Abstract
Prior studies on frequency-related image quality analysis of intravascular ultrasound catheters are lacking both in Korea and abroad. Therefore, this study was conducted to prepare a standard for measuring the image quality using the program and to suggest a measuring method to researchers related to the quality analysis of intravascular ultrasound images. For the target, the vessel lumen size is 3.0 - 4.0 mm. Before using intravascular ultrasound, thoroughly clean the ultrasound catheter so that no air or foreign substances enter it. Normal vascular images and lesion vascular images of sufficiently dilated images were used. As a standard image acquisition method, the image of the end-systolic section, which has the best evaluation of vascular lesions when using intravascular ultrasound, was acquired retrospectively through the DCAS PACS program to set the standard. When setting the measurement method criteria, we proposed a standard setting method that corresponds to the concentric and eccentric circles of normal and lesion vessels. By applying this criterion, we proposed a method for measuring the lumen and lateral cavities of normal and lesion vessels of interest and background area. In conclusion, if the image quality of intravascular ultrasonography is measured through the method devised by these researchers, consistent quality measurement is possible regardless of the type of intravascular ultrasound catheter. Therefore, it is thought that it can be applied as a guideline for the actual image quality measurement method in the study related to intravascular ultrasound image quality.
Keywords
IVUS; Image Quality Measurement; Image Analysis Program;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 S. J. Choi, J. G. Kang, S. I. Kim, Y. H. Kim, D. G. Lee, J. G. Jung, A. A. Cho, J. H. Jang, D. C. Kweon, "A Comparative Study of CTDI and the Effective Dose and the SNR accordingto the Area in the Abdominal CT", Journal of Radiological Science and Technology, Vol. 38, No. 3, pp. 245-252, 2015. https://doi.org/10.17946/JRST.2015.38.3.08   DOI
2 L. S. Folio, G. Wollstein, J. S. Schuman, "Optical Coherence Tomography: Future Trends for Imaging in Glaucoma", Optometry and Vision Science, Vol. 89, No. 5, pp. 554-562, 2013. http://dx.doi.org/10.1097/OPX.0b013e31824eeb43   DOI
3 B. C. Choi, "Ultrasound diagnostic device Coronary arteries stenosis Safety Efficiency Evaluation", Ministry of Food and Drug Safety, pp. 207-209, 2013.
4 Y. H. Seo, J. N. Song, "Development of Image Quality Measurement Method of Coronary Angiography Using Image Analysis Program", Journal of the Korean Society of Radiology, Vol. 14, No. 2, pp. 110-120, 2020. https://doi.org/10.7742/jksr.2020.14.2.111   DOI
5 K. R. Waters, R. Bautista, R. Zelenka, D. Masters, J. S. Reynolds, S. Nelson, D. H. Lam, et al, "Development of a high-definition intravascular ultrasound imaging system and catheter", IEEE International Ultrasonics Symposium, 2011. https://doi.org/10.1109/ULTSYM.2011.0440   DOI
6 B. K. Hong, S. Y. Cho, Y. S. Soo, and et al., "Intravascular Ultrasound Imaging in Patients with Acute Myocardial Infarction", Korean Circulation Journal, Vol. 28, No. 6, pp. 931-938, 1998.   DOI
7 G. Guagliumi, V. Sirbu, G. Musumeci, R. Gerber, G. Biondi-Zoccai, H. Ikejima, E. Ladich, N. Lortkipanidze, A. Matiashvili, O. Valsecchi, R. Virmani, G. W. Stone, "Examination of the In Vivo Mechanisms of Late Drug-Eluting Stent Thrombosis: Findings From Optical Coherence Tomography and Intravascular Ultrasound Imaging", Journal of the American College of Cardiology, Vol. 5, No. 1, pp. 315-324, 2014. http://dx.doi.org/10.1016/j.jcin.2011.09.018   DOI
8 J. Y. Won, D. Y. Lee, H. B. gi, "Intravascular Ultrasonography", Korean Society of Ultrasound in Medicine, Vol. 19 No. 2, pp. 61-70, 2000.
9 Y. H. Seo, J. N. Song, "Analysis of the ESD and DAP According to the Change of the Cine Imaging Condition of Coronary Angiography and Usefulness of SNR and CNR of the Images: Focusing on the Change of Tube Current", Journal of the Korean Society of Radiology, Vol. 13, No. 3, pp. 371-379, 2019. https://doi.org/10.7742/jksr.2019.13.3.371   DOI
10 G. S. Mintz, "Clinical Utility of Intravascular Imaging and Physiology in Coronary Artery Disease", Journal of the American College of Cardiology, Vol. 64, No. 2, pp. 207-222, 2014. https://doi.org/10.1016/j.jacc.2014.01.015   DOI
11 C. D. Mario, G. Gorge, R. Peters, P. Kearney, F. Pinto, D. Hausmann, C. von Birgelen, A. Colombo, H. Mudra, J. Roelandt, R. Erbel, "Clinical application and image interpretation in intracoronary ultrasound", European Heart Journal, Vol. 19, No, 2, pp. 207-229, 1998. http://dx.doi.org/10.1053/euhj.1996.0433   DOI
12 D. H. Kim, S. I. Choi, E. J. Chun, and et al., "Coronary CT Angiography: Focus on a New Algorithm as Diagnostic Tool in Routine Clinical Practice", The Korean Society of Radiology, Vol. 56, pp. 461-472, 2007. http://dx.doi.org/10.3348/jkrs.2007.56.5.461   DOI
13 J. S. Lee, S. J. Ko, S. S. Kang, J. H. Kim, D. H. Kim, C. S. Kim, "Quantitative Evaluation of Image Quality using Automatic Exposure Control & Sensitivity in the Digital Chest Image", Journal of the Korea Contents Association, Vol. 13, No. 8, pp. 275-283, 2013. https://doi.org/10.5392/JKCA.2013.13.08.275   DOI
14 K. W. Kim, J. W. Min, K. Y. Lyu, J. M. Kim, H. W. Jeong, J. A. Lee, J. H. Jung, D. C. Sung, S. C. Park, "Comparison Study on CNR and SNR of Thoracic Spine Lateral Radiography", Journal of Radiological Science and Technology, Vol. 36, No. 4, pp. 273-280, 2013.
15 M. Y. Jung, Y. H. Seo, J. N. Song, J. B. Han, "Analysis of the Relationships Between ESD and DAP, and Image SNR.CNR According to the Frame Change of Cine Imageing in CAG: With Focus on 10f/s and 15 f/s", Journal of the Korean Society of Radiology, Vol. 12, No. 5, pp. 668-675, 2018. http://dx.doi.org/10.7742/jksr.2018.12.5.669   DOI