병렬운전 변압기 전압제어 및 저압축 모선보호방식연구 (A Study of Voltage Control for Lower Side Parallel Transformer)

  • 윤기섭;백승도;최종혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.233-236
    • /
    • 2001
  • Parallel operation scheme to several transformers is adopted because of the load increase, economic problem, or load shedding. For the transformer's parallel operation, loads proportional to each transformer's capacity must be allotted, and circulation currents must be limited as much as without causing any problem in a real operation. But, both transformers in parallel operation can be tripped when either faults at lower voltage side of a transformer or faults in a bus occurs. Therefore, parallel operation scheme to distribution transformers in Korea is not adopted in a normal state but only when loaded or load-shedded. These are due to the insufficiency of the construction in communication network and AVR scheme. Besides that, those are because bus bar protection scheme to lower voltage side of a transformer is not applied. In spite of enormous initial investment costs, advanced countries take so much account of power system reliability and stable supply that they adopt the parallel operation scheme in a normal state. One of the problems in parallel operation is the overheat of transformers due to the excessive circulation currents. This paper presents the scheme that controls voltages between both transformers using circulation currents that occurs in parallel operation.

  • PDF

Suitability of Palm Based Oil as Dielectric Insulating Fluid in Transformers

  • Azis, Norhafiz;Jasni, Jasronita;Kadir, Mohd Zainal Abidin Ab;Mohtar, Mohd Nazim
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.662-669
    • /
    • 2014
  • Mineral oil has been widely used as dielectric insulating fluid in transformers due to its excellent performance in-service. However, there are few issues with mineral oil such as it has poor biodegradability and could contaminate the environment if a spillage occurs. With the increasing tight regulation on safety and environment, alternative fluids for mineral oil are currently being investigated and among the suitable candidate is the vegetable oil. There are different types of vegetable oils and one of them is the palm based oil. At the moment, extensive research works are carried out to examine its feasibility to be applied in transformers. This paper will review the previous research works that were carried out to examine the suitability of palm based oil as dielectric insulating fluid in transformers. The physical and chemical properties of palm based oil are studied based on viscosity, acidity, oxidation stability and flash point. Next, the electrical characteristics of palm based oil are examined based on AC breakdown voltage, relative permittivity, dissipation factor and partial discharge.

수직온도분포 분석을 이용한 몰드변압기 권선의 건전성 평가 연구 (A Study on the Integrity Evaluation of the Windings in Cast Resin Transformers Using Vertical Thermal Distribution Analysis)

  • 임용배
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.315-319
    • /
    • 2004
  • This paper presents the integrity evaluation method of the windings in cast resin transformers using vertical thermal distribution analysis. The method is to compare the temperature distribution in a sound condition specimen with that in the failure condition specimen layer-shorted by accelerated testing. The temperature distribution was acquisited by a infrared thermography system, and the Arrhenius equation was adopted to the accelerated testing. The proposed method may be available to detect the failures in cast resin transformers.

  • PDF

직렬주입변압기가 없는 새로운 UPFC의 동특성 분석 (Operation Analysis of Novel UPFC without Series Injection Transformers)

  • 백승택;한병문
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권12호
    • /
    • pp.641-648
    • /
    • 2003
  • This paper proposes a novel UPFE based on H-bridge modules, isolated through single-phase multi-winding transformers. The dynamic performance of proposed system was analyzed by simulation with EMTDC, assuming that the UPFC is connected with the 138-kV transmission line of one-machine-infinite-bus power system. The proposed system can be directly connected to the transmission line without series injection transformers. It has flexibility in expanding the operation voltage by increasing the number of H-bridge modules.

선형변이 차동변압기를 이용한 왕복운동 계측기법 (An Alternating Motion Technique Using Linear Variable Differential Transformers)

  • 최주호;김윤겸
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.1073-1077
    • /
    • 1996
  • This paper presents a recoil and counter recoil(R&CR) motion measurement method using linear variable differential transformers(LVDT). The output of a LVDT is obtained from the differential voltage of the 2nd transformers. As a sensor core is attached at the motion body, the output is directly proportional to the core motion. Displacement, velocity and acceleration are measure from the core length. With a comparison between the measurement result and the known value which is obtained by the precision steel tape, the accuracy and the usefulness of the proposed scheme is validated.

  • PDF

수용가 전력 소비 패턴을 고려한 배전용 변압기 과부하 판정기준 (Overload Criteria of Distribution Transformers Considering the Electric Consumption Patterns of Customers)

  • 윤상윤;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권9호
    • /
    • pp.513-520
    • /
    • 2004
  • In the paper, we summarize the result of the experimental research for the overload criteria of domestic distribution transformers considering the electric consumption patterns of customers. For the basic characteristic data of distribution transformer overload, the actual experiments are accomplished. The field data of loads are surveyed from sample transformers for analyzing the consumption pattern of customer load. The load data acquisition devices are equipped, and the algorithm of load pattern classification is applied. In addition to this efforts, various load pattern data. in past are gathered. Then the representative load pattern of each customer type in domestic is extracted. The final results of overload criterions are presented as tabular form through the results of experiments and survey are combined. The field test of the experiment results is peformed using the special manufactured transformers, which can measure both the load and top-oil temperature of transformer. Through this, we verify that the results of field test are similar to the laboratory one and the Proposed overload criteria can be effectively applied to the real system.

고조파를 포함하는 부하의 변압기 용량 산정에 관한 연구 (A Study on the Transformer Capability containing Harmonic Load Currents)

  • 김경철;박상영;이일무;백승현
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.287-292
    • /
    • 2004
  • The increasing use of nonlinear loads has resulted in an increase in the harmonic content of the load current for power transformers. Transformers subject to harmonic currents have higher losses and need to be derated. This paper presents a simple method for determining the capability of transformers to supply harmonic load currents and shows that the application of capacitor banks with a series connected reactor and harmonic filters will geatly increase the capability of transformers. The EDSA program was used as a simulation tool for the carse study.

  • PDF

DC 변전소 몰드변압기 온라인 상태 감시 시스템 구현 (Implementation of a Condition Monitoring System for Mold Transformers in DC Substations)

  • 박영;정호성;박철민;장순호
    • 전기학회논문지
    • /
    • 제60권9호
    • /
    • pp.1788-1794
    • /
    • 2011
  • The mold transformer is a complex and critical component of DC substations in Metro system. In this paper, a cost effective and intelligent condition monitoring system for mold transformers in DC substations was developed. This paper also provides an overview of the management program using PD (partial discharge) data on mold transformers. Prior to application of the proposed system to Metro DC substations, experiments were performed at the metro line substation located in Seoul and presented case studies for the use of the intelligent condition monitoring system for mold transformer in DC substations. The experiment results indicated that the developing system can be need in helping mange the risk of unexpected failure of mold type transformers.

Suggested Temperature Monitoring System for Distribution Transformers by Using Microcontroller Scheme

  • El-Gawad, Amal F. Abd
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2099-2104
    • /
    • 2015
  • The paper presents a monitoring system for the cooling of distribution transformers. The suggested system is controlled by a microcontroller scheme. The system is designed to control the oil temperature. It gives a solution to improve the cooling system by adding a number of fans especially for indoor transformers that are placed in badly-ventilated rooms. Also, the paper includes an alarm system with the possibility of tripping the transformer if it is necessary. The monitoring system consists of acquisition temperature sensor, and on-site unit. The hardware and software of the on-site unit are demonstrated with sufficient illustrations. Small prototype is constructed in the laboratory. Some laboratory experiments are carried out for examining the designed circuit by using Proteus Virtual System Modeling as well as for testing the prototype monitoring system. Concerning this research point, a study is carried out to evaluate the economic feasibility. The results are recorded and associated with many recommendations that may be valuable to electrical distribution (utility) companies.

Regression Analysis of Vibration Phenomenon on the Load Capacity and Elapsed Year of a Power Transformer

  • Kim, Young-Dal
    • 조명전기설비학회논문지
    • /
    • 제23권3호
    • /
    • pp.30-37
    • /
    • 2009
  • The majority of the causes for the failures of power transformers in operation are mechanical defects due to vibration. The vibration phenomenon was measured from the power transformers in operation in the substations. The vibration measurement was performed in a $6{\times}4$ structure on one side of each transformer. The vibrations of the measured points were presented in two and three dimensions and analyzed. The results, according to the elapsed year of the transformer and the load capacity to the transformer, were analyzed. These results could be used as basic data with which to establish vibration standards for power transformers. In addition, the load capacity-vibration phenomenon correlation was examined and regression analysis was performed to derive the estimation function. The vibration phenomenon according to the elapsed yeah was also estimated to derive the function. Then the analysis of the power transformers was used to set vibration standards for them based on the vibration data.