Evaluation of the combination of Bone Scan Image and Pelvic X-ray Image

뼈 검사 영상과 골반 X선 영상의 결합 유용성 평가

  • Lee, Choong Woon (Department of Nuclear Medicine and Research Institute, National Cancer Center) ;
  • You, Yeon Wook (Department of Nuclear Medicine and Research Institute, National Cancer Center) ;
  • Kim, Yong Keun (Department of Nuclear Medicine and Research Institute, National Cancer Center) ;
  • Weon, Woo Jae (Department of Nuclear Medicine and Research Institute, National Cancer Center)
  • Received : 2018.04.14
  • Accepted : 2018.04.30
  • Published : 2018.05.19

Abstract

Purpose The introduction of bone scan has been reported as a useful tool in the diagnosis, treatment, and treatment response of skeletal disease. The purpose of this study is to improve the anatomical information and tolerance of the bone by combining bone scan and pelvic X-ray without additional radiation exposure. Materials and Methods From November 2015 to August 2016, 236 patients(64 men and 172 women, average age $50.96{\pm}15.39years$) take Bone scan and Pelvis AP(Anteroposterior) X-ray scan at the National Cancer Center. The scan equipment was a gamma camera, Symbia Ecam (SIEMENS, Germany), and a digital x-ray, DRS-800 (Listem, Korea). Osirix version 3.8.1 (Osirix, USA) and Stata/SE version 14.0 (StataCorp, USA) were used for image combination and analysis. The patient was intravenously injected with $^{99m}Tc-DPD$ (740 MBq), and the scan was performed 2 to 4 hours later. Gamma camera image acquisition were Matrix size $256{\times}1024$, Zoom 1.00, and scan speed 17 cm/min. The digital X-ray was made with a collimator size of $14^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$, 77 kVp (60 to 97 kVp) and an average of 30 mAs (20 to 48). ASIS and pubic symphysis Select virtual points then Combine three virtual points and pelvic contour lines. The acquired images were evaluated by three radiologists who worked for more than 5 years in the nuclear medicine department. Results Of the total 236 patients, 216 (91.53%) were matched. The median and range (min~max) of the age were 67 (46~81) years old in the unmatched group and 52 (22~87) years old in the matched group, The Wilcoxon rank-sum test was performed to determine whether age was different between the two groups. As a result, the age difference between the two groups was statistically significant at p < 0.0001. Of the 64 men, 60 (93.75%) were match and of the 172 women, 156 (93.75%) were match. There was no statistically significant difference according to gender(p = 0.4542). Of the 54 patients without pelvic lesions, 54 (100.00%) were match, and 162 (89.01%) of 182 patients with pelvic lesions were match. There was a statistically significant difference according to the presence of pelvic lesions. Conclusion There are many variables in the combination of bone scan and pelvic X-ray imaging, and the patient's age and pelvic lesion may have some effect on the image combination. This study is expected to be useful for the diagnosis of pelvic osteosarcoma of children without radiation exposure. It is expected that this combination of images will help to develop the nuclear medicine image.

[목적] 뼈 검사는 골격계 질환에 대한 예민도와 높은 해상력의 핵의학 영상 검사이다. 본 연구는 추가적인 방사선피폭없이 뼈 검사 영상과 골반 X선 영상의 결합을 시행하고 영상의 해부학적 정보와 관용도를 증가시켜 환자 병변 진단에 도움이 되고자 한다. 2015년 11월에서 2016년 8월까지 본원에서 뼈 검사를 실시한 환자 중 골반 X선 촬영을 시행한 236명을 대상으로 진행하였다.(남자 64명, 여자 172명, 평균연령 $50.96{\pm}15.39$세) 검사장비는 감마카메라 Symbia Ecam(SIEMENS, Germany)을 사용하였고 디지털 엑스레이는 DRS-800(Listem, Korea)을 사용하였다. 영상의 결합 및 분석프로그램은 Osirix version 3.8.1(Osirix, USA), 통계프로그램은 Stata/SE 버전 14.0(StataCorp, USA)를 사용하였다. 환자에게 $^{99m}Tc-DPD$ 740 MBq을 정맥주사한 후 2~4시간이 지난 뒤에 검사를 진행하였다. 감마카메라 영상 획득 조건은 Matrix size $256{\times}1024$, Zoom 1.00, 검사 속도 17 cm/min로 하였다. 디지털 엑스레이는 Collimator size $14^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$, 77 kVp(60~97kVp), 평균 30 mAs(20~48)로 전상장골극과 치골결합 사이 수직입사를 하였다. Osirix 상에서 골반 뼈의 윤곽 및 가상의점을 선택하여 결합하고 획득한 영상을 핵의학과 5년 이상 근무한 방사선사 3명에 의해 평가 되었으며, 모두 동일할 경우 일치, 하나라도 동일하지 않을 경우 불일치로 평가하였다. 전체 236명 중 일치하는 대상은 216명 (91.53%) 이다. 연령의 중위수 및 범위(최소값~최대값)는 일치하지 않는 그룹에서 67(46~81)세, 일치하는 그룹에서 52(22~87)세로, 일치하지 않는 그룹의 연령이 더 높은 것을 확인하였고, 두 군 간에 연령이 다른지 Wilcoxon rank-sum test를 수행해 본 결과, 통계적으로 유의하게 두 군 간에 나이가 차이나는 것을 확인할 수 있었다(p < 0.0001). 남자는 64명 중 60명(93.75%), 여자는 172명 중 156명(90.70%)가 일치하였고, 골반 병변이 없던 환자는 54명 중 54명(100.00%), 골반 병변이 있던 환자는 182명 중 162명(89.01%) 일치하였고, 골반 병변 여부에 따른 일치율은 통계적으로 유의한 차이를 보였다(p = 0.0094). 뼈 검사와 골반 X선 영상을 결합하는데 있어서 여러 가지 변수가 있을 수 있었고 환자의 연령과 골반병변이 영상의 결합에 일부 영향을 줄 수 있을 것으로 생각된다. 본 연구를 통하여 방사선 피폭 없이 소아의 골반 골육종 진단에 도움이 되리라 사료되고 이와 같은 영상의 결합 연구를 통해서 핵의학 영상발전에 도움이 될 것으로 기대된다.

Keywords

References

  1. 고창순 외. 제3판 고창순 핵의학. 고려의학. 2008. p.509-513.
  2. 영상의학 검사(일반촬영)에서의 표준 촬영기법(식품의약품안전처).
  3. Zaidi H, Montandon ML, Alavi A. The Clinical Role of Fusion Imaging Using PET, CT, and MR Imaging, PET Clin, 2008 Jul; 3(3):275-91. Epub 2009 Jun 21.
  4. Richard L. Wahl, MD, Why Nearly All PET of Abdominal and Pelvic Cancers Will Be Performed as PET/CT, J Nucl Med January 1, 2004 vol. 45 no. 1 suppl 82S-95S.