• 제목/요약/키워드: total output

검색결과 1,524건 처리시간 0.029초

초음파트랜스듀서의 재질에 따른 실출력과 인체모사조직의 온열효과에 관한 연구 (A Study on the Actual Output and Thermal Effect in Tissue Mimicking Phantom by the Material of the Ultrasonic Transducer)

  • 유상현;최원재;이승원
    • 대한물리의학회지
    • /
    • 제10권1호
    • /
    • pp.91-97
    • /
    • 2015
  • PURPOSE: In this study investigated the thermal effect in tissue mimicking phantom by the material of the ultrasonic transducer in low intensity sonication. METHODS: The material of the ultrasonic transducer was made of ceramic, stainless steel, aluminum. Korea Testing Laboratory was measured of the three kinds of materials the total output of the ultrasonic transducer. Each material was measured core temperature and the actual output depending on the type of transducer. Agarose tissue mimicking phantom and silicone tissue mimicking phantom was made. Transducers made of three kinds of materials were emitted in the phantom. It is shown as a graph about time and temperature and the surface temperature rising speed and deep temperature rise rate was investigated. RESULTS: Ceramic transducers were highest output. Higher than the stainless steel transducer, aluminum had the lowest total output. Deep temperature was the highest in the ceramic transducer, and the surface temperature was the highest in the stainless steel transducer. Thermal images of ceramic transducer showed that a valid output is formed deeper wider than the metal. CONCLUSION: Ceramic transducer is confirmed the excellence than the metal transducer in deep thermal effect and the actual output of the ultrasound.

흰쥐에서 대상회전 제거가 위액분비에 미치는 영향 (Effect of Cingulate Cortical Ablation upon Gastric Secretion in Rats)

  • 박형진;안병태;조양혁
    • The Korean Journal of Physiology
    • /
    • 제11권2호
    • /
    • pp.67-71
    • /
    • 1977
  • This study was undertaken to investigate the effect of cingulate cortical ablation upon gastric secretion and its components in rats. 23 male rats were divided into the cingulate(N=9) and the operated control(N= 14) groups. Cingulate cortex was ablated through a slit-shaped opening(1 mm in width, 5 mm in length) which was made symmetrically on both sides of, and parallel to, the sagittal suture by removing a bone flap from frontal bone on each side. In the operated control group, the surgical procedure was ended by the removal of the bone flap. Under light ether anesthesia, experimental animals were placed in a restraining jacket of fine mesh wire and gastric juice was collected for 5 hours via a canula which had been inserted through the anterior abdominal wall into the antral portion of the lumen of the stomach. Volume of the gastric juice was measured, and total acid output and free acid output were titrated with 0.04 N NaOH solution by using phenolphthalein and Topfer's reagent at indicator, and chloride ion output was estimated by means of chloridometer. Results obtained were that volume, total acid output, free acid output and chloride ion output of the gastric juice were higher significantly in the cingulate group than in the operated control group. It is inferred from the above results that the cingulate cortex exerts a fascilitatory influence upon gastric secretion and acid output in rats.

  • PDF

Mismatching Problem between Generic Pole-assignabilities by Static Output Feedback and Dynamic Output Feedback in Linear Systems

  • Kim Su-Wood
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권1호
    • /
    • pp.56-69
    • /
    • 2005
  • In this paper, it is clearly shown that the two well-known necessary and sufficient conditions mp n as generic static output feedback pole-assignment and mp + d(m+p) n+d as generic minimum d-th order dynamic output feedback pole-assignment on complex field, unbelievably, do not match up each other in strictly proper linear systems. For the analysis, a diagram analysis is newly created (which is defined by the analysis of 'convoluted rectangular/dot diagrams' constructed via node-branch conversion of the signal flow graphs of output feedback gain loops). Under this diagram analysis, it is proved that the minimum d-th order dynamic output feedback compensator for pole-assignment in m-input, p-output, n-th order systems is quantitatively decomposed into static output feedback compensator and its associated d number of arbitrary 1st order dynamic elements in augmented (m+d)-input, (p+d)-output, (n+d)-th order systems. Total configuration of the mismatched data is presented in a Table.

MOVING-ACTUATOR TYPE 인공심장의 심박출 조절에 대한 자동 제어방법 (Automatic Control System on Cardiac Output Regulation for the Moving Actuator Type Total Artificial Heart)

  • 김원곤
    • Journal of Chest Surgery
    • /
    • 제28권6호
    • /
    • pp.542-548
    • /
    • 1995
  • The goal of this study is to develop an effective control system for cardiac output regulation based upon the preload and afterload conditions without any transducers and compliance chambers in the moving actuator type total artificial heart. Motor current waveforms during the actuator movement are used as an input to the automatic control algorithm. While the current waveform analysis is performed, the stroke length and velocity of the actuator are gradually increased up to the maximum pump output level. If the diastolic filling rate of either right or left pump begins to exceed the venous return, atrial collapse will occur. Since the diastolic suction acts as a load to the motor, this critical condition can be detected by analyzing the motor current waveforms. Every time this detection criterion is met, the control algorithm decreases the stroke velocity and length of the actuator step by step just below the critical detection level. Then, they start to increase. In this way the maximum pump output under given venous return can be achieved. Additionally the control algorithm provides some degree of afterload sensitivity. If the aortic pressure is detected to exceed 120 mmHg, the stroke length and velocity decrease in the same way as the response to the preload. Left-right pump output balance is maintained by proper adjustment of the asymmetry of the stroke angle. In the mock circulatory test, this control system worked well and there was a considerable range of stroke volume difference with adjustment of the asymmetry value. Two ovine experiments were performed. It was confirmed that the required cardiac output regulation according to the venous return could be achieved with adequate detection of diastolic function, at least in the in vivo short-term survival cases[2-3 days . We conclude that this control algorithm is a promising method to regulate cardiac output in the moving actuator type total artificial heart.

  • PDF

Investigation of Single-Input Multiple-Output Wireless Power Transfer Systems Based on Optimization of Receiver Loads for Maximum Efficiencies

  • Kim, Sejin;Hwang, Sungyoun;Kim, Sanghoek;Lee, Bomson
    • Journal of electromagnetic engineering and science
    • /
    • 제18권3호
    • /
    • pp.145-153
    • /
    • 2018
  • In this paper, the efficiency of single-input multiple-output (SIMO) wireless power transfer systems is examined. Closed-form solutions for the receiver loads that maximize either the total efficiency or the efficiency for a specific receiver are derived. They are validated with the solutions obtained using genetic algorithm (GA) optimization. The optimum load values required to maximize the total efficiency are found to be identical for all the receivers. Alternatively, the loads of receivers can be adjusted to deliver power selectively to a receiver of interest. The total efficiency is not significantly affected by this selective power distribution. A SIMO system is fabricated and tested; the measured efficiency matches closely with the efficiency obtained from the theory.

전동차용 전원장치의 출력전압 제어 안정성 향상 (Stability Improvement of Output Voltage Control on the Power Supply for Railways)

  • 서광덕
    • 조명전기설비학회논문지
    • /
    • 제13권4호
    • /
    • pp.134-141
    • /
    • 1999
  • 본 논문은 전동차량용 전원장치의 출력전압 제어 안정성을 향상시키기 위한 연구이다. 입력전압 변동 및 부하 변동 등 과도상태시 출력 정전압 제어를 수행할 경우, L-C 필터부에서 공진이 발생함으로써 출력전압이 흔들리고 시스템이 불안해진다. 본 논문에서, 출력전압제어의 안정성을 확보하기 위해 주필터부에 공진을 억제하는 댐핑회로를 새롭게 제안하고, 이에 적합한 제어방법을 소개한다. 제안한 댐핑회로는 R-L로서 소형이고 간단히 구성된다. 제어기에는 과도상태분의 궤환제어와 대역저지필터를 적용한다. 또한 전력회로는 3레벨 PWM방식을 적용하였다. 이로서 과도상태에서 출력전압의 흔들림없이 변동폭을 10[%]이하로 제어할 수 있었으며, 정상상태의 출력 전압 왜형율도 3[%]이하로 감소시켰다.

  • PDF

Single-Delta Bridge Cell MMC의 전압합성을 위한 PWM 반송파 형태에 따른 출력전압의 THD 분석 (THD Analysis of Output Voltage According to PWM Carriers in Single-Delta Bridge Cell MMC)

  • 김재명;정재정
    • 전력전자학회논문지
    • /
    • 제27권6호
    • /
    • pp.526-534
    • /
    • 2022
  • The modular multilevel converter (MMC) has been widely applied to various industrial areas because of its various advantages and structural characteristics. Therefore, many methods for synthesizing the output voltage of MMC have been studied. Among these methods, phase-shifted pulse width modulation (PSPWM) is frequently used in MMC systems because it has diverse merits, such as excellent output qualities even with a small number of cells and uniform power distribution among cells. In this study, the total harmonic distortion (THD) of the output voltage is analyzed in accordance with the number of cells in one arm of a single-delta bridge cell MMC in order to compare PSPWM methods in terms of the THD of the output voltage. The physical characteristics of the triangle and sawtooth carrier waves used for the PSPWM and the mathematical modeling of output voltage are introduced. Then, the obtained results are verified through real-time simulation of a 1 MW single-delta bridge cell MMC system.

A Cascaded Multilevel Inverter Using Bidirectional H-bridge Modules

  • Kang, Feel-Soon;Joung, Yeun-Ho
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권4호
    • /
    • pp.448-456
    • /
    • 2012
  • This paper presents a multilevel inverter configuration which is designed by insertion of a bidirectional switch between capacitive voltage sources and a conventional H-bridge module. The modified inverter can produce a better sinusoidal waveform by increasing the number of output voltage levels. By serial connection of two modified H-bridge modules, it is possible to produce 9 output voltage levels including zero. There are 24 basic switching patterns with the 9 output voltage levels. Among the patterns, we select the 2 most efficient switching patterns to get a lower switching loss and minimum dv/dt stress. We then analyze characteristics of Total Harmonic Distortion (THD) of the output voltage with variation of input voltage by computer-aided simulations and experiments.

Fuzzy Control Method for Balancing Left and Right Cardiac Output in Total Artificial Heart

  • Shin, In-Sun;Kim, Bo-Yeon;Lee, Sang-Hoon;Choi, Jin-Wook;Min, Byoung-Goo
    • 대한의용생체공학회:의공학회지
    • /
    • 제12권3호
    • /
    • pp.203-208
    • /
    • 1991
  • Balancing left/right cardiac output is essential for the automatic control of total artificial hearts(TAH). A fuzzy logic-based control method is presented. We use left atrial pressure( LAP) ann right a'rial pressure( RAP ) as indicators for left/right balancing. The fuzzy controller has four input variables which are measured LAP and RAP and their gradients. Desired variations in left cardiac output(LCO) and right cardiac output(RCO) are cal- culated to keep LAP and RAP within the Physiological limlts. Computer simulations were performed to adjust fuzzy membership functions for variables and verify this control method. Results from simulations showed that LAP and RAP returned to the physiological limits while AoP and PAP stayed within the physiological limits.

  • PDF

소셜네트워크분석(SNA)을 활용한 수상운송서비스 무역 네트워크 분석 연구 (A Study on International Trade of Water Transport Service using Social Network Analysis)

  • 박선율
    • 무역학회지
    • /
    • 제47권3호
    • /
    • pp.75-92
    • /
    • 2022
  • This study aims to analyze the International trade network of Water transport service using Social Network Analysis for defining the status of Korean Water transport industry. This study use World Input-Output Table of Asian Development Bank from 2000 to 2020 and build the International trade matrix of Water transport service from that. Therefore, this study analyze Out-degree centrality, In-degree centrality and betweenness centrality of Korea and other main countries in the matrix of World Water transport industry. As a result, Korea rank above 10th in the all centralities and the total output also rank 8th in the world, therefore, this study show the importance of Korean Water transport industry in the world. However, Singapore has the highest centrality in the world, even though China has the largest Total output among 63 countries.