Epitaxy of Si and Si1-xGex(001) by ultrahigh vacuum ion-beam sputter deposition

  • Lee, N. E.;Greene, J. E.
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제2권2호
    • /
    • pp.107-117
    • /
    • 1998
  • Epitaxial undoped and Sb-doped si films have been grown on Si(001) substrates at temperatures T between 80 and 750$^{\circ}C$ using energetic Si in ultra-high-vacuum Kr+-ion-beam sputter deposition(IBSD). Critical epitaxial thicknesses te, The average thickness of epitaxial layers, in undoped films were found to range from 8nm at Ts=80$^{\circ}C$ to > 1.2 ${\mu}$m at Ts=300$^{\circ}C$ while Sb incorporation probabilities $\sigma$sb varied from unity at Ts 550$^{\circ}C$ to 0.1 at 750$^{\circ}C$. These te and $\sigma$Sb values are approximately one and one-to-three orders of magnitude, respectively, higher than reported results achieved with molecular-beam epitaxy. Plan-view and cross-sectional transmission electron microscopy, high-resolution x-ray diffraction, channeling and axial angular-yield profiles by Rutherford back scattering spectroscopy for epitaxial Si1-x Gex(001) alloy films (0.15$\leq$x$\leq$0.30) demonstrated that the films are of extremely high crystalline quality. critical layer thicknesses hc the film thickness where strain relaxation starts, I these alloys wre found to increase rapidly with decreasing growth temperature. For Si0.70 Ge0.30, hc ranged from 35nm at Ts=550$^{\circ}C$ to 650nm at 350$^{\circ}C$ compared to an equilibrium value of 8nm.

  • PDF

3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming (Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System)

  • 김판기;임종우;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권2호
    • /
    • pp.95-102
    • /
    • 2007
  • 목적: 3.0 Tesla와 같은 고 자장에서 고해상도의 나선주사영상을 얻기 위해서는 주자장을 균일하게 만들어야 한다. 특히, 나선주사영상인 경우 스핀-에코펄스 시퀀스(SE)나 경사자계 에코 펄스 시퀀스(GE)에 비하여 측정 시간이 길기 때문에 주자장이 균일하지 못하다면, off-resonance 현상으로 영상의 blur가 심해진다. 본 연구에서는 빠른 시간 안에 주자장을 균일하게 할 수 있는 고차(Higher-order) shimming방법을 모색했다. 대상 및 방법: 3 Tesla 자기 공명 영상시스템에서 고해상도의 나선주사영상을 얻기에 적합할 정도의 균일한 주자장을 빠른 시간 안에 만들기 위해, 한번의 스캔으로 axial, sagittal, coronal 방향의 불균일도 map을 구할 수 있는 펄스 시퀀스를 제안하였고, 불균일도 map으로부터 spherical harmonics 분석를 통해 shim 코일에 적절한 전류를 인가하여 주자장을 균일하게 만들었다. 결과: 3 Tesla 자기 공명 영상 시스템에서 주자장의 불균일도는 주자장의 크기에 비례하게 된다. 제안한 펄스 시퀀스로 얻은 영상을 이용하여 불균일도 Map을 만들 수 있었고, 이를 spherical harmonics 분석을 하여 2-3회의 고차 shimming으로 불균일한 자장을 균일하게 만들 수 있었다. 제안된 고차 shimming 방법은 전체 영상 영역 뿐만 아니라 선택한 영역에 대해서만 적용도 가능하기 때문에 국부 영역에 대한 고차 shimming이 가능하다. 고차 shimming이 적용되어 주자장이 균일하게 개선된 상태에서 고해상도의 나선주사영상을 얻을 수 있었다. 결론: 3 Tesla 고자장 자기 공명 영상 시스템에서 주자장의 불균일도를 개선하기 위한 펄스 시퀀스와 알고리즘을 통해 주자장의 불균일도를 빠른 시간 안에 개선할 수 있었다. 주자장의 불균일도를 효과적으로 개선함으로써, 고해상도의 나선주사 영상을 얻을 수 있었다.

  • PDF

Characterization of Particulate Emissions from Biodiesel using High Resolution Time of Flight Aerosol Mass Spectrometer

  • Choi, Yongjoo;Choi, Jinsoo;Park, Taehyun;Kang, Seokwon;Lee, Taehyoung
    • Asian Journal of Atmospheric Environment
    • /
    • 제9권1호
    • /
    • pp.78-85
    • /
    • 2015
  • In the past several decades, biofuels have emerged as candidates to help mitigate the issues of global warming, fossil fuel depletion and, in some cases, atmospheric pollution. To date, the only biofuels that have achieved any significant penetration in the global transportation sector are ethanol and biodiesel. The global consumption of biodiesel was rapidly increased from 2005. The goal of this study was to examine the chemical composition on particulate pollutant emissions from a diesel engine operating on several different biodiesels. Tests were performed on non-road diesel engine. Experiments were performed on 5 different fuel blends at 2 different engine loading conditions (50% and 75%). 5 different fuel blends were ultra-low sulfur diesel (ULSD, 100%), soy biodiesel (Blend 20% and Blend 100%) and canola biodiesel (Blend 20% and Blend 100%). The chemical properties of particulate pollutants were characterized using an Aerodyne High Resolution Time of Flight Aerosol Mass Spectrometer (HR-ToF-AMS). Organic matter and nitrate were generally the most abundant aerosol components and exhibited maximum concentration of $1207{\mu}g/m^3$ and $30{\mu}g/m^3$, respectively. On average, the oxidized fragment families ($C_xH_yO_1{^+}$, and $C_xH_yO_z{^+}$) account for ~13% of the three family sum, while ~87% comes from the $C_xH_y{^+}$ family. The two peaks of $C_2H_3O_2$ (m/z 59.01) and $C_3H_7O$ (m/z 59.04) located at approximately m/z 59 could be used to identify atmospheric particulate matter directly to biodiesel exhaust, as distinguished from that created by petroleum diesel in the AMS data.

Surface Imaging of Barley Aleurone Cell by Atomic Force Microscopy

  • Kim, Tae-Wan;Huh, Kwang-Woon;Kim, Seung-Hwan;Ku, Hyun-Hwoi;Lee, Byung-Moo;Kim, Jae-Yoon;Seo, Yong-Won
    • 한국작물학회지
    • /
    • 제49권1호
    • /
    • pp.36-40
    • /
    • 2004
  • To observe and analysis ultra-microscopically barley aleurone cell surface, atomic force microscope (AFM) was used. Seed coat of early maturing germplasm, eam9, was dehulled and scanned by non-contact mode. We have obtained the high resolution topographic 3-dimensional image of barley aleurone layer with high resolution. These images showed the membrane proteins in barley aleurone cell. One channel protein and numerous peripheral or integral proteins were detected in a area of 100 $\mu\textrm{m}^2$. Furthermore, we found that their widths were ranged from 50 to 750nm and lengths from 0 to 66 $\mu\textrm{m}$. The thickness of aleurone layer was measured by scanning electron microscope. The thickness at early developmental stage was about 16 and then the aleurone cell enlarged upto 57 $\mu\textrm{m}$${\mu}{\textrm}{m}$ at least until 42 days after anthesis. In this study, we firstly reported on the ultrastructural AFM analysis of living aleurone cell as a biological specimen. It was clearly suggested that AFM will become an powerful tool for probing both the structural properties of biological samples.

$^{124}Te$ Target로 생산된 $^{123}I$ SPECT 영상에서의 조준기 선택 (Collimator Selection in $^{124}Te$ generated $^{123}I$ SPECT imaging)

  • 김희중;손혜경;봉정균;남기표;이희경
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.45-48
    • /
    • 1996
  • In the case of $^{123}I$ from the $^{124}Te$ (p,2n)reaction, the radionuclidic impurity is the high-energy gamma-emitting $^{124}I$, which interferes greatly with nuclear medicine images. The choice of a collimator can affect the quality of clinical SPECT images of [I-123]MIBG or [I-123]TPT. The tradeoffs that two different collimators make among spatial resolution, sensitivity, and scatter were studied by imaging a line source at 5cm, 10cm, 15cm distance using a number of plexiglass sheets between source and collimator, petri dist two-dimensional Hoffman brain phantom, and Jaszczak phantom after filling with $^{123}I$ (FWHM, FWTM, Sensitivity) for low energy ultra high resolution parallel hole(LEUHRP) collimator and medium energy general purpose (MEGP) collimator were measured as (9.27mm, 61.27mm $129CPM/[\mu}$ Ci) and (10.53m 23.17mm $105CPM/{\mu}$ Ci), respectively. The image quality of two-dimensional Hoffman brain Phantom with LEUHRP looked better than the one with MEGP. However, the image quality of Jasgczak phantom with LEUHRP looked much worse than the one with MEGP, The results suggest that the MEGP is preferable to LEUHRP for SPECT studies of [I-123]MIBG or [I-123]IPT.

  • PDF

$^{99m}Tc$용 콜리메타의 성능과 SPECT 화상의 영향 (Comparison of SPECT Images with $^{99m}Tc$ Collimators)

  • 이만구;이정옥;박성옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제24권2호
    • /
    • pp.35-40
    • /
    • 2001
  • Performance of SPECT imaging systems which use a rotating gamma camera, are affected by characteristics of the detector-collimator assembly, the data acquisition method, and the filter used in imaging reconstruction. The purpose of this study Is to examine image qualifies of SPECT with different types of low energy collimators. The SPECT imaging system in this study is a digital gamma camera system GCA-901A(Toshiba) and a data processing unit Scintipac-700(Shimadzu). The four types of collimators compared are UHR(ultra high resolution), LEHR(low energy high resolution), LEGP(low energy general purpose), and I-123 PAR(Parallel), with 0.27, 0.66, 1.00, and 2.06 relative sensitivity, respectively. In this case of the same collimators, the spatial resolutions measured in the slice plane showed a slight difference in the FWHM values(mean values of UHR, LEHR, LEGP, and I-123 PAR were 11.3 mm, 13.6 mm, 15.8 mm, and 20.4 mm, respectively) between the center and the circumference of the field of view, in the radial direction, but a large difference in the tangential direction, with lower FWHM values(values of UHR, LEHR, LEGP, and I-123 PAR were 8.4 mm, 8.7 mm, 9.3 mm, and 10.8 mm at 12 cm from the center, respectively). In comparison of SPECT images with the four types of collimators, except for the I-123 PAR collimator, image qualities of UHR, LEHR, and LEGP collimators showed only a slight difference. From the point of for, it is expected that the LEGP collimator would be suitable for SPECT imaging with $^{99m}Tc$.

  • PDF

UAV를 이용한 Subcentimeter GSD 영상의 취득 및 시각적 해상도 분석 (Acquisition of Subcentimeter GSD Images Using UAV and Analysis of Visual Resolution)

  • 한수희;홍창기
    • 한국측량학회지
    • /
    • 제35권6호
    • /
    • pp.563-572
    • /
    • 2017
  • 본 연구의 목적은 회전익 UAV를 이용하여 1cm 미만의 GSD를 갖는 초고해상도 영상을 취득하기 위해 비행고도, 비행속도, 카메라 셔터의 노출시간, 자동초점조절 사용 여부가 영상의 시각적 해상도에 미치는 영향을 객관적으로 분석하는 것이다. 아울러 다양한 형태의 항공표적에 대한 인식 용이성을 평가하는 것도 목표로 한다. 이를 위해 35mm 크기의 7952*5304 화소 CMOS 센서와 55mm 단렌즈를 이용하여 비행고도 20m부터 120m에서 20m 간격으로 촬영하고 영상의 시각적 해상도를 분석하였다. 결과로 자동초점조절을 사용한 경우 시각적 해상도는 이론적인 GSD에 비하여 1.1~1.6배로 나타났고, 자동초점조절을 사용하지 않은 경우 1.5~3.5배로 나타났다. 다음으로 비행고도 80m에서 5m/s로 정속 비행하면서 카메라의 노출 시간을 1/60sec에서 1/2000sec까지 1/2씩 줄이면서 촬영하고 시각적 해상도를 분석하였다. 허용 흐려짐을 1 화소로 가정할 때 최장 노출 시간을 준수한 경우 시각적 해상도 는 이론적인 GSD이 비하여 1.3~1.5배로 나타났고, 초과한 경우 1.4~3.0배로 나타났다. A4 용지에 항공표적을 출력하여 비행고도 80m 이내에서 촬영하면 상용소프트웨어를 이용하여 코드화된 항공표적을 자동으로 인식할 수 있으며, 자동 인식이 불가능한 고도에서도 다양한 형태의 일반 항공표적 및 코드화된 항공표적을 큰 어려움 없이 수동으로 인식할 수 있었다.

고해상도 엑스선 광전자 분광법을 이용한 다결정구조의 안티몬-테레니움 박막 연구 (High-Resolution X-Ray Photoelectron Spectroscopy Study of a Sb2Te3 Thin Film with the Polycrystalline Phase)

  • 이영미;김기홍;신현준;정민철;취야빙
    • 한국진공학회지
    • /
    • 제21권6호
    • /
    • pp.348-353
    • /
    • 2012
  • 스퍼터를 이용하여 실리콘 기판위에 제작된 안티몬-테레니움 다결정 박막을 방사광을 이용한 고해상도 엑스선 광전자 분광법 실험을 수행하여 화학적 상태를 분석하였다. 엑스선 회절 실험을 통해 제작된 안티몬-테레니움 박막은 롬보헤드럴 구조를 가지는 다결정임을 확인하였다. 엑스선 광전자분광법을 수행하기 위하여 표면의 산화막 제거를 위해 저에너지 네온 이온 스퍼터링을 빔에너지 1 kV로 1 시간동안 수행하였고, 이를 통해 표면 산화막이 완벽히 제거됨을 확인하였다. 또한, 스퍼처링에 의하여 표면 비정질화된 상태를 결정화 상태로 만들기 위해 상변화온도인 $100^{\circ}C$에서 5 분간 초고진공상태에서 열처리를 수행하였다. 이후 획득되어진 테레니움 4d와 안티몬 4d 속전자레벨 분석에서 각각의 묶음에너지가 40.4 그리고 33.0 전자볼트임을 확인할 수 있었으며, 각각은 단일한 화학적 상태를 나타내고 얻어진 피크의 밀도분석을 통해 화학적조성비가 2 : 3임을 확인하였다.

A 3 ~ 5 GHz CMOS UWB Radar Chip for Surveillance and Biometric Applications

  • Lee, Seung-Jun;Ha, Jong-Ok;Jung, Seung-Hwan;Yoo, Hyun-Jin;Chun, Young-Hoon;Kim, Wan-Sik;Lee, Noh-Bok;Eo, Yun-Seong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제11권4호
    • /
    • pp.238-246
    • /
    • 2011
  • A 3-5 GHz UWB radar chip in 0.13 ${\mu}m$ CMOS process is presented in this paper. The UWB radar transceiver for surveillance and biometric applications adopts the equivalent time sampling architecture and 4-channel time interleaved samplers to relax the impractical sampling frequency and enhance the overall scanning time. The RF front end (RFFE) includes the wideband LNA and 4-way RF power splitter, and the analog signal processing part consists of the high speed track & hold (T&H) / sample & hold (S&H) and integrator. The interleaved timing clocks are generated using a delay locked loop. The UWB transmitter employs the digitally synthesized topology. The measured NF of RFFE is 9.5 dB in 3-5 GHz. And DLL timing resolution is 50 ps. The measured spectrum of UWB transmitter shows the center frequency within 3-5 GHz satisfying the FCC spectrum mask. The power consumption of receiver and transmitter are 106.5 mW and 57 mW at 1.5 V supply, respectively.

역광전자분광기의 제작 및 그 응용 (Construction of Inverse Photoemission Spectrometer and Its Application)

  • 김정원;김세훈
    • 대한화학회지
    • /
    • 제40권12호
    • /
    • pp.719-723
    • /
    • 1996
  • 고체표면의 비점유 전자에너지 상태를 연구하고자 역광전자분광기를 제작하고 시험하였다. 이 분광기는 초고진공 챔버속에 전자총과 광검출기로 구성되어 있다. 전자총은 궤도 시뮬레이션과 전류 측정을 통해 좋은 집속도와 높은 전류밀도를 가지고 있음을 알 수 있었다. 이 분광기의 전체적인 분해능은 0.74 eV이고, 광검출기의 감도는 약 10 counts/$sec{\cdot}{\mu}A$이다. 하나의 결과로서 Ge(111) 시료의 역광전자분광 스펙트럼은 이론적인 계산결과와 잘 일치하였다.

  • PDF