Browse > Article
http://dx.doi.org/10.5207/JIEIE.2009.23.3.030

Regression Analysis of Vibration Phenomenon on the Load Capacity and Elapsed Year of a Power Transformer  

Kim, Young-Dal (Department of Electrical Engineering, Hanbat National University)
Publication Information
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers / v.23, no.3, 2009 , pp. 30-37 More about this Journal
Abstract
The majority of the causes for the failures of power transformers in operation are mechanical defects due to vibration. The vibration phenomenon was measured from the power transformers in operation in the substations. The vibration measurement was performed in a $6{\times}4$ structure on one side of each transformer. The vibrations of the measured points were presented in two and three dimensions and analyzed. The results, according to the elapsed year of the transformer and the load capacity to the transformer, were analyzed. These results could be used as basic data with which to establish vibration standards for power transformers. In addition, the load capacity-vibration phenomenon correlation was examined and regression analysis was performed to derive the estimation function. The vibration phenomenon according to the elapsed yeah was also estimated to derive the function. Then the analysis of the power transformers was used to set vibration standards for them based on the vibration data.
Keywords
Transformer; Vibration; Correlation; Regression Analysis; Elapsed Year;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Gang Mou. "Modeling and Control of a Magnetostrictive System for High-precision Actuation at a Particular Frequency." Pp. 4-5.2002
2 "Acceptance Code for Gears, Part 2: Determination ofMechanical Vibrations of Gear Units During AcceptanceTesting." ISO Code 8579-2. 2007
3 David Jiles. "Introduction to Magnetism and Magnetic Materials." Chapman and Hall, pp. 89-106.1991
4 M. J. Dapino, R. C. Smith, and A. B. Flatau. "An Active and Structural Strain Model for Magnetostrictive Transducers." SPIE Symposium on Smart Structures and Materials, pp. 3329-3324. 1998
5 KS B 0714. 2001
6 Ji Shengchang, Luo Yongfen, and Li Yanming. "Research on the Extraction Technique for Transformers’ Core Fundamental Frequency Vibration Based on OLCM." IEEE Transactions on Power Delivery, Vol. 21, No. 4, pp. 1981-1988. 2006   DOI   ScienceOn
7 Ji Shengchang; Shan Ping, Li Yanming, Xu Dake, and Cao Junling. "The Vibration Measurement System for Monitoring Core and Winding Conditions of Power Transformers," Proceedings of the 2001 International Symposium on Electrical Insulating Materials (ISEIM 2001), pp. 849-852. 2001
8 Jeong Chung-yeong and Choi I-gyu. "Statistical Analysis Using SPSSWIN." Third Edition, Muyok Publishing. 1996