• Title/Summary/Keyword: triple ion

Search Result 53, Processing Time 0.03 seconds

Control of Defect Produced in a Retrograde Triple Well Using MeV Ion Implantation (MeV 이온주입에 의한 Retrograde Triple-well 형성시 발생하는 결합제어)

  • 정희석;고무순;김대영;류한권;노재상
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.17-20
    • /
    • 2000
  • This study is about a retrograde triple well employed in the Cell tr. of next DRAM and flash memory. triple well structure is formed deep n-well under the light p-well using MeV ion implantation. MeV P implanted deep n-well was observed to show greatly improved characteristics of electrical isolation and soft error. Junction leakage current, however, showed a critical behavior as a function of implantation and annealing conditions. {311} defects were observed to be responsible for the leakage current. {311} defects were generated near the R$\sub$p/ (projected range) region and grown upward to the surface during annealing. This is study on the defect behavior in device region as a function of implantation and annealing conditions.

  • PDF

Control of Defect Produced in a Retrograde Triple Well Using MeV Ion Implantation (MeV 이온주입에 의한 Retrograde Triple-well 형성시 발생하는 결함제어)

  • 정희석;고무순;김대영;류한권;노재상
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.17-20
    • /
    • 2000
  • This study is about a retrograde triple well employed in the Cell tr. of next DRAM and flash memory. Triple well structure is formed deep n-well under the light p-well using MeV ion implantation. MeV P implanted deep n-well was observed to show greatly improved characteristics of electrical isolation and soft error. Junction leakage current, however, showed a critical behavior as a function of implantation and annealing conditions. {311} defects were observed to be responsible for the leakage current. {311} defects were generated near the R$\_$p/ (Projected range) region and grown upward to the surface during annealing. This is study on the defect behavior in device region as a function of implantation and annealing conditions.

  • PDF

An analysis of latch-u immunity on triple-well and twin-well architecgure using a high energy ion implanttion (고에너지 이온주입에 의한 triple-well과 twin-well 구조에서 래치업 예방을 위한 해석)

  • 홍성표;전현성;김중연;노병규;조재영;오환술
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.445-448
    • /
    • 1998
  • 본 논문은 triple-well과 twin-well에서의 고에너지 이온주입 에너지와 도즈량 변화에 따른 래치업 특성을 비교하였다. 공정시뮬레이터인 ATHENA로 소자를 제작하고 도핑프로파일 형태와 구조를 조사한 후, 래치업 특성은 소자 시뮬레이터인 ATLAS를 이용하였다. triple-well 공정이 마스크 스텝수를 줄이고, 이온주입 후 열처리시간을 단축하며 별도의 열처리 공정없이 도핑르로파일을 넓은 형태로 분포시켜 래치업 면역특성이 매우 좋은 결과를 얻었다.

  • PDF

Li+ and Li+I-Li+ ions Solvated by 1,4-dioxane: An ion Mobility Spectrometry-Mass Spectrometry Study

  • Choi, Yunseop;Ji, Inyong;Seo, Jongcheol
    • Mass Spectrometry Letters
    • /
    • v.12 no.4
    • /
    • pp.152-158
    • /
    • 2021
  • Electrospray ionization (ESI) and ion mobility spectrometry-mass spectrometry (IMS-MS) were employed to investigate the solvated structures of ionic species in the lithium iodide electrolyte solution in the gas phase. The Li+I-Li+ triple ion and single standalone Li+ ions solvated by 1,4-dioxane were successfully generated and observed by ESI-MS under the influence of dioxane vapor at the inlet region. Under the present experimental condition, (1,4-dioxane)m·Li+ complex ions (m = 1, 2, and 3) and a (1,4-dioxane)·Li+I-Li+ complex ion were observed, which were further examined by IMS to investigate their structures. The presence of multiple structural isomers was confirmed, which accounts for the endothermic conformational transition of 1,4-dioxane from a chair to a boat to achieve bidentate O-donor binding to Li+ and Li+I-Li+. Further structural details critical for the ion-solvent interactions were also examined and discussed with the help of density functional theory calculations.

Simultaneous Analyses for Trace Multi-Odorous and Volatile Organic Compounds in Gas using a Triple-bed Adsorbent Tube (Triple-bed Adsorbent Tube를 이용한 가스상 극미량 복합 악취 및 휘발성 유기화합물의 동시 분석)

  • Seo, Yong Soo;Lee, Jea Keun
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.244-252
    • /
    • 2010
  • The objective of this study is to assess feasibility of simultaneous analysis for trace multi-components odorous and volatile organic compounds using a Triple-bed adsorbent tube with a thermal desorber and GC-MS. Triple-bed adsorbent tube is 3 bed packed Tenax-TA with small amount of Carbopack B and Carbosieve SIII in order of adsorption strength in a tube. The operating conditions of GC-MS was possibly able to and effectively detect high volatile and low molecular weight compounds at the mass range of 20~350 m/z using a below impurity 1ppm of Helium carrier gas, of which quantitatively analyzed by target ion extracts. According to the experiment, $C_1{\sim}C_5$ of 14 components; sulfur containing compounds(2), ketones(2), alcohols(4) and aldehydes(6) were simultaneously analyzed with recoveries of 99%, and good repeatability and linearity. High volatile and low molecular weight compounds such as methyl alcohol and acetaldehyde can be safely quantified with high recovery at a condition of 50mL/min of flow rate, below 2L of adsorption volume, and 45% of relative humidity. Target ion extract can also simultaneously quantify multicomponents with odorous and volatile organic compounds in an occasion of piled up two peaks.

A Study on Improvement Latch-up immunity and Triple Well formation in Deep Submicron CMOS devices (Deep Submicron급 CMOS 디바이스에서 Triple Well 형성과 래치업 면역 향상에 관한 연구)

  • 홍성표;전현성;강효영;윤석범;오환술
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.9
    • /
    • pp.54-61
    • /
    • 1998
  • A new Triple well structure is proposed for improved latch-up immunity at deep submicron CMOS device. Optimum latch-up immunity process condition is established and analyzed with varying ion implantation energy and amount of dose and also compared conventional twin well structure. Doping profile and structure are investigated using ATHENA which is process simulator, and then latch-up current is calculated using ATLAS which is device simulator. Two types of different process are affected by latch-up characteristics and shape of doping profiles. Finally, we obtained the best latch-up immunity with 2.5[mA/${\mu}{m}$] trigger current using 2.5 MeV implantation energy and 1$\times$10$^{14}$ [cm$^{-2}$ ] dose at p-well

  • PDF

Optimization of Reflectron for Kinetic and Mechanistic Studies with Multiplexed Multiple Tandem (MSn) Time-of-flight Mass Spectrometry

  • Bae, Yong-Jin;Yoon, So-Hee;Moon, Jeong-Hee;Kim, Myung-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.1
    • /
    • pp.92-99
    • /
    • 2010
  • Photoexcitation of a precursor ion inside a cell floated at high voltage installed in a tandem time-of-flight (TOF) mass spectrometer provides triple tandem mass spectrometric information and allows kinetic and mechanistic studies. In this work, the factors affecting, or downgrading, the performance of the technique were identified. Ion-optical and computational analyses showed that an optimum instrument could be designed by utilizing a reflectron with linear-plus-quadratic potential inside. Theoretical predictions were confirmed by tests with instruments built with different ion-optical layout. With optimized instruments, masses of intermediate ions in the consecutive dissociation of a precursor ion could be determined with the maximum error of $\pm5$ Da. We also observed excellent agreement in dynamical parameters (critical energy and entropy) for the dissociation of a model peptide ion determined by instruments with different ion-optical layout operated under optimum conditions. This suggests that these parameters can be determined reliably by the kinetic method developed previously when properly designed and operated tandem TOF instruments are used.

Studies on the Adsorption Modeling of Cationic Heavy Metals(Pb, Cd) by the Surface Complexation Model (Surface Complexation Model을 이용한 양이온 중금속(Pb, Cd) 흡착반응의 모델화 연구)

  • 신용일;박상원
    • Journal of Environmental Science International
    • /
    • v.8 no.2
    • /
    • pp.211-219
    • /
    • 1999
  • Surface complexation models(SCMs) have been performed to predict metal ion adsorption behavior onto the mineral surface. Application of SCMs, however, requires a self-consistent approach to determine model parameter values. In this paper, in order to determine the metal ion adsorption parameters for the triple layer model(TLM) version of the SCM, we used the zeta potential data for Zeolite and Kaolinite, and the metal ion adsorption data for Pb(II) and Cd(II). Fitting parameters determined for the modeling were as follows ; total site concentration, site density, specific surface area, surface acidity constants, etc. Zeta potential as a new approach other than the acidic-alkalimetric titration method was adopted for simulation of adsorption phenomena. Some fitting parameters were determined by the trial and error method. Modeling approach was successful in quantitatively simulating adsorption behavior under various geochemical conditions.

  • PDF

TRIFLE DIFFERENCE APPROACH TO LOW EARTH ORBITER PRECISION ORBIT DETERMINATION

  • Kwon, Jay-Hyoun;Grejner brzezinska, Dorota-A.;Yom, Jae-Hong;Lee, Dong-Cheon
    • Journal of Astronomy and Space Sciences
    • /
    • v.20 no.1
    • /
    • pp.1-10
    • /
    • 2003
  • A precise kinematic orbit determination (P-KOD) procedure for Low Earth Orbiter(LEO) using the GPS ion-free triple differenced carrier phases is presented. Because the triple differenced observables provide only relative information, the first epoch's positions of the orbit should be held fixed. Then, both forward and backward filtering was executed to mitigate the effect of biases of the first epoch's position. p-KOD utilizes the precise GPS orbits and ground stations data from International GPS Service (IGS) so that the only unknown parameters to be solved are positions of the satellite at each epoch. Currently, the 3-D accuracy off-KOD applied to CHAMP (CHAllenging Min-isatellite Payload) shows better than 35 cm compared to the published rapid scientific orbit (RSO) solution from GFZ (GeoForschungsZentrum Potsdam). The data screening for cycle slips is a particularly challenging procedure for LEO, which moves very fast in the middle of the ionospheric layer. It was found that data screening using SNR (signal to noise ratio) generates best results based on the residual analysis using RSO. It is expected that much better accuracy are achievable with refined prescreening procedure and optimized geometry of the satellites and ground stations.