• Title/Summary/Keyword: ultra-high performance

Search Result 992, Processing Time 0.033 seconds

Behaviors of UHPC-filled Q960 high strength steel tubes under low-temperature compression

  • Yan, Jia-Bao;Hu, Shunnian;Luo, Yan-Li;Lin, Xuchuan;Luo, Yun-Biao;Zhang, Lingxin
    • Steel and Composite Structures
    • /
    • v.43 no.2
    • /
    • pp.201-219
    • /
    • 2022
  • This paper firstly proposed high performance composite columns for cold-region infrastructures using ultra-high performance concrete (UHPC) and ultra-high strength steel (UHSS) Q960E. Then, 24 square UHPC-filled UHSS tubes (UHSTCs) at low temperatures of -80, -60, -30, and 30℃ were performed under axial loads. The key influencing parameters on axial compression performance of UHSS were studied, i.e., temperature level and UHSS-tube wall thickness (t). In addition, mechanical properties of Q960E at low temperatures were also studied. Test results revealed low temperatures improved the yield/ultimate strength of Q960E. Axial compression tests on UHSTCs revealed that the dropping environmental temperature increased the compression strength and stiffness, but compromised the ductility of UHSTCs; increasing t significantly increased the strength, stiffness, and ductility of UHSTCs. This study developed numerical and theoretical models to reproduce axial compression performances of UHSTCs at low temperatures. Validations against 24 tests proved that both two methods provided reasonable simulations on axial compression performance of UHSTCs. Finally, simplified theoretical models (STMs) and modified prediction equations in AISC 360, ACI 318, and Eurocode 4 were developed to estimate the axial load capacity of UHSTCs at low temperatures.

Control of Tensile Behavior of Ultra-High Performance Concrete Through Artificial Flaws and Fiber Hybridization

  • Kang, Su-Tae;Lee, Kang-Seok;Choi, Jeong-Il;Lee, Yun;Felekoglu, Burak;Lee, Bang Yeon
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.sup3
    • /
    • pp.33-41
    • /
    • 2016
  • Ultra-high performance concrete (UHPC) is one of the most promising construction materials because it exhibits high performance, such as through high strength, high durability, and proper rheological properties. However, it has low tensile ductility compared with other normal strength grade high ductile fiber-reinforced cementitious composites. This paper presents an experimental study on the tensile behavior, including tensile ductility and crack patterns, of UHPC reinforced by hybrid steel and polyethylene fibers and incorporating plastic beads which have a very weak bond with a cementitious matrix. These beads behave as an artificial flaw under tensile loading. A series of experiments including density, compressive strength, and uniaxial tension tests were performed. Test results showed that the tensile behavior including tensile strain capacity and cracking pattern of UHPC investigated in this study can be controlled by fiber hybridization and artificial flaws.

Spalling resistance and mechanical performance of UHPC under high temperature using hybrid natural and artificial fibers

  • Arash K. Pour;Amir Shirkhani;Ehsan Noroozinejad Farsangi
    • Structural Engineering and Mechanics
    • /
    • v.91 no.2
    • /
    • pp.177-195
    • /
    • 2024
  • This research plans to investigate the simultaneous impact of bamboo fibers (BF) and steel fibers (SF) on the mechanical and spalling characteristics of ultra-high-performance concrete (UHPC) exposed to high temperatures (HT). To this aim, 25 mixtures were made and assessed. BF was added at five contents of 0, 2.5, 5, 7.5 and 10 kg/m3. Additionally, SF was used at five weight contents: 0%, 1%, 2%, 3% and 4%. Specimens were exposed to temperatures ranging between 25℃ and 800℃. Thus, com-pressive, tensile, and flexural strengths, elastic moduli, mass loss, and permeability were measured. Experiments revealed that the simultaneous use of low BF and SF contents could totally prevent spalling of UHPC, but the use of either SF or BF alone could not prevent spalling at high levels of fibers. Besides, the synergetic positive impact of BF and SF on the spalling resistance of UHPC was by reason of the rise of BF' permeability and the bridging role of SF at HT. Moreover, it was concluded that the use of SF could moderate the adverse influence of BF on the compressive resistance of UHPC.

Improved Calibration for the Analysis of Emerging Contaminants in Wastewater Using Ultra High Performance Liquid Chromatography and Time-of-Flight Mass Spectrometry

  • Pellinen, Jukka;Lepisto, Riikka-Juulia;Savolainen, Santeri
    • Mass Spectrometry Letters
    • /
    • v.9 no.3
    • /
    • pp.77-80
    • /
    • 2018
  • The focus of this paper is to present techniques to overcome certain difficulties in quantitative analysis with a time-of-flight mass spectrometer (TOF-MS). The method is based on conventional solid-phase extraction, followed by reversed-phase ultra high performance liquid chromatography of the extract, and mass spectrometric analysis. The target compounds included atenolol, atrazine, caffeine, carbamazepine, diclofenac, estrone, ibuprofen, naproxen, simazine, sucralose, sulfamethoxazole, and triclosan. The matrix effects caused by high concentrations of organic compounds in wastewater are especially significant in electrospray ionization mass spectroscopy. Internal-standard calibration with isotopically labeled standards corrects the results for many matrix effects, but some peculiarities were observed. The problems encountered in quantitation of carbamazepine and triclosan, due to nonlinear calibration were solved by changing the internal standard and using a narrower mass window. With simazine, the use of a quadratic calibration curve was the best solution.

Flexural behavior of UHPC-RC composite beam

  • Wu, Xiangguo;Lin, Yang
    • Steel and Composite Structures
    • /
    • v.22 no.2
    • /
    • pp.387-398
    • /
    • 2016
  • In order to evaluate the effects of U shape ultra high performance concrete (UHPC) permanent form on the behaviors of Reinforced Concrete (RC) beam, a full scale RC composite beam is designed and tested with U shape UHPC permanent form and a reference RC beam with same parameters is tested simultaneously for comparison. The effects of the permanent form on the failure mode, cracking strength, ultimate capacity and deformation are studied. Test results shows that the contributions of the U shape UHPC permanent form to the flexural cracking behaviors of RC beam are significant. This study may provide a reference for the design of sustainable RC beam with high durable UHPC permanent form.

Strength Characteristics of Ultra High Performance Concrete at early age

  • Kim, Sung-Wook;Park, Jung-Jun;Ryu, Guem-Sung;Koh, Kyoung-Taek;Hong, Ki-Nam
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.563-564
    • /
    • 2009
  • Ultra-High Performance Concrete (UHPC) compared to normal concrete is exhibiting extremely high strength characteristics with compressive strength and tensile strength reaching 200MPa and 15MPa, respectively. The mechanical characteristics of UHPC can be thus exploited advantageously in the construction of structure through the reduction of the cross-sectional area and fabrication of slim and light-weight of the structural members. In the case where the structural member is made of UHPC, the occurrence of crack can be prevented by releasing the restraint provided by the form in due time. This research performs parametric study of the failure characteristics of concrete such as failure energy and softening curve suggested by the viscous crack model approximating the failure of concrete. The scope of this research contains the results of tests performed to investigate the strength of UHPC during early elapsed time.

  • PDF

Impact resistant properties of Kagome truss reinforced composite panels

  • Choi, Jeong-Il;Park, Se-Eon;Lee, Sang-Kyu;Kim, Gyu-Yong;Hwang, Jae-Seung;Lee, Bang Yeon
    • Advances in concrete construction
    • /
    • v.12 no.5
    • /
    • pp.391-398
    • /
    • 2021
  • This paper presents an experimental study exploring impact resistant properties of Kagome truss reinforced composite panels. Three types of panels with different materials and reinforcements, i.e., ultra-high-performance mortar, steel fiber, and Kagome truss, were designed and manufactured. High-velocity projectile impact tests were performed to investigate the impact response of panels with dimensions of 200 mm×200 mm×40 mm. The projectile used in the testing was a steel slug with a hemispherical front; the impact energy was 1 557 J. Test results showed that the Kagome truss reinforcement was effective at improving the impact resistance of panels in terms of failure patterns, damaged area, and mass loss. Synergy effects of a combination of Kagome truss and fiber reinforcements for the improvement of impact resistance capacity of ultra-high-performance mortar were also observed.

Effect of environmentally friendly materials on steel corrosion resistance of sustainable UHPC in marine environment

  • Tahwia, Ahmed M.;Elgendy, Gamal M.;Amin, Mohamed
    • Structural Engineering and Mechanics
    • /
    • v.82 no.2
    • /
    • pp.133-149
    • /
    • 2022
  • This study investigates the resistance of sustainable ultra-high performance concrete (UHPC) on steel reinforcement corrosion. For enhancing the sustainability of UHPC, concrete mixes were prepared with ordinary Portland cement main binder, and mixes with moderate to high percentages of blast furnace cement (CEM III), fly ash (FA), and slag cement as partial replacements of the full quantity of the used cement. Linear polarization resistance technique was employed to estimate the electrochemical behavior of the concrete specimens. Results showed that the compressive strength and the resistance of steel to corrosion in marine environments can be enhanced by improving the sustainability of UHPC through incorporation of CEM III, FA, and slag cement. FA replacement of up to 50% with the addition of 15% SF content produced better compressive strength and steel corrosion resistance than slag cement whether with the use of ordinary Portland cement or blast furnace cement as the main binder.

Shear behavior of a demountable bolted connector in steel-UHPC lightweight composite structures

  • Gu, Jin-Ben;Wang, Jun-Yan
    • Structural Engineering and Mechanics
    • /
    • v.81 no.5
    • /
    • pp.551-563
    • /
    • 2022
  • Bolted connector could be an alternative to replace the conventional welded headed stud in steel-ultra high performance concrete (UHPC) lightweight composite structures. In this paper, a novel demountable bolted shear connector, consisting of a high-strength bolt (HSB) and a specially-designed nut which is pre-embedded in a thin UHPC slab, is proposed, which may result in the quick installation and disassembly, due to the mountable, demountable and reusable features. In order to study the shear behavior of the new type of bolted shear connector, static push-out tests were conducted on five groups of the novel demountable bolted shear connector specimens and one group of conventional welded headed stud specimen for comparison. The effect of the bolt shank diameter and aspect ratio of bolt on failure mode, shear stiffness, peak slip at the steel-UHPC interface, shear strength and ductility of novel bolted connectors is investigated. Additionally, design formula for the shear strength is proposed to check the suitability for assessment of the novel demountable bolted shear connectors.

Effect of Superplasticizer on Setting Time and compressive strength of Ultra High Performance Concrete (고성능 감수제 종류에 따른 초고성능 섬유보강 콘크리트의 응결 및 압축강도에 미치는 영향)

  • Baek, Sung-Jin;Hyun, Seung-Yong;kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.65-66
    • /
    • 2022
  • In this study, the setting characteristics of the high range water reducing agent to minimize the retardation of UHPC were confirmed to minimize the setting time in the hardening of UHPC. As a result of the study, there was a slight change depending on the difference in the type of Superplasticizer, K > P > D = S > E in the order of condensation promotion, and E > S = D = K > P on the 28th day.

  • PDF