Automatic Control System on Cardiac Output Regulation for the Moving Actuator Type Total Artificial Heart

MOVING-ACTUATOR TYPE 인공심장의 심박출 조절에 대한 자동 제어방법

  • Published : 1995.06.01

Abstract

The goal of this study is to develop an effective control system for cardiac output regulation based upon the preload and afterload conditions without any transducers and compliance chambers in the moving actuator type total artificial heart. Motor current waveforms during the actuator movement are used as an input to the automatic control algorithm. While the current waveform analysis is performed, the stroke length and velocity of the actuator are gradually increased up to the maximum pump output level. If the diastolic filling rate of either right or left pump begins to exceed the venous return, atrial collapse will occur. Since the diastolic suction acts as a load to the motor, this critical condition can be detected by analyzing the motor current waveforms. Every time this detection criterion is met, the control algorithm decreases the stroke velocity and length of the actuator step by step just below the critical detection level. Then, they start to increase. In this way the maximum pump output under given venous return can be achieved. Additionally the control algorithm provides some degree of afterload sensitivity. If the aortic pressure is detected to exceed 120 mmHg, the stroke length and velocity decrease in the same way as the response to the preload. Left-right pump output balance is maintained by proper adjustment of the asymmetry of the stroke angle. In the mock circulatory test, this control system worked well and there was a considerable range of stroke volume difference with adjustment of the asymmetry value. Two ovine experiments were performed. It was confirmed that the required cardiac output regulation according to the venous return could be achieved with adequate detection of diastolic function, at least in the in vivo short-term survival cases[2-3 days . We conclude that this control algorithm is a promising method to regulate cardiac output in the moving actuator type total artificial heart.

Keywords

References

  1. ASAIO J v.38 Use of total artificial hearts : summary of world experience, 1969-1991 Johnson,K.E.;Liska,M.B.;Joyce,L.D.;Emery,R.W.
  2. Cardiac Surgery v.7 no.2 Future prostects for a totally imolantavle artificial heart Khanwilkar,P.S.;Olsen,D.B.;Ott,R.A.;Gutfinger,D.E.;Grazzaniga,A.B.
  3. Artif organs v.15 no.5 Control systems for the electric heart White,R.K.;Olsen,D.B.
  4. ASAIO Trans v.38 Cardiac output regulation in the moving actuator total artificial heart without a compliance chamber Kim,H.C.;Min,B.G.
  5. IEEE Trans Biomed Eng v.37 Permanent circulatory support system at the Pennsylvania University Weiss,W.J.;Rosenbert,G.;Snyder,A.J.(et al.)
  6. Artif Organs v.12 In vitro development of outomatic control for the actively filled electrohydraulic heart Lioi,A.P.;Orth,J.L.;Crump,K.R.(et al.)
  7. Trans Am Soc Artif Organs v.ⅩⅩⅤ A microprocessor based control system for the artifical heart Vajapeyam,B.;McInnis,B.C.;Everett,R.L.;Vakamudi,A.K.;Akutsu,T.
  8. Trans Am Soc Artif Intern Organs v.ⅩⅩⅩⅠ Development of hemoglobin oxygen optical sensors for automatic control of arrificial heart output Takatani,S.;Tanaka,T.;Nakatani,t.(et al.)
  9. Trans Am Soc Artif Intern Organs v.35 A unique left-right flow imbalance compensation scheme for an implantable total artificial heart Kung,R.T.;Ochs,B.;Singh,P.I.
  10. Progress in artificial organs-1985 Volume stability of the gas-filled intrathoracic compliance chamber Smith,W.A.;Kaneko,S.;Snow,J.(et al.);Nose,Y.(ed.);Kjellstrand,C.(ed.);Ivanovich,P.(ed.)
  11. Ann Surg v.212 An electric artificial heart for artificial heart Pierce,W.S.;Rosenberg,G.;Snyder,A,J.;Pae,W.E.
  12. Int J Artif organs v.14 Right-left ventricular output balance in the totally implantable artificial heart Olsen,D.B.;White,R.K.;Long,J.;Khanwilkar,P.
  13. Circulatory physiology:cardiac output and its regulation Regulation of cardiac output from an artificial heart Guyton,A.C.;Jones,C.E.;Coleman,T.G.;Guyton,A.C.(ed.);Jones,C.e.(ed.);Coleman,T.G.(ed.)
  14. Ann Biochemical Engineering v.2 Design of a hydraulic analog of the circulatory system for evaluating artificial hearts Donovan,F.M.
  15. 대흉회지 v.28 양에서 시행한 이동작 동기 형태(MOVING ACTUATOR TYPE)인공심장의 삽입실험 김원곤;원용순;안혁;민병구;노준량
  16. J Thorac Cardiovasc Surg v.108 the cleverand clinic-Nimbus total artificial heart, design and in vitro function Massielo,A.;Raymond,K.;Butler,K.;Himley,S.;Chen,J.;McCarthy,M.
  17. ASAIO Trans v.31 Factors affectiong left-right output differences in artificial heart implanted animals Tanaka,T.;Takatani,S.;Umezu,M.(et al.)
  18. Artificial Heart 4 In vitro development of automatic control for the moving-actuator type artificial heart(TAH) Kim,H.C.;Min,B.G.;Akutsu,T.(ed.);Koyanagi,H.(ed.)