• 제목/요약/키워드: total harmonic

검색결과 567건 처리시간 0.023초

A New Assessment for the Total Harmonic Contributions at the Point of Common Coupling

  • Han, Jong-Hoon;Lee, Kyebyung;Song, Chong Suk;Jang, Gilsoo;Byeon, Gilsung;Park, Chang-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.6-14
    • /
    • 2014
  • A new method to determine the total harmonic contributions of several customers and the utility at the point of common coupling is presented. The proposed method can quantify the individual harmonic impact of each suspicious harmonic source at the point of common coupling. The individual harmonic impact index is then used to assess the total harmonic contribution of each harmonic source. This index can be calculated by the results processed from instantaneous harmonic voltage and current phasor values. The results demonstrate the performance of the proposed method in terms of steady-state accuracy and response to time-varying operating conditions. The proposed index can be used for billing purposes to control harmonic distortion levels in power systems.

GIC 적용 대역통과필터를 이용한 컴퓨터 부하의 직렬 아크고장 전류 우수고조파 분석 (Even Harmonic Analysis of Series Arc-fault Current Using BPF of GIC Application in Computer)

  • 고원식;문원식;방선배;김재철
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1554-1560
    • /
    • 2012
  • In this paper, the even harmonic current(2nd, 4th, 6th, 8th) of the arc fault current and normal current were measured in computer load and analyzed. The BPF with GIC was developed to detection of harmonic, the exact center frequency and a high degree of sharpness could be easily obtained. The total even harmonic distortion due to series arc fault in computer load was 31.2%, this value was increased 3.9 times better than the total even harmonic distortion of normal current. The results of analysis of arc fault current RMS variation rate and Peak variation rate per half-cycle, The RMS average variation rate are as follows ; the 2nd harmonic was 0.24, the 4th harmonic was 0.15, the 6th harmonic was 0.19, the 8th harmonic was 0.25, respectively. The Peak average variation rate are as follows ; the 2nd harmonic was 0.19, the 4th harmonic was 0.12, the 6th harmonic was 0.13, the 8th harmonic was 0.15, respectively. The results of this analysis utilize data to detect of series arc fault on wiring of computer load.

Harmonic Analysis of a Modular Multilevel Converter Using Double Fourier Series

  • Quach, Ngoc-Thinh;Chae, Sang Heon;Ahn, Jin Hong;Kim, Eel-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.298-306
    • /
    • 2018
  • This paper presents a harmonic analysis of the modular multilevel converter (MMC) using a double Fourier series (DFS) algorithm. First, the application of DFS for harmonic calculation in the MMC is made by considering the effect of arm inductor. The analytical results are then confirmed by comparing with the simulation results of using the fast Fourier transform (FFT) algorithm. Finally, distribution of harmonics and total harmonic distortion (THD) in the MMC will be analyzed in three cases: harmonics versus number of levels of MMC, harmonics versus total switching frequency and harmonics versus modulation index. The simulation results are performed in the PSCAD/EMTDC simulation program in order to verify the analytical results obtained by Matlab programming.

배전 시스템의 고조파 분석 및 모델링에 관한 연구 (A Study on Harmonics Analysis and Modelling for Distribution System)

  • 왕용필;정종원;정동일
    • 조명전기설비학회논문지
    • /
    • 제21권3호
    • /
    • pp.62-68
    • /
    • 2007
  • 최근 전력 전자 응용 기기의 사용증가로 비선형 특성 부하에 의한 고조파가 상당히 발생하고 있으며, 이에 의한 영향으로 배전시스템의 변압기 열화, 소자의 고장, 통신 간섭 등의 여러 가지 문제를 발생시키고 있다. 따라서 배전 시스템에서의 고조파 수준과 전달특성을 정확하게 분석하기 위하여 배전시스템의 효과적인 실측정과 모델링에 관한 연구가 필요한 실정이다. 본 논문에서는 고조파 관리기준 IEC61000-3-6 토대로 배전 시스템의 고조파 특성을 해석하기 위하여 공통 결합점(Point of Common Coupling : PCC)을 선택하였다. 실 배전 시스템의 PCC 지점에서 고조파 전압, 전류를 측정하여, 고조파 분포, 비선형 부하 성분 및 고조파 전압, 전류 왜형률 (Voltage/Current Total Harmonic Distortion: VTHD/ITHD)을 분석하였다. 또한 정상상태에서 고조파 임피던스, 전압, 전류을 해석을 통하여 실 배전시스템을 효과적이고 정확하게 모델링 되었을 확인하였다. 또한 고조파 전류원 발생시에 고조파 전압, 전류를 비교 분석하여 고조파 전달특성을 조사하였다.

옵셋 전압을 이용한 일정 스위칭 주파수의 Random PWM 기법 (A Novel Random PWM Technique with a Constant Switching Frequency Utilizing an Offset Voltage)

  • 김도겸;김상훈
    • 전력전자학회논문지
    • /
    • 제22권1호
    • /
    • pp.67-74
    • /
    • 2017
  • This study proposes a novel random pulse-width modulation (PWM) technique with a constant switching frequency utilizing a random offset voltage. The proposed PWM technique spreads switching harmonics by varying the position of an active voltage vector without a switching frequency variation. The implementation of the proposed PWM technique is simple because it does not require additional hardware and complex algorithm. The proposed random PWM technique is compared with the conventional PWM technique on the factors of harmonic spectrum, total harmonic distortion, and harmonic spread factor to confirm the harmonic spread effect. The validity of the proposed method is verified by simulations and experiments on a three-phase inverter drive system.

Generalized Selective Harmonic Elimination Modulation for Transistor-Clamped H-Bridge Multilevel Inverter

  • Halim, Wahidah Abd.;Rahim, Nasrudin Abd.;Azri, Maaspaliza
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.964-973
    • /
    • 2015
  • This paper presents a simple approach for the selective harmonic elimination (SHE) of multilevel inverter based on the transistor-clamped H-bridge (TCHB) family. The SHE modulation is derived from the sinusoidal voltage-angle equal criteria corresponding to the optimized switching angles. The switching angles are computed offline by solving transcendental non-linear equations characterizing the harmonic contents using the Newton-Raphson method to produce an optimum stepped output. Simulation and experimental tests are conducted for verification of the analytical solutions. An Altera DE2 field-programmable gate array (FPGA) board is used as the digital controller device in order to verify the proposed SHE modulation in real-time applications. An analysis of the voltage total harmonic distortion (THD) has been obtained for multiple output voltage cases. In terms of the THD, the results showed that the higher the number of output levels, the lower the THD due to an increase number of harmonic orders being eliminated.

종합 고조파 왜율 일정 제어를 위한 삼상 NPC PWM 인버어터의 제어 기법 (The Control Technique of 3 Phase NPC PWM Inverter to control fixed Total Harmonic Distortion)

  • 송언빈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.565-567
    • /
    • 1994
  • This paper presents a software based NPC PWM inverter control technique to eliminate the harmonics in the output waveforms of inverter. The proposed control technique is able to keep down total harmonic distortion and significantly improve the performance of the inverter. In the control node where the frequency ratio is 36 and the modulation index is $1.2\sim2.0$, the proposed inverter has been operated wi thin 5% Total Harmonic Distortion.

  • PDF

TOTAL CURVATURE FOR SOME MINIMAL SURFACES

  • Jun, Sook Heui
    • Korean Journal of Mathematics
    • /
    • 제7권2호
    • /
    • pp.285-289
    • /
    • 1999
  • In this paper, we estimate the total curvature of non-parametric minimal surfaces by using the properties of univalent harmonic mappings defined on ${\Delta}=\{z:{\mid}z:{\mid}>1\}$.

  • PDF

6고조파 주입 PWM을 이용한 3상 승압형 컨버터 고조파저감 (Harmonic Reduction in Three-Phase Boost Converter with Six Harmonic Injected PWM)

  • 이정훈;김재문;안정준;이정호;원충연;정동효
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.327-332
    • /
    • 1999
  • In this paper, six harmonic injection PWM method for reducing total harmonic distortion in single switch three phase discontinuous conduction mode boost converter is presented. In the proposed method, periodic six harmonic voltage is injected in the control circuit to vary the duty ratio of the converter switch within a line cycle so that the fifth order harmonic of the input current is reduced. Experimental results are verified by converter operating at 400V/6kW with three phase 140V~220V input.

  • PDF