• Title/Summary/Keyword: transient improvement

Search Result 323, Processing Time 0.032 seconds

Transient-Liquid-Phase Bonding of Fe-Base MA956 ODS Alloy (Fe기 MA956 산화물분산강화합금의 천이액상확산접합에 관한 연구)

  • 강지훈
    • Journal of Powder Materials
    • /
    • v.2 no.1
    • /
    • pp.53-62
    • /
    • 1995
  • TLP(Transient-Liquid-Phase) bonding of Fe-base MA956 ODS alloy was performed. As insert metal a commercially available Ni-base alloy(MBF50) and an MA956 alloy with additive elements of 7wt% Si and 1wt% B were used. To confirm the idea that a concurrent use of MA956 powder with Insert metals can enhance the homogenization of constituent elements and thereby reduce the thickness of joint interface, MA956 powder was also inserted In a form of sheet. SEM observation and EDS analysis revealed that Cr-rich phase was formed in the bonded interface in initial stage of isothermal solidification during the bonding process, irrespective of kind of insert metals. Measurement of hardeness in the region of bonded interface and EDS analysis showed that a complete homogenization of composition could not be obtained especially in case of MBF50. Joints using either BSi insert metals only or BSi insert together with MA956 powder interlayer showed, however, a remarkable improvement in a compositional homogenization, even though a rapid grain growth in the bonded interface could not be hindered.

  • PDF

The Efficiency Improvement of Flocculation Facilities in Water Treatment Plants (정수장 응집설비의 효율증대 방안연구)

  • Jeon, Bok-Su;Lee, Eun-Woong;Lim, Su-Saemg;Choi, Jae-Young;Kim, Hong-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.952-954
    • /
    • 2000
  • In the cleaning-water treatment process, the flocculation machine is operated by the V.S motor when the coagulation-facility of the coagulation-process is operated. But after the flocculation machine is stopped by an instantaneous power failure, the transient takes place when the coagulation facility is re-started. To improve the transient state, we developed the reinforcement-circuit which had the function of soft-start and adapted to the field. As a result of this study, we reduced the damage of facilities and had the safety in maintaining the quality of water and improved the efficiency in the maintenance and the management.

  • PDF

A Study on Improving the Efficiency of Ground Heat Exchanger (지중열교환기 성능 향상에 관한 연구)

  • Kim, Ook-Joong;Lee, Kong-Hoon;Kim, Min-Su
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3142-3147
    • /
    • 2008
  • A simple transient simulation of ground source heat pump system was carried out to investigate the effects of ground thermal conductivity on its performance. The TRNSYS code with a simple water to water heat pump model was used to compare the COP variation of the system. A new ground heat exchanger called by semi-closed loop was proposed and constructed in the real site. The effective thermal conductivity was measured using the test equipment developed by according to the line source model. The simulation results showed that highly efficient thermal conductivity of the grout material could increase the performance of the heat pump system very well. And the new ground heat exchanger showed the increased effective thermal conductivity as the penetration water flow rate(PWFR) was increased. Therefore, the performance improvement of the heat pump system using the proposed ground heat exchanger can be expected.

  • PDF

An Optimization Method of Series Condenser for Improvement of Transient Stability (과도안정도 향상을 위한 직렬콘덴서의 최적화 방안)

  • You, Seok-Ku;Moon, Byoung-Seo;Kim, Kyu-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.890-892
    • /
    • 1996
  • This paper presents a method for optimal placement of series condenser in order to improve the power system transient stability using genetic algorithms(GAs). In applying GAs, this approach utilizes two kinds of strings, one is coded by a binary finite-length for the selection of lines to install series condenser, the other is coded by a real value for the determination of injected condenser capacitance. For the formulation. this paper considers multi-objective function which is the critical energy as decelerating energy in power systems and the total injected condenser capacitance. The proposed method is applied to 9-bus, 18-line, 3-machine model system to show its effectiveness in determining the locations to install series condenser and the series condenser capacitance to be injected, simultaneously.

  • PDF

Experimental Study of The Floating-Phenomenon on Neutral Ungrounded UPS System (중성점 비접지 UPS시스템의 부동현상에대한 실험적 연구)

  • Shim, Hae-Sup
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.67-72
    • /
    • 2011
  • In this study we investigate the background of UPS output transformer(${\Delta}-Y$) operation on neutral ungrounded system, and perform field experiment of neutral floating-phenomenon for the inter-locked securing of electric facilities and improvement of neutral floating-phenomenon. Experiment results show that a floating-phenomenon occurs when four-pole input-breaker trip and the neutral to earth voltage occurring concurrently is identified as phantom voltage. And the measures for the transient overvoltage that can occur in floating-state also are investigated. As a result, the risk elements of neutral ungrounded method as well as neutral floating-phenomenon are removed by installation of separate solidly-grounded transformer and switching four-pole input-breaker to three-pole input breaker.

Studies on the Detection of Visual-TEP with Average Method & the Improvement of TEP with DC-Drift Elinination (Average 기법에 의한 Visual-TEP의 검출과 DC-Drift 제거에 의한 TEP 신호개선에 관한 연구)

  • 배병훈;최정미
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.2
    • /
    • pp.135-142
    • /
    • 1994
  • This paper presents average method to detect Visual-Transient Evoked Potential from the human scalp electric potential measured by the ElectroEncephaloGram. To confirm the validity of average method, the average-process is performed with both stimulated and no-stimulated potentials respectively, and both results are compared. The specific waveform, which is visual-transient evoked potential, is produced only in the case of stimulated potential. It was found that a dc-drift, due to instrumentation errors and other noises, can produce significant changes in the evoked-potential waveform. This can be removed with a high-pass filter (cut-off frequency=0.5Hz).

  • PDF

Safety evaluation of agricultural reservoir embankment according to backside extension (후면 덧쌓기에 따른 농업용 저수지 제체의 안정성 평가)

  • Lee, Dal-Won;Noh, Jae-Jin
    • Korean Journal of Agricultural Science
    • /
    • v.39 no.1
    • /
    • pp.97-110
    • /
    • 2012
  • This study was carried out for safety evaluation, the practical application and improvement of design method of the agricultural reservoir embankment according to backside extension. Seepage analysis, slope stability analysis and finite element analysis were performed for steady state and transient conditions. Also, the pore water pressure, seepage quantity, safety factor and stress-strain behavior according to high water level and rapid drawdown were compared and analyzed. The pore water pressure at contact region between backside extension and old embankment was kept high after rapid drawdown. Therefore, backside extension is recommended that design method is required to be improved and reinforced more than the others raising embankment. The hydraulic gradients before and after backside extension showed high value at the base of the core, but they showed stable state at the upstream slope and downstream slope. The seepage quantity per 1 day and the leakage per 100 m for the steady state and transient conditions appeared to be safe against the piping. The safety factor of slope stability showed high at the steady state, and transient conditions did not show differences depending on the rapid drawdown. The safety factor was appeared high at the upstream slope before backside extension and downstream slope after extension. The excess pore water pressure for steady state and transient conditions showed negative(-) at the upstream slope, it was small at the downstream slope. The mean effective stress (p') showed high at the base of the core and to be wild distribution after the extension. The displacement after extension showed 0.02-0.06 m in the upstream slope, the maximum shear strain after extension was smaller than that before extension.

Development of Transgenic Fish for the Production of Human EGF Protein (내재적 유전자에 의한 어류난자에서의 hEGE 단백질 생산을 위한 기술개발)

  • 황창남;송기철;이재현;윤종만;김기동;이상호;박홍양
    • Korean Journal of Animal Reproduction
    • /
    • v.25 no.3
    • /
    • pp.277-286
    • /
    • 2001
  • Improvement and possible commercialization of a home-made electroporation apparatus(home-made) were further tried to establish a simple and effective introduction of foreign gene into sperm followed by in vitro fertilization. Expressions of introduced pJJ9 and pNT plasmids were shown in all fertilized eggs with electroporated spermatozoa. In particular, with this gene transfer system all the fry showed a consistently transient expression in the syncytium of the yolk sac. This fact is important since some required, minute quantity of human proteins can be produced from the established transient expression on the yolk sac of all fry derived from in vitro fertilization with electroporated spermatozoa. To explore tissue-specific expression in fish, which we will use a similar system later, we targeted the nerve tissue to see whether tissue-specific promoter is working in fish properly. pNT plasmid containing a nerve cell-specific tubulin promoter gene demonstrated consistently exact targeted expressions among the developing nerve cells in later stages of embryos and hatched fry. Finally, liver-specific genes are now being cloned by using already selected primers for useful human protein gene fusion.

  • PDF

Ionization Behaviors in Various Soils Subjected to Impulse Currents (임펄스전류에 의한 토양의 종류별 이온화 특성)

  • Lee, Bok-Hee;Kim, Hoe-Gu;Park, Geon-Hun;Baek, Young-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.87-94
    • /
    • 2008
  • This parer presents the soil ionization phenomena and parameters associated to characterize the transient performances of grounding system under lightning impulse Currents. Ionization properties in occurring some soil media were experimentally investigated. The cylindrical test cell was employed in order to facilitate the analysis of soil breakdown field intensity and ionized radius. The soil breakdown field intensity, dependence of impedance on the amplitude of impulse current, V-I curves and transient impedances were discussed based on the voltage and current oscillograms. It was found that the ionization process and dynamic behaviors were strongly dependent on the types of soil and two current peaks were not observed in highly water-saturated soils. The results presented in this paper will provide useful information on the improvement of transient performance of a grounding system subjected to lightning impulse Current considering the soil ionization.

Transient Stability Analysis of Vessel Power System Using Alternative Marine Power (육상전원공급장치(AMP) 이용한 선내 전원 공급 시 계통 안정도 분석)

  • Seung-pyo Kang;Jang-mok Kim;Hyun-jun Cho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.2
    • /
    • pp.215-222
    • /
    • 2023
  • Alternative marine power (AMP) is continuously used in ports and on docks because of regulations on global ship emission reduction. In Korea, the use of AMP is also mandatory under the Special Act on Port Air Quality Improvement, and efforts are under way in connection with various eco-friendly ships, such as electric-propulsion ships. In this study, AC load flow analysis was performed by modeling the situation in which onboard power is supplied through AMP. This analysis made it possible to study the electrical parameters and losses when power was supplied to the ship. In addition, through a transient stability analysis, the high-speed generation transfer limit value for uninterruptible conversion through onboard generators in the event of a system accident was derived. The results obtained when it was applied are presented