected with functional evaluation method using physical measurement surface electromyography as well as quantitative evaluation of structural changes of skeletal muscle and is effective in complementing physical therapy diagnosis centering around functionality evaluation.

  • PDF

초음파 영상 분석을 위한 3D 프린팅 기반 미세유체소자 (Microfluidic Device for Ultrasound Image Analysis based on 3D Printing)

  • 강동국;홍현지;염은섭
    • 한국가시화정보학회지
    • /
    • 제16권1호
    • /
    • pp.15-20
    • /
    • 2018
  • For the measurement of biophysical properties related with cardiovascular diseases (CVD), various microfluidic devices were proposed. However, many devices were monitored by optical equipment. Ultrasound measurement to quantify the biophysical properties can provide new insights to understand the cardiovascular diseases. This study aims to check feasibility of microfluidic device for ultrasound image analysis based on 3D printer. To facilitate acoustic transmission, agarose solution is poured around 3D mold connected with holes of the acrylic box. By applying speckle image velocimetry(SIV) technique, flow information in the bifurcated channel was estimated. Considering that ultrasound signal amplitude is determined by red blood cell (RBC) aggregation, RBC aggregation in the bifurcated channel can be estimated through the analysis of ultrasound signal. As examples of microfluidic device which mimic the CVD model, velocity fields in microfluidic devices with stenosis and aneurysm were introduced.

Genetic Analysis of Ultrasound and Carcass Measurement Traits in a Regional Hanwoo Steer Population

  • Hwang, Jeong Mi;Cheong, Jae Kyoung;Kim, Sam Su;Jung, Bong Hwan;Koh, Myung Jae;Kim, Hyeong Cheol;Choy, Yun Ho
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제27권4호
    • /
    • pp.457-463
    • /
    • 2014
  • Ultrasound measurements of backfat thickness (UBF), longissimus muscle area (ULMA) and marbling score (UMS) and carcass measurements of carcass weight (CW), backfat thickness (BF), longissimus muscle area (LMA), and marbling score (MS) on 7,044 Hanwoo steers were analyzed to estimate genetic parameters. Data from Hanwoo steers that were raised, finished in Hoengseong-gun, Gangwon-do (province) and shipped to slaughter houses during the period from October 2010 to April 2013 were evaluated. Ultrasound measurements were taken at approximately three months before slaughter by an experienced operator using a B-mode real-time ultrasound device (HS-2000, FHK Co. Ltd., Tokyo, Japan) with a 3.5 MHz linear probe. Ultrasound scanning was on the left side between 13th rib and the first lumbar vertebrae. All slaughtering processes and carcass evaluations were performed in accordance with the guidelines of beef grading system of Korea. To estimate genetic parameters, multiple trait animal models were applied. Fixed effects included in the models were: the effects of farm, contemporary group effects (year-season at the time of ultrasound scanning in the models for UBF, ULMA, and UMS, and year-season at slaughter in the models for CW, BF, LMA, and MS), the effects of ultrasound technicians as class variables and the effects of the age in days at ultrasound scanning or at slaughtering as linear covariates, respectively for ultrasound and carcass measures. Heritability estimates obtained from our analyses were 0.37 for UBF, 0.13 for ULMA, 0.27 for UMS, 0.44 for CW, 0.33 for BF, 0.36 for LMA and 0.54 MS, respectively. Genetic correlations were strongly positive between corresponding traits of ultrasound and carcass measures. Genetic correlation coefficient between UBF and BF estimate was 0.938, between ULMA and LMA was 0.767 and between UMS and MS was 0.925. These results suggest that ultrasound measurement traits are genetically similar to carcass measurement traits.

초음파 조영제를 애용한 Echo PIV 기법의 개발 (Development of Echo PIV Using Ultrasound Contrast Agent)

  • 김형범
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1528-1534
    • /
    • 2004
  • The combination of ultrasound echo images with digital particle image velocimetry (DPIV) methods has resulted in a two-dimensional, two-component velocity field measurement technique appropriate for opaque flow conditions including blood flow in clinical applications. Advanced PIV processing algorithms including an iterative scheme and window offsetting were used to increase spatial resolution. The optimum concentration of the ultrasound contrast agent used for seeding was explored. Velocity validation tests in fully developed laminar pipe flow result of echo PIV showed good agreement with both optical PIV measurements and the known analytic solution based on a volume flow measurement.

에코 PIV: in vivo 유동 측정기법 (Echo-PIV: in vivo Flow Measurement Technique)

  • 김형범
    • 한국가시화정보학회지
    • /
    • 제3권1호
    • /
    • pp.26-35
    • /
    • 2005
  • The combination of ultrasound echo images with digital particle image velocimetry (DPIV) method has resulted in a two-dimensional, two-component velocity field measurement technique appropriate for opaque flow conditions including blood flow in clinical applications. Advanced PIV processing algorithms including an iterative scheme and window of offsetting were used to increase spatial resolution. The optimum concentration of the ultrasound contrast agent used for seeding was explored. Velocity validation tests in fully developed laminar pipe flow and pulsatile flow showed good agreement with both optical PIV measurements and the known analytic solution. These studies indicate that echo PIV is a promising technique for the non-invasive measurement of velocity profiles and shear stress.

  • PDF

초음파의 세포 단위 생체역학 (Cellular-level Biomechanics of Ultrasound)

  • 엄원석
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권1E호
    • /
    • pp.28-37
    • /
    • 2010
  • This article reviews recent developments in the emerging field of cellular-level biomedical ultrasonics with the specific focus on the mechanics of ultrasound-cell interaction. Due to the nature of the field at its relative infancy, the review poses more questions than it provides answers. Discussed are topics such as the basic structure of a biological cell, the origin of cell's elasticity, a theoretical framework for ultrasound-cell interaction, and shape deformation of cells and its measurement, Some interesting problems for future study are proposed.

상완혈 자침시 복부 장기의 안전성 확보를 위한 초음파시스템의 신뢰도 측정 (Reliability Measurement of the Ultrasound for Safety of the Abdominal Organs on Acupuncturing Sangwan (CV13))

  • 김지혜;백태현
    • 대한한의진단학회지
    • /
    • 제15권2호
    • /
    • pp.203-214
    • /
    • 2011
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with a ultrasound device with three methods of 3.5 MHz convex probe and gel, 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad, three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver were 9.20 (9 MHz linear probe and gel), 14.70 (9 MHz linear probe and solid gel pad). So we concluded that repeatabilities and reproducibilities of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with the methods of 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad were acceptable.

영상 분석 프로그램을 이용한 혈관 내 초음파 영상의 화질 측정 방법 고안 (Development of a Method for Measuring Image Quality of Intra Vascular Ultrasound Images using Image Analysis Program)

  • 서영현;한재복;송종남
    • 한국방사선학회논문지
    • /
    • 제15권5호
    • /
    • pp.621-628
    • /
    • 2021
  • 혈관 내 초음파 카테터의 주파수 관련 화질 분석에 대한 선행 연구는 국내 국외 모두 미비한 실정이다. 따라서 프로그램을 이용해 영상 화질 측정 방법의 기준을 마련하여 혈관 내 초음파 영상의 화질 분석 관련 연구자들에게 측정 방법을 제안하고자 본 연구를 진행하게 되었다. 대상으로는 혈관 내강 크기가 3.0 - 4.0 mm를 대상으로 혈관 내 초음파를 사용하기 전 초음파 카테터에 공기나 이물질이 들어가지 않도록 충분히 세척해주고 니트로글리세린(NTG)을 관상동맥 내 200 micro를 투여해 혈관을 충분히 확장시킨 영상의 정상 혈관 영상과 병변 혈관 영상을 대상으로 하였다. 기준이 되는 영상 획득 방법으로는 혈관 내 초음파 사용 시 혈관 병변 평가가 가장 우수한 심장 수축기 끝 구간의 영상을 DCAS PACS 프로그램을 통해 후향적으로 획득하여 기준을 설정하였다. 측정 방법 기준 설정 시 정상 혈관과 병변 혈관의 동심원적 및 편심원적에 해당하는 기준 설정 방법을 제안하였고 이 기준을 적용하여 정상 혈관과 병변 혈관의 내강과 외강 관심 영역 및 배경 영역 측정 방법에 대해 제안하였다. 결론적으로 본 연구자들이 고안해낸 방법을 통해 혈관 내 초음파 촬영 영상의 화질을 측정한다면 혈관 내 초음파 카테터의 종류를 불문하고 일관성 있는 화질 측정 진행이 가능하다 생각한다. 따라서 혈관 내 초음파 영상 화질 관련 연구 시 실제 화질 측정 방법에 대해 가이드라인으로 적용시킬 수 있을 것으로 사료된다.

Relationship between Body Condition Score and Ultrasonographic Measurement of Subcutaneous Fat in Dairy Cows

  • Zulu, Victor Chisha;Nakao, Toshihiko;Moriyoshi, Masaharu;Nakada, Ken;Sawamukai, Yutaka;Tanaka, Yoshinobu;Zhang, Wen-Chang
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제14권6호
    • /
    • pp.816-820
    • /
    • 2001
  • This study aimed at relating body condition score (BCS) to ultrasound measurements of subcutaneous fat over the areas most commonly used to BCS Holstein-Friesian cows, and determining the practicality of ultrasound measurement of subcutaneous fat for assessment of energy status of the cow. Twenty-eight cows were scored to the nearest quarter point on a scale of 1-5 (1=thin and 5=fat) using both visual and tactile techniques. On the same day, ultrasound measurements of subcutaneous fat were obtained at the lumbar transverse process, thurl and near the tailhead areas on both sides of the cow making six locations. Spearman's rank correlation coefficients between the six ultrasound locations ranged from 0.72-0.93 and were all significantly different from zero (p<0.01). Correlation coefficients between BCS and the mean lumbar, thurl and tailhead ultrasound measurements ranged between 0.67-0.72 and were also significantly different from zero (p<0.01). BCS was highly and significantly correlated to ultrasound measurements of subcutaneous fat. Ultrasound can be used independently or in conjunction with BCS to estimate the nutrition and energy status of cows.