• 제목/요약/키워드: ultimate capacity

검색결과 1,205건 처리시간 0.023초

파이프 골조온실의 원주형 콘크리트 기초의 인발저항력에 관한 연구 (A Study on the Uplift Capacity of Cylindrical Concrete Foundations for Pipe-Framed Greenhouse)

  • 윤용철;윤충섭;서원명;강만호
    • 한국농공학회지
    • /
    • 제40권4호
    • /
    • pp.109-119
    • /
    • 1998
  • Recently pipe-framed greenhouses are widely constructed on domestic farm area. These greenhouses are extremely light-weighted structures and so are easily damaged under strong wind due to the lack of uplift resistance of foundation piles. This experiment was carried out by laboratory soil tank to investigate the displacement be haviors of cylindrical pile foundations according to the uplift loads. Tested soils were sampled from two different greenhouse areas. The treatment for each soil type are consisted of 3 different soil moisture conditions, 2 different soil depths, and 3 different soil compaction ratios. Each test was designed to be repeated 2 times and additional tests were carried out when needed. The results are summarized as follows : 1. When the soil moisture content are low and/or pile foundations are buried relatively shallow, ultimate uplift capacity of foundation soil was generated just after begining of uplift displacement. But under the high moisture conditions and/or deeply buried depth, ultimate up-lift capacity of foundation soil was generated before the begining of uplift displacement. 2. For the case of soil S$_1$, the ultimate uplift capacity of piles depending on moisture contents was found to be highest in optimum moisture condition and in the order of air dryed and saturated moisture contents. But for the case of soil S$_2$, the ultimate uplift capacity was found to be highest in optimum moisture condition and in the order of saturated and air dryed moisture contents. 3. Ultimate uplift capacities are varied depending on the pile foundation soil moisture conditions. Under the conditions of optimum soil moisture contents with 60cm soil depth, the ultimate uplift capacity of pile foundation in compaction ratio of 80%, 85%, and 90% for soil 51 are 76kg, 115kg, and 155kg, respectively, and for soil S$_2$are 36kg, 60kg, and 92kg, respectively. But considering that typical greenhouse uplift failure be occurred under saturnted soil moisture content which prevails during high wind storm accompanying heavy rain, pile foundation is required to be designed under the soil condition of saturated moisture content. 4. Approximated safe wind velosities estimated for soil sample S$_1$and S$_2$are 32.92m/s and 26.58m/s respectively under the optimum soil condition of 90% compaction ratio and optimum moisture content. But considering the uplift failure pattern under saturated moisture contents which are typical situations of high wind accompanying heavy rain, the safe wind velosities for soil sample S$_1$and S$_2$are not any higher than 20.33m/s and 22.69m/s respectively.

  • PDF

모래로 치환된 점토지반의 지지력비에 따른 얕은 기초의 지지력 특성 (Characteristic of Bearing Capacity of Shallow Foundation upon Clay Ground Replaced by Sands Depending on Bearing Capacity Ratio)

  • 하영민;정민형;신효희;이송
    • 한국지반공학회논문집
    • /
    • 제27권11호
    • /
    • pp.17-25
    • /
    • 2011
  • 본 연구는 모래로 부분치환된 점토지반 위의 줄기초의 지지력 특성에 대한 것이다. 극한 지지력을 구하기 위해 FEM해석을 사용하였으며 부분치환은 기초의 폭의 비와 양단의 경사로 정의 하였다. B'=inf인 경우는 모래층이 점토층과 같은 반무한체인 경우로 이 때의 극한 지지력이 부분치환된 지반에서의 극한 지지력과 비교를 위해 사용하였다. 지지력 효율 ${\beta}$는 B'=inf인 경우의 극한 지지력과 부분치환에 의한 극한 지지력의 비로 모래로 부분치환된 점토지반의 지지력 특성을 파악하기 위해 사용하였다. 각각 3가지의 점토의 비배수 전단강도와 모래의 내부마찰각을 고려하였다. 분석결과 부분치환 시의 지지력효율 ${\beta}$에 가장 큰 요인은 치환깊이이다.

조립토 다짐말뚝의 지지력 특성 분석 - 모형토조실험 결과를 중심으로 (Analysis of Bearing Capacity Characteristics on Granular Compaction Pile - focusing on the Model Test Results)

  • 강윤;김홍택
    • 한국지반환경공학회 논문집
    • /
    • 제5권2호
    • /
    • pp.51-62
    • /
    • 2004
  • 조립토 다짐말뚝(granular compaction pile)공법은 비교적 강성이 크고 압축성이 작은 자갈, 쇄석 및 모래 등의 조립질 재료를 사용하여 연약한 지반에 말뚝을 조성하는 공법으로, 기초지반의 지지력 증가, 침하량 감소 및 압밀배수 촉진 등에 의한 지반개량 효과뿐 아니라, 사질토 지반에 적용시 지진에 의한 액상화 방지효과도 큰 공법으로 알려져 있으나 국내에서는 아직까지 널리 사용되지 않고 있다. 일반적으로 조립토 다짐말뚝은 Piled-raft system으로 시공되므로, 이 때 조립토 다짐말뚝의 극한지지력에 대한 평가는 팽창파괴 중심부의 깊이에 따라 달라지게 된다. 또한 조립토 다짐말뚝과 주변지반과의 하중분담에 대한 영향 및 지반내에서 조립토 다짐말뚝에 작용하는 구속응력의 변화를 적절하게 고려하여 조립토 다짐말뚝의 극한지지력이 결정되어야 한다. 본 연구에서는, 김 등(1998)에 의하여 연구되었던 조립토 다짐말뚝의 극한지지력 평가에 대한 해석기법을 토대로, 단일 말뚝에 대하여 상재하중의 크기, 재하면적의 크기 및 파괴깊이에 따른 수평구속응력의 변화를 고려하여 극한지지력을 산정하기 위한 기법을 제안하였다. 또한 제안된 조립토 다짐말뚝의 극한지지력 평가기법의 타당성을 실내모형실험을 통하여 검증하였으며, 실험결과를 토대로 하여 군말뚝의 지지력 증가효과 및 압밀계수의 변화에 대하여 비교, 분석을 실시하였다.

  • PDF

가압중수형 원전 격납건물의 성능평가에 관한 연구 (A Study on the Performance Assessment of PHWR Containment Building)

  • 이홍표;장정범
    • 한국전산구조공학회논문집
    • /
    • 제24권4호
    • /
    • pp.449-455
    • /
    • 2011
  • 최근 가압중수형 원전 격납건물의 내압능력 및 비선형 거동에 관한 실증실험과 해석코드에 대한 검증을 위하여 인도의 BARC 주관으로 가압중수형 격납건물 1/4 축소모델을 건설하였고, 내압성능평가를 위한 국제공동연구가 수행되었다. 이 논문은 가압중수형 1/4 축소모델 격납건물에 대한 내압성능과 비선형 거동을 예측하기 위하여 유한요소해석을 수행하였고 그 결과를 도출하였다. 대상 격납건물은 기초매트와 원통형 벽체 및 돔으로 구성되어 있고, 수평 텐던의 정착을 위하여 4개의 부벽(buttress)을 가지고 있다. 유한요소해석을 위하여 ABAQUS를 이용하였고 콘크리트, 철근 및 텐던에 대한 유한요소 모델을 작성하여 극한내압해석을 수행하였다. 유한요소해석결과 콘크리트의 초기 균열은 $1.6P_d$(design pressure)에서 발생하였고, 철근의 항복은 $3.36P_d$ 그리고 극한내압능력은 $4.0P_d$ 수준으로 나타났다.

Ultimate and fatigue response of shear dominated full-scale pretensioned concrete box girders

  • Saiidi, M. Saiid;Bush, Anita
    • Structural Engineering and Mechanics
    • /
    • 제23권4호
    • /
    • pp.353-367
    • /
    • 2006
  • Two full-scale, precast, pretensioned box girders were subjected to shear-dominated loading, one under monotonic loads to failure and the other subjected to one-half million cycles of fatigue loads followed by monotonic ultimate loads. The number of cycles was selected to allow for comparison with previous research. The fatigue loads were applied in combination with occasional overloads. In the present study, fatigue loading reduced the shear capacity by only six percent compared to the capacity under monotonic loading. However, previous research on flexure-dominated girders subjected to the same number of repeated loads showed that fatigue loading changed the mode of failure from flexure to shear/flexure and the girder capacity dropped by 14 percent. The comparison of the measured data with calculated shear capacity from five different theoretical methods showed that the ACI code method, the compression field theory, and the modified compression field theory led to reasonable estimates of the shear strength. The truss model led to an overly conservative estimate of the capacity.

RC 원형교각의 내진설계를 위한 전단성능곡선 (Shear Capacity Curve Model for Seismic Design of Circular RC Bridge Columns)

  • 이재훈;고성현;최진호;권순홍
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.93-96
    • /
    • 2005
  • Since the columns with flexure-shear failure have lower ductility than those with flexural failure, shear capacity curve models shall be applied as well as flexural capacity curve in order to determine ultimate displacement for seismic design or performance evaluation. In this paper, a modified shear capacity curve model is proposed and compared with the other models such as the CALTRANS model, Aschheim et al.'s model, and Priestley et al.'s model. Four shear capacity curve models are applied to the 4 full scale circular bridge column test results and the accuracy of each model is discussed. It may not be fully adequate to drive a final decision from the application to the limited number of test results, however the proposed model provides the better prediction of failure mode and ultimate displacement than the other models for the selected column test results.

  • PDF

내진설계를 위한 전단성능곡선 모델의 평가 (Evaluation of Shear Capacity Curve Model for Seismic Design)

  • 고성현;이재훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.186-189
    • /
    • 2006
  • Since the columns with flexure-shear failure have lower ductility than those with flexural failure, shear capacity curve models shall be applied as well as flexural capacity curve in order to determine ultimate displacement for seismic design or performance evaluation. In this paper, a proposed modified shear capacity curve model is compared with the other models such as the CALTRANS model, Aschheim et al.'s model, and Priestley et al.'s model. Four shear capacity curve models are applied to the 4 full scale and 7 small scale circular bridge column test results and the accuracy of each model is discussed. It may not be fully adequate to drive a final decision from the application to the limited number of test results, however the proposed model provides the better prediction of failure mode and ultimate displacement than the other models for the selected column test results.

  • PDF

쇄석말뚝의 지지력 특성에 관한 모형시험 연구 (A Model Test Study on the Bearing Capacity of the Crushed Stone Pile)

  • 이상익;박용원;김병일;윤길림
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.299-306
    • /
    • 2001
  • Crushed Stone Pile(CSP) is one of the ground improvement methods available to loose sand and clayey ground by forming compacted CSP in the weak soil layer. The effects of this method are enhancement of ground bearing capacity, reduction of settlement and prevention of lateral ground movement in cohesive layer, reduction of liquefaction potential in sandy ground. This study performs model tests in 1.0m${\times}$1.0m${\times}$1.0m and 1.5m${\times}$1.5m${\times}$l.2m model tank to observe bearing capacity of CSP treated ground. The area replacement ratio of CSP composite ground varies 20%, 30% and 40% with square grid pattern. After the composite ground was consolidated under pressure of 0.5kg/$\textrm{cm}^2$ and 1.0kg/$\textrm{cm}^2$, load tests were carried out. The results show that ultimate bearing capacity increases with area replacement ratio and the preconsolidation pressure of ground.

  • PDF

외삽법을 이용한 풍화암에 근입된 현장타설말뚝의 극한하중 예측 (Prediction of Ultimate Load of Drilled Shafts Embedded in Weathered Rock by Extrapolation Method)

  • 정성준;이상인;전종우;김명모
    • 대한토목학회논문집
    • /
    • 제29권4C호
    • /
    • pp.145-151
    • /
    • 2009
  • 일반적으로 풍화암에 근입된 현장타설말뚝은 지지력이 매우 크므로 많은 경우에 설계하중만을 검증한 다음 극한하중을 확인하기 전에 재하시험을 종료한다. 그러나 만일 미완성 하중-침하 곡선으로부터 신뢰할 수 있는 극한하중의 예측이 가능하다면 설계의 질적인 향상뿐만 아니라 경제적인 면에서도 크게 기여를 할 수 있을 것이라고 생각된다. 본 연구의 목적은 극한하중을 얻지 못한 말뚝 재하시험의 하중-침하 곡선으로부터 외삽법을 이용하여 추정한 극한하중의 신뢰성 판단 방법을 제안 하는데 있다. 이를 위해 극한하중이 구해진 10본의 말뚝을 3개 현장에 걸쳐서 수집하였다. 그리고 이 10개의 하중-침하 곡선으로부터 Davisson 방법을 이용하여 구한 실제 계측 극한하중의 25%, 50%, 60%, 70%, 80%, 그리고 90%에 해당하는 하중-침하 곡선 자료만이 확보되었다고 가상하고 각각의 자료에 대하여 쌍곡선 방법으로 외삽한 다음, 극한하중을 새로이 결정하였다. 이렇게 결정된 외삽 극한하중의 신뢰성을 통계분석을 통하여 평가하였다. 그 결과, 확보하였다고 가상한 하중-침하 곡선의 최대 침하량 대 외삽 극한하중에서의 침하량 비가 0.6 이상인 경우, 외삽으로 예측한 극한하중은 실제 계측 극한하중보다 평균적으로 20% 이내에서 보수적인 값을 나타내었다. 또한, 항타말뚝의 정재하시험 자료에 대하여 본 논문에서 제안한 방법으로 분석하여 동일한 결과를 확인하였다.

CANDU형 원자로 격납건물의 극한내압능력 평가에 관한 연구 (A Study on Evaluation of Ultimate Internal Pressure Capacity of CANDU-type Nuclear Containment Buildings)

  • 김선훈
    • 한국전산구조공학회논문집
    • /
    • 제24권3호
    • /
    • pp.343-351
    • /
    • 2011
  • 원자로 격납건물은 원자력발전소에서 발생가능한 모든 비상사태에 대한 최후의 방벽 역할을 하고 있다. 따라서 사고발생시 원자로 격납건물의 극한능력을 판단하는 것은 매우 중요하다. 대표적인 고려사항 가운데 하나인 LOCA사고 발생시 CANDU형 원자로 격납건물의 극한능력을 파악하기 위해서는 구조적 안전성 평가를 위한 구조해석이 필요하다. CANDU형 원자로 격납건물은 돔과 원통형벽체로 구성된 프리스트레스 콘크리트 쉘 구조물로서 부착식 텐돈을 사용하고 있다. 본 논문에서는 극한내압능력의 평가를 위하여 3차원 구조해석시스템을 사용한 프리스트레스 콘크리트 격납건물의 비선형해석을 수행하였다.