• Title/Summary/Keyword: treatment wetland

Search Result 220, Processing Time 0.02 seconds

Livestock Wastewater Treatment by a Constructed Wetland (인공습지를 이용한 축산폐수의 처리)

  • Park, Jae-hong;Choi, Eui-so;Cho, Il-hyoung
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.2
    • /
    • pp.157-162
    • /
    • 2004
  • Constructed wetlands are considered as an important tool for wastewater treatment, wastewater management and flooding control. In addition, one of the most promising technologies for application in many countries seems to be constructed wetlands, due to their properties such as utilization of natural processes, simple construction, operation and maintenance, process stability, cost effectiveness, etc. This study considered possibility of treatment of livestock wastewater using a constructed wetland. The removal efficiencies of $COD_{cr}$, TOC, TN, TP, SS, and color were 97.6%, 96.6%, 97.0%, 96.7%, 99.0%, and 85.6%, respectively. In particular, SS was completely removed. However, $Cl^{-}$ concentration of the constructed wetland effluent was higher than that in influent. In conclusion, constructed wetlands could be applied to livestock wastewater treatment if $Cl^{-}$ would be properly treated. Further, it needs time for stabilization to reduce the pollutants which were accumulated in soil.

Application of the Hybrid Constructed Wetland for a Reuse of the Effluent from Bio-industrial Wastewater Treatment Plant (바이오산업폐수처리수의 재이용을 위한 hybrid 인공습지 시스템의 적용가능성 연구)

  • Shin, Jae-Suk;Kim, Sung-Chul;Cho, Kwang-Ju;Choi, Choong-Ho;Choi, In-Wook;Park, Jeong-Ja;Park, Goo-Hyeon
    • Journal of Wetlands Research
    • /
    • v.11 no.1
    • /
    • pp.115-121
    • /
    • 2009
  • The hybrid constructed wetland(HCW) as tertiary treatment process of a bio industrial wastewater treatment plant was employed to estimate applications for the reuse of final effluent. Raw wastewater was sequently treated through chemical and biological treatment processes and the biologically treated water was flowed into the HCW. The HCW system was composed of two constructed wetlands connected in series; The one is the aerobic constructed wetland with natural air draft system whose driving force for air supply was the difference between the temperature of the air inside the wetland and the ambient air, and the other is the anaerobic/anoxic constructed wetland. Average influent concentrations of BOD, SS, T-N and T-P in the HCW were 53mg/L, 48mg/L, 34mg/L and 3mg/L, respectively. After being treated at HCW, final effluent concentrations of BOD, SS, T-N and T-P were 2.3mg/L, 1.2mg/L, 7.95mg/L and 0.83mg/L, respectively. Referring to a reuse standard for a sewage wastewater, final effluent could sufficiently be reuse as landscaping, washing or agriculture water. HCW system with the aerobic/anaerobic combined constructed wetland could be achieved a high removal efficiency because each constructed wetland was functionalized to be removed efficiently organics, nitrogen and phosphorus. HCW system could be estimated to be successful application as tertiary treatment process of a various industrial and municipal wastewater.

  • PDF

A Study on the Development of Performance Evaluation Method for the Stormwater Treatment Wetland (비점오염관리를 위한 강우유출수 처리습지의 성능평가방법 개발)

  • Kim, Young Ryun;Kim, Sang Dan;Lee, Suk Mo;Sung, Kijun;Song, Kyo Ook;Son, Min Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.3
    • /
    • pp.354-364
    • /
    • 2013
  • The performance of the stormwater wetlands can be significantly influenced by antecedent stormwater in storage at the commencement of a stormevent. As inflows are intermittent and stochastic in nature, the evaluation of the treatment efficiency of a stormwater wetland should be considered by runoff capture and water treatment characteristics during interevent periods. In this study, analytical probabilistic model is applied to identity runoff capture rate and treatment efficiency of the stormwater wetland. To achieve this, continuous rainfall data recorded in Busan for 31 years has been analyzed to derive the runoff capture rate, and 1st order kinetic decay constants ($k_V$, 1/d) are calculated from regression analysis to identify pollutants removal during interevent periods. The results show that about 60.9% of annual average runoff is captured through the stormwater wetland. The annual average treatment efficiencies of SS, BOD, COD, TN and TP is about 11.4, 8.9, 9.8, 4.3 and 9.6%, respectively. The analytical model has been compared with the numerical model and it shows that analytical model is valid. Performance evaluation methods developed in this study has the advantages of considering characteristics of rainfall-runoff, facility type and pollutant removal.

Application of Free Water Surface Constructed Wetland for NPS Control in Livestock Watershed Area (축산단지 비점오염물질 저감을 위한 자유수면형 인공습지 적용)

  • Lee, Jeong-Yong;Kang, Chang-Guk;Lee, So-Young;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.13 no.3
    • /
    • pp.481-488
    • /
    • 2011
  • Various development activities have lead to the destruction of the ecosystem such as natural wetlands. In order to protect these natural wetlands, the Ministry of Environment (MOE) in Korea enacted the Wetland Conservation Act in 1999 and designated protected areas for wetland conservation. The MOE adapted the use of Best Management Practices (BMP) such as retention ponds and constructed wetlands to treat the polluted water before entering the water system. One of these projects was a free-water surface flow (FWS) constructed wetland built as a secondary treatment unit for piggery wastewater effluent coming from a livestock wastewater treatment facility. Water quality monitoring for the constructed wetland was conducted during rainfall events. The results showed that the average removal efficiencies of TSS, BOD, TN, TP were 86, 60, 45, 70%, respectively. It was observed that the removal efficiency of particulate matter and phosphorus was high compared to nitrogen. Therefore, a longer hydraulic retention time was needed in order to improve the treatment efficiency of nitrogen. The results of this study can contribute to the wetland design, operation and maintenance of constructed wetlands.

A Pilot-Scale Study of Multiple Stage of Constructed Wetland Treatment System and Modeling for Nutrient Removal (Pilot 규모 연속배열형 인공습지의 영양염류 제거효능 규명 및 평가모델 연구)

  • Choi, Seung Il;Iamchaturapatr, Janjit;Rhee, Jae Seong
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.781-788
    • /
    • 2010
  • A pilot study was performed to examine the feasibility of multiple stage of constructed wetland (CW) for nutrient removal. The system is composed of six wetland cells connected with water-ways. The hydraulic of wetland cells is designed as free water surface flow. The treatment capacity was $25m^3d^{-1}$ at HRT of about one day for each cell. The magnitude of nutrient removal was related with the length of wetlands and plant density. Total N and P removal rates were 1353 and $246mg\;m^{-2}d^{-1}$ respectively. The pilot-scale reactor was model as continuous flow system containing contribution of CSTR and PFR typed-reactors. The $k-C^*$ model equation was applied to predict N and P reduction. The result indicated the equation was well guided to estimate reduction of $NO_3-N$ and $PO_4-P$.

A Study of Design Conditions for Decision Area of Constructed Wetland to treat Nonpoint Source Pollution from Agricultural Area (농촌유역 비점오염원처리를 위한 적정 인공습지 규모결정에 관한 연구(지역환경 \circled1))

  • 장정렬;박종민;권순국;윤경섭
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.490-499
    • /
    • 2000
  • Several studies on development of water quality treatment systems by wetlands are on going because of their benefits of low construction cost and high efficiency of waste water treatment. The objectives of this study were to review the necessary contents of survey and design factors for constructing constructed wetlands and to examine the required wetland area to treat non-point source pollution through case studies. The measurement of water quality and quantity in precipitation period is needed to analyse the inflow characteristics of the non-point pollution and to determine the amount of design flow. The design inflow for constructing constructed wetland was determined to the total runoff from 30mm of daily rainfall in the AMC(III) condition of the SCS method and is similar 70% of the annual mean runoff. The natural type wetland system with 0.1m of water depth and 5 hours of detention time was applied. From the results of the case studies, 70% of inflow could be treated and 1∼3% of wetland area of the total basin is needed.

  • PDF

Use of biochar to enhance constructed wetland performance in wastewater reclamation

  • Gupta, Prabuddha;Ann, Tae-woong;Lee, Seung-Mok
    • Environmental Engineering Research
    • /
    • v.21 no.1
    • /
    • pp.36-44
    • /
    • 2016
  • Constructed wetlands are established efficient technologies and provide sustainable solution for wastewater treatment. Similarly, biochar, which is an organic material, produced by means of pyrolysis, offers simple and low cost techniques to treat water and reduce carbon footprint. Combining both of these technologies can greatly augment the efficiency of the system. The objective of this study was to evaluate the efficiency of constructed wetlands by using biochar as media. Horizontal wetland beds with dimension ($1m{\times}0.33m{\times}0.3m$) were prepared using gravels and biochar, and cultivated with the Canna species. Synthetic wastewater was passed through these beds with average flow rate of $1.2{\times}10^{-7}m^3/sec$ achieving a retention time of three days. Pollutant removal performance was compared between the controlled and experimental wetland beds. This study reveals that the wetland with biochar were more efficient as compared to the wetland with gravels alone with average removal rate of 91.3% COD, 58.3% TN, 58.3% $NH_3$, 92% $NO_3-N$, 79.5% TP, and 67.7% $PO_4$.

Analysis of Efficiency of Artificial Wetland for Waste Water Treatment Past Six Year Operation (6년 동안 운영한 인공습지의 처리효율 분석)

  • Hur, Jai-Kyou;Nam, Jong-Hyun;Kim, Yong-Jeon;Kim, In-Seon;Choi, Kyoung-Suk;Choi, Seung-Ik;Ahn, Tae-Seok
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.10 no.3
    • /
    • pp.1-7
    • /
    • 2007
  • For waste water treatment, artificial wetland was constructed in 1998. The size of artificial wetland is 20m${\times}$200m, with sand and gravel as media and Phragmites japonica was implanted. The removal rate of BOD, TN, and TP were 86%, 33% and 25% from June 2004 to November 2005 respectively, while those were 88%, 38% and 55% in 1999. Organic materials and nitrogen compounds are still effectively removed, after 6 years of construction, but the removal efficiency of phosphorus compounds is reduced. So for sustaining of artificial wetland as waste water treatment system, the removal efficiency of phosphorus compounds must be elevated.

Wetland Performance for Wastewater Treatment in Growing and Winter Seasons (생장기와 동절기의 인공습지 오수처리 성능)

  • 윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.4
    • /
    • pp.37-46
    • /
    • 1999
  • Field experimnet of constructed wetland for rural wastewater treatment was performed from July 1998 to April 1999 including winter to examine the seasonal effect on the wetland performance. The system worked without freezing even under $-10^{\circ}C$ of air temperature as long as watewater was flowing. BOD removal rates varied in similar pattern as the air temperature, and winter performance was relatively lower than that in the growing season. However, removing performance during winter was still significant, and BOD removal rates were almost the the same as in the growing season. SS removal rate was relativelyless affected by temmperature, but lower decay rate during the winter can result in accumulation of the SS in the system, which releases constituents in the next spring and can affect whole system performance. The winter removal rates of nutrients like T-N and T-P were decreased about half compared to the growing season and low temperature. To maintain stabilized wetland performanced including winter time, supplying minimum heating for plants could be an alternative in field application. Experimental data was compared with NADB(North Americal Wetlands for Water Quality treatment database), and general performance of the system was within the reasonable range. The pollutant loading and effluent concentration of the experimented system were in high margin. Base on the experiment and databases, the required effluent water quality could be achieved if loading rate adjusted as ilulstrated in the database.

  • PDF

Water Treatment Characteristics by Const ucted Wetland with Different Vegetation - Open Water Arrangements (식생습지와 개방수역의 배열에 따른 인공습지의 수처리 특성)

  • Jang, Jeong-Ryeol;Choi, Sun-Hwa;Kwun, Soon-Kuk
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.1
    • /
    • pp.122-130
    • /
    • 2007
  • This study was conducted to evaluate water treatment characteristics according to vegetated wetland(V) and open water(O) arrangements in free water surface constructed wetland. Three pilot-scale wetlands, V-V, O-V and V-O, were built and operated. $BOD_5$ was a slightly reduced at all the arrangements because the influent concentration was so low as background concentration of constructed wetlands. While T-N and T-P removal efficiency showed higher than 50% for all cases. The O-V arrangement showed the highest removal efficiency: 20% for $BOD_5$, 56% for SS, 59% for T-N and 72% for T-P. Effluent concentration of the O-V were significantly low compared with those from the V-O. O-V arrangement would be beneficial in the light of pollutant removal efficiency as well as construction cost.