• Title/Summary/Keyword: tube plate

Search Result 498, Processing Time 0.028 seconds

Transmission Noise Seduction Performance of Smart Panels using Piezoelectric Shunt Damping (압전감쇠를 이용한 압전지능패널의 전달 소음저감 성능)

  • 이중근
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.1
    • /
    • pp.49-57
    • /
    • 2002
  • The possibility of a transmission noise reduction of piezoelectric smart panels using piezoelectric shunt damping is experimentally studied. Piezoelectric smart panel is basically a plate structure on which piezoelectric patch with shunt circuits is mounted and sound absorbing materials are bonded on the surface of the structure. Sound absorbing materials can absorb the sound transmitted at mid frequency region effectively while the use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. To be able to reduce the sound transmission at low panel resonances, piezoelectric damping using the measured electrical impedance model is adopted. Resonant shunt circuit for piezoelectric shunt damping is composed of register and inductor in series, and they are determined by maximizing the dissipated energy throughout the circuit. The transmitted noise reduction performance of smart panels is investigated using an acoustic tunnel. The tunnel is a tube with square crosses section and a loud-speaker is mounted at one side of the tube as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across panels is measured. Noise reduction performance of a smart panels possessing absorbing material and/or air gap shows a good result at mid frequency region but little effect in the resonance frequency. By enabling the piezoelectric shunt damping, noise reduction of 10dB, 8dB is achieved at the resonance frequencise as well. Piezoelectric smart panels incorporating passive method and piezoelectric shunt damping are a promising technology for noise reduction in a broadband frequency.

  • PDF

Histological and Ultrastructural Differentiations of the Neuroepithelial Cells in the Mouse Embryo during Early Neurulation (마우스 초기 신경배형성과정에서 신경상피세포의 조직학적 및 미세구조적 분화)

  • Kim, Yul-A;Chung, Young-Wha
    • Applied Microscopy
    • /
    • v.29 no.1
    • /
    • pp.105-124
    • /
    • 1999
  • Histological and ultrastructural differentiations of the neuroepithelial cells in the mouse embryo during neurulation were observed. The neural plates and grooves consisted of pseudostratified columnar epithelium in the embryonic day (ED) 8 embryo were developed. In the ED 9 embryo, the neural tube was developed in all body length of embryo except both the cephalic and caudal ends. Secondary neurulation was shown at the tail bud of the ED 10 embryo. In the ED 8 embryo, the primitive streak was shown in the posterior end of the embryonic disc. The neuroepithelium, notochord and mesenchyme were well differentiated in the cephalic and cervical portions. In the ED 9 and 10 embryos, the roof plates of neural tubes were constituted of the closing of the surface ectodermal cells in the hindbrain and the neuroepithelial cells in the spinal cord. The floor plate of neural tube were consisted of the low pseudostratified columnar epithelium. The spinal motor nerve fibers were initially differentiated in the ED 10 embryo. According to the electron density of the cell and the differentiation of tell organelles, the neuroepithelial cells in the ED 9 and 10 embryos were classified into three types: dark, intermediate and light types. All types in the ED 9 embryo were observed but the dark cell in the ED 10 embryo was not done. The free ribosomes and polysomes in all neuroepithelial cells were developed. The RER and lipid droplets in the dark cell and the Golgi complex in the intermediate and light cells were observed. Many microfilaments in the cytoplasmic processes of intermediate cell and the microfilaments and microtubules in the light cell processes were observed to be well differentiated.

  • PDF

Analysis of the minimum exposure position according to the additional filtration plate (부가여과판에 따른 최소한의 피폭 위치에 대한 분석)

  • Tae-Ri, Kim;Min-Ji, Kang;Sang-Hee, La;Yun-Jeong, Shin;Tae-Gyeom, Hong;Min-Cheol, Jeon
    • Journal of Advanced Technology Convergence
    • /
    • v.1 no.2
    • /
    • pp.11-17
    • /
    • 2022
  • The purpose is to find out where medical workers can receive the minimum radiation does in clinical. In order to sett RQR standard quality of radiation, put a Al 1.5mm filter(row and column: 10 cm × 10 cm) on X-ray tube. Al 0.9 mm, Cu 0.3 mm, Ni 0.3 mm used as a filter. The Acrylic phantom were set to 13.1 cm, 18.5 cm, 21.1 cm. by the object thickness was different. As a results, when we use Al 0.9 mm, 1853 nSv was the highest numeral. It is a point of anode low 50 cm, when we use 13.1 cm Acrylic phantom. When we use Cu 0.3 mm, 173 nSv was the lowest numeral. It is a point of anode low 150 cm, when we use 13.1 cm Acrylic Phantom. In this study, it was confirmed that the spatial scattering dose decreased as the distance from the X-ray tube increased. It is considered that more studies on the exposure of scattered doses are needed in the future.

A STUDY ON THE MICROBIAL CONTAMINATION OF DENTAL UNIT AND ULTRASONIC SCALER (덴탈유니트의 핸드피스 및 초음파 치석 제거기의 미생물 오염에 관한 연구)

  • Lee, Byung-Moon;Kim, Chang-Whe;Kim, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.64-80
    • /
    • 1998
  • The risk of cross-contamination in dental clinic is very high. Those who are engaged in dental clinic are exposed to various microorganisms in saliva and blood of patient. Potential possibility of cross-contamination of patient to patient, patient to dentist, dentist to laboratory technician always exist, which is important in the view of public health. It is well known that microorganisms may cause cross-contamination by suck-back of microorganisms into the water supply line or air supply line of dental unit and sprayed back into the next patient's oral cavity. The majority of microorganisms coming from dental unit are water microorganisms from the main water supply which have colonized the tube within the units and multiplied in the relatively warm and stagnant conditions. The purpose of this study is to measure the extent of microbial contamination of dental unit and ultrasonic scaler, to evaluate that dental unit water supply is suitable for drinking water, and to assess the effect of flushing on reduction of microbial contamination of dental unit and ultrasonic scaler. In the first experiment, water samples(50ml) from 20 dental units and 10 ultrasonic scalers in Seoul National Univ. Hosp. were tested for the presence of coliform. The samples were filtered by membrane filtration technique.(Microfil system, Millipore Co. U. S. A.) The filter was then placed onto MacConkey agar plate and the plates with filter on it were incubated aerobically at $37^{\circ}C$ for 5 days. The colors and shapes of colonies were examined if those were coliform. To verify the presence of coliform, the colonies were inoculated into phenol red lactose broth and incubated aerobically at $37^{\circ}C$ for 2 days. The fomation of gas was observed. In the second experiment, water samples from 20 handpieces, 10 ultrasonic scalers and 30 A/W syringes after 0, 2, 4, 6 min. flushing respectively were taken. $200{\mu}l$ water samples were spreaded on Brain Heart Infusion agar plate and the plates were incubated aerobically at $37^{\circ}C$ for 5 days. The number of colony was counted. The results obtained were summarized as follows 1. The water from dental unit and ultrasonic scaler was not suitable for drinking water. 2. No coliform was founded in dental unit and ultrasonic scaler water supply. 3. The number of colony of dental unit and ultrasonic scaler was highest in the group of o min. flushing(p<0.05). 4. There was no statistically significant difference in the extent of microbial contamination among handpiece, ultrasonic scaler and A/W syringe (p>0.05). 5. The number of colony was lowest in the group of 4 min. flushing, but there was no statistically significant difference among 2, 4, 6 min. flushing groups.(p>0.05) 6. It is recommended to flush dental unit water line for 4 min. after use on each patient.

  • PDF

Evaluation of Forming Performance of Cold Rolled Steel Pipes & Tubes for Building Structure (건축구조용 냉간성형 강관의 가공성능 평가)

  • Im, Sung Woo;Choi, Kwang;Chang, In Hwa
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.1 s.68
    • /
    • pp.33-42
    • /
    • 2004
  • Making use of SN steel in the building structure should be a prerequisite to adopt the design strength of said steel. As a preceding study, the material properties of STKN400B/490B tubes and SPAP235/325 and SPAR295 square pipes manufactured using SN400B/490B plates were evaluated. Compared with the yield and ultimate strengths of SN400B/490B plates, those of STKN400B/490B tubes increase. Nonetheless, the yield and ultimate strengths of STKN400B/490B tubes satisfied the design codes of STKN400B/490B tubes even though the tubes were fabricated via roll bending or press forming. On the other hand, the yield and ultimate strengths at the edges of SPAP235/325 square pipes did not satisfy the design codes based on the values at the sides. The maximum tensile and compressive residual stresses at the SN490B tube were equal to and 40% of the yield strength of the SN490B plate, respectively, In the case of the SPAP325 square pipe, both the maximum tensile and compressive residual stresses were 80% of the yield strength of the SN490B plate. The axial compressive loaded column test results snowed that the buckling strengths were not very different regardless of the mode of fabrication of STKN490B tunes. i.e., through roll bending or press forming. On the other hand, the buckling strength of the SPAP325 square pipe was higher than that of the built-up square pipe.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

Study on the Cyclic Seismic Testing of U-shape Hybrid Composite Beam-to-Composite Column Connections (신형상 U형 하이브리드 합성보와 기둥 접합부의 내진성능에 관한 연구)

  • Kim, Sung Bae;Kim, Sang Seup;Ryu, Deog Su
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.1
    • /
    • pp.47-59
    • /
    • 2013
  • This study that is a successive secondary study right after the primary bending strength test of a new form of U-shape hybrid composite beam is a cyclic seismic test of U-shape hybrid composite beam and column conncetion. Three specimens are built for the variables which are kinds of columns, depth of beam, continuity or discontinuity of upper plate of beam, and a number of steel bars of end-beam. Kinds of columns are a reinforcement concrete column and a ACT column of CFT shape, and beam depth are 300, and 500 mm. Detail of connection is bolt connection with using a short bracket that is commonly use. As the result, deformability of 2~4% is ensured the floor displacement angle. If it is the negative moment, the maximum moment shows that its capacity is above the nominal moment.

Evaluation of the Filling Sodium States Inside the Fuel rod of Sodium-Cooled Fast Reactor by Optimized Spatial Resolution in Medical Digital Radiographic Images (의료용 디지털방사선영상의 공간분해능 최적화에 의한 소듐냉각고속로 연료봉 내부의 소듐 충전상태 평가)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.117-124
    • /
    • 2016
  • The purpose of this study was tried to evaluate the filling sodium states inside the fuel rod of sodium-cooled fast reactor by digital medical X-ray. We used the diagnostic X-ray generators in digital radiography (DR). This study have found the optimal conditions by changing the effective focal spot size of X-ray tube and post-processing of the DR method with a tungsten edge plate in order to ensure excellent sharpness At this time, the sharpness and resolution were evaluated using the MTF (modulation transfer function). As a result, this study obtained a spatial resolution of 3.871 lp/mm (0.1 MTF), 3.290 lp/mm (0.5 MTF) when implemented the contrast strengthen post-processing in small focal spot. In this research, the result is able to evaluate the level of sodium inside the fuel rod by using the diagnostic X-ray generators in medical digital radiographic images.

화학적 구조 설계를 통한 수계 Cu-In-S 잉크와 액상셀렌화 법의 개발을 통한 고효율의 CISSe 태양전지 제작

  • O, Yun-Jeong;Yang, U-Seok;Kim, Ji-Min;Mun, Ju-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.428-428
    • /
    • 2016
  • Copper indium sulfide (selenide) (CuIn(S,Se)2,CISSe)는 1.0~1.5 eV의 Direct band gap과 105 cm-1이 넘는 큰 광 흡수 계수를 가지고 있어 박막 태양전지의 흡수층으로써 연구되어 왔다. 최근 대량생산 및 저가 공정에 용이하다는 측면에서 용액 공정 기반 CISSe 태양전지 연구가 크게 주목 받고 있다. 용액공정 기반 중 하이드라진을 사용 한 경우 매우 높은 효율을 기록하였으나, 하이드라진 자체의 유독성과 폭발성 때문에 분위기 제어가 필요하고 여전히 저가화 및 대면적 제작에 한계가 있다. 따라서 알코올 솔젤 기반 CISSe 태양전지 제작 연구가 많이 진행되었으나, 결정립 성장 및 칼코겐 원자를 공급하기 위해 불가피하게 황화/셀렌화 후속 열처리 공정을 요구한다. 후속 열처리 공정은 폭발성의 황화수소/황화셀레늄 기체 분위기 제어와 고가의 장비를 필요로 한다. 본 연구에서는 매우 안정적이며 저가 용매인 물과 아민계 첨가제를 이용하여 Cu, In 전구체와 S, Se 이 포함된 Cu-In-S 잉크와 Se잉크를 제작하였다. 잉크 내에 S, Se을 첨가 함으로써 추가적인 후속공정 없이 비활성 가스 분위기에서 고품질의 CISSe 박막 제작을 가능케 하였다. 또한 Se 잉크 증착 횟수에 따른 결정 구조, 광학적 성질의 차이에 주목하였다. 따라서 수계 잉크를 대기 중에서 스핀코팅으로 박막을 제작한 후, Hot plate에서 건조하여 균일한 박막을 제조하고, 제작된 박막을 tube furnace에서 환원 분위기 및 비활성 가스 분위기에서 열처리 진행하여 $1.3{\mu}m$ 두께의 고품질의 CISSe 흡수층을 제작하였다. 이러한 흡수층에 대해 XRD, SEM, EDS 분석을 진행하여, 결정성, 미세구조, 및 조성을 확인하였으며, 제작된 흡수층 위에 버퍼층/투명전극층을 차례로 증착하여 CISSe 태양전지를 제작하여 셀 성능 및 양자 효율 특성을 파악하였다. 또한 액상 Raman 분석을 통해 결정립 성장 과정 메커니즘을 제시하였다.

  • PDF

The Expression Patterns of Cdc25A, Cdc25B, Sox2 and Mnb in Central Nervous System in Early Chicken Embryos

  • Zhang, Hui;Qin, Junhui;Cao, Jingjing;Hei, Nainan;Xu, Chunsheng;Yang, Ping;Liu, Haili;Chu, Xiaohong;Bao, Huijun;Chen, Qiusheng
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.6
    • /
    • pp.781-787
    • /
    • 2009
  • The sense and antisense digoxigenin-labeled RNA probes of four genes, Cdc25A, Cdc25B, Sox2 and Mnb, were produced by using SP6 and T7 RNA polymerases, respectively, and in vitro transcription. Expression patterns of the four genes were detected by in situ hybridization in HH (Hamburger and Hamilton) stage 10 chick embryos. In general, expression patterns of the four genes were similar. mRNA of the four genes was mostly restricted to the entire CNS (central nervous system). All were confined to an identical region, neural tube, neural groove and caudal neural plate, corresponding to the notochord or spinal cord, but there was some distinction in specific region or in concentration, for example in somites. The overlap in expression at the same developmental stage in the CNS suggests that the four genes may be functional similar or related in CNS development. Expression patterns of the four genes support specific roles of these regulators in the developing CNS.