• Title/Summary/Keyword: tubing

Search Result 248, Processing Time 0.036 seconds

Scale Thickness Measurement of Steam Generator Tubing Using Eddy Current Signal of Bobbin Coil (보빈코일 와전류신호를 이용한 증기발생기 세관 스케일 두께 측정)

  • Kim, Chang-Soo;Um, Ki-Soo;Kim, Jae-Dong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.545-550
    • /
    • 2012
  • Steam generator is one of the major components of nuclear power plant and steam generator tubes are the pressure boundary between primary and secondary side, which makes them critical for nuclear safety. As the operating time of nuclear power plant increases, not only damage mechanisms but also scaled deposits on steam generator tubes are known to be problematic causing tube support flow hole blockage and heat fouling. The ability to assess the extent and location of scaled deposits on tubes became essential for management and maintenance of steam generator and eddy current bobbin data can be utilized to measure thickness of scale on tubes. In this paper, tube reference standards with various thickness of scaled deposit has been set up to provide information about the overall deposit condition of steam generator tubes, providing essential tool for steam generator management and maintenance to predict and prevent future damages. Also, methodology to automatically measure scale thickness on tubes has been developed and applied to field data to estimate overall scale amount.

Experimental Study on Distally Based Free Flap Using Retrograde Arterial Flow (역행성 동맥 혈류를 이용한 원위 유리피판술의 실험적 연구)

  • Lee, Min-Goo;Minn, Kyung-Won
    • Archives of Reconstructive Microsurgery
    • /
    • v.7 no.1
    • /
    • pp.15-19
    • /
    • 1998
  • Microsurgical free-tissue transfer has allowed surgeons to salvage injured limbs but choosing appropriate healthy recipient vessels has proved to be a difficult problem. Retrograde flow flaps are established in island flaps. Retrograde flow anastomosis could prevent the possible kinking and twisting of the arterial anastomosis. By not interrupting the proximal blood flow to the fracture or soft tissue defect site, the compromise of fracture or wound healing might be prevented. We wished to estabilish an animal model in rat for a retrograde arterial flow based free flap. Nembutal-anesthetized male rats; weighing 250 to 300 gm, were used. The femoral artery and common carotid artery were exposed and divided. The systemic and retrograde arterial pressure were quantified by utilizing a parallel tubing system connected with peripheral arterial line. In this study, the retrograde flow was not pulsatile and the retrograde arterial pressure was 64-65mmHg, with a mean arterial pressure of 106-109mmHg. An epigastiic skin flap, measuring $3{\times}3cm$, was raised with its vascular pedicle. The epigastric free flap was transfered in the same rat from femoral vessels to carotid vessels in end to end fashion. We anastomosed the donor arteries to the distal parts of the divided recipient arteries and the donor veins to the proximal parts of the recipient veins. Twelve experiments were performed and the transplantations succeeded in 75 percent of them. In the remaining 25 percent, the experiments failed due to thrombosis at the site of anastpmosis, or other causes. This animal model represents an excellent example of retrograde arterial flow free flap transfer that is reliable.

  • PDF

Sprinkler System with Universal Solenoid Valve (범용 전자개방밸브를 적용한 스프링클러설비)

  • Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.351-357
    • /
    • 2019
  • This research is automatic Wet Pipe Sprinkler System, dry pipe Sprinkler System, preaction Sprinkler system, vacuum Sprinkler system, deluge Sprinkler system, etc., key components of each Sprinkler system, verve valve, valve, etc. This is to simplify the various processes of the manufacturing process into a single process to create an environment in which a single machine can simultaneously produce a standardized product, thereby improving the price competitiveness of the product, reducing the cost of maintaining the product, and making it more adaptable to the new sprinkler system that is developed in the future. Automatic Wet Pipe Sprinkler System, desipe Sprinkler System, preaction sprinkler system, vacuum Sprinkler system, deluge Sprinkler system, both types of existing Sprinkler system, only replace the primary and secondary tubing valves.It has the advantage of being easy to apply to the lower system. Legal and institutional research is needed for the commercialization of the Sprinkler system applying the solenoid valve as a future project.

Processing of Low Tin Zr-1Nb-0.69Sn-0.11Fe Alloy Tubes and Effect of Final Heat Treatment on Their Mechanical and Corrosion Properties (저 Sn 함유 Zr-Nb-Sn-Fe 합금 튜브 제조 및 최종 열처리 온도에 따른 기계적/부식특성 변화)

  • Cho, Nam Chan;Lee, Jong Min;Hong, Sun Ig
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.1
    • /
    • pp.17-24
    • /
    • 2011
  • To investigate the relationship between heat treatment in zirconium alloy tubing process and metallurgical characteristics of Zr-1Nb-0.69Sn-0.11Fe alloy tubes, mechanical and oxidation behaviors of tubes heat treated at different temperatures after the final pilgering were investigated. The stress strain curves exhibited the saturation behaviors in all heat treatment conditions ($460{\sim}600^{\circ}C$) in this study with the onset strain of saturation increased with increase of post-pilgering annealing temperature. The strength fell off rapidly with increasing annealing temperature. The ultimate strength of the low tin Zr-1Nb-0.69Sn-0.11Fe alloy with slightly higher iron and oxygen contents in this study was found to be higher than Zr-1Nb-1Sn-0.1Fe alloy. The oxidation experiments in steam condition revealed that the corrosion resistance of low tin Zr-1Nb-0.69Sn-0.11Fe alloy was better than the Zr-1Nb-1Sn-0.1Fe alloy with a higher Sn content. The weight gain of low tin Zr-1Nb-0.69Sn-0.11Fe alloy tubes gradually increased with the increasing annealing temperature possibly due to the decreased Nb content in the matrix because of the formation of ${\beta}-Nb$ particles.

Nationwide Analysis of Mortality Rates and Related Surgical Procedures in Hearing Disability Patients in South Korea

  • Han, Hye Min;Kwak, Ji Won;Kim, Hyeon Geun;Lee, Hoyoung;Kim, Young-Chan;Park, Euyhyun;Jung, Hak Hyun;Im, Gi Jung
    • Korean Journal of Audiology
    • /
    • v.24 no.4
    • /
    • pp.204-209
    • /
    • 2020
  • Background and Objectives: Hearing loss (HL) and its repercussions are major problems in today's society. There are limited data on the relationship between degree of HL and otologic disorders. The aim of this study is to estimate mortality rates, rates of sudden idiopathic HL and related otologic surgical procedures in hearing disability patients in South Korea. Subjects and Methods: Retrospective medical data for 160,205 patients with hearing disability was extracted. Mortality rates, rates of sudden idiopathic HL and related otologic surgical procedures were compared with a normal control group consisting of 865,475 people; approximately 5 times the number of hearing disability patients. Results: According to the Korean National Disability Registry (NDR), 0.458% of the population in South Korea suffered from hearing disability in 2015. Higher rates of mortality and sudden idiopathic HL were reported in hearing disability patients, increasing up to a maximum of 1.594 times and 1,039.695 times, respectively, compared to the normal control group. Mastoidectomy surgery was 2.5 times more frequently performed and pressure equalizing (PE) tube insertion was about 15 times more frequently performed in hearing disability patients. Conclusions: Hearing disability is related to higher risks of mortality, sudden idiopathic HL and otologic surgical procedures, including mastoidectomy and PE tubing.

Nationwide Analysis of Mortality Rates and Related Surgical Procedures in Hearing Disability Patients in South Korea

  • Han, Hye Min;Kwak, Ji Won;Kim, Hyeon Geun;Lee, Hoyoung;Kim, Young-Chan;Park, Euyhyun;Jung, Hak Hyun;Im, Gi Jung
    • Journal of Audiology & Otology
    • /
    • v.24 no.4
    • /
    • pp.204-209
    • /
    • 2020
  • Background and Objectives: Hearing loss (HL) and its repercussions are major problems in today's society. There are limited data on the relationship between degree of HL and otologic disorders. The aim of this study is to estimate mortality rates, rates of sudden idiopathic HL and related otologic surgical procedures in hearing disability patients in South Korea. Subjects and Methods: Retrospective medical data for 160,205 patients with hearing disability was extracted. Mortality rates, rates of sudden idiopathic HL and related otologic surgical procedures were compared with a normal control group consisting of 865,475 people; approximately 5 times the number of hearing disability patients. Results: According to the Korean National Disability Registry (NDR), 0.458% of the population in South Korea suffered from hearing disability in 2015. Higher rates of mortality and sudden idiopathic HL were reported in hearing disability patients, increasing up to a maximum of 1.594 times and 1,039.695 times, respectively, compared to the normal control group. Mastoidectomy surgery was 2.5 times more frequently performed and pressure equalizing (PE) tube insertion was about 15 times more frequently performed in hearing disability patients. Conclusions: Hearing disability is related to higher risks of mortality, sudden idiopathic HL and otologic surgical procedures, including mastoidectomy and PE tubing.

Stress Relaxation Behavior of Cold-worked and Annealed Zircaloy-4 Tubing

  • Rheem, K.S.;Choi, C.B.;Park, W.K.
    • Nuclear Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.203-207
    • /
    • 1976
  • Strain rate dependence of the flow stress of cold-worked and annealed Zircaloy-4 was studied by stress relaxation test in temperature range of 20$0^{\circ}C$ to 45$0^{\circ}C$. The In $\sigma$-ln i curves for various temperatures were straight in the eirange of 10$^{-5}$ to 10$^{-3}$ sec$^{-1}$ . From the slope of a curve strain rate sensitivity m was obtained. The m in cold-worked Zircaloy-4 had a minimum value at 30$0^{\circ}C$, while m in annealed Zircaloy-4 had two minimum values, one at 30$0^{\circ}C$ and the other at 45$0^{\circ}C$. It was found that the temperatures of the minimum m are consistent with the temperatures of strain ageing peaks. The minimum m at 30$0^{\circ}C$ is considered to be due to strain ageing owing to the pinning of glide dislocations by oxygen atoms, while the minimum m at 45$0^{\circ}C$ for annealed specimen is attributed to iron atoms.

  • PDF

Self Production of Radioisotope and Radiopharmaceuticals Divider (방사성동위원소 및 방사성의약품 분주장치의 자체제작)

  • Hong, Sung-Tack;Park, Kwang-Seo;Kim, Seok-Ki;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.177-180
    • /
    • 2010
  • Purpose: As PET test came to be covered by the pay system of medical insurance (July 1, 2006) and the needs for it becoming increased for laboratory purpose, it became necessary to purchase expensive medical equipments to solve those problems. However, as most of equipments that are operated by cyclotron are very expensive as to amount from tens of millions up to hundreds of millions of won, it is difficult to purchase those equipments from the point of medical organizations. It may be possible to self manufacture those equipments with least costs if their parts functions that meets the operators demands. The Nuclear Medicine department of National Cancer Center (NCC) is trying to manufacture and use equipments that can be made with least costs, including introducing 2 medical equipments that can improves the operator's works. Materials and Methods: Example 1: Self production of radioisotope($^{18}F$) divider was fabricated. The NCC's Nuclear Medicine department acquired one acrylic panel, seven 3-way valve, tubing etc. that can be found in the market to make the main body of divider in cooperation with biomedical engineering, and placed them inside hot cell, and installed switching box outside of hot cell to make it possible to control them from outside. This main body of divider were placed in radioisotope transfer line that are manufactured in the cyclotron. Example 2: Self production of $^{18}F$-FDG automated divider was fabricated. The NCC's Nuclear Medicine department used cavro pump syringe that consists the main body of divider in cooperation with biomedical engineering, biomedical engineering developed programs that divides a certain amount. $^{18}F$-FDG automated divider is placed inside hot cell, and cable chords were used in the equipment, and then it was connected to PC outside hot cell to make it possible to control the $^{18}F$-FDG automated divider. Results: From the NCC's Nuclear Medicine department tests that were carried out from March, 2007 until now, we found out that radioisotope can be sent to radiopharmaceuticals composite module we want, and from the tests that are carried out at NCC's Nuclear Medicine department using $^{18}F$-FDG automated divider since August, 2009 it was possible to distribute radiopharmaceuticals into vial intended. Conclusion: Through the two examples above, we found out that costs can be reduced by self manufacturing expensive equipments from NCC's cyclotron room with least costs. Also, it decreased radiation exposure dose on workers, and set up problem solving processes in cooperation with lots of parties related.

  • PDF

Developing a Dental Unit Waterline Model Using General Laboratory Equipments (실험실 일반 장비를 이용한 치과용 유니트 수관 모델 개발)

  • Yoon, Hye Young;Lee, Si Young
    • Journal of dental hygiene science
    • /
    • v.16 no.4
    • /
    • pp.284-292
    • /
    • 2016
  • Water supplied through dental unit waterlines (DUWLs) has been shown to contain high number of bacteria. To reduce the contamination of DUWLs, it is essential to develop effective disinfectants. It is, however, difficulty to obtain proper DUWL samples for studies. The purpose of this study was to establish a simple laboratory model for reproducing DUWL biofilms. The bacteria obtained from DUWLs were cultured in R2A liquid medium for 10 days, and then stored at $-70^{\circ}C$. This stock was inoculated into R2A liquid medium and incubated in batch mode. After 5 days of culturing, it was inoculated into the biofilm formation model developed in this study. Our biofilm formation model comprised of a beaker containing R2A liquid medium and five glass rods attached to DUWL polyurethane tubing. Biofilm was allowed to form on the stir plate and the medium was replaced every 2 days. After 4 days of biofilm formation in the laboratory model, biofilm thickness, morphological characteristics and distribution of the composing bacteria were examined by confocal laser microscopy and scanning electron microscopy. The mean of biofilm accumulation was $4.68{\times}10^4$ colony forming unit/$cm^2$ and its thickness was $10{\sim}14{\mu}m$. In our laboratory model, thick bacterial lumps were observed in some parts of the tubing. To test the suitability of this biofilm model system, the effectiveness of disinfectants such as sodium hypochlorite, hydrogen peroxide, and chlorhexidine, was examined by their application to the biofilm formed in our model. Lower concentrations of disinfectants were less effective in reducing the count of bacteria constituting the biofilm. These results showed that our DUWL biofilm laboratory model was appropriate for comparison of disinfectant effects. Our laboratory model is expected to be useful for various other purposes in further studies.

Establishment of a Dental Unit Biofilm Model Using Well-Plate (Well-Plate를 사용한 치과용 유니트 수관 바이오필름 모델 확립)

  • Yoon, Hye Young;Lee, Si Young
    • Journal of dental hygiene science
    • /
    • v.17 no.4
    • /
    • pp.283-289
    • /
    • 2017
  • The water discharged from dental unit waterlines (DUWLs) is heavily contaminated with bacteria. The development of efficient disinfectants is required to maintain good quality DUWL water. The purpose of this study was to establish a DUWL biofilm model using well-plates to confirm the effectiveness of disinfectants in the laboratory. Bacteria were obtained from the water discharged from DUWLs and incubated in R2A liquid medium for 10 days. The bacterial solution cultured for 10 days was made into stock and these stocks were incubated in R2A broth and batch mode for 5 days. Batch-cultured bacterial culture solution and polyurethane tubing sections were incubated in 12-well plates for 4 days. Biofilm accumulation was confirmed through plating on R2A solid medium. In addition, the thickness of the biofilm and the shape and distribution of the constituent bacteria were confirmed using confocal laser microscopy and scanning electron microscopy. The average accumulation of the cultured biofilm over 4 days amounted to $1.15{\times}10^7CFU/cm^2$. The biofilm was widely distributed on the inner surface of the polyurethane tubing and consisted of cocci, short-length rods and medium-length rods. The biofilm thickness ranged from $2{\mu}m$ to $7{\mu}m$. The DUWL biofilm model produced in this study can be used to develop disinfectants and study DUWL biofilm-forming bacteria.