• Title/Summary/Keyword: translucency

Search Result 128, Processing Time 0.023 seconds

Clinical Principles in Esthetic Restoration (심미보철물의 임상적 원리)

  • Lee, Jong-Yeop
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.8 no.1
    • /
    • pp.10-17
    • /
    • 1999
  • Replacements for natural dentition must fulfil many criteria. An important aspect, especially for the patient, is aesthetic consideration. The shape and colour can be important factors in the aesthetic success of an anterior restoration. In order to allow for proper shape; the outline form, the spatial position of individual teeth and the surface characteristics must be considered. For the colour; translucency, value, chroma and hue must be expressed exactly. The dentist and technicians should catch up these very specific characteristics of the patient and convert them accurately to the restorations with the simplest way.

  • PDF

Comparison of the optical properties of pre-colored dental monolithic zirconia ceramics sintered in a conventional furnace versus a microwave oven

  • Kim, Hee-Kyung;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.394-401
    • /
    • 2017
  • PURPOSE. The purpose of this study was to compare the optical properties of pre-colored dental monolithic zirconia ceramics of various thicknesses sintered in a microwave and those in a conventional furnace. MATERIALS AND METHODS. A2-shade of pre-colored monolithic zirconia ceramic specimens ($22.0mm{\times}22.0mm$) in 3 thickness groups of 0.5, 1.0, and 1.5 mm were divided into 2 subgroups according to the sintering methods (n=9): microwave and conventional sintering. A spectrophotometer was used to obtain CIELab color coordinates, and translucency parameters and CIEDE2000 color differences (${\Delta}E_{00}$) were measured. The relative amount of monoclinic phase ($X_m$) was estimated with x-ray diffraction. The surface topography was analyzed by atomic force microscope and scanning electron microscope. Statistical analyses were conducted with two-way ANOVA (${\alpha}=.05$). RESULTS. There were small interaction effects on CIE $L^*$, $a^*$, and TP between sintering method and thickness (P<.001): $L^*$ (partial eta squared ${{\eta}_p}^2=0.115$), $a^*$ (${{\eta}_p}^2=0.136$), and TP (${{\eta}_p}^2=0.206$), although higher $b^*$ values were noted for microwave sintering regardless of thickness. Color differences between two sintering methods ranged from 0.52 to 0.96 ${\Delta}E_{00}$ units. The $X_m$ values ranged from 7.03% to 9.89% for conventional sintering, and from 7.31% to 9.17% for microwave sintering. The microwave-sintered specimen demonstrated a smoother surface and a more uniform grain structure compared to the conventionally-sintered specimen. CONCLUSION. With reduced processing time, microwave-sintered pre-colored dental monolithic zirconia ceramics can exhibit similar color perception and translucency to those by conventional sintering.

Effect of immersion into solutions at various pH on the color stability of composite resins with different shades

  • Moon, Ji-Deok;Seon, Eun-Mi;Son, Sung-Ae;Jung, Kyoung-Hwa;Kwon, Yong-Hoon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.4
    • /
    • pp.270-275
    • /
    • 2015
  • Objectives: This study examined the color changes of a resin composite with different shades upon exposure to water with different pH. Materials and Methods: Nanohybrid resin composites (Filtek Z350XT, 3M ESPE) with four different shades (A2, A3, B1, and B2) were immersed in water with three different pH (pH 3, 6, and 9) for 14 day. The CIE $L^*a^*b^*$ color coordinates of the specimens were evaluated before and after immersion in the solutions. The color difference (${\Delta}E^*$) and the translucency parameter (TP) were calculated using the color coordinates. Results: ${\Delta}E^*$ ranged from 0.33 to 1.58, and the values were affected significantly by the pH. The specimens immersed in a pH 6 solution showed the highest ${\Delta}E^*$ values (0.87 - 1.58). The specimens with a B1 shade showed the lowest ${\Delta}E^*$ change compared to the other shades. TP ranged from 7.01 to 9.46 depending on the pH and resin shade. The TP difference between before and after immersion in the pH solutions was less than 1.0. Conclusions: The resulting change of color of the tested specimens did not appear to be clinically problematic because the color difference was < 1.6 in the acidic, neutral, and alkaline solutions regardless of the resin shade, i.e., the color change was imperceptible.

Effects of different surface finishing procedures on the change in surface roughness and color of a polymer infiltrated ceramic network material

  • Ozarslan, Mehmet Mustafa;Buyukaplan, Ulviye Sbnem;Barutcigil, Cagtay;Arslan, Merve;Tuker, Nurullah;Barutcigil, Kubilay
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.16-20
    • /
    • 2016
  • PURPOSE. Polymer infiltrated ceramic network (PICN) materials, also called hybrid ceramics, are new materials in dental market. The manufacturer of the PICN material VITA Enamic suggests 3 different finishing procedures for this new material. In the present study, surface roughness and color differences caused from different finishing procedures of VITA Enamic were investigated. MATERIALS AND METHODS. 120 specimens were prepared in dimensions $2{\times}10{\times}12mm$ from VITA Enamic hybrid ceramic blocks with 'high translucency' and 'translucency 2M2' shades. The specimens were divided into 8 groups. For each group, different finishing procedures suggested by the manufacturer were performed. Surface roughness values were determined by a tactile portable profilometer. Color changes were evaluated using a clinical spectrophotometer. The data were analyzed using one-way ANOVA and Tukey's post-hoc comparison. The significance level was set at ${\alpha}=0.05$. RESULTS. The roughest surfaces were observed in Glaze Groups. Their surface roughness values were similar to that of the control group. Clinical Kit and Technical Kit groups did not show a statistically significant difference regarding surface roughness (P>.05). The largest color difference regarding ${\Delta}E_{00}$ was observed in Clinical Kit finishing groups. There were also statistically significant color changes between the groups (P<.05). However, all the groups showed clinically acceptable color change (${\Delta}E_{00}$<2.25) except Clinical Kit Groups (${\Delta}E_{00}$>2.25). CONCLUSION. Within the limitations of the present study, it may be suggested that finishing the VITA Enamic restorations by Technical Kit instead of Glaze and Clinical Kit gives better clinical performance in regard to surface roughness and shade matching.

Physicochemical characterization of two bulk fill composites at different depths

  • Guillermo Grazioli ;Carlos Enrique Cuevas-Suarez ;Leina Nakanishi ;Alejandro Francia;Rafael Ratto de Moraes
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.3
    • /
    • pp.39.1-39.12
    • /
    • 2021
  • Objectives: This study analyzed the physical-chemical behavior of 2 bulk fill resin composites (BFCs; Filtek Bulk Fill [FBF], and Tetric-N-Ceram Bulk Fill [TBF]) used in 2- and 4-mm increments and compared them with a conventional resin composite (Filtek Z250). Materials and Methods: Flexural strength and elastic modulus were evaluated by using a 3-point bending test. Knoop hardness was measured at depth areas 0-1, 1-2, 2-3, and 3-4 mm. The translucency parameter was measured using an optical spectrophotometer. Real-time polymerization kinetics was analyzed using Fourier transform infrared spectroscopy. Results: Flexural strength was similar among the materials, while TBF showed lower elastic modulus (Z250: 6.6 ± 1.3, FBF: 6.4 ± 0.9, TBF: 4.3 ± 1.3). The hardness of Z250 was similar only between 0-1 mm and 1-2 mm. Both BFCs had similar hardness until 2-3 mm, and showed significant decreases at 3-4 mm (FBF: 33.45 ± 1.95 at 0-1 mm to 23.19 ± 4.32 at 3-4 mm, TBF: 23.17 ± 2.51 at 0-1 mm to 15.11 ± 1.94 at 3-4 mm). The BFCs showed higher translucency than Z250. The polymerization kinetics of all the materials were similar at 2-mm increments. At 4-mm, only TBF had a similar degree of conversion compared with 2 mm. Conclusions: The BFCs tested had similar performance compared to the conventional composite when used in up to 2-mm increments. When the increment was thicker, the BFCs were properly polymerized only up to 3 mm.

Development of dental zirconia (치과용 지르코니아의 발전)

  • Kim Sung-Hun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.32 no.1
    • /
    • pp.4-7
    • /
    • 2023
  • Since the end of the 1990s, zirconia, which has been applied to dental prostheses, has been used in the form of coping or framework. The prostheses made in this way have been successfully used in the anterior teeth because they have no metal components as a structure. But in the posterior teeth, its use was limited due to the fracture or chipping of the veneering porcelain during the function. Later, as a solution to this shortcoming, a monolithic zirconia restoration was proposed in which a strong coping material was used in the form of a complete prosthesis. But, this resulted in some unesthetic results due to the characteristics of zirconia, which has excellent resistance to strong forces but is very white and opaque. However, now, due to technological advances in increasing the translucency of zirconia, it is possible to produce strong and esthetic zirconia restorations not only in the posterior region but also in the anterior region. In this article, the structural characteristics of various types of zirconia materials that have been developed so far, were discussed, and where the zirconia products actually in use belong to was explained.

Comparison of the Ability to Mask the Color of Endodontic Filling Materials Using Several Types of Base Materials

  • Hyun-Ji Shin;Hyuntae Kim;Ji-Soo Song;Teo Jeon Shin;Young-Jae Kim;Jung-Wook Kim;Ki-Taeg Jang;Hong-Keun Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.51 no.3
    • /
    • pp.220-228
    • /
    • 2024
  • In clinical pediatric dentistry, a base material with optical properties, including transparency, that can mask the color of the material used for root canal-filling is preferred. This study aimed to examine the optical properties of various base materials by thickness. The disk-shaped specimens were photopolymerized and fabricated using Ionosit (IN), TheraCal LC (TL), TheraCal PT (PT), and A2 shade of FiltekTM Supreme Flowable Restorative (FZ), Fuji II LC (FL), and KetacTM Fil (KF) with 1 and 2 mm thickness. The color parameters of these specimens were measured using a spectrophotometer on a black and white background and were measured using the same method on a mold containing Vitapex® and gutta-percha. The translucency parameter (TP) and color difference were calculated for each group. The Kruskal-Wallis and Bonferroni tests were used in the statistical analyses. The TP decreased when the thickness was 2 mm compared with 1 mm. The TP values of TL and PT were the lowest at all thicknesses. The TP values of 2 mm thickness in all molds filled with Vitapex® and gutta-percha were the lowest for TL, PT, KF, and IN. In TL and PT, the color difference before and after the application of the canal-filling material was the smallest, regardless of material thickness. Within the limits of this in vitro study, TL, PT, KF, and IN demonstrated better masking of the color of canal-filling material.

Influencing factors on the final color of laminate veneer restorations with various IPS Empress Esthetic$^{(R)}$ ingots (다양한 IPS Empress Esthetic$^{(R)}$ ingot으로 제작한 laminate veneer의 최종 색조에 대한 영향)

  • Yang, Mi-Seon;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.308-315
    • /
    • 2011
  • Purpose: The purpose of this study was to colorimetrically evaluate the masking effect of different opacity of ingots on the final shade of IPS Empress Esthetic$^{(R)}$ laminate veneer restorations using the CIE $L^*a^*b^*$ system. Materials and methods: Six porcelain disks of IPS Empress Esthetic$^{(R)}$ system (translucency: E 01, E 03, E 0C-1, E TC-1, E TC-2, E TC-3) were fabricated with 7 mm in diameter and 0.6 mm in thickness. Six extracted human incisors (shade: A1, A3, A4, B2, B3, C3) were used as the abutment specimens. The incisors were prepared using a diamond wheel and made with a flat labial surface on the middle 1/3. For each combination of different shades of abutments and copings, the change in color was measured with a colorimeter. CIE $L^*a^*b^*$ coordinates were recorded for each specimen. Color differences (${\Delta}E$) were calculated. Descriptive statistical analysis was done. Results: ${\Delta}E$ values were significantly affected by coping translucency and abutment shade (P<.05). The color differences (${\Delta}E$) of laminate veneers among abutments with A3, B3, C3, and A4 shade were mostly below 2.7 which was within the clinically acceptable range, while color differences between A4 and B2, A3 and B2, and A1 and A4 showed more than 2.7. Conclusion: The final color of IPS Empress Esthetic$^{(R)}$ laminate veneers were significantly influenced by translucency of the coping and shade of abutment teeth. The large value difference of abutment teeth limited the masking ability by laminate veneers.

Representation of Translucent Objects using Multiple Projection Images for Real-time Rendering (시점을 달리한 여러 장의 투영 영상을 이용한 반투명 재질의 실시간 렌더링)

  • Lee, Jae-Young;Kim, Kang-Yeon;Yoo, Jae-Doug;Lee, Kwan-H.
    • 한국HCI학회:학술대회논문집
    • /
    • 2006.02a
    • /
    • pp.878-883
    • /
    • 2006
  • 반투명 물체(Translucent Object)는 불투명한 물체와는 달리 물체 내부에서 산란이 일어난다. 반투명 물체의 한 표면(Surface)을 렌더링하기 위해서는 그 표면의 정규 벡터뿐만 아니라 그 표면의 주변 기하 정보가 필요하다. 그러나 그래픽 하드웨어 구조는 반투명 물체의 실시간 렌더링의 구현에 많은 제약을 준다. 3D 기하 정보 대신에 라디언스 맵(Radiance map)과 깊이 맵(Depth map)과 같은 투영 영상(Projected Image)을 기반으로 하는 영상 공간 접근 방법(Image Space Approach)을 사용함으로써 GPU 상에서 반투명 재질을 실시간으로 표현할 수 있다. 본 논문에서는 영상 공간 접근 방법(Image Space Approach)의 연장선에서 시점을 달리한 여러 장의 투영 영상을 이용함으로써 기존의 한 장의 투영 영상만을 이용한 방법이 가지고 있는 가시성 한계점을 해결한다. 또한 복수 투영 영상의 이용에 따른 계산량 증가에 의해서 손실된 프레임 속도(Frame Rate)에 대해 분석한다.

  • PDF

ShadeScan system의 반복 재현성에 관한 연구

  • Jo, Cheol-Hui;Lee, Seok-Jin;Seo, Jong-Cheol;Lee, Jong-Yeop
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.13 no.2
    • /
    • pp.29-35
    • /
    • 2004
  • 최근 심미적인 보철 치료에 대한 사람들의 관심이 높아짐에 따라 자연치와 더욱 조화롭게 보철 치료를 하는 것이 요구되고 있다. 이는 구조적인 심미성과 함께 자연스러운 색조 재현을 통하여 이루어지는데, 자연치의 색조는 매우 다양하고 부위별로 달라질 수 있기 때문에 단순히 shade guide상의 비교만으로는 정확한 색조를 얻기가 어렵다. 이러한 색조 선택의 부정확성 때문에 객관적으로 색조를 분석하는 많은 기계적 장치들이 고안되었고, 최근에 ShadeScan system(CYNOVAD, Canada), Vita Easyshade system(Vident, Canada) 등 디지털로 색조를 평가하는 시스템이 각광을 받고 있다. ShadeScan system은 한 번의 클릭으로 치아 이미지를 채득할 수 있고, 바로 컴퓨터를 통해서 이를 분석하여 원하는 shade map, translucency map 등을 얻을 수 있다. 또한 세 방향에서 조사되는 빛은 자체 calibration을 거쳤기 때문에 주변 광원이나 환경의 영향 없이 객관적으로 치아의 이미지를 채득할 수 있다고 한다. 사실 그 동안 이미지 채득이 객관적이라고 주장하는 많은 system이 있었지만 임상의들은 그 신뢰성에대해 의구심을 보였던 것이 사실이다. 이에 본고에서는 ShadeScan system이 반복 촬영 시 같은 색조재현을 할 수 있는지 실험하여 그 객관성에 대해 살펴보았다.

  • PDF