• Title/Summary/Keyword: tolerance analysis

Search Result 1,372, Processing Time 0.035 seconds

The Marketing Effect of Loyalty Program on Relational Market Behavior : Focusing in Franchise Membership Fitness Club (로열티 프로그램이 고객 참여와 소비자-브랜드 관계에 기초한 관계형 시장 행동에 미치는 영향 : 프랜차이즈 회원제 휘트니스클럽을 대상으로)

  • Yoon, Kyung-Goo;Shin, Geon-Cheol
    • Journal of Distribution Research
    • /
    • v.17 no.2
    • /
    • pp.1-28
    • /
    • 2012
  • I. Introduction : The purpose of this study is to test empirically hypothetical causality among constructs used in previous studies to build the model of relational market behavior on customers' participation and consumer-brand relationship after introducing theories of relationship marketing, loyalty program, consumer-brand relationship, customers' participation in service marketing as previous studies with regard to relational market behavior, which Bagozzi(1995) and Peterson(1995) commented on constructs and definition suggested by Sheth and Parvatiyar (1995). For this purpose, loyalty program by the service provider, customers' participation and consumer-brand relationship as preceding variables explain relational market behavior defined by Sheth and Parvatiyar(1995). This study proposes that loyalty program as a tool of relationship marketing will be effective in that consumers' participation in marketing relationship results in a narrow range of choice(Sheth and Parvatiyar, 1995) because consumers think that their participation motive result in benefits(Peterson, 1995). Also, it is proposed that the quality of consumer-brand relationship explain the performance of relationship as well as the intermediary effect because the loyalty program could be evaluated based on relationship with customers. We reviewed the variables with regard to performance of relationship based on relation maintain in marketing literature, and then tested our hypotheses related to several performance variables including loyalty and intention of relation maintain based on the previous studies and constructs(Bendapudi and Berry, 1997 ; Bettencourt, 1997 ; Palmatier, Dant, Grewal and Evans, 2006 ; You Jae Yi and Soo Jin Lee, 2006). II. Study Model : Analyses about hypothetical causality were proceeded. The marketing effect of loyalty program on relational market behavior was empirically tested in study regarding a service provider. The research model in according to the path hypotheses (loyalty program ${\rightarrow}$ customers' participation ${\rightarrow}$ consumer-brand relationship ${\rightarrow}$ relational market behavior and loyalty program ${\rightarrow}$ consumer-brand relationship, and loyalty program ${\rightarrow}$ relational market behavior and customers' participation ${\rightarrow}$ consumer-brand relationship, and customers' participation ${\rightarrow}$ relational market behavior) proceeded as an activity for customer relation management was suggested. The main purpose of study is to see if relational market behavior could be brought as a result of developing relationship between consumers and a corporate into being stronger and more valuable when a corporate or a service provider try aggressively to build the relationship with customers (Bettencourt, 1997; Palmatier, Dant, Grewal and Evans, 2006; Sheth and Parvatiyar, 1995). III. Conclusion : The results of research into the membership fitness club, one of service areas with high level of customer participation (Bitner, Faranda, Hubbert and Zeithaml, 1997; Chase, 1978; Kelley, Donnelly, Jr. and Skinner, 1990) are as follows: First, causalities in according to path hypotheses were tested, after the preceding variables affecting relational market behavior and conceptual frame were suggested. In study, all hypotheses were supported as expected. This result confirms the proposition suggested by Sheth and Parvatiyar(1995), who claimed that intention of consumer and corporate to participate in marketing relationship brings high level of marketing productivity. Also, as a corporate or a service provider try aggressively to build relationship with customers, the relationship between consumers and a corporate can be developed into stronger and more valuable one (Bettencourt, 1997; Palmatier, Dant, Grewal and Evans, 2006). This finding supports the logic of relationship marketing. Second, because the question regarding the path hypothesis of consumer-brand relationship ${\rightarrow}$ relational market behavior are still at issue, the further analyses were conducted. In particular, there existed the mediating effects of consumer-brand relationship toward relational market behavior. Also, multiple regressions were conducted to see if which one strongly influences relational market behavior among specific question items with regard to consumer-brand relationship. As a result, the influence between items composing consumer-brand relationship and ones composing relational market behavior was different. Among items composing consumer-brand relationship, intimacy was an influence of sustaining relationship, word of mouth, and recommendation, intimacy and interdependence were influences of loyalty, intimacy and self-connection were influences of tolerance and advice. Notably, commitment among items measuring consumer-brand relationship had the negative influence with relational market behavior. This means that bringing relational market behavior is not consumer-brand relationship without personal commitment, but effort to build customer relationship like intimacy, interdependence, and self-connection. This finding confirms the results of Breivik and Thorbjornsen(2008). They reported that six variables composing the quality of consumer-brand relationship have higher explanation in regression model directly affecting performance of consumer-brand relationship. As a result of empirical analysis, among the constructs with regard to consumer-brand relationship, intimacy(B=0.512), interdependence(B=0.196), and quality of partner(B=0.153) had the effects on relation maintain. On the contrary, self-connection, love and passion, and commitment had little effect and did not show the statistical significance(p<0.05). On the other hand, intimacy(B=0.668) and interdependence(B=0.181) had the high regression estimates on word of mouth and recommendation. Regarding the effect on loyalty, explanation level of the model was high(R2=0.515), intimacy(0.538), interdependence(0.223), and quality of partner(0.177) showed the statistical significance(p<0.05). Furthermore, intimacy(0.441) had the strong effect as well as self-connection(0.201) and interdependence (0.163) had the effect on tolerance and forgive. And these three variables showed effects even on advice and suggestion, intimacy(0.373), self-connection(0.270), interdependence (0.155) respectively. Third, in study with regard to the positive effect(loyalty program ${\rightarrow}$ customers' participation, loyalty program ${\rightarrow}$ consumer-brand relationship, loyalty program ${\rightarrow}$ relational market behavior, customers' participation ${\rightarrow}$ consumer-brand relationship, customers' participation ${\rightarrow}$ relational market behavior, consumer-brand relationship ${\rightarrow}$ relational market behavior), the path hypothesis of customers' participation ${\rightarrow}$ consumer-brand relationship, was supported. The fact that path hypothesis of customers' participation ${\rightarrow}$ consumer-brand relationship was supported confirms assertion by Bitner(1995), Fournier(1994), Sheth and Parvatiyar(1995) about consumer relationship to participate in marketing relationship.

  • PDF

Water Quality and Ecosystem Health Assessments in Urban Stream Ecosystems (도심하천 생태계에서의 수질 및 생태건강성 평가)

  • Kim, Hyun-Mac;Lee, Jae-Hoon;An, Kwang-Guk
    • Korean Journal of Environmental Biology
    • /
    • v.26 no.4
    • /
    • pp.311-322
    • /
    • 2008
  • The objectives of the study were to analyze chemical water quality and physical habitat characteristics in the urban streams (Miho and Gap streams) along with evaluations of fish community structures and ecosystem health, throughout fish composition and guild analyses during 2006$\sim$2007. Concentrations of BOD and COD averaged 3.5 and 5.7 mg L$^{-1}$, in the urban streams, while TN and TP averaged 5.1 mg L$^{-1}$ and 274 ${\mu}g$ L$^{-1}$, indicating an eutrophic state. Especially, organic pollution and eutrophication were most intense in the downstream reach of both streams. Total number of fish was 34 species in the both streams, and the most abundant species was Zacco platypus (32$\sim$42% of the total). In both streams, the relative abundance of sensitive species was low (23%) and tolerant and omnivores were high (45%, 52%), indicating an typical tolerance and trophic guilds of urban streams in Korea. According to multi-metric models of Stream Ecosystem Health Assessments (SEHA), model values were 19 and 24 in Miho Stream and Gap Stream, respectively. Habitat analysis showed that QHEI (Qulatitative Habitat Evaluation Index) values were 123 and 135 in the two streams, respectively. The minimum values in the SEHA and QHEI were observed in the both downstreams, and this was mainly attributed to chemical pollutions, as shown in the water quality parameters. The model values of SEHA were strongly correlated with conductivity (r=-0.530, p=0.016), BOD (r=-0.578, p< 0.01), COD (r=-0.603, p< 0.01), and nutrients (TN, TP: r>0.40, p<0.05). This model applied in this study seems to be a useful tool, which could reflect the chemical water quality in the urban streams. Overall, this study suggests that consistent ecological monitoring is required in the urban streams for the conservations along with ecological restorations in the degradated downstrems.

Comparison and Analysis of Photon Beam Data for Hospitals in Korea and Data for Quality Assurance of Treatment Planning System (국내 의료기관들의 광자 빔 데이터의 비교 분석 및 치료계획 시스템 정도관리자료)

  • Lee, Re-Na;Cho, Byung-Chul;Kang, Sei-Kwon
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.179-186
    • /
    • 2006
  • Purpose: Photon beam data of linear accelerators in Korea are collected, analyzed, and a simple method for checking and verifying the dose calculations in a TPS are suggested. Materials and Methods: Photon beam data such as output calibration condition, output factor, wedge factor, percent depth dose, beam profile, and beam quality were collected from 26 institutions in Korea. In order to verify the accuracy of dose calculation, ten sample planning tests were peformed. These Include square, elongated, and blocked fields, wedge fields, off-axis dose calculation, SSD variation. The planned data were compared to that of manual calculations. Results: The average and standard deviation of photon beam quality for 6, 10, and 15 MV were $0.576{\pm}0.005,\;0.632{\pm}0.004,\;and\;0.647{\pm}0.006$, respectively. The output factors of 6 MV photon beam measured at depth of dose maximum for $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.944{\pm}0.006,\;1.031{\pm}0.006,\;and\;1.055{\pm}0.007$. For 10 MV photon beam, the values were $0.935{\pm}0.006,\;1.031{\pm}0.007,\;1.054{\pm}0.0005$. The collected data were not enough to calculate average, the output factors for 15MV photon beam with field size of $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.941{\pm}0.008,\;1.032{\pm}0.004,\;1.049{\pm}0.014$. There was seven institutions $e{\times}ceeding$ tolerance when monitor unit values calculated from treatment planning system and manually were compared. The measured average MU values for the machines calibrated at SAD setup were 3 MU and 5 MU higher than the machines calibrated at SSD for 6 MV and 10 MV, respectively except the wedge case. When the wedges were inserted, the MU values to deliver 100 cGy to 5 cm depends on manufactures. When the same wedge angle was used, Siemens machine requires more MUs then Varian machine. Conclusion: In this study, photon beam data are collected and analyzed to provide a baseline value for chocking beam data and the accuracy of dose calculation for a treatment planning system.

  • PDF

Biogeochemical Remediation of Cr(VI)-Contaminated Groundwater using MMPH-0 (Enterobacter aerogenes) (MMPH-0 (Enterobacter aerogenes)에 의한 6가 크롬 오염 지하수의 생지화학적 정화)

  • Seo, Hyun-Hee;Rhee, Sung-Keun;Kim, Kang-Joo;Park, Eun-Gyu;Kim, Yeong-Kyoo;Chon, Chul-Min;Moon, Ji-Won;Roh, Yul
    • Economic and Environmental Geology
    • /
    • v.45 no.2
    • /
    • pp.105-119
    • /
    • 2012
  • Indigenous bacteria isolated from contaminated sites play important roles to remediate contaminated groundwater. Chromium has the most stable oxidation states. Cr(VI) is toxic, carcinogenic, and mobile, but Cr(III) is less toxic and immobile. In this study, indigenous microorganism (MMPH-0) was enriched from Cr(VI) contaminated groundwater, and identified by 16S rRNA gene analysis. Using MMPH-0, the effect of stimulating with e-donors (glucose, lactate, acetate, and no e-donor control), respiration conditions, biomass, tolerance, and geochemical changes on Cr(VI) reduction were investigated in batch experiments for 4 weeks. The changes of Cr(VI) concentration and geochemical conditions were monitored using UV-vis-spectrophotometer and Eh-pH meter. And the morphological and chemical characteristics of MMPH-0 and precipitates in the effluents were characterized by TEM-EDS and SEM-EDS analyses. MMPH-0 (Enterobacter aerogenes) was able to tolerate up to 2000 mg/L Cr(VI) and reduce Cr(VI) under aerobic and anaerobic conditions. MMPH-0 performed faster and higher efficiency of Cr(VI) reduction with electron donors (over 70% after 1 week with e-donor, 10-20% after 4 weeks without e-donor). The changes of Eh-pH in effluents showing the tendency from oxidizing to reducing condition and a bit of acidic change in pH due to microbial oxidation of organic matters donating electrons and protons suggested the roles of MMPH-0 on Cr(VI) in the contaminated water catalyzing to transit geochemical stable zone for more stable $Cr(OH)_3$ or Cr(III) precipitates. TEM/SEM-EDS analyses of MMPH-0 and precipitates indicate direct and indirect Cr(VI) reduction: extracellular polymers capturing Cr component outside cells. These results suggested diverse indigenous bacteria and their biogeochemical reactions might enhance more effective and feasible remediation technology of redox sensitive heavy metals in metal-contaminated in groundwater.

Evaluation of the combination of Bone Scan Image and Pelvic X-ray Image (뼈 검사 영상과 골반 X선 영상의 결합 유용성 평가)

  • Lee, Choong Woon;You, Yeon Wook;Kim, Yong Keun;Weon, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.23-27
    • /
    • 2018
  • Purpose The introduction of bone scan has been reported as a useful tool in the diagnosis, treatment, and treatment response of skeletal disease. The purpose of this study is to improve the anatomical information and tolerance of the bone by combining bone scan and pelvic X-ray without additional radiation exposure. Materials and Methods From November 2015 to August 2016, 236 patients(64 men and 172 women, average age $50.96{\pm}15.39years$) take Bone scan and Pelvis AP(Anteroposterior) X-ray scan at the National Cancer Center. The scan equipment was a gamma camera, Symbia Ecam (SIEMENS, Germany), and a digital x-ray, DRS-800 (Listem, Korea). Osirix version 3.8.1 (Osirix, USA) and Stata/SE version 14.0 (StataCorp, USA) were used for image combination and analysis. The patient was intravenously injected with $^{99m}Tc-DPD$ (740 MBq), and the scan was performed 2 to 4 hours later. Gamma camera image acquisition were Matrix size $256{\times}1024$, Zoom 1.00, and scan speed 17 cm/min. The digital X-ray was made with a collimator size of $14^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$, 77 kVp (60 to 97 kVp) and an average of 30 mAs (20 to 48). ASIS and pubic symphysis Select virtual points then Combine three virtual points and pelvic contour lines. The acquired images were evaluated by three radiologists who worked for more than 5 years in the nuclear medicine department. Results Of the total 236 patients, 216 (91.53%) were matched. The median and range (min~max) of the age were 67 (46~81) years old in the unmatched group and 52 (22~87) years old in the matched group, The Wilcoxon rank-sum test was performed to determine whether age was different between the two groups. As a result, the age difference between the two groups was statistically significant at p < 0.0001. Of the 64 men, 60 (93.75%) were match and of the 172 women, 156 (93.75%) were match. There was no statistically significant difference according to gender(p = 0.4542). Of the 54 patients without pelvic lesions, 54 (100.00%) were match, and 162 (89.01%) of 182 patients with pelvic lesions were match. There was a statistically significant difference according to the presence of pelvic lesions. Conclusion There are many variables in the combination of bone scan and pelvic X-ray imaging, and the patient's age and pelvic lesion may have some effect on the image combination. This study is expected to be useful for the diagnosis of pelvic osteosarcoma of children without radiation exposure. It is expected that this combination of images will help to develop the nuclear medicine image.

Quality Assurance of Patients for Intensity Modulated Radiation Therapy (세기조절방사선치료(IMRT) 환자의 QA)

  • Yoon Sang Min;Yi Byong Yong;Choi Eun Kyung;Kim Jong Hoon;Ahn Seung Do;Lee Sang-Wook
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.81-90
    • /
    • 2002
  • Purpose : To establish and verify the proper and the practical IMRT (Intensity--modulated radiation therapy) patient QA (Quality Assurance). Materials and Methods : An IMRT QA which consists of 3 steps and 16 items were designed and examined the validity of the program by applying to 9 patients, 12 IMRT cases of various sites. The three step OA program consists of RTP related QA, treatment information flow QA, and a treatment delivery QA procedure. The evaluation of organ constraints, the validity of the point dose, and the dose distribution are major issues in the RTP related QA procedure. The leaf sequence file generation, the evaluation of the MLC control file, the comparison of the dry run film, and the IMRT field simulate image were included in the treatment information flow procedure QA. The patient setup QA, the verification of the IMRT treatment fields to the patients, and the examination of the data in the Record & Verify system make up the treatment delivery QA procedure. Results : The point dose measurement results of 10 cases showed good agreement with the RTP calculation within $3\%$. One case showed more than a $3\%$ difference and the other case showed more than $5\%$, which was out side the tolerance level. We could not find any differences of more than 2 mm between the RTP leaf sequence and the dry run film. Film dosimetry and the dose distribution from the phantom plan showed the same tendency, but quantitative analysis was not possible because of the film dosimetry nature. No error had been found from the MLC control file and one mis-registration case was found before treatment. Conclusion : This study shows the usefulness and the necessity of the IMRT patient QA program. The whole procedure of this program should be peformed, especially by institutions that have just started to accumulate experience. But, the program is too complex and time consuming. Therefore, we propose practical and essential QA items for institutions in which the IMRT is performed as a routine procedure.

Lung Preservation Study for Above 20 Hours of LPDG Solution in Canine Lung Allotransplactation (폐이식 실험견에서 LPDG용액을 이용한 20시간 이상 폐보존효과 관찰)

  • Park, Chang-Gwon;Gwon, Geon-Yeong;Yu, Yeong-Seon
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.949-960
    • /
    • 1997
  • Background. Limited ischemic tolerance of the lung has remained one of the factors that limits the expansion of pulmonary transplantation as a treatment for end-stage pulmonary disease. Numerous studies on safe long term preservation for lung transplantation has been performed for the purpose of developing ideal preservation solution with extracellular type or intracellular type solutions. In this. study, we examined the efficacy of L DG solution in lung preservation longer than 20 hours by comparison with modified Euro-Collins solution. Iwethods. Thirty-(our adult mongrel dogs were divided into two groups. Donor lungs were flushed with LPDG solution(n=9) or modified Euro-Collins(MEC) solution(n=8) and stored for 24 hours at 1$0^{\circ}C$. All donor lungs were perfused through the pulmonary arteries with solutions containing prostaglandin El and verapamil. Left canine lung allotransplantations wereperformed. Assessment(hemodynamic indices and arterial blood gas analysis) of left implanted lung was made by occluding the right pulmonary artery for ten minutes using pulmonary artery Cuff. Assessment was repeated at the interval of 30 minutes, one hour, and two hours later after reperfusion and then chest X-ray, computed tomogram and lung perfusion scan were obtained. In survival dogs follow-up studies were done with assessment with chest X-ray, computed tomogram of the chest and lung perfusion scan on 7th day postoperatively. After preservation above 20 hours, pathological examinations for ultrastructural findings on right lung were performed in each group. Results. With respect to arterial oxygen tension, LPDG group was superior to MEC but there was no statistical significance for 2 hours after reperfusion. Mean pulmonary artery pressure was less increased(p < 0.05) and cardiac output higher(p <0.05) than MEC group until 2 hours after reperfusion. After 2 hours of reperfusion, both groups showed transplanted lung function deteriorated gradually. Perfusion scan of the transplanted lung in LPDG group showed better perfusion rate in immediate post-reperfusion, 3 days and 7 days later respectively but there was no statistical significance and corelation with PaO2 and computed tomoRravhic views. In scanning electron microscopy of pulmonary artery after preservation, LPDG group relatively shows less irregular protrusion of the inner surface of endothelial cell of poulmonary artery than MEC group. Conclusions, e concluded that LPDG solution can offer safe lung preservation above 20 hours with adequate immunosuppressive therapy and prevention of the infection.

  • PDF

Mitigation Effects of Foliar-Applied Hydrogen Peroxide on Drought Stress in Sorghum bicolor (과산화수소 엽면 처리에 의한 수수에서 한발 스트레스 완화 효과)

  • Shim, Doo-Do;Lee, Seung-Ha;Chung, Jong-Il;Kim, Min Chul;Chung, Jung-Sung;Lee, Yeong-Hun;Jeon, Seung-Ho;Song, Gi-Eun;Shim, Sang-In
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.65 no.2
    • /
    • pp.113-123
    • /
    • 2020
  • Global climatic change and increasing climatic instability threaten crop productivity. Due to climatic change, drought stress is occurring more frequently in crop fields. In this study, we investigated the effect of treatment with hydrogen peroxide (H2O2) before leaf development on the growth and yield of sorghum for minimizing the damage of crops to drought. To assess the effect of H2O2 on the growth of sorghum plant, 10 mM H2O2 was used to treat sorghum leaves at the 3-leaf stage during growth in field conditions. Plant height, stem diameter, leaf length, and leaf width were increased by 7.6%, 9.6%, 8.3% and 11.5%, respectively. SPAD value, chlorophyll fluorescence (Fv/Fm), photosynthetic rate, stomatal conductance, and transpiration rate were increased by 3.0%, 4.9%, 26.0%, 23.4% and 12.7%, respectively. The amount of H2O2 in the leaf tissue of sorghum plant treated with 10 mM H2O2 was 0.7% of the applied amount after 1 hour. The level increased to approximately 1.0% after 6 hours. The highest antioxidant activity measured by the Oxygen Radical Absorbance Capacity assay was 847.3 µmol·g-1 at 6 hour after treatment. However, in the well-watered condition, the concentration of H2O2 in the plant treated by the foliar application of H2O2 was 227.8 µmol·g-1 higher than that of the untreated control. H2O2 treatment improved all the yield components and yield-related factors. Panicle length, plant dry weight, panicle weight, seed weight per plant, seed weight per unit area, and thousand seed weight were increased by 8.8%, 18.0%, 24.4%, 24.7%, 29.9% and 7.1%, respectively. Proteomic analysis showed that H2O2 treatment in sorghum increased the tolerance to drought stress and maintained growth and yield by ameliorating oxidative stress.

A Study on the Necessary Number of Bolus Treatments in Radiotherapy after Modified Radical Mastectomy (변형 근치적 유방절제술 후 방사선치료에서 볼루스 적용횟수에 대한 고찰)

  • Hong, Chae-Seon;Kim, Jong-Sik;Kim, Young-Kon;Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.113-117
    • /
    • 2006
  • Purpose: Post-mastectomy radiotherapy (PMR) is known to decrease loco-regional recurrence. Adequate skin and dermal dose are achieved by adding bolus. The more difficult clinical issue is determining the necessary number of bolus treatment, given the limits of normal skin tolerance. The aim of this study is to evaluate the necessary number of bolus treatment after PMR in patients with breast cancer. Materials and Methods: Four female breast cancer patients were included in the study. The median age was 53 years(range, $38{\sim}74$), tumor were left sided in 2 patients and right sided in 2patients. All patients were treated with postoperative radiotherapy after MRM. Radiotherapy was delivered to the chest wall (C.W) and supraclavicular lymph nodes (SCL) using 4 MV X-ray. The total dose was 50 Gy, in 2 Gy fractions (with 5 times a week). CT was peformed for treatment planning, treatment planning was peformed using $ADAC-Pinnacles^3$ (Phillips, USA) for all patients without and with bolus. Bolus treatment plans were generated using image tool (0.5 cm of thickness and 6 cm of width). Dose distribution was analyzed and the increased skin dose rate in the build-up region was computed and the skin dose using TLD-100 chips (Harshaw, USA) was measured. Results: No significant difference was found in dose distribution without and with bolus; C.W coverage was $95{\sim}100%$ of the prescribed dose in both. But, there was remarkable difference in the skin dose to the scar. The skin dose to the scar without and with bolus were $100{\sim}105%\;and\;50{\sim}75%$. The increased skin dose rates in the build-up region for Pt. 1, Pt. 2. Pt. 3 and Pt. 4 were 23.3%, 35.6%, 34.9%, and 41.7%. The results of measured skin dose using TLD-100 chips in the cases without and with bolus were 209.3 cGy and 161.1 cGy, 200 cGy and 150.2 cGy, 211.4 cGy and 160.5 cGy, 198.6 cGy and 155.5 cGy for Pt. 1, Pt. 2, Pt. 3, and Pt. 4. Conclusion: It was concludes through this analysis that the adequate number of bolus treatments is 50-60% of the treatment program. Further, clinical trial is needed to evaluate the benefit and toxicity associated with the use of bolus in PMR.

  • PDF

Development of a Method to Measure the Radiation Isocenter Size of Linear Accelerators and Quantitative Analysis of the Radiation Isocenter Size for Clinac 21EX Linear Accelerator (선형가속기 방사선 중심점의 크기 측정 방법 개발과 Clinac 21EX 선형가속기의 방사선 중심점 크기 분석)

  • Jeon, Ho-Sang;Nam, Ji-Ho;Park, Dahl;Kim, Yong-Ho;Kim, Won-Taek;Kim, Dong-Won;Ki, Yong-Kan;Kim, Dong-Hyun
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.131-139
    • /
    • 2011
  • A method to get a size of the radiation isocenter of linear accelerators using star-shot images was presented and a computer program was developed to automate the method. Accuracy of the method was verified. The developed program was used to measure sizes of the radiation isocenters for a Clinac 21EX (Varian, USA) using data of quality assurance (QA) performed from June 2008 to December 2010. To calculated the size of radiation isocenter, positions of two points on each central ray of the star-shot image were found and the equation of the central ray was determined using the positions of two points. Using the equations of central rays the radius of the minimum circle intersecting all the central rays, which is one half of the size of radiation isocenter, was calculated. The program measured x-intercepts and y-intercepts of the central rays within errors of 0.084 mm and sizes of radiation isocenters within 0.053 mm. All the errors were less than the spatial resolution of star-shot images 0.085 mm. The radiation isocenter sizes of Clinac 21EX were $0.33{\pm}0.27mm$, $0.71{\pm}0.36mm$, $0.50{\pm}0.16mm$ for collimator, gantry and couch respectively. During the measurement period all the measured sizes were less than 2.0 mm and within tolerance. The developed program could calculate the size of radiation isocenters and it would be helpful to routine QA.