• 제목/요약/키워드: tooth crack

검색결과 50건 처리시간 0.022초

Diagnosis in Beding Fatigue of Spur Gear Teeth

  • Sentoku, Hirofumi;Tokuda, Takashi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국제학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.307-311
    • /
    • 1993
  • Research concerning gears included in rotating machines has been reported using the acoustic emission (AE) method, however, almost no research has been conducted using the AE method in regard to running gears in a bending fatigue processor spur gear teeth. Therefore, in this report, a power circulating-type gear testing machine was used and AE signals and crack length were measured in the bending fatigue process of case-hardened spur gear. Furthermore, the envelope of the AE signal was detected and various analysis were carried out in this data. In the course of the experiments, the following results were observed : the AE signal envelope consists mainly of contact frequency component and twice as many as this;two peaks of AE appear in each tooth contact by the tip corner contact ; as a result of the severe tip corner contact ; as a result of the severe tip corner contact with the sudden increase of crack length, AE signal becomes large.

  • PDF

파괴역학을 기초로 한 침탄치차의 굽힘강도에 미치는 쇼트피닝(Shot Peening)의 효과에 관한 연구 (The Effect of Shot Peening on the Bending Strength of Carburized Spur Gear Teeth Based on Fracture Mechanics)

  • S.K.Lyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제21권5호
    • /
    • pp.512-521
    • /
    • 1997
  • This paper deals with an evaluation of the residual stress due to shot peening induced in a car¬burized gear tooth and its application to the fatigue crack propagation problem. The residual stress is estimated based on the assumption that the main cause of residual stress is the volume difference between the case and core due to martensitic transformation in cooling, and the influ¬ence of both the reduction of retained austenite and the strain in the surface layer induced by shot peening are considered. The reliability of the method is examined by comparison with stresses measured by the X-ray diffraction method. The stresses intensity factors are computed by the influence function method and the reduction of the factor due to the residual stress is demonstrat¬ed and discussed based on the fracture mechanics.

  • PDF

초음파 다이아몬드 기구의 상아질 삭제 효과, 치근단 역충전 와동 형성효율 및 치질에의 영향 (EFFICIENCY OF DENTIN CUTTING AND ROOT -END RETROCAVITY PREPARATION USING ULTRASONIC DIAMOND INSTRUMENTS AND THEIR INFLUENCE ON TOOTH STRUCTURE)

  • 임춘희;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.54-67
    • /
    • 1998
  • 치근단 역충전 와동 형성을 위한 초음파 다이아몬드 기구의 임상적 적용의 타당성 및 특성을 평가하기 위해, 다이아몬드 기구의 상아질 삭제능력, 역충전 외동 형성효율 및 치질에 미치는 영향을 관찰하여 스테인레스 스틸 기구와 비교, 평가하였다. 치근단 역충전 와동 형성시 다이아몬드 기구와 스테인레스 스틸 기구를 발거된 소의 치아에서 노출시킨 상아질 표변에 일정한 출력과 시간 조건 하에서 작동시켜 상아질 표면으로부터의 삭제된 깊이를 측정하였다. 역충전 와동 형성효율을 평가하기 위하여 발거된 상악 제 1 대구치 치근에서 근관을 형성하고 gutta-percha로 충전한 다음 근단 3mm부위를 치아 장축에 직각되게 절제하고 초음파 기구의 와동형성 소요 시간 및 소요 stroke 수를 측정하였다. 초음파 기구를 이용한 와동 형성이 치질에 미치는 영향을 평가하기 위하여 초음파 와동 형성 전후의 치근단부 치질의 균열 발생빈도를 측정, 평가하여 다음과 같은 결과를 얻었다. $\cdot$ 저출력 또는 중출력에서 그리고 노출된 상아질에 수직 또는 수평으로 기구를 적용한 경우 모두에서, 다이아몬드 기구가 스테인레스 스틸 기구에 비해 높은 상아질 삭제효과를 나타내었다(p<0.01). $\cdot$ 초음파기구를 상아질 표면에 수직으로 적용한 경우에 출력이 높을수록 상아질 삭제효과가 우수하였으며, 수평으로 적용한 경우에는 출력에 따른 유의한 증가가 나타나지 않았다(p<0.01). $\cdot$ 중출력에서는 다이아몬드 기구가 스테인레스 스틸 기구에 비해 와동형시 소요되는 stroke 수와 시간으로 본 와동형성효율이 유의하게 우수하게 나타났다(p<0.05). $\cdot$ 저출력에서는 다이아몬드 기구가 스테인레스 스틸 기구에 비해 외동형성 후 치근단 균열 발생빈도가 유의하게 적게 나타났다(p<0.01).

  • PDF

설진 유효 분석을 위한 혀의 기하정보 추출 방법 (Extraction Method of Geometry Information for Effective Analysis in Tongue Diagnosis)

  • 은성종;김재승;김근호;황보택근
    • 한국콘텐츠학회논문지
    • /
    • 제11권12호
    • /
    • pp.522-532
    • /
    • 2011
  • 한의학에서 혀의 상태는 인체의 건강 상태를 진단하는 중요한 지표로 활용된다. 이러한 혀의 상태를 진단하는 설진은 편리할 뿐 아니라 비침습적이므로, 한의학에서 널리 활용되고 있다. 그러나 설진은 객관화와 표준화라는 관점에서 문제가 있으며, 한의사의 의사결정에 도움을 줄 수 있는 도구도 부족한 실정이다. 본 논문은 이러한 문제점을 해결하기 위해, 설진 유효 분석을 위한 혀의 기하정보를 자동으로 계산하는 방법을 제안한다. 제안된 방법은 개선된 스네이크(Snake) 방법을 통해 혀를 검출하고 컨벡스 헐(Convex Hull)과 인페인팅 방법을 이용하여 객관적인 기하 정보를 추출하였다. 제안 알고리즘의 성능평가로 치흔의 경우 7.2%, 균열의 경우 8.5%의 영역 차이 비율로 안정적인 결과가 도출되었다.

큐레이(Q-ray)와 티스캔(T-scan)을 사용한 치아균열증후군(cracked tooth syndrome)과 교합 사이의 상관관계에 대한 분석 (Analysis of relationship between cracked tooth syndrome and occlusion using Q-ray and T-scan)

  • 안도관;최진우;김유성;표세욱;김희경
    • 대한치과보철학회지
    • /
    • 제59권3호
    • /
    • pp.271-280
    • /
    • 2021
  • 목적: 본 연구의 목적은 큐레이(Q-ray)와 티스캔(T-scan)을 사용하여 치아균열증후군(cracked tooth syndrome)과 교합 사이의 상관관계를 평가하는 것이다. 대상 및 방법: 2019년 3월 1일부터 2020년 12월 31일까지 아주대학교병원 치과진료센터 치과보철과에 내원한 환자 중 실험대상 포함기준을 만족하며 치아균열증후군으로 진단된 대구치(실험군)를 1개 이상 가지고 있으나 동일 악궁 반대측에는 정상 치아(대조군)를 가진 환자 51명을 대상으로 하였다. 실험군과 대조군 치아의 사진을 Q-ray pen을 이용해 촬영하여 최대형광소실도(ΔFmax)와 최대적색형광도(ΔRmax)을 측정하였고 T-scan 검사를 통해 실험군과 대조군 치아의 상대적 교합강도 및 편심위운동시 이개시간을 측정하였다. Mann-Whitney U test를 통해 실험군과 대조군 사이의 상대적 교합강도와 이개시간의 차이 및 균열치아의 냉검사와 온검사 결과에 따른 군들 간의 최대형광소실도(ΔFmax)와 최대적색형광도(ΔRmax)의 차이를 통계적으로 분석하였다 (α = .05). Spearman correlation analysis를 이용해 최대형광소실도(ΔFmax)와 최대적색형광도(ΔRmax)와 상대적 교합강도 및 이개시간 간의 상관관계를 분석하였다. 결과: 균열치의 상대적 교합강도 및 이개시간은 정상치아에 비하여 통계적으로 유의하게 컸다 (P < .05). 균열치 중 냉검사와 온검사 결과에 따른 각 군들 간의 최대형광소실도(ΔFmax)와 최대적색형광도(ΔRmax)는 통계적으로 유의미한 차이를 보이지 않았다(P > .05). Spearman correlation analysis 결과, 최대형광소실도(ΔFmax)와 최대적색형광도(ΔRmax)와 상대적 교합강도 및 이개시간 간에는 유의미한 상관관계가 없었다 (P > .05). 결론: 본 연구의 결과에 따르면 상대적 교합강도와 이개시간 등의 교합 요소는 치아균열증후군의 발병과 연관이 있었다. Q-ray 검사를 통한 최대형광소실도(ΔFmax)와 최대적색형광도(ΔRmax)의 측정은 치아균열증후군의 진단에는 임상적으로 유용하게 사용될 수 있지만, 임상증상과 정량적인 관계를 입증하지는 못하였다.

유한요소법을 이용한 2급 복합레진 와동의 비교 연구 (A STUDY ON CLASS II COMPOSITE RESIN CAVITY USING FINITE ELEMENT STRESS ANALYSIS)

  • 임영일;여인호;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.428-446
    • /
    • 1997
  • Restorative procedures can lead to weakening tooth due to reduction and alteration of tooth structure. It is essential to prevent fractures to conserve tooth. The resistance to fracture of the restored tooth may be influenced by many factors, among these are the cavity dimension and the physical properties of the restorative material. The placement of direct composite resin restorations has generally been found to have a strengthening effect on the prepared teeth. It is the purpose of this investigation to study the relationship between the cavity isthmus and the fracture resistance of a tooth in composite resin restorations. In this study, MO cavity was prepared on maxillary first premolar. Three dimensional finite element models were made by serial photographic method and isthmus(1/4, 1/3, 1/2 of intercuspal distance) were varied. Two types of model(B and R model) were developed. B model was assumed perfect bonding between the restoration and cavity wall and R model was left unfilled. A load of 500N was applied vertically at the first node from the lingual slope of the buccal cusp tip. This study analysed the displacement, 1 and 2 direction normal stress and strain with FEM software ABAQUS Version 5.2 and hardware IRIS 4D/310 VGX Work-station. The results were as follows : 1. Displacement of buccal cusp in R model occurred and increased as widening of the cavity, and displacement in B model was little and not influenced by cavity width. 2. There was a significant decrease of stress resulting in increase of fracture resistance in B model when compared with R model. 3. With the increase of the isthmus width, B model showed no change in the stress and strain. In R model, the stress and strain increased both in the area of buccal-pulpal line angle and the buccal side of marginal ridge, therefore the possibility of crack increased. 4. The stress and strain were distributed evenly on the tooth in B model, but in R model, were concentrated on the buccal side of the distal marginal ridge and buccal-pulpal line angle, therefore the possibility of fracture increased.

  • PDF

임상가를 위한 특집 3 - 교합력 측정의 방법과 임상적 적용 (The methods for occlusal force measurement and their clinical applicatio)

  • 박지만;허성주;전윤식
    • 대한치과의사협회지
    • /
    • 제50권1호
    • /
    • pp.22-30
    • /
    • 2012
  • The methods for the occlusal force measurement have long been developed. The occlusal analyzing equipment utilizing the pressure-sensitive film (Prescale) is useful for the assessment and comparison among large group of patients. On the other hand, the apparatus which uses the grid-based sensor sheet (T-scan) can be a useful assistant for acquiring the well-balanced occlusion. The device that can process the electrical input from the strain gauge which is attached to the tooth surface can collect the dynamic data of actual masticatory force. This device has been developed for the measurement of actual mastication with the food bolus and it can be a useful method for the comparison before and after the restorative treatment. Occlusal force measurement can be applied for the analysis of therapeutic action, diagnosis of crack- tooth syndrome, temporomandibul ar disease, and idiopathic implant loosening.

Near-infrared Laser Energy Transmission through Teeth with Crack Lines: An In-vitro Study

  • Sapra, Ashita;Darbar, Arun;George, Roy
    • Medical Lasers
    • /
    • 제10권4호
    • /
    • pp.214-219
    • /
    • 2021
  • Background and Objectives To evaluate the difference in near-infrared (810 nm) laser energy transmission through teeth with and without cracks. Materials and Methods Extracted teeth were sectioned and examined visually for the presence of cracks with the aid of photographs and a trans-illuminator. Fourteen sections, each with cracks (Group A) and no cracks (Group B) were identified and placed 15 mm from the tip of a 300 micron fiber, prior to activation with an 810 nm diode laser (0.1W, 50 ms interval,100 ms duration). A power meter positioned behind the tooth recorded the average energy that was transmitted through the samples. Unpaired t-test analysis was used to determine if the tooth sections with cracks allowed higher power passage compared to sound teeth. Results The mean power recording for the cracked teeth (Group A) was significantly greater (p = 0.0005) than that for the non-cracked teeth (Group B). Conclusion Within the limitations of this study, it is evident that significantly higher laser energy passes through teeth with cracks in comparison to teeth without cracks. A recent clinical study has also shown that lasers could be used to assess symptomatic cracked teeth. Hence, further research is required to determine the relative increase in energy required to identify symptomatic cracked teeth.

풍력터빈 기어박스 내의 기어균열에 대한 모델 기반 고장진단 (Model-based Diagnosis for Crack in a Gear of Wind Turbine Gearbox)

  • 임상혁;박성훈;최주호
    • 한국전산구조공학회논문집
    • /
    • 제26권6호
    • /
    • pp.447-454
    • /
    • 2013
  • 모델기반 고장 진단법은 풍력발전기의 상태감지 시스템(Condition monitoring system)에 적용을 목적으로 변동 하중조건하에서 작동하는 기어박스내의 기어의 균열을 진단하기 위해 제시하였다. 두 개의 평기어(Spur gear)로 구성된 간단한 테스트 베드가 위의 접근방법을 검증하기 위해 구축되었고, 기어의 균열은 기어의 뿌리부분에 균열을 인가하여 묘사하였다. 축의 회전속도에 독립적인 타코미터를 기반으로 한 오더분석(Order analysis)을 균열크기 진단에 적용하였고, 테스트 베드의 작동을 시뮬레이션하기 위해 집중변수 모델(Lumped parameter dynamic model)이 사용되었다. 모델에서 균열과 밀접히 관련된 변수는 측정된 신호와 시뮬레이션된 신호 간의 차이를 최소화하는 최적화 기법으로 역추정하였다. 제시한 방법의 유효성을 보이기 위해, 미리 정의된 모델 변수로부터 생성된 시뮬레이션 신호를 테스트-베드로부터 측정된 신호로 가정하고, 제시한 방법을 사용하여 변수를 역추정하였다. 결과는 실제 값과 일치하였고, 이를 통해 알고리즘이 제대로 작동함을 알 수 있었다. 다음 연구에서는 실제 테스트 베드의 실제균열에 적용하고자 한다.

2급 와동의 복합레진 충전에 관한 유한요소법적 응력분석 (FINITE ELEMENT STRESS ANALYSIS OF A CLASS II COMPOSITE RESIN RESTORATION)

  • 송보경;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.627-643
    • /
    • 1995
  • The resistance to fracture of the restored tooth may be influenced by many factors, among these are the cavity dimension and the physical properties of the restorative material. The placement of direct composite resin restorations has generally been found to have a strengthening effect on the prepared teeth. It is the purpose of this investigation to study the relationship between the cavity isthmus and the fracture resistance of a tooth in composite resin restorations. In this study, MO cavity was prepared on the maxillary left first molar and then filled with composite resin. Three dimentional model with 3049 nodes and 2450 8-node blick elements was made by the serial photographic method and isthmus (1/4, 1/3, 1/2 and 2/3 of intercusplal distance between mesiobuccal cusp tip and mesiolingual cusp tip) was varied. Two types of model(B and R model) were developed. B model was assumed perfect bonding between the restoration and cavity wall and R model was left unfilled. A load of 1500N was applied vertically on the node from the lingual slope of the mesiobuccal cusp. The results were as follows : 1. There was a significant decrease of stress resulting in increase of fracture resistance in B model when compared with R model. 2. When it comes to stress distribution, the stress was concentrated in the facio-gingival line angle and the buccal side of the distal margin of the cavity in both Band R model. 3. With the increase of the isthmus width, the stress decreased in the area of the facio-gingival line angle, and increased in the area of facio-gingival line angle as well as the buccal side of the distal margin of the cavity in B model. In R model, the stress increased both in the area of facio-gingival line angle and the buccal side of the distal margin of the cavity, therefore the possibility of crack increased. 4. As the width of cavity increased, in B model, the direction of crack moved from horizontal to vertical on the facio-gingival line angle and the facio-pulpal line angle. In R model, the direction of the crack was horizontal on the facio-gingival line angle and moved from horizontal to the $45^{\circ}$ direction on the facio-pulpal line angle.

  • PDF