• 제목/요약/키워드: two-phase system

검색결과 2,660건 처리시간 0.031초

다이아몬드 인터체인지의 3 현시 신호운영 평가 (Assessment of Three-Phase Actuated Signal Operation at Diamond Interchanges)

  • 이상수
    • 대한교통학회:학술대회논문집
    • /
    • 대한교통학회 2002년도 제41회 학술발표회논문집
    • /
    • pp.143-159
    • /
    • 2002
  • The performance of two single-barrier three-phase actuated control systems at diamond interchanges was evaluated for various traffic conditions. To emulate the actuated signal control, hardware-in-the-loop system combined with CORSIM simulation program was used. Two performance measures, average delay and total stops, were used for the evaluation process. Results showed that the two three-phase systems gave similar performance in terms of average delay, but not stops. The delay performance of each phasing system was generally dependent on the traffic pattern and ramp spacing. The total stops decreased as the spacing increased, and it was the most sensitive variable that can differentiate between the two three-phase systems. It was also shown that the hardware-in-the-loop control could provide a good method to overcome the limitations of current simulation technology.

  • PDF

Solvent-localized in-situ NMR Monitoring by Intermolecular Single-quantum Coherence Study

  • Cha, Jin Wook;Park, Sunghyouk
    • 한국자기공명학회논문지
    • /
    • 제24권4호
    • /
    • pp.96-103
    • /
    • 2020
  • A new NMR method to monitor solvent-localized NMR signals in the two-phase liquid system is suggested. This method based on intermolecular single-quantum coherence (iSQC). Here, we exploited the feature of the local action of distant dipolar field (DDF) effect in order to filter out specific NMR signals dissolved in different solvents. This solvent specific iSQC spectroscopy was carried out on a model two-phase liquid system (D-glucose in water/palmitic acid in chloroform), and showed solvent-localized NMR signals. We believe our approaches might be useful in metabolic analysis such as two-phase liquid extraction scheme for labile chemical species.

Two-Phase Flow through a T-Junction

  • Tae Sang-Jin;Cho Keum-Nam
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권1호
    • /
    • pp.28-39
    • /
    • 2006
  • Two-phase flow through a T-junction has been studied by numerous researchers so far. The dividing characteristics of the gas and liquid phases at the T-junction are very complicated due to a lot of related variables. The prediction models have been suggested by using experimental data for a specific condition or working fluid. But, they showed the application limitation for the most of the other conditions or fluids. Since most of them are applicable for their own experimental range, the generalized model for the wide range of conditions and fluids is needed. Even though it's not available now, some of the models developed for air-water flow at a T-junction might be applicable for the part of refrigerants with some modifications. Especially, for the two-phase flow of refrigerants at the T-junction, very few studies have been performed. Further experimental study is required to be performed for the wide range of test conditions and fluids to predict properly the two-phase flow distribution and phase separation through the T-junction.

Partitioning of Recombinant Human Granulocyte-Macrophage Colony Stimulating Factor (hGM-CSF) from Plant Cell Suspension Culture in PEG/Sodium Phosphate Aqueous Two-phase Systems

  • Lee, Jae-Hwa;Loc, Nguyen-Hoang;Kwon, Tae-Ho;Yang, Moon-Sik
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제9권1호
    • /
    • pp.12-16
    • /
    • 2004
  • Partitioning of human granulocyte-macrophage colony stimulating factor (hGM-CSF) was achieved in the aqueous two-phase systems (ATPSs) using a crude extract of transgenic tobacco cell suspension culture. This study examined the effects of polyethylene glycol (PEG) molecular weight and concentration and the effects of sodium phosphate concentration in different PEG/sodium phosphate systems on the partition coefficient, K. The best ATPS system was 5% PEG 8,000/1.6 M sodium phosphate after 2 h of incubation at room temperature. In this system, hGM-CSF was partitioned in the PEG-rich phase with a yield of 57.99% and K$\_$hGM-CSF/ of 8.12. In another system, 3% PEG 10,000/1.6 M sodium phosphate, hGM-CSF was also partitioned primarily in the top phase with a yield of 45.66% and K$\_$hGM-CSF/ of 7.64 after 2 h of incubation at room temperature.

비정렬격자 2-유체 3-상 유동 해석 기법 (NUMERICAL METHOD FOR THE TWO-FLUID THREE-FIELD MODEL ON AN UNSTRUCTURED MESH)

  • 김종태;박익규;조형규;윤한영;정재준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 추계 학술대회논문집
    • /
    • pp.243-248
    • /
    • 2007
  • A three-dimensional (3D) unstructured hydrodynamic solver for transient two-phase flows has been developed. A two-fluid three-field model was adopted for the two-phase flows. The three fields represent a continuous liquid, an entrained liquid, and a vapour field. The hydrodynamic solver is for the 3D component of a nuclear system code and the component-scale analysis tools for transient two-phase flows. The finite volume method and unstructured grid are adopted, which are useful for the flows in a complicated geometry. The semi-implicit ICE (Implicit Continuous-fluid Eulerian) numerical scheme has been adapted to the unstructured non-staggered grid. This paper presents the numerical method and the preliminary results of the calculations. The results show that the numerical scheme is robust and predicts the phase change and the flow transitions due to boiling and flashing problems well.

  • PDF

A two-phase interface element for simulation of lining systems

  • Liu, X.;Scarpas, A.;Blaauwendraad, J.
    • Structural Engineering and Mechanics
    • /
    • 제11권5호
    • /
    • pp.547-564
    • /
    • 2001
  • The numerical formulation of a two-phase interface element appropriate for porous lining system is presented. The formulation is isoparametric and can be applied both for 2-D and 3-D analysis. Biot's theory is utilized as the basis for the development of the element constitutive theory. In order to be capable of simulating the reinforcing characteristics of some geotextiles utilized as lining system, a reinforcement component has also been implemented into the formulation. By employing this specially developed interface finite element, the influence of soil consolidation on the stress distribution along the lining system of a reservoir and a landfill has been investigated.

루프형 2상 유동 열사이폰 열교환기에 관한 연구 (Study on Two-Phase Loop Thermosyphon Heat Exchanger)

  • 이기우;박기호;이석호
    • 설비공학논문집
    • /
    • 제14권9호
    • /
    • pp.717-724
    • /
    • 2002
  • A heat exchanger (100,000 W) using two-phase loop thermosyphons (TLT) was developed as a waste heat recovery system. An experimental and simulation study was carried out on the heat transfer characteristics of TLT heat exchanger, and the results from the experiments were used to see the possibility which the TLT heat exchanger could be an alternate solution for waste heat recovery system. The experimental results showed the provisional results as a waste heat recovery system. Also computer simulation code can predict the TLT system about the effects of various variables for the operation. Computer simulation results based on the thermal resistance networks were compared with the experimental results. The study clearly shows that the computer simulation for the TLT heat exchanger can Predict the most cases of the affecting parameters involved, provided that correct empirical correlations are used.

계통 연계형 태양광 발전 시스템의 위상 동기화를 위한 디지털 PLL 제어 (Digital PLL Control for Phase-Synchronization of Grid-Connected PV System)

  • 김용균;최종우;김흥근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권9호
    • /
    • pp.562-568
    • /
    • 2004
  • The frequency and phase angle of the utility voltage are important in many industrial systems. In the three-phase system, they can be easily known by using the utility voltage vector. However, in the case of single phase system, there are some difficulties in detecting the information of utility voltage. In conventional system, the zero-crossing detection method is widely used, but could not obtain the information of utility voltage instantaneously. In this paper, the new digital PLL control using virtual two phase detector is proposed with a detailed analysis of single-phase digital PLL control for utility connected systems. The experimental results under various utility conditions are presented and demonstrate an excellent phase tracking capability in the single-phase grid-connected operation.

액체-기체 2상 유동장의 정확하고 강건한 해석 Part 2: 전 마하수 영역 해석을 위한 예조건화 (Accurate and Robust Computations of Gas-Liquid Two-Phase Flows Part 2: Preconditioned Two-Phase Schemes for All Speeds)

  • 임승원;김종암
    • 한국항공우주학회지
    • /
    • 제37권1호
    • /
    • pp.17-27
    • /
    • 2009
  • 압축성 영역에서 개발된 2상 유동 RoeM과 AUSMPW+를 전 마하수 영역 해석을 위해 예조건화 하였다. 압축성 영역에서 개발된 풍상차분 수치기법들은 수치점성에서 음속을 포함하는 항들을 갖고 있는데, 이는 비압축성 영역에서 관련 수치점성 크기를 지나치게 크거나 작게 만들어 해의 정확도를 떨어뜨리거나 수치 불안정 현상을 일으킨다. 따라서 예조건화된 시스템 고유값을 수치점성에 고려하여 전 마하수 영역에서 해의 정확성을 확보하였고, 점근 분석을 통해 개발된 수치기법이 비압축 극한 영역에서 보존형 지배방정식과 일관됨을 확인하였다. 수치 예제들을 통해 예조건화된 2상 유동 RoeM과 AUSMPW+가전 마하수 영역에서 합리적인 해를 도출함을 알 수 있었다.

Two-Phase Flow Regimes for Counter-Current Air-Water Flows in Narrow Rectangular Channels

  • Kim, Byong-Joo;Sohn, Byung-Hu;Siyoung Jeong
    • Journal of Mechanical Science and Technology
    • /
    • 제15권7호
    • /
    • pp.941-950
    • /
    • 2001
  • A study of counter-current two-phase flow in narrow rectangular channels has been performed. Two-phase flow regimes were experimentally investigated in a 760mm long and 100mm wide test section with 2.0 and 5.0mm gap widths. The resulting flow regime maps were compared with the existing transition criteria. The experimental data and the transition criteria of the models showed relatively good agreement. However, the discrepancies between the experimental data and the model predictions of the flow regime transition become pronounced as the gap width increased. As the gap width increased the transition gas superficial velocities increased. The critical void fraction for the bubbly-to-slug transition was observed to be about 0.25. The two-phase distribution parameter for the slug flow was larger for the narrower channel. The uncertainties in the distribution parameter could lead to a disagreement in slug-to-churn transition between the experimental findings and the transition criteria. For the transition from churn to annular flow the effect of liquid superficial velocity was found to be insignificant.

  • PDF