• Title/Summary/Keyword: ultrafiltration flux

Search Result 206, Processing Time 0.021 seconds

Studies on the Separation of Taste Components from Sea Tangle (Laminaria japonica) Extract by Cross Flow Ultrafiltration (한외여과에 의한 다시마 정미성분 분리에 대한 연구)

  • Lee, Ho-Bong;Lee, Seung-Ryeol;Chang, Young-Sang;Shin, Zae-Ik
    • Korean Journal of Food Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.199-203
    • /
    • 1992
  • This study was aimed to optimize the required condition for recovering the low soluble taste component obtained from sea tangle extract using ultrafiltration, and to investigate effects of membrane type, temperature, transmembrane pressure and flow rate respectively. We also compared relationship between the profile of permeate flux and the recovery yield of taste component under the selected optimal condition using ultrafiltration and diafiltration. Hydrophobic GR 51 PP membrane kept higher average permeate flux than hydrophilic FS membrane, and average permeate flux also had increasing tendency in relation to rising flow rate but it showed limit value of 3.7 l/min. Average permeate flux decreased as transmembrane pressure increased but it showed little change with rising temperature. Investigation upon average permeate flux, total dissolved solid and recovery yield of taste components using ultrafiltration and diafiltration resulted in relatively higher recovery yield in ultrafiltration. Compared ultrafiltration and diafiltration, average permeate flux was lower in ultrafiltration.

  • PDF

Modeling of flux enhancement in presence of concentration polarization by pressure pulsation during laminar cross flow ultrafiltration

  • Kumar, Kamal;De, Sirshendu
    • Membrane and Water Treatment
    • /
    • v.1 no.4
    • /
    • pp.253-271
    • /
    • 2010
  • A theoretical study for the flux enhancement by pulsation of transmembrane pressure is presented for osmotic pressure controlled ultrafiltration under laminar flow regime. The transient velocity profile is solved analytically using Green's function method. Time dependent convective diffusive equation is solved to quantify the membrane surface concentration and the permeate flux, numerically. The effects of the amplitude and frequency of pulsation on flux, surface concentration and observed retention are studied.

Advanced Treatment for Reuse of Oil Refinery Process Wastewater using UF/RO Processes (UF/RO 공정을 이용한 정유공장 방류수의 재활용을 위한 고도처리)

  • 이광현
    • Membrane Journal
    • /
    • v.10 no.4
    • /
    • pp.220-229
    • /
    • 2000
  • Deionized water and wastewater flux were discussed using module set 1-7 composed of ultrafiltration hollow fiber type modules and reverse osmosis spiral wound type modules. The separation characteristics of ultrafiltration and reverse osmosis membranes were discussed with the variation of applied pressure and temperature. Turbidity and SS were removed effectively from ultrafiltration mem¬brane, and removal efficiency of COD, T-N, and TDS using reverse osmosis membrane was very efficient. Permeate flux increased linearly with the increase of applied pressures and temperature. It was shown that ultrafiltration and reverse osmosis membranes were suitable Lo the advanced treatment and reuse of oil refinery process effluent.

  • PDF

Empirical modelling of chemically enhanced backwash during ultrafiltration process

  • Daramola, M.O.;Adeogun, A.G.
    • Membrane and Water Treatment
    • /
    • v.2 no.4
    • /
    • pp.225-237
    • /
    • 2011
  • In this study, response of reversibility of membrane flux during chemically enhanced backwash (CEB) to changes in filtration time, filtration flux and coagulant concentration dosing during ultrafiltration (UF) process was investigated using a regression model. The model was developed via empirical modelling approach using response surface methodology. In developing the model, statistically designed UF experiments were conducted and the results compared with the model output. The results showed that the performance of CEB, evaluated in terms of the reversibility of the membrane flux, depends strongly on the changes in coagulant concentration dosage and the filtration flux. Also the response of the reversibility of membrane flux during CEB is independent of the filtration time. The variance ratio, VR << $F_{value}$ and $R^2$ = 0.98 obtained from the cross-validation experiments indicate perfect agreement of the model output with experimental results and also testify to the validity and suitability of the model to predict reversibility of the membrane flux during CEB in UF operation.

Ultrafiltration Characteristics of Hot-Water Extracts from Siberian Larch Barks for Tannin-based Adhesives (타닌접착제를 위한 시베리아산 낙엽송 수피 온수추출물의 한외여과 특성)

  • Cho, Nam-Seok
    • Journal of the Korean Wood Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.37-41
    • /
    • 1997
  • Hot-water soluble extracts were prepared from medium-sized barks of Siberian larch (Larix gmelineii). The extracts were fractionated by ultrafiltration method for producing uniform quality of adhesives. Molecular weight distribution of the extracts was ranged of 100 to 300.000. pH of the extracts affected amounts of flux, and the range of pH 6~pH 8 was proper for wood adhesives, because of easy concentration and fast gelation time. Removal of particles greater than $0.45{\mu}m$ from the extracts increased both filtration speed (flux) and yields of solids in the filtrates. In ultrafiltration process. operating pressure, filtrate temperature, and flow rate significantly increased with the increase of individual condition. Ultrafiltration using PM10 membrane was very effective to fractionate and concentrate the extracts. Removal of large particles greater than 0.45 m from the extracts increased filtration speed(flux) and yields of solids in the filtrates. A gelation time was accelerated with the increasing pH of the extracts and its concentration. The Stiasny precipitate(26%) from the filtrate obtained by PM 10 membrane was very lower than that(78%) of the retentates. This ultrafiltration method was efficient for obtaining high yield purified phenolic compounds.

  • PDF

Dialysis with ultrafiltration through countercurrently parallel-flow membrane modules

  • Yeh, Ho-Ming;Chen, Chien-Yu
    • Membrane and Water Treatment
    • /
    • v.4 no.3
    • /
    • pp.191-202
    • /
    • 2013
  • The application of ultrafiltration operation to the dialysis in countercurrently parallel-flow rectangular membrane modules was investigated. The assumption of uniform ultrafiltration flux was made for operation with slight concentration polarization and declination of transmembrane pressure. Considerable improvement in mass transfer is achievable if the operation of ultrafiltration is applied, especially for the system with low mass transfer coefficient. The enhancement in separation efficiency is significantly increased with increasing ultrafiltration flux, as well as with increasing the volumetric flow rates. Furthermore, increasing the volumetric flow rate in retentate phase is more beneficial to mass transfer than increasing in dialysate phase.

Improvement of Convection by Pulsatile Blood Pump in High Flux Hemodialysis System (고 유량 혈액 투석 시스템에서 박동류 펌프에 대한 대류 향상에 관한 연구)

  • Choi, D.S.;Um, K.M.;Lee, J.C.;Lee, S.R.;Mun, C.H.;Choi, H.;Min, B.G.;Kim, H.C.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.5
    • /
    • pp.376-383
    • /
    • 2008
  • High-flux dialysis treatment removes various toxins via diffusion as well as convection, which is induced by ultrafiltration and backfiltration. In this study, in vitro (Using the distilled water and the bovine's blood) comparison test was performed to determine whether utilization of a high flux dialyzer paired with different pumps would increase the efficiency of convection. At the same blood flow rates, a pulsatile pump and a roller pump were employed to propel the distilled water and bovine whole blood to a high flux dialyzer. Pressures at the dialyzer inlet and outlet in the blood circuit and in the dialysate circuit were measured, respectively. From these data, we calculated the transmembrane pressure and predicted the ultrafiltration and backfiltration rates developed by both pumps. Using the bovine's blood experiment, ultrafiltration and backfiltration rates were 1.6 times higher with the pulsatile pump than with the roller pump. We conclude that utilization of a pulsatile pump in high flux hemodialysis treatments increases ultrafiltration volume, compared with a roller pump under conditions of the same blood flow rate.

Separation Performance and Application of Sericin Protein in Silk Degumming Solution(1) (실크 정련 세리신 단백질의 분리특성과 응용(1))

  • Cha, Chin-U;Bae, Kie-Seo;Park, In-Woo;Kim, Yong-Duck;Hong, Young-Ki
    • Textile Coloration and Finishing
    • /
    • v.21 no.6
    • /
    • pp.56-63
    • /
    • 2009
  • In this study we have evaluated the separation characteristics and concentration of sericin using tubular type ultrafiltration membrane in silk degumming solution that extracted from electrolytic reduction water process. Ultrafiltration membranes have used in sericin separation performance and the separation characteristics of membrane satisfied typical Hagen-Poiseuille equation. It had the increase of flux according to the increase of feed pressure and temperature in occasion of pure water flux. And also the flux and solute rejection had about $25{\sim}60{\ell}/m^2{\cdot}h$ and more than 95% in sericin feed solution with concentration 1.00~1.89% at feed pressure force of $3{\sim}8kgf/cm^2$ respectively. In addition, the separation performance of tubular type ultrafiltration membrane for silk degumming solution was very steady-state with long experiment time.

Application of Box Wilson experimental design method for removal of acid red 95 using ultrafiltration membrane

  • Akdemir, Ezgi Oktav
    • Membrane and Water Treatment
    • /
    • v.9 no.5
    • /
    • pp.309-315
    • /
    • 2018
  • The applicability of the ultrafiltration process for color removal from dye-containing water has been examined in this study. The optimization of major process variables, such as dye concentration, chitosan concentration and transmembrane pressure on permeate flux and color removal efficiency was investigated. To find the most appropriate results for the experiment, the Box-Wilson experimental design method was employed. The results were correlated by a response function and the coefficients were determined by regression analysis. Permeate flux variation and color removal efficiency determined from the response functions were in good agreement with the experimental results. The optimum conditions of chitosan concentration, dye concentration and pressure were 50 mg/l, 50 mg/l and 3 bars, respectively for the highest permeate flux. On the other hand, optimum conditions for color removal efficiency were determined as 50 mg/l of dye concentration, 50 mg/l of chitosan concentration and 1 bar of pressure.

Fouling Mechanism of Microfiltration/Ultrafiltration by Macromolecules and a Suppression Strategy from the Viewpoint of the Hydration Structure at the Membrane Surface

  • Akamatsu, Kazuki;Nagumo, Ryo;Nakao, Shin-ichi
    • Membrane Journal
    • /
    • v.30 no.4
    • /
    • pp.205-212
    • /
    • 2020
  • This short review focuses on fouling by proteins and macromolecules in microfiltration/ultrafiltration. First, an experimental system that enables investigation of how the extent of the adsorption of proteins and macromolecules on membrane surfaces contributes to a decrease in filtrate flux in microfiltration/ultrafiltration is described. Using this system, a causal relationship - not a correlation - indicating that adsorption results in a decrease in filtrate flux could be clearly demonstrated in some cases. Second, a hydration structure at the membrane surface that can suppress adsorption is discussed, inspired by biomaterial research. In their hydrated states, polymers with low-fouling properties have water molecules with a particular structure. Finally, some successful examples of the development of low-fouling membranes via surface modification using low-fouling polymers are discussed.