• Title/Summary/Keyword: transient gain control

Search Result 115, Processing Time 0.026 seconds

A Distributed Control Method based on Voltage Sensitivity Matrix in DC Microgrids for Improvement of Power Sharing Accuracy and Voltage Regulation Performance (직류 마이크로그리드의 전력 공유 정확도 및 전압 제어 성능 향상을 위한 전압 민감도 행렬 기반의 분산 제어 방법)

  • Lee, Gi-Young;Ko, Byoung-Sun;Lee, Jae-Suk;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.5
    • /
    • pp.345-351
    • /
    • 2018
  • A distributed control method is proposed to improve the power sharing performance of bidirectional distributed generators and the voltage regulation performance of a DC bus in a DC microgrid. Voltage sensitivity analysis based on power flow analysis is conducted to analyze the structural characteristics of a DC microgrid. A distributed control method using a voltage sensitivity matrix is proposed on the basis of this analysis. The proposed method uses information received through the communication system and performs the droop gain variation method and voltage shift method without additional PI controllers. This approach achieves improved power sharing and voltage regulation performance without output transient states. The proposed method is implemented through a laboratory-scaled experimental system consisting of two bidirectional distributed generators, namely, a load and a non-dispatchable distributed generator in a four-bus ring-type model. The experimental results show improved power sharing accuracy and voltage regulation performance.

Design and Implementation of The Feedback Fuzzy Controller (궤환 퍼지제어기 설계와 구현)

  • 이상윤;신위재
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.10 no.5
    • /
    • pp.401-408
    • /
    • 2000
  • In this paper, we proposed a fuzzy controller that founded by the general feedback control with the new adjustment method when it's tuning. The general feedback controller is operated that supply to the plant making the control input multiplying the appropriate gain of controller on the error between the output of the plant and the reference, But proposed feedback fuzzy controller consist of three loops. The inner loop consists of plant and an ordinary feedback controller. The fuzzy inference of controller performed by the outer loops, which is composed of a fuzzy modeling and inference. We can observe that the output of control system converges toward the reference. Also, the behaviour of feedback fuzzy system is converged from the transient. That is, we verified that designed fuzzy controllers was adapted effectively through the experiments in the hydraulic motor system using floating point DSP processor.

  • PDF

Modelling and Simulation of Rotary Compressor in Refrigerator (냉동기용 로터리 압축기의 모델링 및 시뮬레이션)

  • Park, Min-Woo;Chung, Youn-Goo;Park, Kyoung-Woo;Pak, Hi-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.1
    • /
    • pp.39-49
    • /
    • 2000
  • This paper presents the modeling approach that can predict transient behavior of rotary compressor. Mass and energy conservation laws are applied to the control volume, real gas state equation is used to obtain thermodynamic properties of refrigerant. The valve equation is solved to analyze discharge process also. Dynamic analysis of vane and roller is carried out to gain friction work. From the above modeling, the performance of rotary compressor with radial clearance and friction loss is investigated numerically. The performance of each refrigerant is estimated, respectively by applying R12, R134a, and R290/ R600a mixture.

Nonlinear Feedback Linearization-H\ulcorner/Sliding Mode Controller Design for Improving Transient Stability in a Power System

  • Lee, Sang-Seung;Park, Jong-Keun
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.2
    • /
    • pp.193-201
    • /
    • 1998
  • In this paper, the standard Dole, Glover, Khargoneker, and Francis (abbr. : DGKF 1989) H\ulcorner controller (H\ulcornerC) is extended to the nonlinear feedback linearization-H\ulcorner/sliding mode controller (NFL-H\ulcorner/SMC), to tackle the problem of the unmeasurable state variables as in the conventional SMC, to obtain smooth control as the linearized controller in a linear system, and to improve the time-domain performance under a worst scenario. The proposed controller is obtained by combining the H\ulcorner estimator with the nonlinear feedback linearization-sliding mode controller (NFL-SMC) and it does not need to measure all the state variables as in the traditional SMC. The proposed controller is applied as a nonlinear power system stabilizer (PSS) for the improvement of the power system damping characteristics of an single machine infinite bus system (SMIBS) connected through a double circuit line. The effectiveness of the proposed controller is verified by nonlinear time-domain simulation in case of a 3-cycle line-to-ground fault and in case of the parameter variations for the AVR gain K\ulcorner and for the inertia moment M.

  • PDF

A Study on the Effects of Motion Errors for Acceleration/Deceleration Types (가감속 형태에 叫른 운동오차의 영향에 대한 연구)

  • 신동수;곽경남;정성종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.671-677
    • /
    • 1996
  • This paper proposes a study on the effects of motion errors for acceleration/ deceleration types. The proposed motion errors are consisted of two errors : one due to transient response of servomechanism and the other due to gain mismatching of positioning servo motor. They are derived from using laplace transformation for the block diagram of general purpose feed drive system. In order to minimize them, the paper proposes second order polynomial regression model by using orthogonal array method which describes one of experimental methodolgies. The validity and reliability of the study was veri lied on a vertical machining center equipped with FANUC 0MC through a series of experiments and analyses.

  • PDF

Experimental Study of the Effect of the Reservoir on CPL Operation (CPL의 운전에 미치는 레저버의 영향에 대한 실험적 연구)

  • Hwang, Hyung-Jin;Joung, Wuk-Chul;Lee, Jin-Ho
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2033-2038
    • /
    • 2008
  • The CPLs(capillary pumped loops) are two phase heat transfer devices which enable active control of operating temperature of heat absorbing elements(or evaporators). Although the CPLs gain increasing interests as promising heat transfer devices for future missions such as spacecraft and commercial applications, their intrinsic complexity in operating principles makes the widespread use of these devices difficult. The key element and main cause of this complexity in operating principles is the two phase hydrodynamic accumulator or reservoir which controls the saturation state of the remaining loop and, particularly for the CPLs, it is separated from the evaporator. Thus, in this study, the operating characteristics of the CPL is investigated experimentally and theoretically. Mainly focusing on the role of reservoir the thermodynamic operating principle is examined first and the experimentally obtained steady state and transient state operating characteristics are discussed in detail.

  • PDF

The Burst Effect Analysis of 2.5 Gb/s TDM-PON Systems Using a SOA Link Extender (반도체광증폭기로 전송거리 확장된 2.5 Gb/s TDM-PON에서 버스트 효과에 의한 신호왜곡 분석)

  • Choi, Bo-Hun;Lee, Sang Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.1
    • /
    • pp.6-11
    • /
    • 2012
  • A bidirectional TDM-PON link to support 2.5 Gb/s upstream signals of 256 ONUs was considered for an extended transmission distance of 50 km. The power budget of the link was 58 dB for the upstream signal and a SOA was applied as a link extender which had a 25 dB gain. Receiver sensitivity of the upstream signal was -25 dBm for -30 dBm input power to the SOA. When the input power was -10 dBm, pulse overshooting caused by gain transient of the SOA was maximum at 45% and the signal performance degradation gave a power penalty of 1.55 dB for $10^{-12}$ BER. However the penalties diminished rapidly and became negligible as the input power went below -15 dBm. So this input power dynamic range of up to -15 dBm means that it is not positively necessary to use gain control methods for the next generation TDM-PON systems.

Modelling a Stand-Alone Inverter and Comparing the Power Quality of the National Grid with Off-Grid System

  • Algaddafi, Ali;Brown, Neil;Rupert, Gammon;Al-Shahrani, Jubran
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.1
    • /
    • pp.35-42
    • /
    • 2016
  • Developments in power electronics have enabled the widespread application of Pulse Width Modulation (PWM) inverters, notably for connecting renewable systems to the grid. This study demonstrates that a high-quality power can be achieved using a stand-alone inverter, whereby the comparison between the power quality of the stand-alone inverter with battery storage (off-grid) and the power quality of the utility network is presented. Multi-loop control techniques for a single phase stand-alone inverter are used. A capacitor current control is used to give active damping and enhance the transient and steady state inverter performance. A capacitor current control is cheaper than the inductor current control, where a small current sensing resistor is used. The output voltage control is used to improve the system performance and also control the output voltage. The inner control loop uses a proportional gain current controller and the outer loop is implemented using internal model control proportional-integral-derivative to ensure stability. The optimal controls are achieved by using the Sisotool tool in MATLAB/Simulink. The outcome of the control scheme of the numerical model of the stand-alone inverter has a smooth and good dynamic performance, but also a strong robustness to load variations. The numerical model of the stand-alone inverter and its power quality are presented, and the power quality is shown to meet the IEEE 519-2014. Furthermore, the power quality of the off-grid system is measured experimentally and compared with the grid power, showing power quality of off-grid system to be better than that of the utility network.

Vector Control of Induction Motor Using Hybrid Controller (하이브리드 제어기를 사용한 유도전동기 벡터제어)

  • 류경윤;이홍희
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.352-357
    • /
    • 2000
  • The vector control scheme is usually applied to the high performance induction motor drives. The PI controller is adopted traditionally to control the motor speed and currents in the vector control scheme. In this case, the dynamic performance of the induction motor is dependent on the PI gains and the gain optimization is necessary in order to get a good dynamic performance. But, it is very hard to optimize the PI gains uniquely within the speed control range because the equivalent model of the motor control system should be known exactly. In this paper, we propose the hybrid control scheme to remove the defects of PI controller. The hybrid control scheme includes the simplified fuzzy controller which operates in the transient state and the PI controller which operates in the steady state. The proposed scheme is applied to the vector control for induction motor, and the digital simulation and the experimental results are given to verify the proposed scheme.

  • PDF

An Anti-Windup Compensation for Systems with Saturation Actuators (포화 요소가 있는 계를 위한 와인드업 방지 보상 방법)

  • 장원욱;박영진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.7
    • /
    • pp.1332-1340
    • /
    • 1992
  • A novel approach based on a nonlinear compensator is prposed to prevent 'windup', which is caused by the saturation of the acutator and the integral action of the controller. The anti-windup compensator is located between the conventional linear controller, designed neglecting the saturation, and the actuator. It was proven based on the describing function method that, if the closed loop control systems are stable assuming no saturation, then there may exist a range of compensator gain which prevents any limit-cycle. The computer simulation results show that the compensator proposed in the manuscript can eliminate the limit cycle and improve the transient response.