• Title/Summary/Keyword: toxic pollutants.

Search Result 223, Processing Time 0.027 seconds

A Study on Environmental Information System for Hazard Identification of Air Pollutants (환경정보 검색 시스템의 활용에 관한 연구 : 대기오염 물질의 위험성 확인을 중심으로)

  • Kim, Sun-Jeong;Shin, Dong-Chun;Chung, Yong;Koo, Ja-Kon
    • Journal of Environmental Impact Assessment
    • /
    • v.5 no.1
    • /
    • pp.107-121
    • /
    • 1996
  • The objective of this study is to establish the application method of environmental information system which is related to hazard identification for Health Risk Assessment. For establishing the environmental information system, fourteen hazardous chemicals were chosen and applicated to the database network such as RTKNET(Right Know Net), MSDS(Material Safety Data Sheets), TRI(Toxic Release Inventory), IRIS, AIRS, etc. The searching method of environmental information is classified to three sections such as the domestic commercial information company, international database agencies, and internet. Recently the importance of environmental information is being emphasized because it is essential 10 use database system in the field of environmental studies. Most of the foreign research organizations are communicating actively for information exchange, and the improvement of the quality of research. It is required to accumulate the data and develop them to database for future research.

  • PDF

Treatment of Oily Wastewater with WPO and CWO

  • Han, Mei;Chen, Yihui;He, Fang;Yu, Li
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.1
    • /
    • pp.68-71
    • /
    • 2014
  • Petroleum refining unavoidably generates large volumes of oily wastewater. The environmentally acceptable disposal of oily wastewater is a current challenge to the petroleum industry. Nowadays, more attentions have been focused on the treatment techniques of oily wastewater. Oily wastewater contained highly concentrated and toxic organic compounds. Wet peroxide oxidation (WPO) and catalytic wet oxidation (CWO) were applied to eliminate pollutants to examine the feasibility of the WPO/CWO of oily wastewater. The results indicated that more than 80% chemical oxygen demand (COD) removal from oily wastewater was achieved with CWO. Homogenous catalyst, $NaHCO_3$ and $Na_2CO_3$ and NaOH showed effective removal for pollutants in oily wastewater. Greater than 90% COD removal was achieved with WPO. It was concluded that WPO was a far more effective process for oily wastewater.

Heavy Metals of Landfilled Biomass and Their Environmental Standard, Including CCA-treated Wood for Eco-housing Materials (방부처리 목재를 포함한 토양매립 바이오메스의 중금속 함량과 안전성 문제)

  • Lim, Kie-Pyo;Lee, Jong-Tak;Bum, Jung-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.37-45
    • /
    • 2006
  • Recently, wood-framed houses has been built in the Korea for pension. Wood is good material for human healthy, while the construction lumbers are treated with preservative such as CCA (chromated copper arsenate), which contain some toxic elements for human body. However, if the waste woody biomass treated with various heavy metals, which has been collected from house construction or demolition, was fired in the field, and incinerated or landfilled after mass collection, such components will result in the toxic air pollutants in the burning or land fills, and spreaded into other areas. So the careful selection of wood and chemicals are required in advance for house construction, in particular, for environment-friendly housings. Therefore, this study was carried out to determine the content of toxic heavy metals in woody materials such as domestic hinoki and imported hemlock treated with CCA for housing materials, and the post-treated wood components such as organic fertilizer, sludge, dry-distilled charcoal and carbonized charcoal, to be returned finally into soil. The results are as follows. 1) The chemical analysis of toxic trace elements in various solid biomass required accurate control and management of laboratory environment, and reagents and water used, because of the error of data due to various foreign substances added in various processing and transporting steps. So a systematic analyzers was necessary to monitor the toxic pollutants of construction materials. 2) In particular, the biomass treated with industrial biological or thermal conditions such as sludge or charcoals was not fully dissolvable after third addition of $HNO_3$ and HF. 3) The natural woody materials such as organic fertilizer, sludge. and charcoals without any treatment of preservatives or heavy metal components were nontoxic in landfill because of the standard of organic fertilizers, even after thermal or biological treatments. 4) The CC A-treated wood for making the construction wood durable should not be landfilled, because of its higher contents of toxic metals than the criterion of organic fertilizer for agriculture or of natural environment. So the demolished waste should be treated separately from municipal wastes.

Development of Ozone Generator with using DC Voltage for Swinery (돈사 적용용 DC전압을 이용한 오존발생장치 개발에 관한 연구)

  • 문승일;채재우;이대엽;장기현;정태균
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.1
    • /
    • pp.77-84
    • /
    • 2003
  • HS, Ammonia, CH$_4$, VOCs, Microorganism, Bacteria etc produced from swineries or henhouses are known to prevent the growth of livestock. Moreover, they give an unpleasant feeling to the workers. In this study, a methodology to remove odors and toxic gases by oxidation of ozone was thus accomplished. However, most ozone generators which use the atmospheric surrounding air have problems of contamination of electrode for discharge. Therefore in this work, a wire-cylinder type plasma reactor with DC voltage has been used both in a laboratory scale test and in the real swinery to solve the existing problems. About 6 cm of electrode gap could decrease the attachment of dusts, humid aerosols and other polymers, which are contained in the air. This compact designed device could produce ozone to oxidize and remove the air pollutants. But the amount of ozone was not large enough to be harmful to human Health. Also, the concentration of ozone was able to be varied by the input voltage. which makes it available for the proposed system to be installed in various kinds of pig houses. With this device, at maximum 43 mg/㎥ (20 ppm) of ozone could be produced at 40 ㎸ input voltage (consumed energy was 0.1 Wh/㎥). A program was also made in this work to calculate the optimum parameters for design of a plasma reactor in wide range of conditions.

Protective Effects of YCY against Hepatotoxicity Induced by 2,3,7,8-Tetrachlorodibenzo-p-dioxin(TCDD) in Rats

  • Woon Kwon;Chai, Hee-youl;Young min Cho;Park, Ehn-kyoung;Kim, Ik-soo;Ryu, Kang-sun;Hwang, Seock-Yeon;Yun, Chi-Young;Kang, Jong-Koo
    • Proceedings of the Korean Society of Veterinary Pathology Conference
    • /
    • 2003.10a
    • /
    • pp.46-46
    • /
    • 2003
  • Polychlorinated dibenzo-p-dioxins (PCDDs) are widespread, persistant, and highly toxic environmental pollutants. TCDD is the most potent congener among PCDDs and the most thoroughly investigated model compound of this class of chemicals. These compounds elicit a variety of common biochemical and toxic response, including specific binding to the cytosolic AHR [1] and induces a variety of biological response ranging from induction of cytochrome P-450 1A (CYP1A) to liver damage and cancer [2]. This study was carried out to investigate the protective effects of YCY, extract of a cricket, Gryllus bimaculatus, on hepatotoxicity in 6-week-old SD rat exposured to TCDD (omitted)

  • PDF

A Numerical Study on the Short-term Dispersion of Toxic Gaseous and Solid Pollutant in an Open Atmosphere : Chemical Species, Temperature, Relative Velocity (고-기상 독성오염물질 단기 대기확산에 관한 수치해석적 연구 : 화학종, 온도, 상대속도)

  • 나혜령;이은주;장동순;서영태
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.3
    • /
    • pp.68-80
    • /
    • 1995
  • A series of parametric calculations have been performed in order to investigate the short-term and short-range plume and puff behavior of toxic gaseous and solid pollutant dispersion in an open atmosphere. The simulation is made by the use of the computer program developed by this laboratory, in which a control-volume based finite-difference method is used together with the SIMPLEC algorithm for the resolution of the pressure-velocity coupling appeared In Wavier-Stokes equation. The Reynolds stresses are solved by the standard two-equation k-$\varepsilon$ model modified for buoyancy together with the RNG(Renormalization Group) k-$\varepsilon$ model. The major parameters considered in this calculation are pollutant gas density and temperature, the relative velocity of pollutants to that of the surrounding atmospheric air, and particulate size and density together with the height released. The flow field is typically characterized by the formation of a strong recirculation region for the case of the low density gases such as $CH_4$ and air due to the strong buoyancy, while the flow is simply declining pattern toward the downstream ground for the case of heavy molecule like the $CH_2C1_2$and $CCl_4$, even for the high temperature, $200^{\circ}C$. The effect of gas temperature and velocity on the flow field together with the particle trajectory are presented and discussed in detail. In general, the results are physically acceptable and consistent.

  • PDF

Characteristics of Atmospheric Concentrations of Toxic Volatile Organic Compounds in Korea (II) - Seasonal and Locational Variations (국내 대기 중 독성 휘발성 유기화합물의 오염 특성(II) -계절 및 지역적 변동)

  • 백성옥;김배갑;박상곤
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.3
    • /
    • pp.207-217
    • /
    • 2002
  • This study was designed to investigate the characteristics of atmospheric concentrations of toxic volatile organic compounds (VOCs) in Korea. Target compounds included 1,3-butadiene, aromatics such as BTEX, and a number of carbonyl compounds. In this paper, as the second part of the study, the seasonal and locational concentrations of atmospheric VOCs were evaluated. Sampling was conducted seasonally at seven sampling sites. each of them representing a large urban area (commercial and residential), a small urban area (commercial and residential), an industrial area (a site within the complex and a residential), and a background place in Korea. In general, higher concentrations were found in the petro-chemical industrial site than other sites, while VOCs measured in commercial (heavy -traffic) sites were higher than residential sites. Seasonality of VOCs concentrations were not so much clear as other combustion related pollutants such as sulfur dioxide, indicating that the VOCs are emitted from a variety of sources, not only vehicle exhaust and point sources but fugitive emissions. Except the industrial site, the concentrations of VOCs measured in this study do not reveal any serious pollution status, since the levels did not exceed any existing ambient standards in the U.K. and/or Japan. However, the increasing number of petrol -powered vehicles and the rapid industrialization in Korea may result in the increased levels of VOCs concentrations in many large urban areas in the near future, if there is no appropriate programme implemented for the control of these compounds.

X-ray micro-imaging of the arsenic absorption of sap flow in xylem vessels of a fern brake (X-ray 영상기법을 이용한 비소 흡수가 고사리 내부 수액 거동에 미치는 영향 연구)

  • Lee, Jin-Pyoung;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.92-95
    • /
    • 2006
  • The global environment is deteriorating at an alarming rate despite of enhanced international environmental regulation. Many studies have been performed to reduce pollutants. Recently, phytoremediation, plant-based technology for the removal of toxic contaminants from soil, water, and air, has been receiving large attention. Arsenic-contaminated soil is one of the major pollutant sources fur drinking water. The fern brake (Pteris erotica) has been reported as a hyper-accumulate arsenic from soils. In this study, we investigated the arsenic absorption effect on sap flow inside xylem vessels of a fern brake. The synchrotron X-ray micro-imaging technique was employed to monitor flow inside the plant non-invasively. The captured phase-contrast X-ray images show both anatomy and transport of water inside the fern brake. The refilling process of water containing arsenic inside the xylem vessels of fern brake's leaves and stems was clearly observed. These results would provide important information needed fur understanding the mechanisms of accumulation, translocation, and transformation of toxic materials in plants.

  • PDF

Human Pluripotent Stem Cell-Derived Alveolar Epithelial Cells as a Tool to Assess Cytotoxicity of Particulate Matter and Cigarette Smoke Extract

  • Jung-Hyun Kim;Minje Kang;Ji-Hye Jung;Seung-Joon Lee;Seok-Ho Hong
    • Development and Reproduction
    • /
    • v.26 no.4
    • /
    • pp.155-163
    • /
    • 2022
  • Human pluripotent stem cells (hPSCs) can give rise to a vast array of differentiated derivatives, which have gained great attention in the field of in vitro toxicity evaluation. We have previously demonstrated that hPSC-derived alveolar epithelial cells (AECs) are phenotypically and functionally similar to primary AECs and could be more biologically relevant alternatives for assessing the potential toxic materials including in fine dust and cigarette smoking. Therefore, in this study, we employed hPSC-AECs to evaluate their responses to exposure of various concentrations of diesel particulate matter (dPM), cigarette smoke extract (CSE) and nicotine for 48 hrs in terms of cell death, inflammation, and oxidative stress. We found that all of these toxic materials significantly upregulated the transcription of pro-inflammatory cytokines such as IL-1α, IL-β, IL-6, and TNF-α. Furthermore, the exposure of dPM (100 ㎍/mL) strongly induced upregulation of genes related with cell death, inflammation, and oxidative stress compared with other concentrations of CSE and nicotine. These results suggest that hPSC-AECs could be a robust in vitro platform to evaluate pulmotoxicity of various air pollutants and harmful chemicals.

Respiratory Protection for LASER Users

  • Lee, Sang Joon;Chung, Phil-Sang;Chung, Sang Yong;Woo, Seung Hoon
    • Medical Lasers
    • /
    • v.8 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • The plume produced by vaporizing tissue with a laser contains a variety of contaminants called laser-generated air pollutants (LGACs). LGACs consist of a mixture of toxic gas components, biomicroparticles, dead and living cells, and viruses. Toxic odors and thick smoke from surgical incisions and the coagulation of tissues can irritate eyes and airways, as well as cause bronchial and pulmonary congestion. Because of the potential risk of the smoke, it is advisable to appropriately remove it from the surgical site. We recommend using a smoke evacuator to remove the smoke. Suction nozzles should be placed as close as possible to the surgical site in a range of 2 cm or less. In-line filters should be used between the inlet and outlet of the surgical site. All air filtration devices should be capable of removing particles below 0.1 microns in size. The filter pack should be handled according to infection control procedures in the operating room. The laser mask can be an auxiliary protective device if it is properly worn. Some smoke inhaled under the nose wrap or over the side of the mask will not be filtered. As in electrosurgical operations, a suitable mask should be worn while smoke is present.