A Study on the Necessary Number of Bolus Treatments in Radiotherapy after Modified Radical Mastectomy

변형 근치적 유방절제술 후 방사선치료에서 볼루스 적용횟수에 대한 고찰

  • Hong, Chae-Seon (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Kim, Jong-Sik (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Kim, Young-Kon (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Park, Young-Hwan (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine)
  • 홍채선 (성균관대학교 의과대학 삼성서울병원 방사선종양학과) ;
  • 김종식 (성균관대학교 의과대학 삼성서울병원 방사선종양학과) ;
  • 김영곤 (성균관대학교 의과대학 삼성서울병원 방사선종양학과) ;
  • 박영환 (성균관대학교 의과대학 삼성서울병원 방사선종양학과)
  • Published : 2006.09.30

Abstract

Purpose: Post-mastectomy radiotherapy (PMR) is known to decrease loco-regional recurrence. Adequate skin and dermal dose are achieved by adding bolus. The more difficult clinical issue is determining the necessary number of bolus treatment, given the limits of normal skin tolerance. The aim of this study is to evaluate the necessary number of bolus treatment after PMR in patients with breast cancer. Materials and Methods: Four female breast cancer patients were included in the study. The median age was 53 years(range, $38{\sim}74$), tumor were left sided in 2 patients and right sided in 2patients. All patients were treated with postoperative radiotherapy after MRM. Radiotherapy was delivered to the chest wall (C.W) and supraclavicular lymph nodes (SCL) using 4 MV X-ray. The total dose was 50 Gy, in 2 Gy fractions (with 5 times a week). CT was peformed for treatment planning, treatment planning was peformed using $ADAC-Pinnacles^3$ (Phillips, USA) for all patients without and with bolus. Bolus treatment plans were generated using image tool (0.5 cm of thickness and 6 cm of width). Dose distribution was analyzed and the increased skin dose rate in the build-up region was computed and the skin dose using TLD-100 chips (Harshaw, USA) was measured. Results: No significant difference was found in dose distribution without and with bolus; C.W coverage was $95{\sim}100%$ of the prescribed dose in both. But, there was remarkable difference in the skin dose to the scar. The skin dose to the scar without and with bolus were $100{\sim}105%\;and\;50{\sim}75%$. The increased skin dose rates in the build-up region for Pt. 1, Pt. 2. Pt. 3 and Pt. 4 were 23.3%, 35.6%, 34.9%, and 41.7%. The results of measured skin dose using TLD-100 chips in the cases without and with bolus were 209.3 cGy and 161.1 cGy, 200 cGy and 150.2 cGy, 211.4 cGy and 160.5 cGy, 198.6 cGy and 155.5 cGy for Pt. 1, Pt. 2, Pt. 3, and Pt. 4. Conclusion: It was concludes through this analysis that the adequate number of bolus treatments is 50-60% of the treatment program. Further, clinical trial is needed to evaluate the benefit and toxicity associated with the use of bolus in PMR.

목 적: 유방암으로 진단 받고 변형 근치적 유방절제술(Modified Radical Mastectomy)후 흉벽에 방사선치료를 시행 받고 있는 환자를 대상으로 볼루스(Bolus) 적용에 따른 흉벽(흉터, 수술봉합부위)의 피부선량 변화를 분석 하여 적절한 볼루스 적용횟수를 얻고자 한다. 대상 및 방법: 유방암으로 진단받고 변형 근치적 유방절제술 후 방사선치료를 받고 있는 4명의 여성 환자(우측 2명 좌측 2명)를 대상으로 하였다. 흉벽 방사선조사는 4 MV광자선으로 매일 2 Gy씩 주 5회, 접선조사로 치료하였고, 총 조사선량은 50 Gy였는데 동측 내유방림프절은 포함하지 않았다. 치료 계획을 위한 전산화단층촬영에서 흉터 부위의 위치 확인을 위해 방사선비투과성물질인 Angio-catheter를 흉터 위에 위치시켰다. 획득한 영상을 이용하여 치료계획을 세웠고, 전산화치료계획장치에서 흉터부위 좌우 2 cm 영역을 포함하는 두께 0.5 cm, 넓이 6 cm의 볼루스를 적용시켰다. 계획한 내용을 바탕으로 볼루스를 적용하지 않은 경우와 볼루스를 적용한 경우에 대하여 선량분포 변화와 피부선량을 비교 분석하였고 열형광선량계 (Thermoluminescent dosimetry: TLD, Harshaw, USA)를 이용하여 관심 부위(흉터 부위 3 지점, 흉터 좌측 1 cm 3지점, 흉터 우측 1 cm 3지점) 9개 지점의 선량을 실측하였다. 결 과: 전산화치료계획장치에서 얻어진 선량분포를 통해 분석한 결과, 볼루스를 적용하지 않은 경우와 볼루스를 적용한 경우 모두에서 흉벽 부위에 $95{\sim}100%$ 선량이 감싸고 있었으나, 흉터 주위 피부선량에 있어서는 볼루스를 적용하지 않은 경우($50{\sim}75%$)와 볼루스를 적용한 경우($100{\sim}105%$)가 큰 차이를 보였다. 선량분포를 통한 관심지점의 피부선량은 볼루스를 적용하지 않은 경우에 비해 볼루스를 적용한 경우에서 환자 1번 23.3%, 환자 2번 35.6%, 환자 3번 34.9%, 환자 4번 41.7%의 선량 증가를 보였다. 볼루스를 적용하지 않은 경우와 볼루스를 적용한 경우의 TLD 평균 측정치는 환자 1번 161.1 cGy 209.3 cGy 환자 2번 150.2 cGy, 200 cGy, 환자 3번 150.5 cGy, 211.4 cGy, 환자 4번 155.5 cGy 198.6 cGy의 결과를 얻었다. 결 론: 본 원에서 변형 근치적 유방절제술 후 흉벽 방사선치료의 가장 적절한 볼루스 적용 횟수는 전 치료횟수의 $50{\sim}60%$ 적용이다.

Keywords