• Title/Summary/Keyword: turbidity removal

Search Result 329, Processing Time 0.025 seconds

An assessment of the effect of air scouring and swabbing pig cleaning technique on water distribution pipes (공기주입과 스와빙 피그를 이용한 상수관로 세척 효과 평가)

  • Bae, Cheolho;Lee, Doojin;Choi, Doo-Yong;Jun, Hongjin;Park, Sehyun;Choi, Taeho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.4
    • /
    • pp.459-468
    • /
    • 2015
  • Deposits discharged through the cleaning mainly were cement mortar, bitumen paintings and rust pieces, and fragments of perforation, stones and gravels. Deposits were more removed through swabbing pig cleaning rather than air scouring cleaning on the whole. However, air scouring cleaning were not influenced by the constraint conditions such as a change in the diameter or the presence of the valve in water mains compare to swabbing pig cleaning. So, it was thought that air scouring cleaning might be more favorable to water distribution network cleaning in the future. After the cleaning, water quality including residual chlorine and turbidity also was improved because of the removal of a significant amount of the deposits. Therefore, if the cleaning is continuously and regularly implemented in water mains, it is expected that it will help to recover the reliability and to preserve the health of water quality.

Temperature Effect in the process of DAF as pretreatment of SWRO (해수담수화 전처리로서 DAF공정에서 고온의 해수에 대한 영향 특성)

  • Park, Hyunjin;Dockko, Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.807-813
    • /
    • 2012
  • Flocculation and flotation are used as pretreatment steps prior to the reverse osmosis (RO) process. During seawater treatment, high temperature can change the water chemistry of seawater during the process of coagulation. It also affects bubble volume concentration (BVC) and bubble characteristics. Coagulants such as alum and ferric salts at $40^{\circ}C$ can also change flux rates in the seawater reverse osmosis (SWRO) process. In this study, the bubble characteristics in dissolved air flotation (DAF), used as a SWRO pretreatment process, were studied in synthetic seawater at $20^{\circ}C$ and $40^{\circ}C$. The flux of an RO membrane was monitored after dosing the synthetic seawater with coagulants at different temperatures. Results showed that BVC increases as the operating pressure increases and as the salt concentration decreases. The bubble size released at $40^{\circ}C$ is far smaller than that at $20^{\circ}C$The addition of a ferric salt is effective for turbidity removal in synthetic seawater at $20^{\circ}C$; it is more effective than alum. When synthetic seawater was dosed with a ferric salt, the RO membrane flux increased by 27 % at $40^{\circ}C$.

Causes of Fish Kill in the Urban Stream and Prevention Methods II - Application of Automatic Water Quality Monitoring Systen and Water Quality Modeling (도시 하천에서의 어류 폐사 원인 분석 II - 자동수질측정장치 및 수질모델의 사용)

  • Lee, Eun-hyoung;Seo, Dongil;Hwang, Hyun-dong;Yun, Jin-hyuk;Choi, Jae-hun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.4
    • /
    • pp.585-594
    • /
    • 2006
  • This study focused on the causes of fish kills and its prevention methods in Yudeung Stream, Daejeon, Korea. Intense field data, continuous water quality monitoring system and water quality modeling were applied to analyze the causes. Pollutant can be delivered to urban streams by surface runoff and combined sewer overflows in rainfall events. However, water quality analysis and water quality modeling results indicate that the abrupt fish kills in the Yudeung stream seems to be caused by combined effect of DO depletion, increase in turbidity and other toxic material. Excessive fish population in the study area may harm the aesthetic value of the stream and also has greater potential for massive fish kills. It is suggested to implement methods to reduce delivery of pollutants to the stream not only to prevent fish kills but also to keep balance of ecosystem including human uses. Frequent clean up of the urban surface and CSO, installation of detention basin will be helpful. In the long run, it seems combined sewer system has be replaced with separate sewer system for more effective pollutant removal in the urban area.

Characteristics of Foam Generation in Freshwater and Seawater (담수와 해수에서의 포말 생성 특성)

  • SHIN Jeong-Sik;KIM Byong-Jin;SUH Kuen-Hack
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.3
    • /
    • pp.179-185
    • /
    • 2004
  • The characteristics of foam generation were assessed for freshwater and seawater using a foam generator. Both in freshwater and seawater, the height of the foam layer increased with initial protein concentrations. The height of the foam layer also increased with pore size of the air distributor. The optimum superficial air velocities (SAV) in freshwater and seawater were 0.84 cm/sec and 0.6 cm/sec, respectively. The height of the foam layer was the highest in pH 3 in freshwater and in the region of pH 5-7 in seawater. The height of the foam layer increased with $NaHCO_3$ concentration in freshwater, and $NaHCO_3$ concentration had little effect in seawater. Removal efficiencies of total suspended solid (TSS) and turbidity decreased with an increase of initial protein concentrations in a batch foam separator both in freshwater and seawater.

Reuse of Weaving Wastewater with BAF Process (BAF 공정을 이용한 제직폐수의 재이용)

  • Jung, Yong-Jun;Bae, Jong-Hong;Kwon, Koo-Ho;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.664-669
    • /
    • 2004
  • An upflow BAF(Biological Aerated Filter) equipped with an expanded clay media was applied to reuse weaving wastewater of water jet loom. The performance of lab-scale biofilter was investigated by the adjustment of EBCTs(Empty Bed Contact Time) and the packing ratio of media, which were changed 1.1 to 3.7hr and 38 to 63%, respectively. In most conditions except 1.1hr of EBCT, BOD, CODcr, SS and Turbidity of the effluent were 1~4mg/L, 7~16mg/L, 1~5mg/L and 5~14NTU, where their removal efficiencies were 76~95%, 82~93%, 63~94% and 59~81%, respectively. From the observation of SEM(Scanning Electron Microscope) photographs of porous clay media, it was revealed that this media provided good performance of retaining microbes effectively. In addition, $0.44~0.49kgVSS/kgBOD_{rem}$. of low sludge reduction was expected. The most efficient back washing cycle and procedure were once per 4 to 9 days and air including collapse-pulsing method, respectively. Therefore, this system can be of use as an weaving wastewater treatment for reuse.

Evaluation of a Rapid Sand Filter with Surface Wash and Backwash Conditions (정수장 급속여과지 역세척 수위변화와 시간에 따른 세척 효율 평가)

  • Jung, Yong-Jun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.652-656
    • /
    • 2004
  • Both surface wash and backwash are considered as one of the most important methods that can improve the filtration efficiency in the existing water treatment plant. This study has mainly focused on the improvement of filtering efficiency by controlling surface wash and backwash time, and water level before backwash (when drained up to the trough, when drained up to 10 cm above filter bed, and when drained below 10 cm filter bed). Filtration efficiency was shown a little bit of differences depending on the operating conditions like surface wash injection pressure, the distance control between filter bed and the facility, and the types of surface wash. When the water level before backwash was reached up to 10 cm below filter bed after draining, however, the filtration velocity and the turbidity removal efficiency in the filter bed was improved. When the surface wash followed by backwash is longer, it showed a similar result. Because the proper adjustment of surface washing time makes filtration efficiency higher, therefore, it is necessary to set up the backwash time moderately.

Reuse of Weaving Wastewater by Membrane Bioreactor Equipped with a Hollow-fiber MF Membrane (중공사 정밀여과 MBR공정을 이용한 제직폐수의 재이용)

  • Jung, Yong-Jun;Bae, Jong-Hong;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.365-369
    • /
    • 2004
  • Submerged membrane bio-reactor equipped with a hollow fiber microfiltration was applied to reuse weaving wastewater of water jet loom, where two parameters such as the concentration of MLSS and the flux were controlled. While the flux at the concentration of MLSS around 900mg/L was constantly kept over 0.4m/d and 0.8m/d in a short time, the stable flux at around 300mg/L of MLSS was shown at the 8 days later. Regardless of MLSS and flux, BOD, CODcr and Turbidity of the permeate were 1~2mg/L, 7~10mg/L and below 1 NTU, which were 85~90%, 87~90% and 98% of removal efficiency, respectively. The stable operation without fouling was achieved because the contents of ECP were smaller than those of common MBR processes and the composition(saccharide/protein) was kept constantly. In this study, 0.5~1.0m/d of flux and 400~900mg/L of MLSS were considered as the most recommendable operating condition for the reuse of weaving wastewater.

The Feasibility Study of CMP Wastewater Treatment Using Tubular Membrane and Coagulants (응집제와 관형막을 활용한 CMP 폐수 처리 가능성 연구)

  • Jung, Ho Chan;Jung, Cheol Joong;Song, Ja Yeon;Kim, Youn Kook;Lee, Sun Yong
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.639-645
    • /
    • 2012
  • The purpose of this study is to identify the possibility of the CMP wastewater treatment from semiconductor fabrication under operating tubular membrane with coagulants. To find suitable coagulants treating CMP wastewater, we conducted Jar-test. After Jar-test experiments suitable coagulants are PAC(17%), $Ca(OH)_2$ and optimum coagulant dosage is PAC(17%) 10mg/L, $Ca(OH)_2$ 110 ~ 120mg/L. Based on these results, the tubular membrane was applied to CMP wastewater, the turbidity removal efficiency is $Ca(OH)_2$ > PAC(17%) > Nothing. The fast cross-flow velocity and backwash process what are operating characteristics of tubular membrane can be stable CMP wastewater treatment. But when the coagulant and tubular membrane are used at the same time, the withdraw and treatment of the CMP wastewater are possibile. However further treatment process needs if treated water will be used for semiconductor fabrications.

Design, fabrication, and performance analysis of a twisted hollow fibre membrane module configuration

  • Palmarin, Matthew J.;Young, Stephanie;Lee, Tsun Ho
    • Membrane and Water Treatment
    • /
    • v.6 no.1
    • /
    • pp.15-26
    • /
    • 2015
  • The compact structure and high-quality effluent of membrane bioreactors make them well-suited for decentralized greywater reclamation. However, the occurrence of membrane fouling continues to limit their effectiveness. To address this concern, a unique membrane module configuration was developed for use in a decentralized greywater treatment system. The module featured local aeration directly below a series of inclined membrane bundles, giving the overall module a twisted appearance compared to a module with vertically orientated fibres. The intent of this design was to increase the frequency and intensity of collisions between rising air bubbles and the membrane surface. Material related to the construction of custom-fit modules is rarely communicated. Therefore, detailed design and assembly procedures were provided in this paper. The twisted module was compared to two commercially available modules with diverse specifications in order to assess the relative performance and marketability of the twisted module with respect to existing products. Contaminant removal efficiencies were determined in terms of biochemical oxygen demand, chemical oxygen demand, ammonia, total nitrogen, total phosphorus, and turbidity for each module. Membrane fouling was monitored in terms of permeate flux, transmembrane pressure, and membrane resistance. Following 168 h of operation, the twisted module configuration demonstrated competitive performance, indicating good potential for further development and commercialization.

Industrial wastewater treatment by using of membrane

  • Razavi, Seyed Mohammad Reza;Miri, Taghi;Barati, Abolfazl;Nazemian, Mahboobeh;Sepasi, Mohammad
    • Membrane and Water Treatment
    • /
    • v.6 no.6
    • /
    • pp.489-499
    • /
    • 2015
  • In this work, treatment of real hypersaline refinery wastewater by hollow fiber membrane bioreactor coupled with reverse osmosis unit was studied. The ability of HF-MBR and RO developed in this work, was evaluated through examination of the effluent properties under various operating conditions including hydraulic retention time and flux. Arak refinery wastewater was employed as influent of the bioreactor which consists of an immersed ultrafiltation membrane. The HF-MBR/RO was run for 6 months. Average elimination performance of chemical oxygen demand, biological oxygen demand, total suspended solids, volatile suspended solids, total dissolved soild and turbidity were obtained 82%, 89%, 98%, 99%, 99% and 98% respectively. Highly removal performance of oily contaminant, TDS and the complete retention of suspends solids implies good potential of the HF-MBR/RO system for wastewater refinement.