• 제목/요약/키워드: tray

Search Result 580, Processing Time 0.02 seconds

Implant overdenture impressions using a dynamic impression concept

  • Lee, Byung-Kil;Park, Sang-Hun;Lee, Cheong-Hee;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.66-70
    • /
    • 2014
  • A dynamic impression is a functional impression that records the functional movement of the patient's own muscle and muscle attachment. This process reduces the number of random factors. This article describes a method for making a special tray using a dynamic impression concept that was made from provisional dentures used for implant healing. The individual tray is used to make a wash-impression to record the features of the mucosa in detail. The main advantage of this technique is that it provides a functional relationship of the implant components to the supporting tissues without overextension because provisional denture had been used for 2 months and the border length of individual tray was nearly the same as that of provisional denture. The delivery of the prosthesis constructed using this impression technique is time-saving because there is no need for border molding and there are fewer post-insertion appliance adjustments.

An alternative impression technique based on McLean's functional impression concept (McLean의 기능 인상법에 기반한 새로운 인상채득법)

  • Choi, Hyun-Suk;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.32-37
    • /
    • 2017
  • In this case report, an alternative impression technique for fabricating removable partial dentures was used in a patient with very few remaining teeth. In this technique, an individual tray was made on the cast, which was made by relining interim denture and taking overimpression with irreversible hydrocolloid according to McLean's functional impression concept. This method showed the following advantages: the no need for border molding with modeling compound, time saving for denture impression without overextension and accurate seating of the individual tray.

Studies on Oyster Mushroom (Pleurotus ostreatus) Packed in Various Environmental Friendly Trays (환경 친화적 포장재를 이용한 느타리버섯의 저장성 연구)

  • 신동화;안용선;강진하;오승원
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.29 no.1
    • /
    • pp.85-92
    • /
    • 2000
  • This study was carried out to storage of Pleurotus ostreatus packed in various trays made by different matrials-expanded polystyrene (EPS), rice straw pulp(RP), and RP trays coated with starch, carboxyl methyl cellulose (CMC), polyacrylamide (PAM), alkylketen dimer (AKD), rosin size (RS) and polyethylene glycol (PEG) at 8~1$0^{\circ}C$ and 70~80% relative hymidity for 6 days. At 6 days storage, weight increase of RP and CMC tray was lower (p<0.05) than those of others and the weight of oyster mushroom packed in RP, CMC and AKD tray decreased lower(p<0.05) than those of others. Carbon dioxide contents in trays were increased from 0.5% to 5.5%~8.6% within 1 day storage. Oxygen contents in trays were sharply decreased from 20% to 0.8%~8.2% within 1 day storage. Lightness of oyster mushroom increased all trays. Off flavor appeared stronly in oyster mushroom packed in EPS, AKD and PEG during storage, but was not detected in mushroom packed in starch and CMC until 4 days storage.

  • PDF

Drum Type Auto Seeding System for Automatic Speed Control System (속도 자동 제어 기능을 구비한 드럼식 자동 파종 시스템)

  • Kim, Song-Hyun;Kim, Hyun-Soo;Oh, Chang-Jun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.512-513
    • /
    • 2017
  • In this paper, an automatic sowing system which arranges the seeds gathered using inhaling technique, on the upper part of cells in trays, is developed to improve the sowing efficiency. In the system, the seeds in inhaled into the vacuum drum, then the seeds are exhausted and arranged on the rotating tray, resulting in rapid sowing system. Also, the velocity control algorithm for the conveyor belt transporting tray is developed to compensate the velocity error generated while the belt is carrying the tray. The velocity control algorithm controls the pulses applying to the stepper motor rotating the drum.

  • PDF

Measurement of Flow Characteristics of Digester Installed Tray Motioned Mixer by Using Radiotracer (방사성추적자를 이용한 수직교반형 소화조의 유동 특성 측정)

  • Moon, Jinho;Park, Jang Guen;Kang, Munhu;Jung, Sung-Hee
    • Journal of Radiation Industry
    • /
    • v.9 no.3
    • /
    • pp.131-135
    • /
    • 2015
  • The flow characteristics of fluid were measured using radioactive tracer in pilot scale digester with tray motion mixer. In consideration of the detection volume of the detector and the size of the digester, 20 detectors were installed in the digester. The radioactive tracer eluted 8 mCi of $^{68}Ga$ from $^{68}Ge/^{68}Ga$ generator was injected into the digester bottom. After radiotracer injection, the flow pattern was measured on the basis of the initial movement of the tracer until its diffusion completely. Most of tracer moved to the wall along the bottom of the digester, and then rose along the wall. The other tracer moved up along the mixer, and then moved to the wall direction along the surface.

Development and Working Efficiency of Supporting Program for the Parametric Electrical Outfit Production Design of Offshore Plant Based on PML (PML 기반 파라메트릭 해양플랜트 전장생산설계 지원 프로그램 개발 및 업무 효율성 연구)

  • Kim, Hyun-Cheol;Kim, Jong-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.3
    • /
    • pp.205-213
    • /
    • 2019
  • Recently, because of the global recession of the offshore plant industry and low-cost orders, there has been increasing interest in strengthening the competitiveness of domestic companies for the design and production technologies of offshore plants. However, in the offshore plant design field, the Plant Design Management System (PDMS), which is a 3D CAD program for plant layout developed by AVEVA Marine, is already commonly used as offshore plant design software and widely used in large domestic shipyards and cooperative design companies. Under this background, we have been thinking about ways to design better with the existing software. In this study, we developed a parametric design program to maximize the efficiency and reduce the working time for offshore plant electrical outfit production design based on the Programmable Macro Language (PML) of PDMS. We also examined its performance. By applying the developed program to the offshore plant module selected as an application example, it was confirmed that a 50% improvement in the work efficiency of cable tray design could be obtained compared with the existing method, with work efficiency improvements of 80% or more in other field design work.

Numerical study to reproduce a real cable tray fire event in a nuclear power plant

  • Jaiho Lee ;Byeongjun Kim;Yong Hun Jung;Sangkyu Lee;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1571-1584
    • /
    • 2023
  • In this study, a numerical analysis was performed as part of an international joint research project to reproduce a real cable tray fire that occurred in the heater bay area of the turbine building of a nuclear power plant. A sensitivity analysis was performed on various input parameters to derive results consistent with the sprinkler activation time obtained from the fire event analysis. For all sensitive parameters, the normalized sprinkler activation time correlated well with the power function of the normalized sprinkler height. A correlation equation was developed to identify the sprinkler activation time at any location when determining the slope or fire growth rate under the conditions assuming a linear or t-squared heat release rate (HRR) time curve. Various cable fire growth assumptions were used to determine which assumption was better to provide the prediction coincident with the information given from the fire event analysis in terms of the sprinkler activation time and total energy generated from cables damaged by fire. In the comprehensive analysis of all the sensitive parameters, the standard deviation of the input parameters increased as the sprinkler height decreased. Within the range of the sensitivity parameter values given in this study, when considering all sprinkler heights, the standard deviation of the cable model change was the largest and that of the overhang position change was the smallest.

Effect of Different Bottom Seats in Seed Tray on Seedling Growth of Rice (벼 육묘상자 깔판종류가 묘생육에 미치는 영향)

  • Jung, Byung Won;Sohn, Jae Keun
    • Current Research on Agriculture and Life Sciences
    • /
    • v.19
    • /
    • pp.23-29
    • /
    • 2001
  • This study was carried out to develop a seedling raising method without nursery soils in automatic raising facility of rice seedlings for machine transplanting. Pre-germinated seeds were sowed on the seed trays with three different seats such as paper seat, corrugated board, and polyethylene film instead of nursery soils. The growth characteristics of the seedlings for 20 days after sowing were compared with that of a conventional standard raising method with nursery soils. There was no difference in plant height of 10-day old seedlings among the different nursery methods, but the plant height of seedlings grown for 15 days after sowing in the trays with fivefold newspaper and nursery soils was significantly taller than those on other nursery conditions. Dry weight of seedlings grown in the tray with fivefold newspaper bottom was heavier than those in nursery trays with a corrugated board and a piece of polyethylene film. The seedlings grown in a nursery tray with fivefold newspaper showed better seedling quality and root-mat formation compared with the other nursery trays. This result suggests that the healthy seedlings for machine transplanting can be raised in the paper-sheet tray without nursery soils. The labour hours and cost required for the soil-free method using paper was reduced by about 49.3% and 26.6%, respectively, compared with the semi-adult seedling on nursery soils.

  • PDF

The Enhancement of Skin Sparing by Tray Materials for High Energy Photon Beam (고에너지 광자선치료에서 고정판 흡수물질을 이용한 피부보호효과의 향상)

  • Chu, Sung-Sil;Lee, Chang-Geol;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.449-454
    • /
    • 1993
  • The skin sparing effect associated with high energy x-ray or gamma ray beams may be reduce or lost under certain conditions of treatment. Current trends in using large fields. Shield carrying trays, compensating filters, and isocentric methods of treatment have posed problems of increased skin dose which sometimes become a limiting factor in giving adquate tumor doses. We used the shallow ion chamber to measure the phantom surface dose and the physical treatment variables for Co-60 gamma ray, 4MV and 10 MV x-ray beam. The dependence of percent surface dose on field sizes, atomic number of the shielding tray materials and its distance from the surface for 4, 10MV x-rays and Co-60 gamma ray is qualitatively similar. The use of 2 mm thick tin filter is recommended for situations where a low atomic number tray is introduced into the beam at distances less than 15 cm from the surface and with the large field sized for 4 MV x-ray beam. In case of Co-60 gamma ray, the lead glass tray is suitable for enhancement of skin sparing. Also, the filter distance should be as large as possible to achieve substantial skin sparing.

  • PDF

Effect of the Slow-releasing Fertilizer Applied Directly to Rice Seedling Tray Before Transplanting and Practical Test at Field (이앙직전 벼 육묘상자 살포용 완효성 비료의 처리 효과)

  • Chi, Jeong-Hyun;Choi, Byoung-Rourl;Jo, Gwang-Lae;Kim, Soon-Jae;Park, Kyeong-Yeol;Kwon, O-Youn
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.58 no.1
    • /
    • pp.8-14
    • /
    • 2013
  • The newly developed fertilizer is the slow-releasing fertilizer which can be used as a basal fertilizer without no additional fertilization at tillering stage. It has 30-4-6% of $N-P_2O_5-K_2O$ and was coated with mixture of LDPE (Low density polyethylene), EVA (Ethylene vinyl acetate), BDP (Bio degraded polymer), TALC and nonionic surfactant for the controlled release up to 50 days after application. Coating materials were designed to be decomposed naturally. This fertilizer can be applied directly to the seedling tray mechanically just before transplanting, resulting in significant labor saving effect. The developed slow-release fertilizer, which can replace both basal fertilization and top dressing at tillering stage by single application directly to seedling tray, showed the highest release at 14~21 days after transplanting. Considering the plant growth at different growth stages and yield, the optimal application rate of developed slow-release fertilizer was 300 g per rice nursery tray and the yield of rice at this application rate was 5.25 MT/ha. Rice quality in terms of head rice grain ratio, amylose content, whiteness, and taste value decreased as fertilization rate increased from 200 g to 500 g per nursery tray. Fertilization rate based on quantity of fertilizer ingredients (N, P, K) was reduced by 49.3% compared to the standard application rate and there was 49.2% reduction in labor input for fertilization.