Browse > Article

Development of Ozone Generator with using DC Voltage for Swinery  

문승일 (인하대학교 기계공학과)
채재우 (인하대학교 기계공학과)
이대엽 (인하대학교 기계공학과)
장기현 (린나이코리아 ㈜)
정태균 (부산 디지털정보기능대학)
Publication Information
Journal of Korean Society for Atmospheric Environment / v.19, no.1, 2003 , pp. 77-84 More about this Journal
Abstract
HS, Ammonia, CH$_4$, VOCs, Microorganism, Bacteria etc produced from swineries or henhouses are known to prevent the growth of livestock. Moreover, they give an unpleasant feeling to the workers. In this study, a methodology to remove odors and toxic gases by oxidation of ozone was thus accomplished. However, most ozone generators which use the atmospheric surrounding air have problems of contamination of electrode for discharge. Therefore in this work, a wire-cylinder type plasma reactor with DC voltage has been used both in a laboratory scale test and in the real swinery to solve the existing problems. About 6 cm of electrode gap could decrease the attachment of dusts, humid aerosols and other polymers, which are contained in the air. This compact designed device could produce ozone to oxidize and remove the air pollutants. But the amount of ozone was not large enough to be harmful to human Health. Also, the concentration of ozone was able to be varied by the input voltage. which makes it available for the proposed system to be installed in various kinds of pig houses. With this device, at maximum 43 mg/㎥ (20 ppm) of ozone could be produced at 40 ㎸ input voltage (consumed energy was 0.1 Wh/㎥). A program was also made in this work to calculate the optimum parameters for design of a plasma reactor in wide range of conditions.
Keywords
Ozone generator; Plasma; Elcetrode; Microorganism; Toxic gases;
Citations & Related Records
연도 인용수 순위
  • Reference
1 오존과 촉매에 의한 유기물 및 질소의 고도처리 장치 /
[ 산업자원부 ] / 최종보고서
2 저온플라즈마를 이용한 실내 공기 오염물질 저감에 관한 연구 /
[ 이창민 ] / 석사논문
3 /
[ Yuri P. Raizer ] / Gas Discharge Physics
4 오존발생장치의 국내 개발과 오존발생량 평가 /
[ 김선태;김학민 ] / 한국대기보전학회 춘계학술대회
5 Domestic allergens in public places Ⅲ:house dust mist, cat, dog and cockroach allergens in british hospitals /
[ Custovic, A.;A. Fletcher;C. A. Pkckering ] / Clinical and Experimental Allergy   DOI   ScienceOn
6 /
[ 이덕출;황면환 ] / 고전압플라즈마공학
7 Bactericidal Effects of High Airborne Ozone Con-centrations on Escherichia coli and Staphylococcus aureus /
[ Kowalski, W. J.;W. P. Bahnfleth;T. S. Whittam ] / Ozone Science & Engineering, 0191-9512/98,20
8 /
[ 서국철;강도열 ] / 신편고전압공학
9 오존에 의한 PAHs 오염토양 복원 연구 /
[ 임형남;김지연;최희철 ] / 대한환경공학회지   과학기술학회마을
10 /
[] / Ozone Solutions
11 Improvement of Ozone Yielding Rate in Atmospheric Pressure Barrier Discharges Using a Time Modulated Power Supply /
[ Kazuyuki, Ohe(etc.) ] / IEEE Transaction of plasma Science